Carrier 25HCR3C User Manual

25HCR3C Comfortt 13 Series Coastal Heat Pump w i t h R --- 2 2 Ref r i g e r a n t 1---1/2 to 5 Nominal Tons (Size 18 To 60)
Product Data
INDUSTRY LEADING FEATURES / BENEFITS
EFFICIENCY
13 SEER/ 10.8 EER / 8.0 -- 8.5 HSPF (nominal)
SOUND
Sound level as low as 71 dBA
COMFORT
System supports Thermidistatt or standard thermostat controls
RELIABILITY
Armor Platet coil fin corrosion protection
S Front--seating service valves S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High and Low pressure switch S Filter drier S Balanced refrigeration system for maximum reliability
DURABILITY
WeatherArmort protection package:
S Solid, durable sheet metal construction S Louvered coil guard S Baked--on, complete coverage, powder paint
APPLICATIONS
S Long-- line -- up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above evaporator, or up to 60 ft. (18.29 m) evaporator above condenser (See Longline Guide for more information.)
S Low ambient (down to --20_F/--28.9_C) with accessory
kit
WARRANTY
10 year limited compressor warranty / 5 yr parts
MODEL NUMBER NOMENCLATURE
12 3 4 5 6 78 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
25 H C R 3 36 C 0 0 3 0
Product
Series
25 = HP H = RES HP C=Comfort R = R ---22 3=13 SEER C = Coastal
25HCR3C
Product
Famil y
Tier
Major
Series
SEER
Cooling
Capacity
Variations Open Open V oltage
0=Not
Defined
ISO 9001:2000
REGISTERED
0=Not
Defined
This product has been designed and manuf actured to meet Ener gy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper ref rigerant c harge and proper air f low are cri tical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy efficiency a nd shorten equipment life.
3=208/230---1 0, 1, 2...
STANDARD FEATURES
Feature 18--- 30 24--- 30 30--- 30 36 ---30 48 --- 30 60--- 30
13 SEER X X X X X X
Scroll Compressor X X X X X X
Louvered Coil Guard X X X X X X
FieldInstalledFilterDrier X X X X X X
Front Seating Service Valves X X X X X X
Internal Pressure Relief Valve X X X X X X
Internal Thermal Overload X X X X X X
Long Line capability X X X X X X
Low Ambient capability with Kit X X X X X X
High Pressure Switch X X X X X X
Loss of Charge Pressure Switch X X X X X X
ArmorPlatet Condenser Coil Protection X X X X X X
Accumulator X X X X X X
Minor
Series
2
PHYSICAL DATA
UNIT SIZE ---SERIES, VOLTAGE 18 --- 30 24--- 30 30--- 30 36 --- 30 42 ---30 48 --- 30 60--- 30
Operating Weight lb (kg)
Shipping Weight lb (kg)
207
(93.9)
218
(98.9)
Compressor Type Scroll REFRIGERANT Freon( R --- 2 2 )
Control T X V ( R --- 2 2 H a r d S h u t o f f )
Charge lb (kg)
7
(3.2)
COND FAN
Air Discharge Vertical Air Qty (CFM) 2233 2614 3167 3334 3334 4046 4046 Motor HP 1/12 1/10 1/5 1/8 1/8 1/4 1/4 Motor RPM 800 800 800 800 800 800 800
COND COIL
Face Area (Sq ft) 19.4 21.56 19.40 25.15 17.60 25.15 30.18 Fins per In. 20 20 20 20 20 20 20 Rows 1 1 1 1 2 2 2 Circuits 5 6 6 6 8 8 11
VALVE CONNECT. (In.) ID
Vapor 5/8” 5/8” 3/4” 3/4” 7/8” 7/8” 7/8” Liquid 3/8”
REFRIGERANT TUBES* (in.)OD
Vapor (0---80 Ft Tube Length) 5/8” 5/8” 3/4” 3/4” 7/8” 7/8” 1 --- 1 / 8 Liquid (0 --- 80 Ft Tube Length) 3/8”
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation.
