Carrier Base 24ABA3, Base 24ABA360A30, Base 24ABA348A30, Base 24ABA342A30, Base 24ABA336A30 Product Data

...
24ABA3 BasetSeries 13 Air Conditioner with Puronr Refrigerant
Product Data
the environmentally sound refrigerant
Carrier’s Air Conditioners with Puronr refrigerant provide a collection of features u nm atched by any other family o f equipment. The 24ABA has been designed utilizing Carrier’s Puron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer. Carrier’s air conditioning system with Puron refrigerant meets the Energy Star r guidelines for energy efficiency.
A04030
INDUSTRY LEADING FEATURES / BENEFITS
Efficiency
13 SEER/11 EER
S S
Microtube Technologyt refrigeration system
S
Indoor air quality accessories available
Sound
Sound level as low as 76 dBA
S
Comfort
System supports Thermidistatt or standard thermostat
S
controls
Reliability
S
Puronr refrigerant -- environmentally sound, won’t deplete the ozone layer and low lifetime servce cost.
S
Front--seating service valves
S
Scroll compressor
S
Internal pressure relief valve
S
Internal thermal overload
S
Filter drier
S
Balanced refrigeration system for maximum reliability
Durability
WeatherArmort protection package:
S
Solid, Durable sheet metal construction
S
Dense wire coil guard
S
Baked--on, complete coverage, powder paint
Applications
Long--line -- up to 250 feet total equivalent length, up
S
to 200 feet condenser above evaporator, or up to 80 ft. evaporator above condenser (See Longline Guide for more information.)
S
Low ambient (down to --20_F) with accessory kit
Warranty
5 year limited compressor warranty
S S
5 year limited parts warranty
MODEL NUMBER NOMENCLATURE
12 3 4 5 6 78 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
24 A B A 3 36 A 0 0 3 0
Product
Series
24=AC A=RES AC B=Base A=Puron 3=13 SEER A=Standard
Product
Famil y
the environmentally sound refrigerant
Tier
Major
Series
SEER
T
O
D
E
A
I
R
F
I
I
T
R
E
C
R
A
I
R
E
C
R
O
Y
U
R
A
T
T
I
C
N
A
U
F
U
N
A
M
E
T
Q
N
U
E
I
P
M
A
R
I
S
D
T
A
R
N
A
D
Cooling
Capacity
A
S
C
O
M
P
L
N
D
Y
I
T
I
N
I
O
G
N
I
N
W
G
I
T
H
0
1
2
Variations Open Open Voltage Series
0=Not
Defined
ISO 9001:2000
REGISTERED
0=Not
Defined
3=208/230--- 1
24ABA3
STANDARD FEATURES
Feature 18 24 30 36 42 48 60
Puron Refrigerant X X X X X X X
13 SEER X X X X X X X
Scroll Compressor X X X X X X X
DenseWireCoilGuard X X X X X X X
FieldInstalledFilterDrier X X X X X X X
Front Seating Service Valves X X X X X X X
Internal Pressure Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
0=
Original
Series
2
PHYSICAL DATA
UNIT SIZE SERIES 18 24 30 36 42 48 60
Operating Weight (lb) 125 125 134 152 189 210 236
Shipping Weight (lb) 146 146 155 175 218 235 270
Compressor Type Scroll
REFRIGERANT Puron® (R--- 410A)
Control TXV (Puron® Hard Shutoff)
Charge (lb) 4.25 4.35 4.75 5.25 6.2 8.35 8.75
COND FAN Propeller Type, Direct Drive
Air Discharge Vertical
Air Qty (CFM) 1880 2200 2200 2950 3170 3365 4050
Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/5
Motor RPM 1100 1100 1100 1100 1100 1100 825
COND COIL
Face Area (Sq ft) 9.85 9.85 11.49 14.77 17.25 21.56 25.15
Fins per In. 20 20 25 25 25 25 25
Rows 1 1 1 1 1 1 1
Circuits 3 3 3 3 4 5 5
VALVECONNECT.(In.ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8
Liquid 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
REFRIGERANT TUBES* (In. OD)
Vapor (0 --- 80 Ft Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8
Liquid (0--- 80 Ft Tube Length) 3/8”
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
24ABA3
VAPOR LINE SIZING AND COOLING CAPACITY LOSS PURON 1--STAGE AIR CONDITIONER APPLICATIONS
LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft or when there is more than 20 Ft vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250Ft. The maximum vertical separation is 200 Ft when outdoor
