Carrier 592-085 User Manual

ARCHITECTS AND ENGINEERS’ MANUAL
PREMIER SERIES 52P
COMFORT SERIES 52C
PACKAGED TERMINAL
AIR CONDITIONERS
AND HEAT PUMPS

CONTENTS

Page
APPLICATIONS
Retrofit/Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ApplicationConsiderations ......................4
PRODUCT OVERVIEW .......................5
PRODUCT FEATURES AND BENEFITS ....6-13
QuietOperation ...............................6
MostEfficientPerformance......................6
EfficientFanMotor ............................6
No-Rust Weather Last™ Wall Sleeve and
FrontPanel .................................7
RemovableFrontPanel .........................7
Anti-TheftKnobs..............................7
Two-PieceLifetimeIndoorFilter..................8
Washable Vent Air Filter . . . . . . . . . . . . . . . . . . . . . . . . 8
Bi-Directional Discharge Grille . . . . . . . . . . . . . . . . . . . 8
PowerCordfor265-VUnits .....................9
Power Cord Protection for 230/208-V Units . . . . . . . . . 9
Bi-MoldedCondenserShroud....................9
SnowBaffle ..................................9
Easy Access to Chassis. . . . . . . . . . . . . . . . . . . . . . . . . 10
HiddenControls..............................10
EnhancedCopperTubing.......................11
............................ 3,4
Page
SeamlessBasepan ............................11
CondensateDrainValve........................11
CondensateRemovalSystem....................11
HeatPumpsPayTheirOwnWay.................12
HeatPumpEnergySavings.....................13
ORDERING DATA ...........................14
ProductCatalogNumber.......................14
FACTORY-INSTALLED OPTIONS ...........15
FIELD-INSTALLED ACCESSORIES ...... 16-26
DIMENSION DRAWINGS AND INSTALLATION DATA — NEW CONSTRUCTION
PRODUCT DATA ......................... 34-41
EXPANDED RATINGS DATA...............42,43
SOUND DATA ...............................44
WIRING DIAGRAMS ..................... 45-50
52PQand52CQ............................45,46
52PEand52CE ............................47,48
EnergyManagement/FrontDeskControl ..........49
Single Thermostat/Multiple PTAC Units . . . . . . . . . . . 50
GUIDE SPECIFICATIONS ................ 51-53
TYPICAL WARRANTY ....................54,55
ACCESSORY LIST ..........................56
......................... 27-33
For more information available on the internet, see the www.carrier.com or www.lodgingAC.com web sites.
December 2004 CopyrightCarrier Corporation Cat. No. 592-085
Valued Carrier Customer,
Carrier’s Architects and Engineer’s manual has been specifically developed to make your product and accessory selection easier and faster. This manual will help you customize your application to ensure the greatest comfort for your guests and the highest reliability and lowest costs for you.
Enjoy the ultimate in comfort, humidity control, and energy savings with Carrier’s com­plete line of Packaged Terminal Air Conditioning (PTAC) products. Choose from either the Premier series (52P) which is Carrier's most energy efficient PTAC unit ever, or the Comfort series (52C) for mid-range energy efficiency and outstanding value.
The Premier and Comfort series PTAC lines have many common features and benefits. The 52P and 52C units are both built on the same platform with common components and airflow systems to ensure the highest quality product for your money. The most significant difference between the 52P and 52C products is the refrigerant system. The Premier refrig­erant system utilizes Carrier's highest efficiency compressors and coil design to achieve maximum energy efficiency. The Comfort refrigerant system uses our standard efficiency compressors and coils to attain competitive efficiency levels which exceed the industry standard ARI minimum-efficiency levels.
It’s your choice. Choose the Premier series and start recovering your investment immedi­ately through energy savings, or choose our Comfort series and enjoy years of economical, trouble-free operation and comfort.
Thank you for choosing Carrier and investing in the highest quality air conditioning and heating system ever.
Best regards,
Lodging Products Group
2

