Carrier 25HCR3C User Manual

Page 1
25HCR3C Comfortt 13 Series Coastal Heat Pump w i t h R --- 2 2 Ref r i g e r a n t 1---1/2 to 5 Nominal Tons (Size 18 To 60)
Product Data
INDUSTRY LEADING FEATURES / BENEFITS
EFFICIENCY
13 SEER/ 10.8 EER / 8.0 -- 8.5 HSPF (nominal)
SOUND
Sound level as low as 71 dBA
COMFORT
System supports Thermidistatt or standard thermostat controls
RELIABILITY
Armor Platet coil fin corrosion protection
S Front--seating service valves S Scroll compressor S Internal pressure relief valve S Internal thermal overload S High and Low pressure switch S Filter drier S Balanced refrigeration system for maximum reliability
DURABILITY
WeatherArmort protection package:
S Solid, durable sheet metal construction S Louvered coil guard S Baked--on, complete coverage, powder paint
APPLICATIONS
S Long-- line -- up to 250 feet (76.20 m) total equivalent
length, up to 200 feet (60.96 m) condenser above evaporator, or up to 60 ft. (18.29 m) evaporator above condenser (See Longline Guide for more information.)
S Low ambient (down to --20_F/--28.9_C) with accessory
kit
WARRANTY
10 year limited compressor warranty / 5 yr parts
Page 2
MODEL NUMBER NOMENCLATURE
12 3 4 5 6 78 9 10 11 12 13
N N A A A/N N N N A/N A/N A/N N N
25 H C R 3 36 C 0 0 3 0
Product
Series
25 = HP H = RES HP C=Comfort R = R ---22 3=13 SEER C = Coastal
25HCR3C
Product
Famil y
Tier
Major
Series
SEER
Cooling
Capacity
Variations Open Open V oltage
0=Not
Defined
ISO 9001:2000
REGISTERED
0=Not
Defined
This product has been designed and manuf actured to meet Ener gy Star® criteria for energy efficiency when matched with appropriate coil components. However, proper ref rigerant c harge and proper air f low are cri tical to achieve rated capacity and efficiency. Installation of this product should follow all manufacturing refrigerant charging and air flow instructions. Failure to confirm
proper charge and air flow may reduce energy efficiency a nd shorten equipment life.
3=208/230---1 0, 1, 2...
STANDARD FEATURES
Feature 18--- 30 24--- 30 30--- 30 36 ---30 48 --- 30 60--- 30
13 SEER X X X X X X
Scroll Compressor X X X X X X
Louvered Coil Guard X X X X X X
FieldInstalledFilterDrier X X X X X X
Front Seating Service Valves X X X X X X
Internal Pressure Relief Valve X X X X X X
Internal Thermal Overload X X X X X X
Long Line capability X X X X X X
Low Ambient capability with Kit X X X X X X
High Pressure Switch X X X X X X
Loss of Charge Pressure Switch X X X X X X
ArmorPlatet Condenser Coil Protection X X X X X X
Accumulator X X X X X X
Minor
Series
2
Page 3
PHYSICAL DATA
UNIT SIZE ---SERIES, VOLTAGE 18 --- 30 24--- 30 30--- 30 36 --- 30 42 ---30 48 --- 30 60--- 30
Operating Weight lb (kg)
Shipping Weight lb (kg)
207
(93.9)
218
(98.9)
Compressor Type Scroll REFRIGERANT Freon( R --- 2 2 )
Control T X V ( R --- 2 2 H a r d S h u t o f f )
Charge lb (kg)
7
(3.2)
COND FAN
Air Discharge Vertical Air Qty (CFM) 2233 2614 3167 3334 3334 4046 4046 Motor HP 1/12 1/10 1/5 1/8 1/8 1/4 1/4 Motor RPM 800 800 800 800 800 800 800
COND COIL
Face Area (Sq ft) 19.4 21.56 19.40 25.15 17.60 25.15 30.18 Fins per In. 20 20 20 20 20 20 20 Rows 1 1 1 1 2 2 2 Circuits 5 6 6 6 8 8 11
VALVE CONNECT. (In.) ID
Vapor 5/8” 5/8” 3/4” 3/4” 7/8” 7/8” 7/8” Liquid 3/8”
REFRIGERANT TUBES* (in.)OD
Vapor (0---80 Ft Tube Length) 5/8” 5/8” 3/4” 3/4” 7/8” 7/8” 1 --- 1 / 8 Liquid (0 --- 80 Ft Tube Length) 3/8”
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation.
