Carrier Furnace User Manual

Owner’s Manual

NOTE TO INSTALLER:
THIS MANUAL MUST BE LELT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS LOR EUTURE REEERENCE.

A. WARNING

Failure to follow warnings could result in personal injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance,

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance,
-Do not touch any electrical switch; do not use any phone in your building,
-Leave the building immediately,
-Immediately call your gas supplier from a nearby
phone. Follow the gas supplier’s instructions,
-If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.

A WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Install a carbon monoxide alarm in your home, even if you do not own a gas appliance. Locate the carbon monoxide alarm in the living area of your home and away from gas appliances and doorways to attached garages. Follow the alarm manufacturer’s instruction included with the alarm.

A WARNING

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury, death, or property damage.
Do not use this furnace if any part has been under water, A flood-damaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion, A qualified service agency should be contacted to inspect the furnace and to replace all gas controls, control system parts, and electrical parts that have been wet, or the entire furnace if deemed necessary.

TABLE OF CONTENTS

WELCOME TO A NEW GENERATION OF COMFORT
_______
FURNACE COMPONENTS..............................................................3
SAFETY CONSIDERATIONS .........................................................4
BEFORE STARTING YOUR FURNACE
........................................
STARTING YOUR FURNACE
SHUTTING DOWN YOUR FURNACE
PERFORMING ROUTINE MAINTENANCE
..........................................
................................
FILTERING OUT TROUBLE...........................................................9
COMBUSTION AREA AND VENT SYSTEM
WINTERIZATION
A CHECK-UP CHECKLIST
..........................................................................
...........................................................
............................
11
13
13
BEFORE YOU REOUEST A SERVICE CALL............................. 13
INSTALLATION DATA................................................................. 14
2
3
7
8
Always Ask For
WELCOME TO TODAY’S GENERATION
OF COMFORT
Congratulations! In light of rising energy costs, a 90+% AFUE Condensing Gas Furnace from Carrier Corporation is among the soundest investments today’s homeowner can make.
Your new furnace is truly a triumph of technology in home
heating. A revolutionary design employs two heat exchangers to “squeeze” out the maximum amount of heat from the fuel consumed. In fact, your new furnace is so efficient, over 90%* of the heat generated during combustion is captured and delivered inside your home.
This furnace is among the safest, most dependable, energy-efficient furnaces you can buy today. We are proud of the technological advances incorporated into the design of this furnace. With only minimal care, your new furnace will deliver many years of money-saving home comfort and enjoyment. Spend just a few minutes with this manual to learn the operation of your new furnace and the small amount of maintenance it takes to help keep it operating at peak efficiency year after year.
* The output capacity and any representations of efficiency for this furnace are based on standard U.S. Department of Energy test procedures.
A1‘ |>\iïïS
Use of the AHRI Certified TM Mark indicates a manufacturer's participation in the program For verification of certification for individual products, go to www.ahridirectory.org.

A. WARNING

ELECTRICAL SHOCK, EIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death, or property damage.
Improper servicing could result in dangerous operation, serious injury, death or property damage.
Before servicing, disconnect all electrical power to furnace.
When servicing controls, label all wires prior to discon necting. Reconnect wires correctly.
Verify proper operation after servicing.
(Furnace shown in iipflow position; may be used in downflow or horizontal orientation or applications.
MANUAL RESET ROLLOUT SWITCH
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS
INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)

FURNACE COMPONENTS

HOT SURFACE
GAS BURNER
IGNITER
MANUAL RESET ROLLOUT SWITCH
MAIN LIMIT SWITCH
- (BEHIND GAS VALVE)
INDUCER MOTOR
ASSEMBLY
BLOWER DOOR SAFETY SWITCH
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
MEDIA CABINET
BLOWERAND
‘MOTOR
CAPACITOR/ POWER CHOKE
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
Fig. 1 - Furnace Components