204
(92.5)
236
(107.1)
7
(3.2)
211
(95.7)
222
(100.7)
6.8
(3.1)
252
(114.3)
287
(130.2)
8.1
(3.7)
239
(108.4)
250
(113.4)
9.5
(4.3)
314
(142.4)
348
(157.9)
13.5 (6.1)
361
(163.8)
395
(179.2)
16.5 (7.5)
25HCR3C
VAPOR LINE SIZING AND COOLING CAPACITY LOSS 1--STAGE HEAT PUMP APPLICATIONS
LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m)
Unit Nominal
Size (Btuh)
18,000
R --- 22 H P
24,000
R --- 22 H P
30,000
R --- 22 H P
36,000
R --- 22 H P
42,000
R --- 22 H P
48,000
R --- 22 H P
60,000
R --- 22 H P
Acceptable
Vapo r L ine Diameters
(In.) OD
5/8 0 1 1 1 2 3 3 4 5 5 6 3/4 0 0 0 0 0 1 1 1 1 2 2 5/8 0 1 3 3 3 5 6 7 8 9 10 3/4 0 0 0 0 1 1 1 2 2 3 3 7/8 0 0 0 0 0 0 0 0 1 1 1 5/8 1 3 5 5 6 8 10 11 13 15 17 3/4 0 1 1 1 2 3 3 4 5 5 6 7/8 0 0 0 0 1 1 1 2 2 2 3 3/4 0 1 2 2 3 4 5 6 7 8 9 7/8 0 0 1 1 1 2 2 3 3 4 4 3/4 1 2 3 3 4 5 7 8 9 10 11 7/8 0 1 1 1 2 2 3 4 4 5 5 3/4 1 2 4 4 5 7 8 10 11 13 14 7/8 0 1 2 2 2 3 4 5 5 6 7
1 --- 1/8 0 0 0 0 0 0 1 1 1 1 1
7/8 1 2 3 3 4 5 7 8 9 10 11
1 --- 1/8 0 0 1 1 1 1 2 2 2 3 3
Standard Application Long Line Application R equires Accessories
25
(7.62)50(15.24)80(24.38)
80+
(24.38+)
Standard Length = 80 ft. (24.38 m) or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
when outdoor unit is above indoor unit, and 60 ft. (18.29 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss.
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
100
(30.48)
125
(38.10)
150
(45.72)
175
(53.34)
200
(60.96)
225
(68.58)
(76.2)
250
3
ACCESSORY THERMOSTATS
THERMOSTAT / SUBBASE PKG. DESCRIPTION
Thermidistatt Control — Non---Programmable/Programmable Thermostat with
TSTATCCPRH01 --- B*
TSTATCCPHH01 --- B*
TSTATCCPHP01--- B
TSTATCCNHP01--- C
TSTATCCSHP01
TSTATCCBHP01*--- B
TSTATXXSEN01---B** Outdoor Air Temperature Sensor TSTATXXNBP01 Backplate for Non --- Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistatt Control TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder’s Thermostat TSTATXXCNV10{ Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack T P --- P R H --- 0 1 Performance Series Programmable Thermidistat
T P --- N R H --- 0 1 Performance Series Non--- programmable Thermidistat
25HCR3C
T P --- P H P --- 0 1 Performance Series Programmable HP Stat
T P --- N H P --- 0 1 Performance Series Non --- programmable HP Stat
T C --- P H P --- 0 1 Comfort Series Programmable HP Stat
T C --- N H P --- 0 1 Comfort Series Non ---programmable HP Stat
T B --- P H P --- 0 1 Base Series P rog rammable HP Stat
T B --- N H P --- 0 1 Base Series Non--- programmable HP Stat
* Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non --- programmable air conditioner version and builder;s
thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
{ Th ermostat conversion kit is a 24---vac accessory that can turn a 4 ---wire thermostat application into a 5 ---wire application. This kit can also be used to
replace a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control and HybridHeatt (dual fuel) thermostat.
Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Out­door Air Temperature Sensor.)
HybridHeatt (Dual Fuel) Thermostat — Auto Changeover, 7 --- Day Programmable, °F/°C, Includes Outdoor Sensor (TSTATXXSEN01--- B)
Thermostat — Auto Changeover, 7 --- Day Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C oo l
Thermostat — Auto Changeover, Non --- Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C oo l
Standard Programmable Thermostat—Manual Changeover, 5 --- 2 Day Program­mable, °F/°C , 1 --- S t a g e H e a t / 1 --- S t a g e C o o l
Builder’s Thermostat — Heat Pump, Non--- Programmable, °F/°C , 2 --- S t a g e He a t , 1--- Stage Cool, Manual Changeover
ACCESSORIES
ORDER NUMBER DESCRIPTION 18 --- 30 24 ---30 30 --- 30 36 ---30 42 ---30 48--- 30 60 ---30
HC32GE229 BALL BEARING MOTOR X HC34GE242 BALL BEARING MOTOR X HC36GE232 BALL BEARING MOTOR X X HC38GE228 BALL BEARING MOTOR X HC40GE228 BALL BEARING MOTOR X X KAACH1201AAA CRANKCASE HTR X S S KAACH1401AAA CRANKCASE HTR X KAACH1601AAA CRANKCASE HTR X X KAACH1701AAA CRANKCASE HTR X X KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X KSAHS1501AAA HARD START X X X X X X KSAHS1601AAA HARD START X KHAIR0101AAA ISOLATION RELAY X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KSALA0201R22 LOW AMBIENT X X X X X X X KSALA0601AAA MOTORMASTER 230V X X X X X X X KHAOT0201SEC OUTDOOR THERMOSTAT X X X X X X X KHAOT0301FST OUTDOOR THERMOSTAT X X X X X X X KHASS0606MPK SNOW STAND X X X X X X X KHALS0401LLS SOLENOID VALVE X X X X X X X KAACS0201PTC STARTASSISTPTC X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAATD0101TDR TIME DELAY X X X X X X X KSATX0601HSO TXV X X X X X KSATX0701HSO TXV X KSATX1001HSO TXV X
X = Accessory S = Standard
4
ACCESSORY USAGE GUIDELINE
Accessory
Ball Bearing Fan Motor Yes{ No No
Compressor Start Assist
Capacitor and Relay
Crankcase Heater Ye s{ Yes No
Evaporator Freeze Thermostat Yes{ No No
Isolation Relay Yes{ No No
Liquid Line Solenoid Valve No
Motor Master®Control
o r L o w --- a m b i e n t P r e s s u r e S w i t c h
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) an d/or 20 ft. vertical (6.09 m) differential, refer to Residential Split System Long Line
Application Guideline.
{ Required for Low---Ambient Controller MotorMasterr Control only.
Support Feet Recommended No Recommended
LOW---AMBIENT APPLICATIONS
REQUIRED FOR
(Below 55° F / 12.78° C)
Yes{ Yes No
Yes{ No No
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMasterr is used.
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the following applications:
Long line Low ambient cooling
Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications. Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5--minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions.
7. High Pressure Switch
A high pressure switch that protects unit against excessive pressure.
8. Isolation Relay
An SPDT relay which switches the low--ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode.
9. Liquid--Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode.
10. Low-- Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low--ambient temperatures down to 0_F/--17.78_C when properly installed.
REQUIRED FOR LONG
LINE APPLICATIONS* (Over 80 Ft. / 24.38 m)
See Long Line Application
Guideline
REQUIRED FOR SEA
COAST APPLICATIONS
(Within2miles/3.22km)
No
Usage Guideline:
Required when low ambient kit has been added.
Usage Guideline:
Required in all heat pumps operated in dual fuel applications.
Usage Guideline:
Required in all heat pumps where low ambient kit has been added.