204
(92.5)
236
(107.1)
7
(3.2)
211
(95.7)
222
(100.7)
6.8
(3.1)
252
(114.3)
287
(130.2)
8.1
(3.7)
239
(108.4)
250
(113.4)
9.5
(4.3)
314
(142.4)
348
(157.9)
13.5 (6.1)
361
(163.8)
395
(179.2)
16.5 (7.5)
25HCR3C
VAPOR LINE SIZING AND COOLING CAPACITY LOSS 1--STAGE HEAT PUMP APPLICATIONS
LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. (24.38 m) or when there is more than 20 ft. (6.09 m) vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. (76.2 m). The maximum vertical separation is 200 ft. (60.96 m)
Unit Nominal
Size (Btuh)
18,000
R --- 22 H P
24,000
R --- 22 H P
30,000
R --- 22 H P
36,000
R --- 22 H P
42,000
R --- 22 H P
48,000
R --- 22 H P
60,000
R --- 22 H P
Acceptable
Vapo r L ine Diameters
(In.) OD
5/8 0 1 1 1 2 3 3 4 5 5 6 3/4 0 0 0 0 0 1 1 1 1 2 2 5/8 0 1 3 3 3 5 6 7 8 9 10 3/4 0 0 0 0 1 1 1 2 2 3 3 7/8 0 0 0 0 0 0 0 0 1 1 1 5/8 1 3 5 5 6 8 10 11 13 15 17 3/4 0 1 1 1 2 3 3 4 5 5 6 7/8 0 0 0 0 1 1 1 2 2 2 3 3/4 0 1 2 2 3 4 5 6 7 8 9 7/8 0 0 1 1 1 2 2 3 3 4 4 3/4 1 2 3 3 4 5 7 8 9 10 11 7/8 0 1 1 1 2 2 3 4 4 5 5 3/4 1 2 4 4 5 7 8 10 11 13 14 7/8 0 1 2 2 2 3 4 5 5 6 7
1 --- 1/8 0 0 0 0 0 0 1 1 1 1 1
7/8 1 2 3 3 4 5 7 8 9 10 11
1 --- 1/8 0 0 1 1 1 1 2 2 2 3 3
Standard Application Long Line Application R equires Accessories
25
(7.62)50(15.24)80(24.38)
80+
(24.38+)
Standard Length = 80 ft. (24.38 m) or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines
when outdoor unit is above indoor unit, and 60 ft. (18.29 m) when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Longline Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss.
Cooling Capacity Loss (%)
Total Equivalent Line Length ft. (m)
100
(30.48)
125
(38.10)
150
(45.72)
175
(53.34)
200
(60.96)
225
(68.58)
(76.2)
250
3
Page 4
ACCESSORY THERMOSTATS
THERMOSTAT / SUBBASE PKG. DESCRIPTION
Thermidistatt Control — Non---Programmable/Programmable Thermostat with
TSTATCCPRH01 --- B*
TSTATCCPHH01 --- B*
TSTATCCPHP01--- B
TSTATCCNHP01--- C
TSTATCCSHP01
TSTATCCBHP01*--- B
TSTATXXSEN01---B** Outdoor Air Temperature Sensor TSTATXXNBP01 Backplate for Non --- Programmable Thermostat TSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistatt Control TSTATXXSBP01 Backplate for Standard Programmable Thermostat TSTATXXBBP01 Backplate for Builder’s Thermostat TSTATXXCNV10{ Thermostat Conversion Kit (4 to 5 Wire) — 10 Pack T P --- P R H --- 0 1 Performance Series Programmable Thermidistat
T P --- N R H --- 0 1 Performance Series Non--- programmable Thermidistat
25HCR3C
T P --- P H P --- 0 1 Performance Series Programmable HP Stat
T P --- N H P --- 0 1 Performance Series Non --- programmable HP Stat
T C --- P H P --- 0 1 Comfort Series Programmable HP Stat
T C --- N H P --- 0 1 Comfort Series Non ---programmable HP Stat
T B --- P H P --- 0 1 Base Series P rog rammable HP Stat
T B --- N H P --- 0 1 Base Series Non--- programmable HP Stat
* Do not use in zoning heat pump applications. ** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non --- programmable air conditioner version and builder;s
thermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be used with the HybridHeatt (dual fuel) thermostat.