SAFETY CONSIDERATIONS

Installing and servicing of heating equipment can be hazardous due to gas and electrical components. Only trained and qualified personnel should install, repair, or service heating equipment.
Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters. All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace and other safety precautions that may apply.
Recognize safety information. This is the safety-alert symbol ^ , When you see this symbol on the furnace and in instructions or manuals, be alert to the potential for personal injury.
Understand the signal words DANGER, WARNING, CAUTION, and NOTE, DANGER, WARNING, and CAUTION are used with the safety-alert symbol, DANGER identifies the most serious hazards which will result in severe personal injury or death, WARNING signifies hazards which could result in personal injury or death, CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage, NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation.
To minimize the possibility of serious personal injury, fire, damage to your furnace, or improper operation, carefully follow these safety rules which apply to both direct-vent and non-direct vent applications:
• Your new gas furnace may have been installed in one of two ways, as a direct-vent (2-pipe-Fig, 2) application or as a non-direct vent (f-pipe-Fig, 3) application,
• In a direct-vent (2-pipe) application, your furnace uses air from outside the home for combustion and vents flue gas to the outdoors. This type of application will have two pipes running from the furnace to the outdoors. In some cases, the inlet air pipe may be located in an area that has access to outdoor air, such as
an attic. In all cases, the outlet vent pipe must be routed to the
outdoors, (See Fig, 2,) In this application, the vent and
air-intake pipes must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings on furnace or spaces around furnace,
• In a non-direct vent (1-pipe) application, your furnace uses
air from adjacent to the furnace for combustion and vents flue gas to the outdoors. This type of application will have only one pipe running from the furnace to the outdoors, (See Fig, 3,) The other pipe will terminate in the same space as the furnace and is the source of combustion air for your furnace. Therefore, the furnace must not be enclosed in an airtight room or be sealed behind solid doors. It must have adequate airflow for efficient combustion and safe ventilation. Do not obstruct the combustion-air pipe in any way. The vent pipe must terminate outside the structure and must not be obstructed in any way. Do not block or obstruct air openings or space around furnace.

A WARNING

Failure to follow warnings could result in personal injury, death, or property damage.
Keep insulation clear of furnace and maintain clearances shown on unit clearance label.
Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace.

A WARNING

Failure to follow this warning could result in personal injury, death, or property damage.
Do not keep combustible materials, gasoline, and other flammable liquids or vapors around your furnace.
Keep the area around your furnace clear and free of combustible materials, gasoline, and other flammable liquids and vapors.
Fig. 4 - NO combustible materials near furnace
extended period of time, have it checked periodically for proper operation. This precaution will prevent problems associated with no heat, such as frozen water pipes, etc. See “Before You Request a Service Call” section in this manual.

BEFORE STARTING YOUR FURNACE

Examine the furnace installation to determine that:
1, All flue gas carrying areas external to the furnace (i.e, chim
ney, vent connector) are clear and free of obstructions,
2, The vent connector is in place, slopes upward and is physic
ally sound without holes or gaps,
3, The return-air duct connection(s) is physically sound, is
sealed to the furnace casing, and terminates outside the space containing the furnace.
4, The physical support of the furnace is sound without sag
ging cracks, gaps, etc. around the base,
3. There are no obvious signs of deterioration of the furnace, 6, The burner flames are in good adjustment. See Fig. 3 (by
comparison with pictorial sketches or drawings of the main burner flame.)
Burner Flame
Burner
Do not cover the furnace, store trash or debris near it, or in any way block the flow of fresh air to the unit.
A CAUTION
UNIT OPERATION HAZARD
Failure to follow this caution may result in intermittent unit
operation.
For proper and safe operation the furnace needs air for
combustion and ventilation. Do not block or obstruct air
openings on the furnace, air opening to the area in which the
furnace is installed, and the space around the furnace.
• In addition to the safety rules above, make sure that the
following combustion-air requirements are met for non-direct
vent applications:
• Combustion air must be clean and uncontaminated with chlorine or fluorine. These compounds are present in many products
around the home, such as: water softener salts, laundry bleaches,
detergents, adhesives, paints, varnishes, paint strippers, waxes,
and plastics,
• Make sure the combustion air for your furnace does not contain
any of these compounds. During remodeling be sure the
combustion air is fresh and uncontaminated. If these compounds
are burned in your furnace, the heat exchangers may deteriorate,
• A furnace installed in an attic or other insulated space must be kept free and clear of insulating material. Examine the furnace
area when the furnace is installed or when insulation is added. Some insulation materials may be combustible,
• Should the gas supply fail to shut off or if overheating occurs, shut off the gas valve to the furnace before shutting off electrical supply.
This furnace contains SAFETY DEVICES which must be MANUALLY RESET, If the furnace is left unattended for an
* •
Manifold
Fig. 5 - Burner Flame Adjustment
^ WARNING
FIRE AND EXPLOSION HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Should the gas supply fail to shut off or if overheating occurs, turn off the manual gas valve to the furnace BEFORE turning off the electrical supply and install lockout tag.

