58CTA/C TX
P E R F O R M A N C E ™ 8 0 T W O --- S T A G E 4 --- W AY
MUL TIPOISE INDUCED---COMBUSTION GAS FURNACE
Input Capacities: 45,000 thru 155,000 Btuh
Series 140
Product Data
the home by automatically adjusting high and low heat times to
maximize comfort. The 58CTA/CTX furnaces are approved for use
with natural or propane gas, and the 58CTX is approved for use in
Low NOx Air Quality Management Districts.
STANDARD FEATURES
S ComfortHeatt Technology Intelligent microprocessor
control
S Two--stage heating with single-stage thermostat with
patented Adaptive Control Technology
S Very low operating sound through low--stage operation and
QuieTecht system
S SmartEvapt--Humidity control when using a
Thermidistatt control
S Comfort Fant adjustable constant fan speed from the
Performance
A10249
THE PERFORMANCE 80 GAS FURNACE
The 58CTA/CTX Two-Stage, 4-way Multipoise Gas Furnaces
offer unmatched comfort in their class with ComfortHeatt
technology in an 80% AFUE gas furnace. You get the benefits of a
ComfortHeatt technology furnace: reduced drafts, reduced sound
levels, longer cycles, less temperature swings between cycles, and
less temperature differences between rooms. Its exclusive,
intelligent microprocessor control adapts to the heating needs of
thermostat
S Microprocessor based control center
Enhanced diagnostics with LED and reflective sight glass
Stores fault codes during power outages
Adjustable heating air temperature rise
Adjustable cooling airflow
S 4-way Multipoise furnace, 13 vent applications
S Compact design -- only 33-1/3 in. (847 mm)tall
S Power Heatt Igniter
S Draft Safeguard switch to ensure proper furnace venting
S Insulated blower compartment
S Inner door for tighter sealing
S Certified to leak 2 percent or less of its nominal air
conditioning CFM delivered when pressurized to 1--In.
Water Gauge with all present air inlets, air outlets, and
condensate drain port(s) sealed.
S HYBRID HEATr Dual Fuel System compatible
S All models are Chimney Friendly when used with accessory
vent kit
S Twinning in Upflow, Downflow and Horizontal
S Residential installations eligible for consumer financing
NOTE: The 58CTA/CTX Furnaces are factory shipped for use with natural gas. These furnaces can be field-converted for propane gas with
a factory-authorized and listed accessory conversion kit.
3
CARRIER ACCESSORIES
CONTROLS:
THERMOSTATS
AND ZONING
Available in programmable and
non-programmable models, Carrier
thermostats maintain a constant
temperature level in the home.
For the ultimate in home comfort,
Carrier’s 2, 4, and 8-zone systems
allowtemperaturecontrolof
58CTA/CTX
individual “zones” of the home.
This is accomplished through a
series of electronic dampers and
remote room sensors. The 4-zone
system is shown.
A97432
C04008
MECHANICAL
OR ELECTRONIC
AIR CLEANER
Cleans the air of smoke, dirt, and
many pollens commonly found.
Saves decorating and cleaning
expenses by keeping carpets,
furniture, and drapes cleaner.
Electronic air cleaner is shown.
A01484
MODEL HUMCCLFP
HUMIDIFIER
By adding moisture to winter-dry
air, a Carrier humidifier can often
improvecomfortandkeep
furniture, rugs, and draperies in
better condition. Moisturizing
household air also helps to retain
normal body heat and provides
comfort at lower temperatures.
Accessories
ELECTRONIC AIR CLEANER (EAC)Model EACB
MECHANICAL AIR CLEANERModels EZXCAB, FILCAB
HUMIDIFIERModel HUM
HEAT RECOVERY VENTILATORModel HRV
ENERGY RECOVERY VENTILATORModel ERV
For u s e w i t h 1 --- spe e d A i r C o n d i t i o n e r --- deg. F / C , A u t o C h a n g e over --- TP --- N A C, T C --- N A C
T H E R M OSTA T --NON---PROGRAMMABLE
T H E R M OSTA T --PROGRAMMABLE
ZONING CONTROL
* Model HP and 2S thermostat must be field converted to air conditioner operation.
† Thermidistat Control can be configured for multiple use and staging, it mu st be configured for each specific application.