{ Th ermostat conversion kit is a 24---vac accessory that can turn a 4 ---wire thermostat application into a 5 ---wire application. This kit can also be used to
replace a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control and HybridHeatt (dual fuel) thermostat.
Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Out­door Air Temperature Sensor.)
HybridHeatt (Dual Fuel) Thermostat — Auto Changeover, 7 --- Day Programmable, °F/°C, Includes Outdoor Sensor (TSTATXXSEN01--- B)
Thermostat — Auto Changeover, 7 --- Day Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C oo l
Thermostat — Auto Changeover, Non --- Programmable, °F/°C , 2 --- S t a g e H e a t , 1 --- S t a g e C oo l
Standard Programmable Thermostat—Manual Changeover, 5 --- 2 Day Program­mable, °F/°C , 1 --- S t a g e H e a t / 1 --- S t a g e C o o l
Builder’s Thermostat — Heat Pump, Non--- Programmable, °F/°C , 2 --- S t a g e He a t , 1--- Stage Cool, Manual Changeover
ACCESSORIES
ORDER NUMBER DESCRIPTION 18 --- 30 24 ---30 30 --- 30 36 ---30 42 ---30 48--- 30 60 ---30
HC32GE229 BALL BEARING MOTOR X HC34GE242 BALL BEARING MOTOR X HC36GE232 BALL BEARING MOTOR X X HC38GE228 BALL BEARING MOTOR X HC40GE228 BALL BEARING MOTOR X X KAACH1201AAA CRANKCASE HTR X S S KAACH1401AAA CRANKCASE HTR X KAACH1601AAA CRANKCASE HTR X X KAACH1701AAA CRANKCASE HTR X X KAAFT0101AAA FREEZE THERMOSTAT X X X X X X X KSAHS1501AAA HARD START X X X X X X KSAHS1601AAA HARD START X KHAIR0101AAA ISOLATION RELAY X X X X X X X KSACY0101AAA CYCLE PROTECTOR X X X X X X X KSALA0201R22 LOW AMBIENT X X X X X X X KSALA0601AAA MOTORMASTER 230V X X X X X X X KHAOT0201SEC OUTDOOR THERMOSTAT X X X X X X X KHAOT0301FST OUTDOOR THERMOSTAT X X X X X X X KHASS0606MPK SNOW STAND X X X X X X X KHALS0401LLS SOLENOID VALVE X X X X X X X KAACS0201PTC STARTASSISTPTC X X X X X X X KSASF0101AAA SUPPORT FEET X X X X X X X KAATD0101TDR TIME DELAY X X X X X X X KSATX0601HSO TXV X X X X X KSATX0701HSO TXV X KSATX1001HSO TXV X
X = Accessory S = Standard
4
Page 5
ACCESSORY USAGE GUIDELINE
Accessory
Ball Bearing Fan Motor Yes{ No No
Compressor Start Assist
Capacitor and Relay
Crankcase Heater Ye s{ Yes No
Evaporator Freeze Thermostat Yes{ No No
Isolation Relay Yes{ No No
Liquid Line Solenoid Valve No
Motor Master®Control
o r L o w --- a m b i e n t P r e s s u r e S w i t c h
* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) an d/or 20 ft. vertical (6.09 m) differential, refer to Residential Split System Long Line
Application Guideline.
{ Required for Low---Ambient Controller MotorMasterr Control only.
Support Feet Recommended No Recommended
LOW---AMBIENT APPLICATIONS
REQUIRED FOR
(Below 55° F / 12.78° C)
Yes{ Yes No
Yes{ No No
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when MotorMasterr is used.
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the following applications:
Long line Low ambient cooling
Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil
Required for single--phase scroll compressors in the following applications:
Long line
Low ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.
3. Compressor Start Assist — PTC Type
Solid state electrical device which gives a ”soft” boost to the compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.
Usage Guideline:
Required in low ambient cooling applications.
Required in long line applications. Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5--minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions.
7. High Pressure Switch
A high pressure switch that protects unit against excessive pressure.
8. Isolation Relay
An SPDT relay which switches the low--ambient controller out of the outdoor fan motor circuit when the heat pump switches to heating mode.
9. Liquid--Line Solenoid Valve (LLS)
An electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It is to be installed at the outdoor unit to control refrigerant off cycle migration in the heating mode.
10. Low-- Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low--ambient temperatures down to 0_F/--17.78_C when properly installed.