STARTING YOUR FURNACE

Instead of a continuously burning pilot flame which wastes valuable energy, your furnace uses an automatic, hot surface ignition system to light the burners each time the thermostat signals the furnace to start.
Follow these important safeguards:
• Never attempt to manually light the burners with a match or other source of flame.
Fig. 6 - Do Not Light Burner with Match
Read and follow the operating instructions on inside of main furnace door, especially the item that reads as fol lows: (See Fig. 3f,) “Wait 5 minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Fol low “B” in the safety information on furnace label. If you don’t smell gas, go to the next step.”
If a suspected malfunction occurs with your gas control system, such as the burners do not light when they should, refer to the shutdown procedures on inside of main furnace door, or in the “Shutting Down Your Fur nace” section and call your dealer as soon as possible.
CHECK AIR FILTER: Before attempting to start your furnace, be sure the furnace filter is clean and in place. See “Performing Routine Maintenance” section in this manual. Do not run the furnace without a filter in place. Then proceed as follows:

STEPS FOR STARTING YOUR FURNACE

f. Set your room thermostat to the lowest temperature setting
and set the “MODE” to “OFF”. See Fig. 7.
Fig. 9 - Turn Off Electrical Supply
4. Remove the main furnace door. See Fig. fO.
2. Close the external manual gas valve. See Fig. 8.
3. Turn OFF electrical supply to the furnace. See Fig. 9.
A112S6
Fig. 10 - Remove Main Furnace Door (Upflow Configuration)
3. Turn the control switch on the gas control to the OFF position and waits minutes. See Fig. ff. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” on furnace label. If you don’t smell gas, go to next step.
SINGLE-STAGE GAS CONTROL
TWO STAGE GAS CONTROL
Fig. 11 - Control Switch to OFF
6, After waiting five minutes, turn control switch on the gas con
trol to the ON position. Turn the control switch to ON, See Fig. 12,
Fig. 14 - Turn on Electrical Supply
9, Open the external manual gas valve. See Fig. 13,
Fig. 12 - Control Switch to ON
7, Replace main furnace door. See Fig. 13,
Fig. 13 - Furnace Door Replaced (Upflow Configuration)
8, Turn ON the electrical supply to the furnace and wait one
minute. See Fig. 14,
A112S7
Fig. 15 - Open Valve
10, Set the room thermostat “MODE” to “HEAT” and adjust the
set point to a temperature slightly above the room temperat ure, This will automatically signal the furnace to start.
11, When the furnace receives the start signal, the combustion air
draft inducer is started. When the pressure switch senses that there is sufficient combustion air, the hot surface igniter is en ergized. After the hot surface igniter is heated for about 20 seconds, the gas valve permits gas to flow to the main burners. After igni tion and a time delay of up to 60 sec, the furnace blower will start. Variable-capacity furnaces start at low speed until the control makes the necessary adjustments to operate the blower at either the low- or high-heat speed.
NOTE: If the main burners fail to ignite after four attempts, the furnace control system will lock out. If lockout occurs, main burners fail to light, or blower does not come on, shut down the furnace and call your dealer for service.
12, Set your thermostat to the temperature that satisfies your
comfort requirements, SUGGESTION: Setting the thermo stat back a few degrees—and compensating for the differ ence with warmer clothing—can make a big difference in your fuel consumption on extremely cold days. The few de grees at the top of your thermostat “comfort level” are the most costly degrees to obtain.
When the room temperature drops below the temperature selected on the thermostat, the furnace will switch on automatically. When the room temperature reaches the setting selected on the thermostat, the furnace will be automatically switched off.
Continuous Fan Operation -Some thermostats have a “FAN” switch with two selections: AUTO and ON, When the thermostat is set on AUTO, the furnace blower cycles on and off, controlled by the thermostat. In ON position, the furnace blower runs continuously. Continuous fan keeps the temperature level in your home more evenly balanced. It also continuously filters the indoor air.
Comfort Fan™ - On all but the base series furnace, the blower speed can be increased or decreased if desired due to change of seasons, large gatherings in your home, etc. Simply change your FAN from ON to OFF for f to 3 seconds (or AUTO depending on your thermostat), and then return to ON. The blower will switch to the next higher speed. There are at least three speeds to choose from. If the blower is running on its highest speed, a request to change will direct the blower to return to its lowest speed,