For u s e w i t h 1 --- spe e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r --- T P --- N H P , T C --- N H P *
For u s e w i t h 2 --- spe e d A i r C o n d i t i o n e r --- deg. F / C , A u t o C h a n g e over --- TP --- N R H*
For use with multi---use / stage configurations --- deg. F/C, Auto Changeover/Temperature and Humidity control
--- T P --- P R H†
For u s e w i t h 1 --- spe e d A i r C o n d i t i o n e r --- deg. F / C , A u t o C h a n g e over , 7 --- D a y P r o g r ammabl e --- TP --- PA C
For u s e w i t h 1 --- spe e d H e a t P u m p --- d e g . F / C , A u t o C h a n g e o v e r, 7 --- D a y P rogr a m m a b l e --- T P --- P H P *
For u s e w i t h 2 --- spe e d A i r c o n d i t i o n e r --- deg. F / C , A u t o C h a n g eover , 7 --- D a y P r o g rammabl e --- T P --- P R H*
For u s e w i t h 1 --- spe e d A i r C o n d i t i o n e r --- deg. F / C , 5 --- 2 D a y P r o g rammabl e --- T P --- PA C
For u s e w i t h m u l t i --- s t a g e a p pli c a t i o n s --- d e g . F / C , A u t o C h a n g e over , 7 --- D a y P r o g r ammabl e --- T C --- P R H†
For m u l t i --- u s e / s t a g e c onfig u r a t i o n s --- d e g. F / C , A u t o C h a n geove r, 7 --- D a y P r o g rammab l e / Te m p e r ature a n d
H u m i dit y C o n t r o l --- T P --- P R H †
Comfort™ Series 3-Zone Kit --- ZONECC3ZAC01, ZONECC3ZHP01
2 Performance™ Series ComfortZone™ II Zoning/Temperature and Humidity Control --- ZONECC2KIT01--- B
4 Performance™ Series ComfortZone™ II Zoning/Temperature and Humidity Control --- ZONECC4KIT01--- B
8 Performance™ Series ComfortZone™ II Zoning/Temperature and Humidity Control --- ZONECC8KIT01--- B
4
CARRIER ACCESSORIES
58CTA/CTX DESCRIPTIONPAR T NO.045-08045-12070-08070-12070-16090-14090-16090-20110-12110-16110-22135-16135-22155-
FILCABCC0016XXXXXXX
Media Filter Cabinet
Cartridge Media Fi lte r
EZ Flex Media Filter with En d Caps
Replacement EZ Flex Filter Media
External Bottom Return Filter Rack
External Side Return Filter RackKGA FR0801SREXXXXXXXXXXXXXX
Propane-to-Natural Convers ion KitKGAPN3901ALLXXXXXXXXXXXXXX
Label KitKGALB0101KITXXXXXXXXXXXXXX
Gas Orifice Kit (Qty 50)
* Fac t o ry- aut ho rized and field installed. Fuel conversi o n kits are CSA (formerly AGA/CGA) recognized.
† Suitable for Side Return Filter Rack
X = Accessory
S=Standard
FILCABCC0020XXXXX
FILCABCC0024XX
FILCCCAR0016XXXXXXX
FILCCCAR0020XXXXX
FILCCCAR0024XX
EXPXXUNV0016XXXXXXX
EXPXXUNV0020XXXXX
EXPXXUNV0024XX
EXPXXFIL0016XXXXXXX
EXPXXFIL0020XXXXX
EXPXXFIL0024XX
KGAFR0401B14XXXX
KGAFR0501B17XXX
KGAFR0601B21XXXXX
KGAFR0701B24XX
KGAWF1301UFR†XXXXXXX
KGAWF1401UFRXXXXX
KGAWF1501UFRXX
KGAWF1306UFR†XXXXXXX
KGAWF1406UFRXXXXX
KGAWF1506UFRXX
KGACA02014FCXXXXXXXXXXX
KGACA02015FCXXX
KGAHA0150N42
KGAHA0250N43
(factory supplied)
KGAHA0350N44
KGAHA0450N45
KGAHA0550N46
KGAHA1550N47
KGAHA1650N48
KGAHA0650P54
KGAHA0750P55
KGAHA0850P56
KGAHA5750125
KGAHA5750130
See Installatio n Instructi o ns for model, altitude, and heat value usages
Maximum Inlet Pressure (In. W.C.)13.6 (Natural Gas)
IGNITION DEVICEHot S urface
* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce r a tings 4 percent for each 1000 ft. (305M)
above sea level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 ---2009 Table F.4 or furn a ce Installation Instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return ---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each
return-air supply.
