Carrier 38QHF036, 38QHF025, 38QHF050, 38QHF060, 38QHF065 Installation Manual

...
900x315x860
590333
Right rear side refrigerant pipe hole 65φ
Left rear side refrigerant pipe hole 65φ
Indoor unit outline
45
42QHF025 :(A:800, B:275, C:100, D:95)
A
C
D
B
Right rear side refrigerant pipe hole 65φ
Left rear side refrigerant pipe hole 65φ
Indoor unit outline
45
A
C
D
B
42QHF036 / 42QHF050: (A:940, B:275, C:110, D:100)
Right rear side refrigerant pipe hole 65φ
Left rear side refrigerant pipe hole 65φ
Installation plate
A
21.5
C
D
B
45
42QHF060 / 42QHF065 : (A:1045, B:315, C:293, D:163)
Air freshening filter(1)
(used to install onAir filter)
6
Right rear side refrigerant pipe hole 65φ
Left rear side refrigerant pipe hole 65φ
Indoor unit outline
C
389
A
B
52
52
332
D
Indoor unit outline
42QHF080: (A:1259, B:362, C:172, D:257)
810x310x558
U
20cm or more
700x240x540
Model
38QHF025
38QHF036 / 38QHF050
845x320x700
38QHF060
38QHF065 / 38QHF080
The holes for fixing anchors should be 5mm.
Power supply from outdoor
Power supply
W 1 2(N ) S
W 1 2(N ) S L N
Do not p ut drai n end into water
Connection diagrams
Use a vacuum pump to evacuate air from the system until 76cmHg, do the reakage check before remove the charge hose.
Fully open the packed valve stem before test operation, use some leak detector or some soap water to check the refrigerant line connections.
Wire cross section is depending on the rated (max) current which is indicated as below:
Rated (max) current of appliance (A)
11. 5QHF025 / QHF036
12.5QHF050
14.5QHF060 / QHF065
16.0QHF080
For a ll QHF fa mily
1.Lift the indoor unit front panel.
2.Remove the indoor unit electrical cover and cord clamp by loosening the screws.
3.Pass the connecting wires from the back of indoor unit and connect to the indoor terminal block.
1. Remove the electrical cover and cord clamp by loosening the screws.
2. Connect wires to the outdoor terminal block by same sequence to indoor unit.
Press the ON/OFF button on remote control to begin testing.
Press MODE button, select COOL, HEAT, FAN mode to check if all functions work correctly.
Press the manual button once to energize the unit.
When ambient temperature is lower than 17 , the unit can not be controlled by remote control to run in cooling mode. For this condition, manual operation must be used.
Open front panel of the indoor unit;