SHUTTING DOWN YOUR FURNACE

Should you need to shut down your furnace for service or maintenance, you will need to turn the furnace off. The following procedures must be followed:
f. Set your room thermostat to the lowest temperature setting
and set the “MODE” to “OFF,” See Fig. 16,
4, Remove main furnace door. See Fig. 10, 3, Turn control switch on the gas control to OFF position. See
Fig. 19,
SINGLE-STAGE GAS CONTROL
Fig. 19 - Control Switch to OFF
6, Replace main furnace door. See Fig. 13, 7, If the furnace is being shut down because of a malfunction, call
your dealer as soon as possible.
TWO STAGE GAS CONTROL

A. CAUTION

2, Close the external manual gas valve. See Fig. 17,
Fig. 17 - Close the External Manual Valve
3, Turn off electrical supply to the furnace. See Fig. 18,

UNIT AND PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in unit component or property damage.
Furnace is not to be installed, operated, and then turned off and left turned off in an unoccupied structure during winter. See “Winterization” procedures in this manual.

PERFORMING ROUTINE MAINTENANCE

NOTE: The qualified installer or agency must use only
factory-authorized replacement parts, kits, and accessories when modifying this product.
Installing and servicing of heating equipment can be hazardous due to gas and electrical components.
Only trained and qualified personnel should install, repair, or service heating equipment. Untrained personnel can perform basic maintenance functions such as cleaning and replacing air filters.
All other operations must be performed by trained service personnel. Observe safety precautions in this manual, on tags, and on labels attached to the furnace and other safety precautions that may apply.
With proper maintenance and care, your furnace will operate economically and dependably. Instructions for basic maintenance are found on this and the following pages. However, before beginning maintenance, follow these safety precautions:
Fig. 18 - Turn Off Electrical Supply

^ WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace and install lockout tag before removing the access doors to service or perform maintenance.

A CAUTION

CUT HAZARD

Failure to follow this caution may result in personal injury.
Although special care has been taken to minimize sharp
edges, be extremely careful when handling parts or reaching into the furnace. Wear safety glasses, gloves, and appropriate protective clothing.

FILTERING OUT TROUBLE

NOTE: The manufacturer has specified filters which will enable
your furnace to provide lasting comfort and efficiency throughout its life. Contact your dealer to help you choose filters for your furnace that both collect dirt before it enters your furnace, as well as provide a low resistance to circulating air. Avoid filters that report high cleaning efficiencies, but do not allow air to pass easily through them.

^ CAUTION

UNIT PERFORMANCE HAZARD

Failure to follow this caution may result in unit component damage.
Never operate your furnace without a filter in place. Doing so may damage the furnace blower motor. An accumulation of dust and lint on internal parts of your furnace can cause a loss of efficiency.
a. Remove filter cabinet door. (See Fig. 21 and 22.)
NOTE: It may be necessary to remove one thumbscrew.
b. Slide air filter out of furnace. Keep dirty side up (if
dirty) to avoid spilling dirt.
3. Inspect the filter. If torn, replace it.
NOTE: If a washable filter was supplied with the furnace and has been replaced by:
Disposable media filter--Do not clean. If dirty, replace only with media filter having the same part number and size. Install with airflow direction arrow pointing to wards blower.
Electronic Air Cleaner (EAC), refer to the EAC Owner’s Manual for maintenance information.
4. If washable filter, wash filter (if dirty) in a sink, bathtub, or outside with a garden hose. Always use cold tap water. A mild liquid detergent may be used if necessary. Spray water through filter in the opposite direction of airflow. Allow fil ter to dry.
3. Reinstall clean air filter.
6. Turn on electrical supply to the furnace.
If your furnace air filter needs to be replaced, be sure to use a factory-authorized filter of the same size that was originally specified. Use the filter tables and compare your furnace size with the proper filter size.