APPLICATIONS

Whether you are designing a new structure or replac­ing packaged terminal air conditioning units in an existing building, Carrier will meet your needs.
• Hotels and motels
• Nursing homes and assisted living care centers
•Offices
• Apartments
• Single-family dwellings
• Home conversions and residential add-ons
NEW CONSTRUCTION
The Carrier 52P and 52C Packaged Terminal Air Con­ditioning (PTAC) unit is designed to meet the needs of the architect, engineer, and contractor. For unit instal­lation, Carrier’s expert support network will assist in all applicable aspects of the construction project, from preparing a budget to start-up.
ADVANTAGES FOR NEW CONSTRUCTION Design Flexibility For The Architect/Engineer
• Super-quiet performance, indoors and out
• No bulky duct system
• No separate equipment room
• No water towers or additional cooling equipment
• No complex match-up of different HVAC components
• Less sensitivity to building orientation (sun, wind, shade)
• Optional architectural grille to permit custom exte­rior appearance
Initial Cost Savings For The Building Owner
• No expensive component HVAC system purchase
• No equipment room or maintenance engineering staff
• Two-part delivery to minimize on-site damage
• Weather-protected wall sleeve that goes in place during construction; chassis that slides in place after construction
• No seasonal changeover required for cooling or heating — units are self-contained comfort systems
Lower Operating Costs And Reliable Comfort For The Occupant
• Heat pump models offer substantial savings over models with conventional electric resistance heaters
• Individual units allow tenants to choose the degree of comfort and operating economy.
• Rapid servicing reduces downtime: complete chas­sis can be replaced in minutes without disrupting other occupants.
• Each unit operates independently of other units in the building. No dependency by building on central HVAC system.
RETROFIT/REPLACEMENT
If you are replacing a unit in an existing wall sleeve, your options include:
• Replace the existing wall sleeve with a Carrier Weather Last™ sleeve. See accessory sleeve sec­tion for selecting the correct sleeve for your appli­cation. Note, in most cases, when replacing the wall sleeve, the exterior grille must also be replaced.
• Use an existing sleeve and exterior grille. The Carrier 52P and 52C series PTAC will fit into most major competitors wall sleeves/grilles, including GE, Amana, Trane, Bryant, Carrier 52S and Carrier 52B, and NO accessory retrofit kit is required. Carrier units will also retrofit into Friedrich T series and ZoneAire wall sleeves, with a required wall sleeve extension (see accessory Friedrich Retrofit Wall Sleeve Adapter).
IMPORTANT: All other sleeve or exterior grille retrofit applications need prior approval from Carrier. Please contact your Carrier representative for assistance.
CARRIER WARRANTY
Carrier’s five-year warranty is the most comprehen­sive in the industry. Carrier provides:
• Full coverage for parts and labor for first year.
• Four additional years of full coverage on sealed refrigeration systems.
• Limited second through fifth year coverage on non­refrigeration system parts.
3
APPLICATIONS (cont)
APPLICATION CONSIDERATIONS
Installation instructions are shipped with all PTAC units. It is important that air conditioning systems be properly sized and installed for each application in order to achieve the desired temperature and humidity levels within the space to be conditioned. It is strongly recommended that a professional engineer match the PTAC units with the building structure and climate.
The following application considerations are all important in choosing the proper PTAC system for the building structure.
Undersizing
If a PTAC unit is undersized (cooling capacity is less than required capacity for an application), the unit will not be able to cool the space down to the desired tem­perature during very hot days. The result could be warm and humid or warm and dry conditioned space.
Oversizing
If a PTAC unit is oversized (cooling capacity is greater than required capacity for the specific application), the unit will cool the space down to the desired tempera­ture too quickly.
The unit will cycle on and off, however, dehumidifica­tion only takes place when the unit is operating. The result of this type of application in a hot and/or humid climate would be a cool, yet excessively humid, space.
Air Infiltration
Excessive air infiltration can intensify problems asso­ciated with undersizing or oversizing a PTAC unit. This can be the cause of insufficient cooling, dehumid­ification, or heating. Sources of air infiltration include vents, gaps around windows and doors, and improp­erly sealed floors, ceilings or wall joints.
4

PRODUCT OVERVIEW (52P AND 52C)