ICS — Isolated Combustion System
All 58CTA; 58CTX
Upflow
All 58CTX Downflow/
Horizontal
All 58CTA; 58CTX
Upflow
All 58CTX Downflow/
Horizontal
Heating0.100.100.120.120.120.150.150.15
Cooling0.500.500.500.500.500.500.500.50
Heating H ig h/Low820/7251030/860790/685885/6951570/1045 1375/1195 1265/1030 1580/1325
Maximum Inlet Pressure (In. W.C.)13.6 (Natural Gas)
IGNITION DEVICEHot S urface
* Gas input ratings are certified for elevations to 2000 ft. (610 M). For elevations above 2000 ft. (610 M), reduce r a tings 4 percent for each 1000 ft. (305M)
above sea level. Refer to National Fuel Gas Code NFPA 54/ ANSI Z223.1---2009 Table F.4 or furnace Installation Instructions.
† Capacity in accordance with U.S. Government DOE test procedures.
‡ Airflow shown is for bottom only return ---air supply. For air delivery above 1800 CFM, see Air Delivery Table for other options. A filter is required for each
return-air supply.
ICS — Isolated Combustion System
All 58CTA; 58CTX
Upflow
All 58CTX Downflow/
Horizontal
All 58CTA; 58CTX
Upflow
All 58CTX Downflow/
Horizontal
Heating0.200.200.200.200.200.20
Cooling0.500.500.800.500.500.50
Heating H ig h/Low1335/11801290/10451555/12951525/13201865/16401790/1565
1. For common vent, vent connector sizing and vent material: United States, latest edition of the National Fuel Gas
Code (NFGC), ANSI Z223.1/NFPA 54.
2. Immediately increase to 5-in. (127 mm) vent connector outside furnace casing when 5-in. (127 mm) vent connector
required, refer to Note 1.
3. Side outlet vent for upflow and downflow installations must use Type B vent immediately after exiting the furnace,
except when Downflow Vent Guard is used in downflow position.
4. Type B vent where required, refer to Note 1.
5. 4---in. (102 mm) single wall vent must be used inside furnace casing and the Downflow Vent Guard Kit.
6. Accessory Downflow Vent Guard Kit, required in downflow installations with bottom vent configuration.
7. Chimney Adapter Kit required for exterior masonry chimney applications. Refer to Chimney Adapter Kits for sizing
and complete application details.
8. Secure vent connector to furnace elbow with (2) corrosion-resistant sheet metal screws, space approximately 180°
apart.
9. Secure all other single wall vent connector joints with (3) corrosion-resistant screws spaced approximately 120°
apart. Secure Type B vent connectors per vent connector manufacturer’s recommendations.
SEE NOTES: 1,2,3,4,5,7,8,9
DOWNFLOW
SEE NOTES: 1,2,4,5,6,7,8,9
DOWNFLOW
A02062
8
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
A02068
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL RIGHT
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL RIGHT
A02069
A02070
58CTA/CTX
SEE NOTES: 1,2,4,7,8,9
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02066
A02064
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
SEE NOTES: 1,2,4,5,7,8,9
HORIZONTAL LEFT
A02065
A02067
9
AIR DELIVERY—CFM (With Filter)*
RETURN-AIR
UNIT SIZE
045-08
045-12
070-08
070-12
070-16
58CTA/CTX
090-14
090-16
090-20
* A filter is required for each return-- -air supply. Airflow perf ormance includes 3/4--- in. (19 mm) washable filter media su ch as contained in factory --- a uth o r i ze d
accessory filter rack. To determine airflow performance without this filter, assume an additional .1 available external static pressure.
— Indicates unstable operating conditions.