A, CAUTION

PERSONAL INJURY HAZARD

Failure to follow this caution may result in personal injury. Use care when cutting support rods in filters to protect against
flying pieces and sharp rod ends. Wear safety glasses, gloves, and appropriate protective clothing.
A dirty filter will cause excessive stress on the furnace, heat
exchanger, and blower motor, and can cause it to overheat and automatically shut down. The furnace filter should be checked every four weeks and be cleaned or replaced if necessary.
If installed with factory-specified disposable media filter, check or replace filter before each heating and cooling season. Replace disposable media filter at least once a year.
If your furnace filter needs replacing, be sure to use the same size and type of filter that was originally specified.
The air filter for the furnace may be located in an external filter cabinet attached to the side or bottom of the furnace casing. If the air filter has been installed in another location, contact your dealer for instructions. To inspect, clean and/or replace the air filter(s), follow these steps:
1. Turn off electrical supply to the furnace. See Fig. 20.
2. Remove air filter from the filter cabinet.
Fig. 21
Fig. 20 - Turn Off Electrical Supply
A0022S
Removal of Filter Cabinet Door from Side Blower
Cabinet
Fig. 22 - Removal of Filter Cabinet Door from Bottom
Blower Cabinet
Fig. 23
Removal of Filter from Side Blower Cabinet
A00226
A00227
Fig. 24 - Removal of Filter from Bottom Blower Cabinet
A00229
Fig. 25 - Replacement of Filter Cabinet Door to Side Blower
Cabinet
Fig. 26 - Replacement of Filter Cabinet Door to Bottom Blower Cabinet
Table 1 - Air Filter Located in Filter Cabinet
FILTER CABINET HEIGHT - IN (MM) FILTER SIZE - IN (MM) FILTER TYPE
(1) 16x25x3/4*
16 (406)
20 (508)
24 (610)
* Filters with a side return-air may have a different filter size. Measure the filter to obtain the correct size,
t Recommended to maintain air filter face velocity. See Product Data for part number.
(406 X 635 X 19) or
(1) 16x25x4-5/16 (406 X 635 X 110)
(1) 20x25x3/4*
(508 X 635 X 19) or
(1) 20x25x4-5/16
(508 X 635 X 110)
(1) 24x25x3/4*or
(610 X 635 X 19) or
(1) 24x25x4-5/16
(610 X 635 X 110)
10
Washablet
Washablet
Washablet

COMBUSTION AIR AND VENT SYSTEM

A WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.
If holes are found or if the vent pipe is obstructed or is not connected, toxic fumes can escape into your home. DO NOT OPERATE YOUR FURNACE, Call your dealer for service.

A CAUTION

UNIT OPERATION HAZARD

Failure to follow this caution may result in intermittent unit operation.
For proper and safe operation the furnace needs air for combustion and ventilation. Do not block or obstruct air openings on the furnace, air opening to the area in which the furnace is installed, and the space around the furnace.
Fig. 27 - Gas Burner Assembly (Upflow)
Fig. 28 - Gas Burner Assembly (Downflow)
Visually inspect the combustion area and vent system before each heating season. Make sure that all PVC pipes leading into the combustion area and vent are free from any cracks and sags. An accumulation of dirt, soot, or rust can mean a loss of efficiency and improper performance. Buildups on the main burners can cause faulty firing. This “delayed ignition” is characterized by an alarmingly loud sound.
Check the combustion-air intake adjacent to the furnace or outside your home for blockage. Also check the vent pipe on the outside of your home for blockage.
NOTE: If your furnace makes a loud noise when the main burners are ignited, shut down the furnace and call your servicing dealer.
Use your flashlight and follow these steps for inspecting the combustion area and vent system of your furnace:

^ WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury or death.
If dirt, rust, soot, or scale accumulations are found, call your dealer. Do not operate your furnace.
1, Turn off electrical supply and gas supply to the furnace and
remove the main furnace door. See Fig. 7, 8, 9, 10 and 11,
3, Inspect the combustion-air and vent PVC pipes for sags,
holes, cracks, water leaks, blockage or disconnections. Hori zontal portions of vent pipe must slope downward toward the furnace.
4, If your furnace is free of the above conditions turn on elec
trical and gas supplies to the furnace.
3, Start your furnace and observe its operation. Watch the
burner flames to see if they are clear blue, almost transpar ent,, If you observe a suspected malfunction, or the burner flames are not clear blue, call your dealer.
6, Replace main furnace door.
Burner Flame
Burner
Manifold ^
Fig. 29 - Burner Flame Adjustment

^ WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace and install lockout tag before removing the access doors to service or perform maintenance.
2, Inspect the gas burners, igniter area, and remainder of fur
nace for dirt, rust, soot or scale.
If

WINTERIZATION

A CAUTION

UNIT AND PROPERTY DAMAGE HAZARD

Failure to follow this caution may result in unit component or property damage.
If the furnace is installed in an unconditioned space where the ambient temperatures may be 32° F (0° C) or lower, freeze protection measures must be taken to prevent minor property or product damage.
Since the furnace uses a condensing heat exchanger, some water
will accumulate in the unit as a result of the heat transfer process.
Therefore, once it has been operated, it cannot be turned off and left off for an extended period of time when temperatures will reach 32°F (0°C) or lower unless winterized. Follow these procedures to winterize your furnace:

A CAUTION

UNIT COMPONENT DAMAGE HAZARD

Failure to follow this caution may result in damage to the furnace and other property damage.
Do not use ethylene glycol (automotive antifreeze coolant or equivalent). Failure of plastic components may occur.
7, Pour 1 quart of anti-freeze solution into the funnel/tube.
Antifreeze should run through the inducer housing, overfill condensate trap and flow to an open drain,
8, If a condensate pump is used, check with pump
manufacturer to verify pump is safe for use with antifreeze used. Allow pump to start and pump anti-freeze to open drain,
9, Remove funnel and tube from collector box, 10, Replace plug in collector box. If, Remove the other plug and repeat steps 4-10, 12, Replace main door, 13, When furnace is re-started, flush condensate pump with
clear water to check for proper operation before re-starting furnace,
14, Propylene glycol need not be removed before re-starting
furnace.
1, Obtain propylene glycol (RV/swimming pool antifreeze or
equivalent),
2, Turn off gas and electrical supplies to your furnace.

^ WARNING

ELECTRICAL SHOCK HAZARD

Failure to follow this warning could result in personal injury or death.
Turn off electrical power supply to your furnace and install lockout tag before removing the access doors to service or perform maintenance.
3, Remove furnace control compartment door, 4, Remove one of the unused rubber plugs in the port on the
collector box opposite the condensate trap. See Fig 3f,
3, Connect a field supplied 3/8-in, (9,3-mm) ID tube to the
open port on the collector box
6, Insert a field supplied funnel into the tube.
12