This section summarizes product features covered in detail in later sections of this manual:
2 AIR FILTERS
LOUVERED FRONT PANEL
2-WAY BI-MOLDED DISCHARGE GRILLE
CONTROL DOOR
WIRE SCREEN
FRESH AIR CONTROL ARM
CONDENSER SHROUD
T
E
1
S
.P
R
T
E
S
2
S
IN
.P
R
L
E
U
S
G
G
E
T
IN
R
B
TO
E
U
C
T
E
P
T
3
P
O
O
.P
T
W
N
A
R
.
E
C
E
R
L
S
E
S
.
S
T
H
E
O
ST
U
4. L
B
D
U P R
T L IG
T
E
O
SS
H
N
T
F
.
U
R
O
N
E
R
S
IT
D
E
U
O
T
S
N
E
B
.
O
U
T
T
T
U
O
S
N
E
A
I S
G
A
T
I
E
N
S
T A
B O
V
E
F A
I L S
PLUG TEST/ RESET BUTTONS
THERMOSTAT WITH TEMPERATURE LIMITER
ACCESS TO ELECTRICAL INDOOR COIL
COMPONENTS THROUGH
CONTROL BOX DOOR
MODE SELECTION SWITCH
BASEPAN FOR CONDENSATE REMOVAL
COPPER TUBE ALUMINUM FIN COILS
ROTARY COMPRESSORS
WALL SLEEVE
Polymer, Metal or Extended Wall Sleeve — Designed for rugged duty, acoustic absorption, and attractive appearance for years to come.
Rotary Compressors — Provide quiet, reliable operation.
Copper Tube Aluminum Fin Coils — Enhanced coils provide durability, high performance, and ease of operation.
Fresh Air Control Arm — Allows outdoor air into room through vent filter for improved air quality.
Fan Cycle Switch — Dual options:
(1) Continuous fan operation. (2) Cycle fan ON and OFF with compressor operation.
Thermostat with Temperature Limiter — Provides improved temperature control with a temperature limiter that allows tempera­ture range restraints for the unit by making a simple adjustment.
Anti-Theft Knobs — Provides protection against theft of the thermostat knob and the mode selection knob.
Control Door — Provides protection for controls and enhances appearance.
Easy Access to Electrical Components — Simply remove two screws and drop down the control box door.
Improved Condensate Removal — Minimizes condensate water on outside of building.
New Two-Piece Filter Design — Provides improved air filtration and can be removed easily for cleaning.
Durable Discharge Grille — Made of polycarbonate; holds up under the toughest conditions.
Louvered Front Panel — Made of high impact polystyrene. Provides improved performance and quiet operation.
Mode Selection Switch — Rotary switch allows for easy selection of operating mode.
Bi-Molded Condenser Shroud — The two-piece condenser shroud allows easy access for service and maintenance to the out-
door coil and other components.
Power Cord Protection — Power cord for the 230/208-v unit provides power cord protection.
5

PRODUCT FEATURES AND BENEFITS (52P AND 52C)