SUPPLY
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
Only
Both Sides
or 1
Side & Bottom
1SideOnly
SPEED
High
Med-High
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
0.10.20.30.40.50.60.70.80.91.0
1120
930
820
725
1465
1295
1150
1030
860
1140
915
795
690
1440
1180
1015
885
695
1840
1610
1460
1260
1065
1650
1515
1385
1205
2060
1710
1470
1260
1030
2380
2185
1905
1595
1340
2485
2175
1845
1540
1280
2420
2160
1850
1530
1290
1075
890
785
690
1400
1260
1120
1008
835
1105
885
770
665
1400
1165
1020
885
700
1790
1575
1430
1240
1040
1600
1485
1360
1180
2000
1695
1475
1265
1025
2295
2115
1865
1565
1310
2415
2130
1815
1515
1250
2345
2110
1815
1490
1250
1020
1325
1210
1085
1055
1355
1150
1010
1730
1535
1400
1215
1015
1535
1440
1320
1160
1930
1665
1450
1245
1020
2205
2045
1815
1530
1280
2330
2070
1770
1475
1220
2265
2045
1765
1455
1220
EXTERNAL STATIC PRESSURE (In. W.C.)
850
750
655
980
810
855
740
630
880
700
960
805
700
605
1250
1155
1040
945
780
1010
825
700
590
1300
1125
990
865
690
1670
1485
1360
1180
985
1465
1380
1260
1120
1835
1585
1390
1225
990
2105
1960
1740
1485
1225
2230
2000
1720
1435
1190
2165
1960
1710
1420
1190
895
750
650
555
1175
1090
985
895
745
955
785
655
550
1240
1085
965
845
670
1605
1435
1315
1145
955
1385
1300
1195
1065
1755
1480
1335
1165
940
2005
1875
1670
1430
1170
2135
1930
1655
1385
1155
2070
1885
1635
1375
1155
815
680
585
495
1085
1015
920
835
700
885
725
600
475
1170
1030
925
815
640
1530
1370
1260
1100
915
1285
1220
1120
1005
1620
1390
1230
1090
890
1900
1770
1590
1355
1120
2030
1840
1580
1335
1105
1960
1790
1560
1320
1110
720
600
505
405
980
930
835
765
635
815
655
510
415
1090
970
875
770
600
1450
1305
1205
1040
875
1175
1115
1025
925
1490
1245
1120
995
810
1775
1655
1490
1275
1040
1920
1740
1500
1270
1035
1850
1695
1480
1250
1040
605
500
400
305
860
830
740
685
555
715
530
420
340
1000
890
800
700
540
1370
1230
1130
985
825
1055
990
915
810
1315
1110
1005
880
720
1650
1535
1390
1160
955
1790
1620
1395
1175
945
17720
1570
1380
1160
950
455
345
235
—
725
700
620
—
—
545
420
325
245
890
785
700
605
460
1275
1145
1055
915
765
895
830
710
630
1115
955
855
750
615
1510
1400
1245
1055
850
1645
1495
1270
1045
845
1570
1445
1250
1055
835
340
195
—
—
—
—
—
—
—
390
280
—
—
745
645
560
475
345
1170
1055
965
835
695
645
600
565
510
910
775
690
600
500
1335
1240
1110
920
750
1485
1345
1090
915
745
1420
1305
1110
905
740
10
AIR DELIVERY—CFM (With Filter)* continued
RETURN-AIR
UNIT SIZE
110-12
110-16
110-22
135-16
135-22
155-20
* A filter is required for each return-- -air supply. Airflow perf ormance includes 3/4--- in. (19 mm) washable filter media su ch as contained in factory --- a uth o r i ze d
accessory filter rack. To determine airflow performance without this filter, assume an additional .1 available external static pressure.
— Indicates unstable operating conditions.