Usage Guideline:
An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
25HCR3C
5
Accessory Description and Usage (Listed Alphabetically) -- CONTINUED
11. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -- 20_F (-- 28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ±
5.5_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
Suggested for all commercial applications.
12. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
Usage Guideline:
25HCR3C
13. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user--selected set point.
14. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on third--stage of supplemental electric heaters when outdoor air temperature drops below the second--stage set point.
capable of 3--stage operation.
15. Snow Stand
Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base.
Suggested for all Carrier thermostats listed in this publication.
Usage Guideline:
Electric supplemental heat applications in non--variable speed indoor units when electric heat staging is desired.
Usage Guideline:
Some local codes may require limiting the heating head pressure in the vapor line in some applications.
Usage Guideline:
Outdoor thermostat applications where electric heater is
Usage Guideline:
Suggested in the following applications:
Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations.
Heat pump installations in areas of prolonged subfreezing temperatures.
All commercial installations.
16. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the sound level up to 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart.
Usage Guideline:
Suggested in the following applications: Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged
subfreezing temperatures. All commercial installations.
17. Thermostatic Expansion Valve (TXV) Bi--Flow
A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.
Usage Guideline:
Required in all heat pump applications
18. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor not equipped.
6
ELECTRICAL DATA
MIN
UNIT SIZE V/PH
18
24 54 15.13 0.7 19.6 14 14
30 72.5 13.50 1.2 18.6 14 14
36 88 18.68 0.9 24.2 12 12
42 104 17.90 0.9 24.0 12 12
48 137 22.22 1.2 29.0 10 10
60 148 28.85 1.2 37.3 8 8
* Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30° C, consult table 310---16 of the NE C (ANSI/NFPA 70). The ampacity of non---metallic ---sheathed cable (NM),
trade name ROMEX, shall be that of 60° C conditions, per the NEC ( ANSI/NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75° C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA
70). } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. * * T i m e --- D e l a y f u se. F L A --- F u ll L oad Am p s LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24--- V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
208/230/1---60 253 197
OPER VOLTS* COMPR FAN
MAX MIN LRA RLA FLA 60˚ C 75˚ C 60˚ C 75˚ C
41 9.8 0.5 12.7 14 14
MCA
WIRE SIZE†
MIN
WIRE
SIZE†
MAX
LENGTH
ft.(m)‡
124
(37.80)
80
(23.16)
85
(25.91)
103|
(31.39)
104
(31.70)
138
(42.06)
167
(50.90)
MAX
LENGTH
ft.(m)‡
118
(35.97)