REQUIRED FOR LONG
LINE APPLICATIONS* (Over 80 Ft. / 24.38 m)
See Long Line Application
Guideline
REQUIRED FOR SEA
COAST APPLICATIONS
(Within2miles/3.22km)
No
Usage Guideline:
Required when low ambient kit has been added.
Usage Guideline:
Required in all heat pumps operated in dual fuel applications.
Usage Guideline:
Required in all heat pumps where low ambient kit has been added.
Usage Guideline:
An LLS is required in all long line heat pump applications to control refrigerant off cycle migration in the heating mode. See Long Line Guideline.
Usage Guideline:
A Low--Ambient Pressure Switch or MotorMasterr Low--Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
25HCR3C
5
Page 6
Accessory Description and Usage (Listed Alphabetically) -- CONTINUED
11. MotorMasterr Low--Ambient Controller
A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to -- 20_F (-- 28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ±
5.5_C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
Suggested for all commercial applications.
12. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out.
Usage Guideline:
25HCR3C
13. Outdoor Thermostat
An SPDT temperature--actuated switch which turns on supplemental electric heaters when outdoor air temperature drops below a user--selected set point.
14. Secondary Outdoor Thermostat
An SPDT temperature--actuated switch which turns on third--stage of supplemental electric heaters when outdoor air temperature drops below the second--stage set point.
capable of 3--stage operation.
15. Snow Stand
Coated wire rack which supports unit 18 in. (457.2 mm) above mounting pad to allow for drainage from unit base.
Suggested for all Carrier thermostats listed in this publication.
Usage Guideline:
Electric supplemental heat applications in non--variable speed indoor units when electric heat staging is desired.
Usage Guideline:
Some local codes may require limiting the heating head pressure in the vapor line in some applications.
Usage Guideline:
Outdoor thermostat applications where electric heater is
Usage Guideline:
Suggested in the following applications:
Heat pump installations in heavy snowfall areas. Heat pump installations in snow drift locations.
Heat pump installations in areas of prolonged subfreezing temperatures.
All commercial installations.
16. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the sound level up to 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft (4.57 m) to quiet areas, bedrooms, etc.
Suggested when unit is installed between two houses less than 10 ft (3.05 m) apart.
Usage Guideline:
Suggested in the following applications: Heat pump installations in heavy snowfall areas.
Heat pump installations in snowdrift locations. Heat pump installations in areas of prolonged
subfreezing temperatures. All commercial installations.
17. Thermostatic Expansion Valve (TXV) Bi--Flow
A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.
Usage Guideline:
Required in all heat pump applications
18. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor not equipped.
6
Page 7
ELECTRICAL DATA
MIN
UNIT SIZE V/PH
18
24 54 15.13 0.7 19.6 14 14
30 72.5 13.50 1.2 18.6 14 14
36 88 18.68 0.9 24.2 12 12
42 104 17.90 0.9 24.0 12 12
48 137 22.22 1.2 29.0 10 10
60 148 28.85 1.2 37.3 8 8
* Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30° C, consult table 310---16 of the NE C (ANSI/NFPA 70). The ampacity of non---metallic ---sheathed cable (NM),
trade name ROMEX, shall be that of 60° C conditions, per the NEC ( ANSI/NFPA 70) Article 336 ---26. If other than uncoated (no ---plated), 60 or 75° C insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA
70). } Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. * * T i m e --- D e l a y f u se. F L A --- F u ll L oad Am p s LRA --- Locked Rotor Amps MCA --- Minimum Circuit Amps RLA --- Rated Load Amps NOTE: Control circuit is 24--- V on all units and requires external power source. Copper wire must be used from service disconnect to unit.
All motors/compressors contain internal overload protection.