SUPPLY
Bottom
or
Side(s)
Bottom
or
Side(s)
Bottom
Only
Both Sides
or 1
Side & Bottom
1SideOnly
Bottom
or
Side(s)
Bottom
Only
Both Sides
or 1
Side & Bottom
1SideOnly
Bottom
Only
Both Sides
or 1
Side & Bottom
1SideOnly
SPEED
High
Med-High
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High
Medium
Med-Low
Low
High
Med-High—2205
High
Med-High
Medium
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High
Med-Low
Low
High
Med-High—2155
High
Med-High—2140
0.10.20.30.40.50.60.70.80.91.0
1625
1510
1360
1195
2055
1750
1545
1300
1050
2530
2225
1895
1565
1320
2485
2155
1830
1520
1275
2090
1790
1545
1325
2485
2195
1880
1640
—
2180
1880
1640
2320
2125
1845
1640
2465
2115
1800
1570
1575
1470
1335
1180
1990
1725
1525
1290
1045
2460
2190
1885
1555
1295
—
2175
2430
2135
1830
1505
1260
2010
1755
1525
1320
2400
2150
1850
1635
—
2145
1850
1635
2250
2065
1825
1620
2430
2105
1790
1565
—
2135
—
2095
1515
1415
1295
1155
1910
1670
1490
1275
1015
2380
2135
1865
1535
1265
2415
2120
2360
2100
1810
1490
1240
1930
1705
1500
1295
2310
2090
1820
1615
2385
2060
1820
1615
2155
1995
1765
1580
2375
2075
1770
1551
2375
2095
2260
2040
EXTERNAL STATIC PRESSURE (In. W.C.)
1445
1355
1250
1115
1815
1605
1445
1235
975
2285
2075
1820
1505
1235
2330
2065
2270
2040
1780
1470
1210
1835
1640
1450
1265
2215
2000
1780
1585
2305
2010
1780
1585
2055
1910
1710
1540
2305
2030
1735
1525
2285
2040
2180
1975
1355
1285
1180
1065
1695
1515
1355
1165
935
2200
1995
1770
1465
1205
2235
1975
2175
1970
1730
1430
1180
1710
1550
1380
1210
2110
1920
1715
1530
2195
1945
1715
1530
1970
1815
1650
1485
2230
1980
1695
1495
2200
1975
2085
1890
1260
1185
1100
980
1575
1400
1260
1085
880
2085
1910
1700
1410
1160
2125
1900
2070
1885
1665
1385
1135
1590
1465
1315
1150
2000
1825
1635
1465
2085
1865
1635
1465
1855
1710
1570
1410
2110
1910
1640
1445
2105
1895
1975
1810
1165
1070
985
860
1425
1255
1135
1005
815
1970
1805
1610
1350
1105
1995
1790
1950
1790
1595
1330
1090
1470
1360
1215
995
1880
1720
1540
1370
1960
1765
1540
1370
1725
1610
1475
1330
2000
1830
1570
1370
1995
1790
1865
1705
990
890
810
740
1230
1120
1020
895
715
1835
1695
1520
1265
1035
1860
1685
1825
1680
1505
1250
1025
1335
1210
1005
865
1725
1565
1415
1255
1825
1660
1415
1255
1600
1490
1370
1220
1865
1725
1465
1270
1870
1685
1740
1595
785
725
670
605
1090
975
880
750
610
1695
1565
1410
1175
950
1735
1580
1685
1560
1395
1165
930
1025
945
855
745
1535
1405
1290
1150
1670
1515
1290
1150
1450
1340
1240
1080
1725
1590
1345
1175
1730
1550
1605
1480
595
530
475
410
910
785
750
620
515
1545
1430
1290
1050
870
1605
1460
1535
1420
1275
1055
840
835
785
670
540
1355
1255
1160
1040
1465
1325
1160
1040
1280
1175
1100
960
1545
1425
1225
1070
1570
1400
1455
1325
58CTA/CTX
11
DIMENSIONS
A
B
[736.9]
29
Ø7/8
[22.2]
ACCESSORY
5 15/16
[150.7]
28.39
[721.2]
Ø7/8
[22.2]
ACCESSORY
14 7/8
[337.3]
(BOTH SIDES)
Ø7/8
[22.2]
ACCESSORY
Ø7/8
[22.2]
ACCESSORY
Ø1 3/4
[44.5]
GAS ENTRY
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
22 1/16
[560]
SIDE INLET
(BOTH SIDES)
11 7/16
[290.7]
9 11/16
[245.4]
[197.8]
7 13/16
Ø7/8
[22.2]
J.BOX PROVISION
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