The 52P and 52C models are a single-package, through-the-wall unit for heating and cooling hotel rooms, offices, apartments, condominiums, and resi­dential additions. Features include:
• Improved sound quality for quiet operation
• Exceeds ARI (Air Conditioning and Refrigeration Institute) efficiency requirements with exceptional energy efficiency ratios (EERs)
• Easy access, lifetime filters
• User friendly controls
• Easytoreaddials
• Enhanced temperature and humidity control
• Improved condensate removal system
• Multi-room structure design
• Fixed wall sleeve, slide-out chassis
• Attractive, durable cabinet featuring new design
• Chassis that easily retrofits to most major competi­tors’ sleeves without use of retrofit kit
• Low operating costs
• No bulky duct system
• No seasonal changeover
QUIET OPERATION
Occupants and neighbors are protected against noise intrusion. Indoor sound reduction is achieved because of the unit’s design and its louvered front cover, indoor scroll and blower, and heavy gage unit partition. Rotary compressors provide quiet, reliable operation. The indoor scroll provides a more uniform air discharge.
The new aerodynamic split condenser shroud design improves airflow and reduces outdoor noise, providing a more relaxing outdoor environment. The new split design allows for easy access to the outdoor coil to facilitate routine cleaning of the coil. The propeller-type fan design allows for efficient low-speed operation.
MOST EFFICIENT PERFORMANCE
High EERs provide excellent operating economy. The system operates without bulky ductwork, separate equipment room, and complex match-up of different components. Heating and Cooling modes are available without seasonal changeover.
EFFICIENT FAN MOTOR
An efficient, totally enclosed PSC (permanent split capacitor) fan motor provides a choice of high or low speeds for heating and cooling. A fan-only setting provides air circulation. Thefanmotorrequiresno maintenance and no lubrication.
6
NO-RUST WEATHER LAST™ WALL SLEEVE AND FRONT PA NEL
The indoor front panel and polymer wall sleeve use nonmetallic compounds that never rust or corrode, do not support combustion, and do not give off toxic fumes. The weather-resistant feature exceeds require­ments of Underwriters’ Laboratories and resists dam­age caused by impact and scratching. The Weather Last feature also insulates and has up to 10 times the acoustic absorption of metal cabinets.
Insulated polymer wall sleeves combine all of the above features with factory-installed insulation. The insulation helps to reduce heat loss, save energy, pro­vide better sound absorption, and reduce the risk of sleeve sweating.
Carrier’s metal wall sleeves are available in a variety of sizes for most standard and deep wall applications. All metal wall sleeves come with factory-installed insulation, designed to minimize heat loss and reduce outdoor noise transmissions into the room.
Standard Wall Sleeve (Polymer)
42 in.
16 in.
14/18/24/26/28 in.
REMOVABLE FRONT PANEL
The louvered front panel fits firmly onto the chassis and features easy removal for service. It provides front air intake to enhance performance and quiet operation. It also allows the option of flush mounting PTAC unit to the floor. If desired, the front panel can be
secured to the unit with field-supplied screws.
2 locking screws (if installed) are located behind the removable filter handles.
The
ANTI-THEFT KNOBS
The anti-theft knobs are captured underneath the front panel of the unit to prevent the knobs from being removed or stolen.
Standard and Deep Wall Sleeve (Metal)
REMOVABLE FILTER
LOCATION OF REMOVED FILTER
LOCKING SCREW (NOTE: 2nd LOCKING SCREW IS LOCATED BEHIND 2nd FILTER)
Removable Front Panel
LO
HEAT
MODE
OFF
LO
HI
HI
COOL
FAN
TEMPERATURE
WARMER
COOLER
Anti-Theft Knobs
7
PRODUCT FEATURES AND BENEFITS (cont)
TWO-PIECE LIFETIME INDOOR FILTER
New two-piece removable filters easily slide in and out from the front of the PTAC unit and are inter­changeable. The front panel does not need to be removed to access or change the filters. The filters are washable and permanent.
Two-Piece Indoor Filter
WASHABLE VENT AIR FILTER
The unique vent system is activated by a two-position control. Fresh outside air is redirected by the vent door to an inside low-pressure area. A molded plastic filter prevents dirt and debris from entering the room side of the unit. The vent mechanism is made from noncorro­sive material ensuring reliable operation. A magnet on the door and high-pressure airflow create a tight, draft­free seal when the vent door is closed.
Theventwillprovide50cfmoffreshair.
NOTE: If more fresh air cfm is required, a Power-Vent Kit is available (see accessories).
BI-DIRECTIONAL DISCHARGE GRILLE
The discharge grille is constructed of durable polycar­bonate and is reversible. Air flows upward at a 40 degree angle to the floor but can easily be adjusted to an 80 degree angle to the floor.
40 DEGREE AIR FLOW
Outdoor Vent Filter Location
80 DEGREE AIR FLOW
Reversible Polycarbonate Discharge Grille
8
POWER CORD FOR 265-V UNITS
A power cord is included for 265-v units. The power cord is 18 in. long (cord extends 15 in. from bottom of front panel) and per UL and National Electrical codes must plug into an electrical subbase.