Unit Nominal Size
(Btuh)
18000
1StagePuronAC
24000
1StagePuronAC
30000
1StagePuronAC
36000
1StagePuronAC
42000
1StagePuronAC
48000
1StagePuronAC
60000
1StagePuronAC
Acceptable
Vapor Line
Diameters
(In. OD)
1/2 1 2 4 4 5 6 7 8 10 11 12 5/8 0 1 1 1 2 2 2 3 3 3 4 5/8 1 1 2 2 3 3 4 4 5 6 6
3/4 0 1 1 1 1 1 1 2 2 2 2 7/8 0 0 0 0 1 1 1 1 1 1 1 5/8 1 2 3 3 4 5 6 7 8 9 9 3/4 0 1 1 1 1 2 2 3 3 3 4 7/8 0 0 1 1 1 1 1 1 1 2 2 5/8 1 3 4 4 5 7 8 9 11 12 13 3/4 1 1 2 2 2 3 3 3 4 4 5 7/8 0 1 1 1 1 1 2 2 2 2 3 3/4 1 1 2 2 3 3 4 5 5 6 7 7/8 0 1 1 1 1 2 2 2 3 3 3
11/8 0 0 0 0 0 1 1 1 1 1 1
3/4 1 2 3 3 3 4 5 6 7 8 8 7/8 0 1 1 1 2 2 3 3 3 4 4
11/8 0 0 0 0 1 1 1 1 1 1 1
3/4 1 3 4 4 5 6 8 9 10 11 13 7/8 1 1 2 2 3 3 4 4 5 6 6
11/8 0 0 1 1 1 1 1 1 1 2 2
Standard Application Long Line Application Requires Accessories
25 50 80 80+ 100 125 150 175 200 225 250
Standard Length = 80 Ft or less total equivalvent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
unit is above indoor unit, and up to 80 Ft when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long--Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss.
Cooling Capacity Loss (%)
Total Equivalent Line Length (ft)
3
ACCESSORY THERMOSTATS
THERMOSTAT / SUBBASE PKG. DESCRIPTION
TSTATCCPRH01--- B Thermidistat Control --- Programmable / Non ---Programmable Thermostat with Humidity control
TSTATCCPAC01---B Th e r mo s t at --- A u to C h a n g e o v e r, 7 --- D ay P r o g r a m m a b l e, _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATCCNAC01--- C T h er m o st a t --- A u t o C h a n g e o v er, N o n --- P r o g r a mm a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S ta g e C o o l
TSTATCCBAC01--- B Builder’s Thermostat --- Manual Changeover, Non---Programmable, _F/_C , 1 --- S t a ge H e a t , 1 --- S t a g e C o ol
TSTATCCSEN01--- B Outdoor Air Temperature Sensor
TSTATXXBBP01 Backplate for Builder’s Thermostat
TSTATXXNBP01 Backplate for Non --- Programmable Thermostat
TSTATXXPBP01 Backplate for Programmable Thermostat
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack
ACCESSORIES
KIT NUMBER DESCRIPTION
KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X
KAATD0101TDR TIME DELAY RELAY X X X X X X X
KAAWS0101AAA WINTER START X X X X X X X
KSALA0301410 LOW AMBIENT PSW X X X X X X X
24ABA3
KSALA0601AAA MOTORMASTER 230V X X X X X X X
KSALA0701AAA MOTORMASTER 460V
HC32GE234 MOTOR FAN BALL BEARING X
HC34GE239 MOTOR FAN BALL BEARING X X
HC40GE226 MOTOR FAN BALL BEARING X X
HC38GE219 MOTOR FAN BALL BEARING X
HC40GE228 MOTOR FAN BALL BEARING X
KSAHS1701AAA HARD START (CAP / RELAY ) X X X X X X X
KSACY0101AAA CYCLE PROTECTOR X X X X X X X
KSASF0101AAA SUPPORT FEET X X X X X X X
KAACS0201PTC START ASSIST PTC X X X X X X X
KAACH1201AAA CRANKCASE HTR X X X
KAACH1401AAA CRANKCASE HTR X X X X
KAACH1501AAA CRANKCASE HTR
KSATX0201PUR TXV PURON HSO X X X
KSATX0301PUR TXV PURON HSO X X
KSATX0401PUR TXV PURON HSO X
KSATX0501PUR TXV PURON HSO X
KSASH0601COP SOUND HOOD X X X X X X
KSASH2101COP SOUND HOOD X
KAALP0301PUR LOW PRESSURE SWITCH X X X X X X X
KAAHI0401PUR HIGH PRESSURE SWITCH X X X X X X X
18-- -30 24- -- 30 30 --- 30 36 --- 30 42 --- 30 48 ---30 60 ---30
Size --- Voltage & Series
ACCESSORY USAGE GUIDELINE
ACCESSORY
Crankcase Heater Ye s Yes No
Evaporator Freeze Thermostat Yes No No
Accumulator No No No
Compressor Start Assist Capacitor and Relay Yes Ye s No
Motor Master®Control or Low---ambient
Pressure Switch
Support Feet Recommended No Recommended
Liquid Line Solenoid Valve No
Ball Bearing Fan Motor Yes { No No
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differntial, refer to Residential Split---System Longline Application Guideline. { Required for Low ---Ambient Controller (full modulation feature) an d MotorMasterr Control only.