1 15/16
[49.2]
1
[25.4]
1 1/4
[31.8]
29 9/16
[750.7]
1 15/16
[49.2]
5 5/8
[143.3]
5 7/16
[138.5]
6 13/16
[172.3]
Ø1/2
[12.7]
THERMOSTAT WIRE ENTRY
19
[481.7]
OUTLET
D
21.6
[549.5]
BOTTOM INLET
C
33 1/4
[843.9]
9 9/16
[243.3]
3/4
[19.1]
5 7/8
[148.5]
3 7/16
[86.8]
9 7/8
[250.7]
27 3/4
[704.7]
2 5/16
[59]
FRONT OF CASING
TOP OF CASING
4 13/16
[122.2]
27 3/4
[704.7]
5 7/8
[148.5]
8 5/8
[219]
5 1/2
[140.3]
8 7/16
[213.5]
FRONT OF CASING
TOP OF CASING
6.1
[155.7]
2 1/16
[51.6]
5.1
[130.5]
1.7
[43.5]
Ø7/8
[22.2]
ACCESSORY (2)
AIR FLOW
AIR FLOW
BOTTOM RETURN
WIDTH
AIR FLOW
KNOCK OUTS FOR
VENTING(5
PLACES)
5.1
[130.5]
2 1/16
[51.6]
1.7
[43.5]
Ø7/8
[22.2]
ACCESSORY (2)
FRONT OF CASING
8 5/8
[219]
6 13/16
FRONT OF CASING
1 15/16
33 1/4
[843.9]
27 3/4
[704.7]
9 7/8
[250.7]
8 7/16
[213.5]
5 15/16
[150.7]
5 1/2
[140.3]
AIR FLOW
ACCESSORY
THERMOSTAT WIRE ENTRY
Ø7/8
[22.2]
Ø1/2
[12.7]
[49.2]
3 7/16
[86.8]
5 7/8
[148.5]
2 5/16
[59]
TOP OF CASING
Ø7/8
[22.2]
JUNCTION BOX
LOCATION
Ø1 3/4
[44.5]
GAS ENTRY
AIR FLOW
A
TOP OF CASING
29 9/16
[750.7]
27 3/4
[704.7]
58CTA/CTX
Ø7/8
[22.2]
ACCESSORY
21.6
[549.5]
BOTTOM INLET
28.39
[721.2]
29
[736.9]
NOTES:
1. Two additional 7/8---in. (22 mm) diameter holes are located in the top plate.
2. Minimum return ---air openings at furnace, based on metal duct. If flex duct is used, see flex duct manufacturer’s recommendations for equivalent diameters.
[155.7]
6.1
BOTTOM RETURN
WIDTH
[19.1]
3/4
a. For 800 CFM--- 16 --- in. (406 mm) round or 14 1/2 x 12---in. (368 x 305 mm) rectangle.
b. For 1200 CFM---20 ---in. (508 mm) round or 14 1/2 x 19 1/2---in. (368 x 495 mm) rectangle.
c. For 1600 CFM---22 ---in. (559 mm) round or 14 1/2 x 22 1/16---in. (368 x 560mm) rectangle.
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature f o r specific use of single side inlets. The use of both sideinlets,
a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
*135 and 155 size furnaces require a 5 or 6 ---in. (127 or 152 mm) vent. Use a vent adapter between furnace and vent stack. See Installation Instructions for
complete installation requirements.
B
OUTLET
WIDTH
IN (mm)
C
TOP AND
BOTTOM FLUE
COLLAR
IN (mm)
12
D
BOTTOM
INLET WIDTH
IN (mm)
VENT
CONNECTION
SIZE
IN (mm)
SHIP WT
LB (KG)
ACCESSORY
MEDIA
CABINET SIZE
IN (mm)
58CTA/CTX
A10269
I
G
S
E
N
D
Always Ask For
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
13
C
E
R
D
E
I
T
F
I
TYPICAL WIRING SCHEMATIC
58CTA/CTX
A95236
ELECTRICAL DATA
OPERATING VOLTAGE RANGE
58CTA/CTX
UNIT SIZE
045-08115-60-11271045.349 (14.9)1514
045-12115-60-11271047.138 (11.5)1514
070-08115-60-11271045.251 (15.5)1514
070-12115-60-11271047.337 (11.2)1514
070-16115-60-112710410.127 (8.2)1514
090-14115-60-11271048.234 (10.3)1514
090-16115-60-11271049.928 (8.5)1514
090-20115-60-112710412.934 (10.3)2012
110-12115-60-11271048.234 (10.3)1514
110-16115-60-112710410.128 (8.5)1514
110-22115-60-112710413.732 (9.7)2012
135-16115-60-112710410.227 (8.2)1514
135-22115-60-112710414.530 (9.1)2012
155-20115-60-112710415.029 (8.8)2012
* Permissible limits of the voltage range at which unit operates satisfactorily.