POWER CORD PROTECTION FOR 230/208-V UNITS
The power cord for the 230/208-v unit provides power cord protection by automatically disconnecting power during an unsafe condition. Power can be restored by pressing the RESET button.
0
1
9
8
7
6
5
4
3
2
1
265-V Unit with Power Cord
0
2
9
1
8
1
7
1
6
1
5
1
4
1
3
1
2
1
1
1
BI-MOLDED CONDENSER SHROUD
The bi-molded condenser shroud provides easy access for service and maintenance of the condenser coil and related components.
SNOW BAFFLE
The snow baffle is provided to keep snow from blow­ing into the intake and landing on the internal compo­nents of the PTAC unit. Melted snow can form ice on moving parts and cause damage to the unit.
30 Amp In-line 15/20 Amp Power
Power Cord Cord Plug Head
BI-MOLDED CONDENSER SHROUD
Bi-Molded Condenser Shroud
SNOW BAFFLE
Snow Baffle
9
PRODUCT FEATURES AND BENEFITS (cont)
EASY ACCESS TO CHASSIS
Access to the chassis simply requires removing four screwsandthenslidingthechassisoutofthesleeve for service.
T
E
1
S
. P
R
T
E S
2
S
IN
. P
R
L
E
U
S
G
G
E
T I N
R
B T
E
U
O
C
T
E
P
T
3
P
O
O
.
T
P
W
N
A
R
.
E C
E
R
L
S
E
S
.
S
T
H
E
O
S T
U
4
L
B
.
D
U
P
R
T L I
T
E
G
O
S
H
N
S
T
F
.
U
R
O
N
E
R
S
I T
D
E
U
O
T
S
N
E
B
.
O
U
T
T
T
U
O
S
N
E
A
I S
G A
T
I
E
N
S T
A B
O
V
E
F A
I L S
CHASSIS ATTACHMENT SCREWS (SAME LOCATION ON OPPOSITE SIDE)
PLUG TEST/ RESET BUTTONS
Easy Service Access
HIDDEN CONTROLS
The factory-wired control box houses all control com­ponents and is quickly accessible without removing the chassis from the wall sleeve. By simply removing two screws on control box, the hinged door lowers, providing quick access to all the electrical compo­nents. The wiring diagram is located on the front of the control box door.
Temperature Limiter and Control Knob
The limiter reduces operating costs by allowing the owner to control the range of cooling and heating tem­peratures available to the occupant. It is located under the front panel on control box, out of the occupant’s sight. Each setting on the limiter is equivalent to 5° F and the range of temperature settings available to the owner is from 60 to 90 F. The limiter is not pre-set at the factory (providing full range for the occupant).
Fan Cycle Switch
The fan cycle switch allows the fan to operate in 2modes:
• Continuous — This setting allows the fan to run continuously, circulating air even when the temper­ature setting has been satisfied. This setting, which helps to keep the room temperature closer to the thermostat setting, is used for maximum comfort.
• Cycle — This setting allows the fan to cycle on and off with the compressor during heating or cooling. The fan stops when the temperature setting is reached. The longer unit off-time makes this option more energy-efficient with only slightly wider vari­ations in room temperature.
NOTE: On wall thermostat models, the fan cycle/ continuous feature is typically located at the wall thermostat.
Outdoor Air Vent Control
Control of the outdoor-air vent is handled by a vent handle located under the front panel on the left side of the unit. This handle rotates to manually open and close the outdoor vent.
Theventwillprovide50cfmoffreshair.
NOTE: If more fresh air cfm is required, a Power-Vent Kit is available (see accessories).
10
ENHANCED COPPER TUBING
Enhanced copper tubing is more efficient and durable and can be repaired in the field, if required.
Because copper is a very stable metal, it is durable and resists corrosion. Enhanced copper tubing increases:
• heat transfer capability
• the efficiency of the cooling and heating processes
• thermal conductivity (by creating additional tube surface and turbulent refrigerant gas flow)
Every Carrier PTAC coil undergoes thorough leak test­ing and pressure testing up to 350 lb per square inch.
SEAMLESS BASEPAN
Seamless drawn basepan walls add protection against water accumulation resulting from storm-driven rain with heavy wind.
Carrier’s deep basepan holds up to 1 water without spilling. Closed cell foam insulators are located between the basepan and coils, keeping coils from direct contact with the basepan and providing additional protection against corrosion.
1
/2gallons of
Enhanced Copper Tubing
CONDENSATE DRAIN VALVE
The temperature-activated drain valve opens when the outdoor temperature drops below 45 F to prevent water from freezing in the basepan.
CONDENSATE REMOVAL SYSTEM
Carrier’s 52P and 52C Series units have an improved condensate (water) disposal system. In addition to slinger ring technology, Carrier has developed and pat­ented a Condensate Suction Port. The suction port, alongwiththeslingerring,drawsinwaterwhichis sprayed up onto the outdoor coil. The water then evap­orates, thus providing better disposal of excess con­densate, improving unit efficiency.
NOTE: If it is necessary to remove 100% of the con­densate, the Carrier Drain Kit (Part No.: DRAIN-KIT­4PK) is recommended.
SLINGER RING
Condensate Drain Valve Prevents
Water from Freezing in Basepan
CONDENSATE SUCTION PORT
CONDENSER SECTION
Condensate Disposal System
11
PRODUCT FEATURES AND BENEFITS (cont)
HEAT PUMPS PAY THEIR OWN WAY