76
(23.16)
81
(24.69)
98
(29.87)
99
(30.18)
131
(39.93)
159
(48.46)
MAX
FUSE**
or BRK
AMPS
20
30
30
40
40
50
60
25HCR3C
A--WEIGHTED SOUND LEVEL (dBA)
STANDARD
UNIT SIZE
18 71 55 58 64.5 65 64.5 63 55.5 24 74 57.0 62.5 68.5 69.5 67.5 63.0 55.0 30 73 58.0 66.0 66.0 67.5 64.5 61.0 54.5 36 74 53.5 65.5 64.5 68.5 66.0 62.0 54.5 42 74 59.0 62.0 66.0 69.0 65.0 60.0 51.5 48 75 54.5 61.0 66.0 71.0 65.5 62.0 56.5 60 75 56.5 66.5 67.5 69.5 67.5 63.5 56.5
RATING
(dB)
TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)
125 250 500 1000 2000 4000 8000
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE ---SERIES REQUIRED SUBCOOLING _F(_C) Heating Piston Size
18 10 (5.6) 42 24 10 (5.6) 52 30 10 (5.6) 57 36 10 (5.6) 57 42 10 (5.6) 67 48 9 (5.0) 67 60 10 (5.6) 78
7
25HCR3C
DIMENSIONS
8
kW
23.4
20.5
25HCR360C
FC4DN(F,B)060
17.6
25HCR348C
FC4DN(F,B)048
14.6
25HCR342C
FC4DN(F,B)042
11.7
25HCR330C
25HCR336C
FC4DN(F,B)036
8.8
25HCR324C
FC4DNF030
FA4CN(F,C)024
5.9
25HCR318C
FA4CN(F,C)018
2.9
BASED ON INDOOR ENT. AIR
0.0
AT 70 º F AN D AT RATED CFM
25HCR3C
25HCR3C BALANCE POINT WORKSHEET
80.00
70.00
60.00
50.00
40.00
30.00
CAPACITY, MBTUH
20.00
BUILDING HEAT LOSS, UNIT INTEGRATED HEATING
10.00
OUTDOOR TEMPERATURE, _F(_C)
--10 (23) 0 (--17.78) 10 (--12.22) 20 (--6.67) 30 (--1.11) 40 (4.44) 50 (10) 60 (15.56) 70 (21.11) 80 (26.67)
0.00
9
COMBINATION RATINGS
Unit
S i z e ---
Volt age ,
Series
Indoor Model
*FA4CN(F,C)018 17,000 TDR&TXV 13.00 10.80 18,000 3.40 10,500 2.30 7.7
FA4CN(F,C)024 17,000 TDR&TXV 13.00 10.80 17,300 3.30 10,600 2.28 7.7
FC4DNF018 17,300 TDR&TXV 14.50 12.00 17,600 3.62 10,100 2.46 8.2 FC4DNF024 17,500 TDR&TXV 14.50 12.50 16,800 3.58 10,100 2.48 8.2 FF1ENE018 16,900 TDR&TXV 13.00 10.80 18,000 3.40 10,500 2.28 7.7 FF1ENE024 17,100 TDR&TXV 13.00 10.80 17,100 3.36 10,500 2.32 7.7 FK4DNF001 17,300 TDR&TXV 15.00 12.50 16,400 3.52 9,900 2.46 8.2 FK4DNF002 17,500 TDR&TXV 15.00 12.50 16,400 3.64 9,900 2.50 8.4
CAR**1814A** 16,700 TDR&TXV 14.50 12.00 17,400 3.38 9,900 2.38 7.7 58CV(A,X)070--- 12
CAR**2414A** 17,100 TDR&TXV 14.50 12.50 17,100 3.56 9,900 2.44 8.0 58CV(A,X)070--- 12 CAR**2414A** 17,200 TXV 13.00 10.80 17,200 3.38 10,500 2.32 7.7
CAR**2417A** 17,200 TDR&TXV 14.50 12.50 17,100 3.58 9,900 2.46 8.2 58CV(A,X)090--- 16 CAR**2417A** 17,200 TDR&TXV 14.50 12.50 17,100 3.56 9,900 2.44 8.2 58MVB060---14 CAR**2417A** 17,200 TDR&TXV 14.50 12.50 17,100 3.56 9,900 2.44 8.2 58UVB060--- 14 CAR**2417A** 17,200 TXV 13.00 10.80 17,200 3.38 10,500 2.32 7.7
CNRF*2418A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
Cooling
Capa-
city
Enhance
Factory
Cooling Heating
Standard
Rating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
25HCR3C
18---30
CNRH*2417A** 17,200 TDR&TXV 14.50 12.50 17,500 3.66 9,900 2.44 8.2 58CV(A,X)070---12 CNRH*2417A** 17,300 TDR&TXV 14.50 12.50 17,400 3.68 10,000 2.46 8.2 58CV(A,X)090--- 16 CNRH*2417A** 17,200 TDR&TXV 14.50 12.50 17,400 3.66 9,900 2.44 8.2 58MVB040---14 CNRH*2417A** 17,200 TDR&TXV 14.50 12.50 17,500 3.68 9,900 2.44 8.2 58MVB060---14 CNRH*2417A** 17,300 TDR&TXV 14.50 12.50 17,400 3.68 10,000 2.46 8.2 58MVB080--- 14 CNRH*2417A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