A CHECK-UP CHECKLIST

Your furnace represents an important investment in your family’s
comfort and your home’s value. To keep it performing properly and to prevent future problems, have a trained service specialist give your furnace a professional check-up annually. The following checklist can be used as a guideline to proper service:
• Inspect all flue gas passages, burners, heat exchangers, coupling box(es), and inducer assembly.
• Inspect all combustion-air and vent piping inside structure and pipe terminations outside the structure,
• Check gas pipes leading to and inside of your furnace for leaks,
• Inspect and clean the blower motor and wheel.
NOTE: The inducer and blower motors are pre-lubricated and require no additional lubrication. These motors can be identified by the absence of oil ports on each end of the motor.
• Inspect and change or clean air filter(s) if necessary.
• Inspect all supply- and return-air ducts for obstructions, air leaks, and insulation. Remedy any problem when necessary,
• Inspect the return-air duct connection(s) at the furnace to ensure it is physically sound, sealed to the furnace casing, and terminates outside the space containing the furnace,
• Inspect electrical wiring, connections, and components for loose connections,
• Perform an operational checkout to determine whether your furnace is working properly and if it requires adjustments.
• Inspect all condensate drain tubes and condensate trap assembly for leaks. The condensate removal system should be cleaned
annually by a qualified service agency. Refer to the Service and
Maintenance Instructions Guide for further information,
• Examine the physical support of the furnace. Support should be sound with no cracks, sagging, gaps, etc, around the base,
• Check furnace for any obvious signs of deterioration.
Ask your servicing dealer for further details about an economical
service contract that covers seasonal inspections.
BEFORE YOU REQUEST A
“SERVICE CALL”
If your furnace is not operating or not performing properly, you may save the expense of a service call by checking a few things yourself before calling for service.
This furnace has a light emitting diode (LED) status code display to aid the installer, service technician, or homeowner while installing or servicing the unit. The LED code can be seen through the view port in the blower access panel.
NOTE: Record the LED status code BEEORE removing the blower access door or turning off f 13-v power to the furnace.
See the information booklet inside the main furnace door for a service code legend. See Fig. 3f,
Eor insufficient airflow:
• Check for dirty air filter(s).
• Check for blocked return-air or supply-air grilles. Be sure they are open and unobstructed.
If problem still exists, call your dealer for service.
If furnace fails to operate:
Follow this checklist step by step, advancing to the next stop only if furnace fails to start.
• Check thermostat for proper temperature. Is thermostat set above
room temperature?
• Is thermostat set to HEAT mode?
• Check fuses and circuit breakers. Is the electrical power supply
switch on?
• Is the manual shut-off valve in the gas supply pipe leading to
the furnace open?
NOTE: Turn off electrical supply before continuing with checklist,
• Is control switch on gas valve in ON position? (Follow start-up
procedures if you must reset switch to ON position.)
• Check manual reset rollout switch located on the burner box. See Furnace Components in Fig. 1, If furnace has experienced
high temperature conditions, this switch will shut off the furnace. Reset it by pushing the button on the switch. If it trips
again, shut down the furnace and call for service. See “Shutting
Down Your Furnace” section in this manual.
• Check for obstructions around the vent termination.
If your furnace still fails to operate, call your service representative. For your convenience, record the furnace product and serial
numbers on back page. Should you ever require service, you will have ready access to the information needed by your service representative.
13
NOTE TO EQUIPMENT OWNER:
For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information will be helpful
should your system require maintenance or service.

FURNACE

Model #_
Serial #

AIR CONDITIONER OR HEAT PUMP

Model #_____________________________
Serial #
_____________________________
INDOOR COIL (Furnace Coll or Fan Coll)
Model #_____________________________
Serial #
This manual must be left with the equipment owner.

INSTALLATION INFORMATION:

Date Installed

DEALERSHIP CONTACT INFORMATION:

Company Name Address_
Phone Number
Technician Name

NOTE TO INSTALLER:

______________________
Copyright 2011 Carrier Corp, • 7310 W, Morris St. • Indianapolis, IN 46231 Printed in U.S.A, Edition Date: 08/11
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. Replaces: OM9GFC-02
14
Catalog No: OM9GFC-03

Owner’s Manual

NOTE TO INSTALLER:
THIS MANUAL MUST BE LELT WITH THE
EQUIPMENT USER.
USER: PLEASE READ ALL INSTRUCTIONS IN THE MANUAL AND RETAIN ALL MANUALS LOR EUTURE REEERENCE.

A. WARNING

Failure to follow warnings could result in personal injury, death, or property damage.
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance,

WHAT TO DO IF YOU SMELL GAS

-Do not try to light any appliance,
-Do not touch any electrical switch; do not use any phone in your building,
-Leave the building immediately,
-Immediately call your gas supplier from a nearby
phone. Follow the gas supplier’s instructions,
-If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.

A WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to follow this warning could result in personal injury and/or death.
Carbon Monoxide is invisible, odorless, and toxic! Install a carbon monoxide alarm in your home, even if you do not own a gas appliance. Locate the carbon monoxide alarm in the living area of your home and away from gas appliances and doorways to attached garages. Follow the alarm manufacturer’s instruction included with the alarm.

A WARNING

ELECTRICAL OPERATION HAZARD

Failure to follow this warning could result in personal injury, death, or property damage.
Do not use this furnace if any part has been under water, A flood-damaged furnace is extremely dangerous. Attempts to use the furnace can result in fire or explosion, A qualified service agency should be contacted to inspect the furnace and to replace all gas controls, control system parts, and electrical parts that have been wet, or the entire furnace if deemed necessary.

TABLE OF CONTENTS

WELCOME TO A NEW GENERATION OF COMFORT
_______
FURNACE COMPONENTS..............................................................3
SAFETY CONSIDERATIONS .........................................................4
BEFORE STARTING YOUR FURNACE
........................................
STARTING YOUR FURNACE
SHUTTING DOWN YOUR FURNACE
PERFORMING ROUTINE MAINTENANCE
..........................................
................................
FILTERING OUT TROUBLE...........................................................9
COMBUSTION AREA AND VENT SYSTEM
WINTERIZATION
A CHECK-UP CHECKLIST
..........................................................................
...........................................................
............................
11
13
13
BEFORE YOU REOUEST A SERVICE CALL............................. 13
INSTALLATION DATA................................................................. 14
2
3
7
8
Always Ask For
WELCOME TO TODAY’S GENERATION
OF COMFORT
Congratulations! In light of rising energy costs, a 90+% AFUE Condensing Gas Furnace from Carrier Corporation is among the soundest investments today’s homeowner can make.
Your new furnace is truly a triumph of technology in home
heating. A revolutionary design employs two heat exchangers to “squeeze” out the maximum amount of heat from the fuel consumed. In fact, your new furnace is so efficient, over 90%* of the heat generated during combustion is captured and delivered inside your home.
This furnace is among the safest, most dependable, energy-efficient furnaces you can buy today. We are proud of the technological advances incorporated into the design of this furnace. With only minimal care, your new furnace will deliver many years of money-saving home comfort and enjoyment. Spend just a few minutes with this manual to learn the operation of your new furnace and the small amount of maintenance it takes to help keep it operating at peak efficiency year after year.
* The output capacity and any representations of efficiency for this furnace are based on standard U.S. Department of Energy test procedures.
A1‘ |>\iïïS
Use of the AHRI Certified
TM Mark indicates a
manufacturer's participation in the program For verification of certification for individual products, go to
www.ahridirectory.org.

A. WARNING

ELECTRICAL SHOCK, EIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in dangerous operation, serious injury, death, or property damage.
Improper servicing could result in dangerous operation, serious injury, death or property damage.
Before servicing, disconnect all electrical power to furnace.
When servicing controls, label all wires prior to discon necting. Reconnect wires correctly.
Verify proper operation after servicing.
(Furnace shown in iipflow position; may be used in downflow or horizontal orientation or applications.
MANUAL RESET ROLLOUT SWITCH
OPERATING INSTRUCTIONS NOT SHOWN (LOCATED ON MAIN FURNACE DOOR, SEE OPERATING INSTRUCTIONS
INSIDE DOOR FIGURE).
ELECTRICAL JUNCTION BOX (IF REQUIRED, LOCATION MAY VARY)

FURNACE COMPONENTS

HOT SURFACE
GAS BURNER
IGNITER
MANUAL RESET ROLLOUT SWITCH
MAIN LIMIT SWITCH
- (BEHIND GAS VALVE)
INDUCER MOTOR
ASSEMBLY
BLOWER DOOR SAFETY SWITCH
RATING PLATE NOT SHOWN
(LOCATED ON BLOWER DOOR)
MEDIA CABINET
BLOWERAND
‘MOTOR
CAPACITOR/ POWER CHOKE
REPRESENTATIVE DRAWING ONLY, SOME MODELS MAY VARY IN APPEARANCE.
Fig. 1 - Furnace Components