Heat pump models are available at a nominal addi­tional cost. In many locales, the payback is realized in just a few months. Cost and payback details are pro­vided on the next page.
Special Features
Two-Stage Indoor Thermostat:
The indoor thermostat senses the indoor temperature and automatically turns on the electric heat to warm the room quickly. After the desired temperature condi­tions have been satisfied, the thermostat automatically switches to heat pump mode. If compressor failure occurs, the thermostat will provide backup electric heat automatically.
Outdoor Thermostat:
During the heating cycle, the outdoor thermostat senses outdoor coil temperature. It switches the unit to electric heat mode when the outdoor coil temperature is 20 F or below (approximately 35 F outdoor-air tem­perature). The thermostat switches the unit back to heat pump mode when the outdoor coil temperature rises above 40 F, which is enough to provide heat to meet demand. The entire operation is completely automatic.
How The Heat Pump Works
In Hot Weather:
Carrier’s PTAC units provide indoor comfort in the same manner as conventional air conditioners, remov­ing heat and humidity from indoor air. The heat and humidity is released to the outdoors. Carrier’s high­efficiency design saves energy and reduces cooling costs.
Reversing Valve:
The reversing valve provides quiet refrigerant flow after the unit shuts off. The valve controls the direction of refrigerant flow for both heating and cooling func­tions and remains energized as long as the controls are in the heat position. When the cooling controls are activated, the valve automatically reverses to the cool­ing position.
Manual Compressor Override Switch:
This switch completely locks out the compressor. Note that the compressor and heater do not operate at the same time, thus conserving energy.
In Cool Weather:
When the outdoor coil temperature is above 20 F (approximately 35 F outdoor-air temperature), the heat pump draws heat from outdoor air and uses it to heat indoor air. Since heat is transferred and not pro­duced, Carrier’s heat pump uses less electricity and reduces energy costs significantly.
In Sub-Freezing Weather:
When the outdoor coil temperature falls below 20 F (approximately 35 F outdoor-air temperature), the unit automatically switches on a built-in electric heater. The compressor stops and a blower circulates warm air produced by the heater. When the outdoor coil temperature rises above 40 F, heat pump operation resumes automatically.
12
HEAT PUMP ENERGY SAVINGS
Heat pumps save more on operat­ing costs during the heating cycle than heat/cool models. The table below shows that the higher initial cost of purchasing a heat pump is quickly made up in lower operating costs.
Usethemaptoidentifytheclimate zone’s designated number. Reading down the left-hand column of the table, select the cost/kWh rate in this zone that most closely approxi­mates your local rate. The approxi­mated savings and payback period is found at the intersection of your zone/rate line and the desired Btuh Cooling Capacity column. Exact savings are determined by lifestyle, local electrical rates, and climatic conditions.
ZONE
VI
V
ZONE V
ZONE IV
ZONE III
II
ZONE II
ZONE I
CARRIER HEAT PUMP INITIAL COST VERSUS SAVINGS OVER HEAT/COOL MODELS
7000 BTUH
COOLING
CAPACITY
Annual
Savings*
I
II
III
IV
V
VI
LEGEND
ELECTRIC
COST/kWH
$.06 $ 34.26 21 $ 43.08 21 $ 58.20 19 $ 68.34 19 $.08 $ 45.68 16 $ 57.44 16 $ 77.60 14 $ 91.12 14 $.10 $ 57.10 13 $ 71.80 13 $ 97.00 11 $113.90 12
$.06 $ 57.12 13 $ 71.76 13 $ 96.96 11 $113.64 12 $.08 $ 76.16 9 $ 95.68 9 $129.28 8 $151.52 9 $.10 $ 95.20 8 $119.60 8 $161.60 7 $189.40 7
$.06 $ 58.02 12 $ 72.84 12 $ 98.40 11 $115.38 11 $.08 $ 77.36 9 $ 97.12 9 $131.20 8 $153.84 9 $.10 $ 96.70 7 $121.40 7 $164.00 7 $192.30 7
$.06 $ 82.02 9 $103.02 9 $139.14 8 $163.14 8 $.08 $109.36 7 $137.36 7 $185.52 6 $217.52 6 $.10 $136.70 5 $171.70 5 $231.90 5 $271.90 5 $.12 $164.04 4 $206.04 4 $278.28 4 $326.28 4 $.14 $191.38 4 $240.38 4 $324.66 3 $380.66 3 $.16 $218.72 3 $274.72 3 $371.04 3 $435.04 3
$.06 $ 57.36 13 $ 71.94 13 $ 97.26 11 $113.94 12 $.08 $ 76.48 9 $ 95.92 9 $129.68 8 $151.92 9 $.10 $ 95.60 8 $119.90 8 $162.10 7 $189.90 7 $.12 $114.72 6 $143.88 6 $194.52 6 $227.88 6 $.14 $133.84 5 $167.86 5 $272.33 4 $265.86 5
$.06 $ 93.72 8 $117.66 8 $159.00 7 $186.48 7 $.08 $124.96 6 $156.88 6 $212.00 5 $248.64 5 $.10 $156.20 5 $196.10 5 $265.00 4 $310.80 4 $.12 $187.44 4 $235.32 4 $318.00 3 $372.96 4
ZONE
kWH — Kilowatt Hour
*Computer projections based on full cooling load at 95° F. Sav-
ings projected for 230 v ratings.
1
Heating load is 5,000 Btuh at winter design point temperature.
2
Heating load is 10,000 Btuh at winter design point temperature.
3
Heating load is 15,000 Btuh at winter design point temperature.
1
PREMIUM
Payback
in Months
$60
9000 BTUH
COOLING
CAPACITY
Annual
Savings*
2
PREMIUM
Payback
in Months
$75
12000 BTUH
COOLING
CAPACITY
Annual
Savings*
2
PREMIUM
Payback
in Months
$90
15000 BTUH
COOLING
CAPACITY
Annual
Savings*
3
PREMIUM
Payback
in Months
$110
For precise energy savings in your geographical location, go to www.lodgingAC.com to use Carrier’s energy calculator.
13