† Time--- delay type is recommended.
‡ Length shown is as measured 1 way along wire path between unit and service panel for maximum 2 percent voltage drop.
VOLTS HERTZ
PHASE
Maximum*Minimum*
MAXIMUM
UNIT AMPS
MAXIMUM
WIRE
LENGTH --
FT (M)‡
MAXIMUM
FUSE OR CKT
BKR AMPS†
MINIMUM
WIRE GAGE
14
TYPICAL INSTALLATION
CONDENSING
UNIT
HUMIDIFIER
AIRFLOW
ELECTRONIC
AIR CLEANER
GAS-FIRED
WATER HEATER
58CTA/CTX
A10211
15
GUIDE SPECIFICATIONS
Gas Furnace
58CTA/CTX
General
SYSTEM DESCRIPTION
Furnish a _________________ fixed capacity gas-fired
furnace for use with natural gas or propane (factory
authorized conversion kit required for propane); furnish
cold air return plenum.
QUALITY
ASSURANCE
Unit will be designed, tested and constructed to the
current ANSI Z 21.47/CSA 2.3 design standard for
gas--fired central furnaces.
Unit will be 3rd party certified by CSA to the current
ANSI Z 21.47/CSA 2.3 design standard for gas--fired
central furnaces.
Unit will carry the CSA Blue StarR label.
Unit efficiency testing will be performed per the current
DOE test procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and
listed in the latest AHRI Consumer’s Directory of
58CTA/CTX
Certified Efficiency Ratings.
Unit shall carry the current Federal Trade Commission
Energy Guide efficiency label.
DELIVERY, STORAGE AND
HANDLING
Unit shall be shipped as single package only and is
storedandhandledperunitmanufacturer’s
recommendations.
WARRANTY (for inclusion by specifying
engineer)
U.S. only. Warranty certificate available upon request.
Products
EQUIPMENT
Components shall include: slow-opening two stage gas
valve to reduce ignition noise, regulate gas flow, with
electric switch gas shut-off; flame proving sensor, hot
surface igniter, pressure switch assembly, flame rollout
switch, blower and inducer assembly, 40va transformer;
low-voltage (heating) (heating/cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type,
statically and dynamically balanced. Blower motor of PSC
type shall be permanently lubricated with sealed bearings,
of _______hp, and shall be multiple-speed direct drive.
Blower motor shall be soft mounted to the blower scroll to
reduce vibration transmission.
Filters
Furnace may have reusable--type filters. Filter shall be
_______ (x) _______in. (mm). An accessory high
efficiency Media Filter is available as an option.
_______________ Media Filter.
Casing
Casing shall be of .030 in. (.76 mm) thickness
minimum, pre-painted galvanized steel.
Two Speed Inducer Motor
Two Speed Inducer motor shall be soft mounted to
reduce vibration transmission.
Draft Safeguard Switch
Draft Safeguard Switch (blocked vent safeguard) shall
be factory installed to reduce the possibility of vent gas
infiltration due to a blocked or restricted vent pipe.
Heat Exchangers
Heat exchangers shall be a 4-Pass 20 gage aluminized
steel of fold--and--crimp sectional design when applied
operating under negative pressure.
Controls
Controlshallincludeamicro--processorbased
integrated electronic control board with at least 11 service
troubleshooting codes displayed via diagnostic flashing
enhanced LED light on the control, a self--test feature that
checks all major functions of the furnace within one
minute, andareplaceableautomotive-typecircuit
protection fuse. Multiple operational settings available
including, separate blower speeds for low heat, high heat,
low cooling, high cooling and continuous fan. Continuous
fan speed may be adjusted from the thermostat. Cooling
airflow will be selectable between 350 or 400 CFM per ton
of air conditioning. Features will also include temporary
reduced airflow in the cooling mode for improved
dehumidification when a control or Thermidistatt is
selected as the thermostat.