208/230/1---60 253 197
OPER VOLTS* COMPR FAN
MAX MIN LRA RLA FLA 60˚ C 75˚ C 60˚ C 75˚ C
41 9.8 0.5 12.7 14 14
MCA
WIRE SIZE†
MIN
WIRE
SIZE†
MAX
LENGTH
ft.(m)‡
124
(37.80)
80
(23.16)
85
(25.91)
103|
(31.39)
104
(31.70)
138
(42.06)
167
(50.90)
MAX
LENGTH
ft.(m)‡
118
(35.97)
76
(23.16)
81
(24.69)
98
(29.87)
99
(30.18)
131
(39.93)
159
(48.46)
MAX
FUSE**
or BRK
AMPS
20
30
30
40
40
50
60
25HCR3C
A--WEIGHTED SOUND LEVEL (dBA)
STANDARD
UNIT SIZE
18 71 55 58 64.5 65 64.5 63 55.5 24 74 57.0 62.5 68.5 69.5 67.5 63.0 55.0 30 73 58.0 66.0 66.0 67.5 64.5 61.0 54.5 36 74 53.5 65.5 64.5 68.5 66.0 62.0 54.5 42 74 59.0 62.0 66.0 69.0 65.0 60.0 51.5 48 75 54.5 61.0 66.0 71.0 65.5 62.0 56.5 60 75 56.5 66.5 67.5 69.5 67.5 63.5 56.5
RATING
(dB)
TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)
125 250 500 1000 2000 4000 8000
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVICE)
UNIT SIZE ---SERIES REQUIRED SUBCOOLING _F(_C) Heating Piston Size
18 10 (5.6) 42 24 10 (5.6) 52 30 10 (5.6) 57 36 10 (5.6) 57 42 10 (5.6) 67 48 9 (5.0) 67 60 10 (5.6) 78
7
Page 8
25HCR3C
DIMENSIONS
8
Page 9
kW
23.4
20.5
25HCR360C
FC4DN(F,B)060
17.6
25HCR348C
FC4DN(F,B)048
14.6
25HCR342C
FC4DN(F,B)042
11.7
25HCR330C
25HCR336C
FC4DN(F,B)036
8.8
25HCR324C
FC4DNF030
FA4CN(F,C)024
5.9
25HCR318C
FA4CN(F,C)018
2.9
BASED ON INDOOR ENT. AIR
0.0
AT 70 º F AN D AT RATED CFM
25HCR3C
25HCR3C BALANCE POINT WORKSHEET
80.00
70.00
60.00
50.00
40.00
30.00
CAPACITY, MBTUH
20.00
BUILDING HEAT LOSS, UNIT INTEGRATED HEATING
10.00
OUTDOOR TEMPERATURE, _F(_C)
--10 (23) 0 (--17.78) 10 (--12.22) 20 (--6.67) 30 (--1.11) 40 (4.44) 50 (10) 60 (15.56) 70 (21.11) 80 (26.67)
0.00
9
Page 10
COMBINATION RATINGS
Unit
S i z e ---
Volt age ,
Series
Indoor Model
*FA4CN(F,C)018 17,000 TDR&TXV 13.00 10.80 18,000 3.40 10,500 2.30 7.7
FA4CN(F,C)024 17,000 TDR&TXV 13.00 10.80 17,300 3.30 10,600 2.28 7.7
FC4DNF018 17,300 TDR&TXV 14.50 12.00 17,600 3.62 10,100 2.46 8.2 FC4DNF024 17,500 TDR&TXV 14.50 12.50 16,800 3.58 10,100 2.48 8.2 FF1ENE018 16,900 TDR&TXV 13.00 10.80 18,000 3.40 10,500 2.28 7.7 FF1ENE024 17,100 TDR&TXV 13.00 10.80 17,100 3.36 10,500 2.32 7.7 FK4DNF001 17,300 TDR&TXV 15.00 12.50 16,400 3.52 9,900 2.46 8.2 FK4DNF002 17,500 TDR&TXV 15.00 12.50 16,400 3.64 9,900 2.50 8.4
CAR**1814A** 16,700 TDR&TXV 14.50 12.00 17,400 3.38 9,900 2.38 7.7 58CV(A,X)070--- 12
CAR**2414A** 17,100 TDR&TXV 14.50 12.50 17,100 3.56 9,900 2.44 8.0 58CV(A,X)070--- 12 CAR**2414A** 17,200 TXV 13.00 10.80 17,200 3.38 10,500 2.32 7.7
CAR**2417A** 17,200 TDR&TXV 14.50 12.50 17,100 3.58 9,900 2.46 8.2 58CV(A,X)090--- 16 CAR**2417A** 17,200 TDR&TXV 14.50 12.50 17,100 3.56 9,900 2.44 8.2 58MVB060---14 CAR**2417A** 17,200 TDR&TXV 14.50 12.50 17,100 3.56 9,900 2.44 8.2 58UVB060--- 14 CAR**2417A** 17,200 TXV 13.00 10.80 17,200 3.38 10,500 2.32 7.7
CNRF*2418A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
Cooling
Capa-
city
Enhance
Factory
Cooling Heating
Standard
Rating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
25HCR3C
18---30