ORDERING DATA (52P AND 52C)

For immediate assistance, call 1-800-827-7435 or contact your local Carrier dealer.
Standard Unit
• Chassis with front panel
• Electro-mechanical controls
• Cord-connected chassis for 230/208-v and 265-v units
Lead-time: Many models are in stock for immediate delivery; call for lead-times.
Y)
EXTERIOR GRILLE (ACCESSORY)
FRONT PANEL (STANDARD)
PRODUCT CATALOG NUMBER
TESTING
1.PR E S
2
S
.P
R
L
E
U
SE
G
T
IN
RE
B
T
U
O
CE
TT
PO
3.PR P
O
T
W
N.
A
E
C
E
R
LE
S
S
.
S
T
HO
E ST
U
4
L
B
.P
D
U
R
T
LIG
T
ES
O
HT
N
S
F
.
U
R
O
N
E
R
S
I T
D
ET
U
O
S
N
E
B
.
O
U T
T
T
U
O
S
N
E
A
I
S
G
A
T E
IN
S T
A B
O V E
F
A I L
S
PLUG TEST/ RESET BUTTONS
CHASSIS (STANDARD)
Standard 52P or 52C Unit
WALL SLEEVE (ACCESSOR
14

FACTORY-INSTALLED OPTIONS (52P AND 52C)

WALL THERMOSTAT CONTROL (RC,RP)
Carrier’s wall thermostat control option includes:
• a standard chassis with front panel
• factory-installed low voltage controls for remote thermostat operation
• indoor coil freeze protection
• user accessible selector switch for high or low fan speed
Wall thermostat and wall thermostat wire must be ordered separately.
See page 50 for a diagram of multiple PTAC units con­trolled by a single thermostat.
NOTE: Be sure to connect reversing valve wiring to the O connection of the thermostat for heat pump applications.
NOTE: Do not use a power stealing digital thermostat (common must be connected for digital thermostats).
CORROSION PROTECTION
FA
N
S
P
E
E
D
L O
H I
C
o
m
fo
r
t
W
A L
L
T
H
E
R M
O
S
T A
T
C
O
M F
O
R
T
(CP,RP)
To protect against the corrosive effects of a seacoast environment, this option includes:
• a standard chassis with front panel
• special protections consisting of: — painted control box and unit partitions
— pre-coated aluminum coils with copper tubing — stainless steel tube sheets (outdoor coil) — totally enclosed fan motor with moisture-
resistant windings
NOTE: All installations within one mile of the sea coast or other corrosive environment must use Corro­sion Protection (CP).
15

FIELD-INSTALLED ACCESSORIES (52P AND 52C)