Accessory Description and Usage (Listed Alphabetically)
REQUIRED FOR LOW---AMBIENT
COOLING APPLICATIONS (Below 55°
F)
Yes No No
4
REQUIRED FOR
LONG LINE
APPLICATIONS*
(Over 80 Ft.)
S e e L o n g --- L in e A p -
plication Guideline
REQUIRED FOR
SEA COAST APPLICATIONS (Within 2 miles)
No
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMasterr —
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.
Usage Guideline: Required for reciprocating compressors in the
following applications:
Long line Low ambient cooling
Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications. Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5 -- minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature-- actuated switch that stops unit operation when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when low ambient kit has been added.
7. Low--Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-- ambient temperatures down to 0_F when properly installed.
Usage Guideline:
A Low -- Ambient Pressure Switch or MotorMasterr
Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
8. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ±
-- 1 2 _C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
Suggested for all commercial applications.
9. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this publication.
10. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.
Usage Guideline: Suggested when unit is installed closer than 15 ft to
quiet areas, bedrooms, etc. Suggested when unit is installed between two houses less
than 10 ft apart.
11. Support Feet
Four stick--on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.
Usage Guideline: Suggested in the following applications: Coastal installations.
Windy areas or where debris is normally circulating. Rooftop installations.
For improved sound ratings.
12. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available.
NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required.
Usage Guideline:
Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings.
Hard shut off TXV or LLS required in air conditioner long line applications.
Required for use on all zoning systems.
12. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Accessory Description and Usage (Listed Alphabetically) (Continued)
24ABA3
5
13. Winter Start Control
This control is designed to alleviate nuisance opening of the low--pressure switch by bypassing it for the first 3 minutes of operation.
ELECTRICAL DATA
UNIT SIZE
18
24 58.3 13.5 0.75 17.6 14 14 45 43 25
30 64.0 12.8 0.75 16.8 14 14 47 45 25
36 77.0 14.1 1.4 19.0 12 12 66 63 30
42 112.0 17.9 1.1 23.5 12 12 53 51 40
48 109.0 19.9 1.4 26.2 10 10 76 73 40
60 134.0 26.4 1.2 34.2 8 8 91 86 50
* Permissibl e limits of the voltage r ange at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30˚ C(86˚ F), consult table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of non ---metallic---sheathed cable
(NM), trade name ROMEX, shall be that of 60˚ C (140˚ F) conditions, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (no---plated), 60
24ABA324ABA3
or 75˚ C (140 or 167˚ C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time---Delay fuse.
FLA --- F u l l L oad A m p s LRA --- L o c k e d Ro t o r A m p s MCA --- Minimum Circuit Amps RLA --- RatedLoadAmps
NOTE: Control circuit is 24 --- V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
V/PH
208/230/1 253 197
All motors/compressors contain internal overload protection.