CNRV*1814A** 17,100 TDR&TXV 14.50 12.00 17,700 3.58 9,900 2.42 8.0 58CV(A ,X)070--- 12 CNRV*1814A** 17,100 TXV 13.00 10.80 17,800 3.46 10,500 2.32 7.7
CNRV*2414A** 17,200 TDR&TXV 14.50 12.50 17,500 3.66 9,900 2.44 8.2 58CV(A ,X)070--- 12 CNRV*2414A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
CNRV*2417A** 17,300 TDR&TXV 14.50 12.50 17,400 3.68 10,000 2.46 8.2 58CV(A,X)090---16 CNRV*2417A** 17,200 TDR&TXV 14.50 12.50 17,400 3.66 9,900 2.44 8.2 58MVB060--- 14 CNRV*2417A** 17,200 TDR&TXV 14.50 12.50 17,400 3.66 9,900 2.44 8.2 58UVB060 ---14 CNRV*2417A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
CSRH*2412A** 17,300 TDR&TXV 14.50 12.50 16,900 3.58 10,000 2.44 8.2 58CV(A,X)070---12 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58CV(A,X)090---16 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58MVB040 ---14 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58MVB060 ---14 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58MVB080 ---14 CSRH*2412A** 17,400 TXV 13.20 11.00 16,100 3.32 10,600 2.34 7.7
*FA4CN(F,C)024 23,200 TDR&TXV 13.00 10.80 24,000 3.54 14,800 2.38 8.3
FA4CN(F,C)030 23,600 TDR&TXV 13.20 11.00 24,000 3.60 14,800 2.42 8.5
FC4DNF024 23,800 TDR&TXV 14.00 12.00 24,000 3.72 14,400 2.52 8.7 FC4DNF030 24,000 TDR&TXV 14.50 12.00 24,000 3.82 14,400 2.56 8.8 FF1ENE024 23,400 TDR&TXV 13.00 10.80 24,000 3.54 14,900 2.38 8.3 FF1ENE030 23,400 TDR&TXV 13.00 10.80 24,000 3.56 14,900 2.38 8.4
FK4DN(B,F)003 23,800 TDR&TXV 15.00 12.50 23,400 3.80 14,100 2.58 8.8
FK4DNF001 23,600 TDR&TXV 14.50 12.00 23,800 3.70 14,200 2.52 8.6 FK4DNF002 24,000 TDR&TXV 15.00 12.50 23,800 3.82 14,200 2.56 8.8
CAR**2414A** 23,400 TDR&TXV 14.50 11.70 23,800 3.66 14,200 2.50 8.6 58CV(A,X)070--- 12 CAR**2414A** 23,400 TXV 13.00 10.80 24,000 3.60 14,900 2.40 8.5
CAR**2417A** 23,400 TDR&TXV 14.50 11.70 23,600 3.70 14,100 2.54 8.6 58CV(A,X)090--- 16 CAR**2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.68 14,100 2.52 8.6 58MVB060 ---14
24---30
CAR**2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.68 14,100 2.52 8.6 58UVB060 --- 14 CAR**2417A** 23,400 TXV 13.00 10.80 24,000 3.60 14,900 2.40 8.5
CAR**3014A** 23,400 TDR&TXV 14.50 11.70 23,600 3.70 14,200 2.52 8.6 58CV(A,X)070--- 12 CAR**3014A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CAR**3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,100 2.54 8.7 58CV(A,X)090--- 16 CAR**3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58MVB060 ---14 CAR**3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58UVB060 --- 14 CAR**3017A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CNRF*2418A** 23,400 TXV 13.00 10.80 24,000 3.68 15,000 2.42 8.6
CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.72 14,200 2.52 8.7 58CV(A ,X)070--- 12 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.54 8.7 58CV(A ,X)090--- 16 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58CV(A ,X)110--- 20
See notes on page 16
10