WALL SLEEVES
Weather Last™ Wall Sleeve
For the best performance and longest life, Carrier recommends genuine Carrier wall sleeves for all installations.
All Carrier wall sleeves are built with a pitch of 1/4 in. per foot; for self-pitching of the unit, the wall sleeve must be installed level (any error should be pitched to the outside). Overflow slots on the outside of the sleeve are in place to divert excess water during severe weather.
Important Sleeve Installation Considerations:
• All Carrier's sleeves are self pitching and must be mounted level in all directions. (Do not use rails to level sleeve.)
• The sleeve should be caulked on all sides, includ­ing both inside and outside the building.
• If more than 4 in. of wall sleeve projects into the room, an accessory subbase must be used for support.
• For all applications with an accessory subbase, wall sleeve must extend 3 room and must be 31/4in. minimum to 51/2in. maximum above floor (including carpeting) to allow for proper fit of subbase.
• For applications where the wall sleeve is mounted flush to the exterior of the building (or recessed in), Carrier recommends a field­supplied drip edge be installed to prevent water infiltration into the building.
• Insulated wall sleeves should be considered for superior sound absorption, to reduce heat loss and to prevent sleeve sweating, a condition that can occur when the outside temperature is cold and the indoor conditions are warm and humid.
1
/4in. minimum into
The sleeve's alpine mist color (a shade of beige) closely matches the front panel and blends in well with any inside or outside decor.
The polymer wall sleeve comes in both insulated (fac­tory installed) or non-insulated, to meet the require­ments of every application.
Insulated Polymer Wall Sleeve
Part No.: SLEEVE-INSUL-1PK Carrier’s accessory insulated polymer wall sleeve, with
factory-installed insulation, provides superior sound absorption, reduces heat loss and prevents sleeve sweating, a condition that can occur when the outside temperature is cold and the indoor conditions are warm and humid.
IMPORTANT: Insulated Polymer Wall sleeve pro­vides superior sound absorption, reduces heat loss and prevents sleeve sweating.
Corrosion-Protected Polymer Sleeve
Non-Insulated Polymer Wall
Polymer Wall Sleeves
Choose a polymer wall sleeve for maximum protec­tion and appearance.
All Carrier’s polymer wall sleeves are made from a molded polymer that is designed for strength and dura­bility. This material has excellent corrosion resistance and a flammability rating of UL94-5V.
The sleeve surface is textured to prevent shine and hide scratches. The rib configuration on the sleeve bot­tom, allows easy chassis removal and aids in drainage. The locating holes in the side and top panels, allow easy fastening of the sleeve to wall openings. Refer to dimension drawings (pages 28 and 29) for typical wall installation and dimensions.
Sleeve
Part No.: WALL-SLEEVE-1PK Part No.: WALL-SLEEVE-9PK Carrier’s accessory non-insulated polymer wall sleeve,
provides a superior appearance and protection for many applications.
For applications where weather conditions could influence sleeve sweating, a condition that can occur when the outside temperature is cold and the indoor conditions are warm and humid, the Insulated Poly­mer Wall sleeve should be considered.
16
Insulated Metal Wall Sleeves
42 IN.
Part No.: SLEEVE-STEEL-1PK Part No.: SLEEVE-EXT18-1PK Part No.: SLEEVE-EXT24-1PK Part No.: SLEEVE-EXT26-1PK Part No.: SLEEVE-EXT28-1PK
Carrier's metal wall sleeves are available in a variety of sizes for most applications and difficult installa­tions. Choose from 14 in., 18 in., 24 in., 26 in., or 28 in. standard depth sizes. All metal wall sleeves come with factory-installed insulation, designed to minimize heat loss, reduce outdoor noise transmis­sions into the room and prevent sleeve sweating. In addition, the metal wall sleeve provides a flammability rating higher than UL94-5V.
Wall Sleeve Molding Kit
Part No.: SLEEVE-MOLDING For a superior look and to hide any construction
imperfections, use Carrier's wall sleeve molding kit to trim the wall sleeve to the wall. The molding kit is a perfect solution and can be used with any Carrier wall sleeve (matches Carrier wall sleeve color).
16 IN.
14/18/24/26/28 IN.
Standard and Extended Metal Wall Sleeve
1 IN.
1/2 IN.
Friedrich (and ZoneAire) Retro­fit Wall Sleeve Adapter
Part No.: FR-SLEEVE-EXT The Friedrich (and ZoneAire) wall sleeve adapter is
constructed of sheet metal and is designed to increase the depth of an existing Friedrich T-series or ZoneAire wall sleeve to accommodate Carrier’s industry stan­dard PTAC units.
Climate Master Wall Sleeve Adapter
Part No.: CM-SLEEVE-EXT The Climate Master wall sleeve adapter is constructed
of sheet metal and is designed to increase the depth of an existing Climate Master 12 accommodate Carrier’s industry standard PTAC units.
1
/2in. wall sleeve to
Wall Sleeve Molding Kit
16 IN.
42 IN.
3IN.
Friedrich Wall Sleeve Adapter Kit
16 IN.
42 IN.
17
1 1/2 IN.
Climate Master Wall Sleeve Adapter Kit