OPER
VOLTS*
MAX MIN LRA RLA FLA 60° C 75° C 60° C 75° C
COMPR FAN
MCA
48.0 9.0 0.5 11.7 14 14 67 64 15
MIN WIRE
SIZE{
MIN WIRE
SIZE{
MAX
LENGTH
(FT)}
MAX
LENGTH
(FT)}
A--WEIGHTED SOUND POWER (DBA)
UNIT
STANDARD
SIZE
18 76 52.0 61.0 67.0 70.5 67.5 63.5 56.5
24 76 56.5 64.0 67.5 69.5 67.0 65.0 60.5
30 76 55.0 63.5 69.0 72.0 69.0 64.5 59.5
36 76 58.5 64.0 68.0 69.5 66.0 62.5 55.0
42 78 57.5 65.0 71.0 73.0 70.5 67.5 62.5
48 78 59.5 67.0 72.5 73.0 70.0 67.0 62.5
60 78 53.5 61.0 67.5 74.5 68.5 62.5 61.0
RATING
125 250 500 1000 2000 4000 8000
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
MAX
FUSE**
or CKT
BRK
AMPS
A--WEIGHTED SOUND POWER (DBA) WITH ACCESSORY SOUND HOOD
UNIT SIZE
STANDARD
RATING
18 74 50.0 61.5 64.5 66.5 64.0 61.0 54.5
24 75 58.0 65.5 69.0 70.5 68.0 65.0 59.0
30 76 56.5 64.0 69.5 71.5 69.0 64.5 58.0
36 76 58.5 64.5 68.5 69.5 67.0 63.5 58.5
42 77 57.5 65.0 70.5 72.0 70.0 67.0 62.0
48 77 59.5 67.0 72.0 72.0 69.5 66.5 62.0
60 77 53.0 61.0 66.5 73.0 66.0 60.5 57.5
125 250 500 1000 2000 4000 8000
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE --- VOLTAGE & SERIES REQUIRED SUBCOOLING (_F)
18--- 30 8
24--- 30 13
30--- 30 16
36--- 30 16
42--- 30 10
48--- 30 17
60--- 30 11
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
6
24ABA3
1. Allow 30” clearance to service side of unit, 48” above unit, 6” on one side, 12”
on remaining side, and 24” between units for proper airflow.
2. Minimum outdoor operating ambient in cooling mode is 55 _F, max. 125_ F.
(Professional Engineer), if required.
3. Series d esignation is the 13th position of the unit model number.
4. Center o f gravity
5. For hurricane tie downs, contact distributor for details and PE Certification
A B C D E F G H J K L M N P
X=YES
0=NO
ELECTRI CAL
CHARACTERISTICS
UNIT SERIES
24ABA318 0 X 0 0 0 25 3/4” 25 1/8” 33/4” 5/8” 4 7/16” 21 1/4” 91/8” 5/16” 3” 2 13/16” 1/2” 12 1/2” 12 3/8” 12 3/8”
24ABA324 0 X 0 0 0 25 3/4” 25 1/8” 33/4” 5/8” 4 7/16” 21 1/4” 91/8” 5/16” 3” 2 13/16” 1/2” 13” 11 7/8” 12 3/8”
24ABA330 0 X 0 0 0 25 3/4” 28 1/2” 33/4” 3/4” 4 7/16” 21 1/4” 91/8” 5/16” 3” 2 13/16” 1/2” 12 1/4” 13 3/4” 12 3/4”
24ABA336 0 X 0 0 0 25 3/4” 35 5/16” 33/4” 3/4” 4 7/16” 21 1/4” 91/8” 5/16” 3” 2 13/16” 1/2” 12” 13” 14 3/4”
24ABA342 0 X 0 0 0 31 3/16” 32 7/16” 37/8” 7/8” 6 9/16” 24 11/16” 91/8” 5/16” 3” 2 15/ 16” 5/8” 16 1/4” 16 1/4” 13 3/4”
24ABA348 0 X 0 0 0 31 3/16” 39 1/4” 37/8” 7/8” 6 9/16” 24 11/16” 91/8” 5/16” 3” 2 15/ 16” 5/8” 17 1/4” 17 1/4” 19 3/4”
DIMENSIONS
24ABA360 0 X 0 0 0 35” 39 1/4” 37/8” 7/8” 6 9/16” 28 7/16” 91/8” 5/16” 3” 2 15/ 16” 5/8” 19 3/4” 19 3/4” 18 3/8”
4 6 0 --- 3 --- 6 0
208/230--- 3 ---60
2 3 0 --- 1 --- 6 0
2 0 8 --- 2 3 0 --- 1 --- 6 0
PAD DIMENSIONS
MINIMUM MOUNTING
60 35” X 35”
42, 48 31 1/2” X 31 1/2”
UNIT SIZE
18, 24, 30, 36 26” X 26”
7