CNRH*2417A** 17,200 TDR&TXV 14.50 12.50 17,500 3.66 9,900 2.44 8.2 58CV(A,X)070---12 CNRH*2417A** 17,300 TDR&TXV 14.50 12.50 17,400 3.68 10,000 2.46 8.2 58CV(A,X)090--- 16 CNRH*2417A** 17,200 TDR&TXV 14.50 12.50 17,400 3.66 9,900 2.44 8.2 58MVB040---14 CNRH*2417A** 17,200 TDR&TXV 14.50 12.50 17,500 3.68 9,900 2.44 8.2 58MVB060---14 CNRH*2417A** 17,300 TDR&TXV 14.50 12.50 17,400 3.68 10,000 2.46 8.2 58MVB080--- 14 CNRH*2417A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
CNRV*1814A** 17,100 TDR&TXV 14.50 12.00 17,700 3.58 9,900 2.42 8.0 58CV(A ,X)070--- 12 CNRV*1814A** 17,100 TXV 13.00 10.80 17,800 3.46 10,500 2.32 7.7
CNRV*2414A** 17,200 TDR&TXV 14.50 12.50 17,500 3.66 9,900 2.44 8.2 58CV(A ,X)070--- 12 CNRV*2414A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
CNRV*2417A** 17,300 TDR&TXV 14.50 12.50 17,400 3.68 10,000 2.46 8.2 58CV(A,X)090---16 CNRV*2417A** 17,200 TDR&TXV 14.50 12.50 17,400 3.66 9,900 2.44 8.2 58MVB060--- 14 CNRV*2417A** 17,200 TDR&TXV 14.50 12.50 17,400 3.66 9,900 2.44 8.2 58UVB060 ---14 CNRV*2417A** 17,300 TXV 13.20 11.00 17,400 3.46 10,600 2.34 7.7
CSRH*2412A** 17,300 TDR&TXV 14.50 12.50 16,900 3.58 10,000 2.44 8.2 58CV(A,X)070---12 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58CV(A,X)090---16 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58MVB040 ---14 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58MVB060 ---14 CSRH*2412A** 17,400 TDR&TXV 14.50 12.50 16,800 3.58 10,000 2.44 8.2 58MVB080 ---14 CSRH*2412A** 17,400 TXV 13.20 11.00 16,100 3.32 10,600 2.34 7.7
*FA4CN(F,C)024 23,200 TDR&TXV 13.00 10.80 24,000 3.54 14,800 2.38 8.3
FA4CN(F,C)030 23,600 TDR&TXV 13.20 11.00 24,000 3.60 14,800 2.42 8.5
FC4DNF024 23,800 TDR&TXV 14.00 12.00 24,000 3.72 14,400 2.52 8.7 FC4DNF030 24,000 TDR&TXV 14.50 12.00 24,000 3.82 14,400 2.56 8.8 FF1ENE024 23,400 TDR&TXV 13.00 10.80 24,000 3.54 14,900 2.38 8.3 FF1ENE030 23,400 TDR&TXV 13.00 10.80 24,000 3.56 14,900 2.38 8.4
FK4DN(B,F)003 23,800 TDR&TXV 15.00 12.50 23,400 3.80 14,100 2.58 8.8
FK4DNF001 23,600 TDR&TXV 14.50 12.00 23,800 3.70 14,200 2.52 8.6 FK4DNF002 24,000 TDR&TXV 15.00 12.50 23,800 3.82 14,200 2.56 8.8
CAR**2414A** 23,400 TDR&TXV 14.50 11.70 23,800 3.66 14,200 2.50 8.6 58CV(A,X)070--- 12 CAR**2414A** 23,400 TXV 13.00 10.80 24,000 3.60 14,900 2.40 8.5
CAR**2417A** 23,400 TDR&TXV 14.50 11.70 23,600 3.70 14,100 2.54 8.6 58CV(A,X)090--- 16 CAR**2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.68 14,100 2.52 8.6 58MVB060 ---14
24---30
CAR**2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.68 14,100 2.52 8.6 58UVB060 --- 14 CAR**2417A** 23,400 TXV 13.00 10.80 24,000 3.60 14,900 2.40 8.5
CAR**3014A** 23,400 TDR&TXV 14.50 11.70 23,600 3.70 14,200 2.52 8.6 58CV(A,X)070--- 12 CAR**3014A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CAR**3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,100 2.54 8.7 58CV(A,X)090--- 16 CAR**3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58MVB060 ---14 CAR**3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58UVB060 --- 14 CAR**3017A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CNRF*2418A** 23,400 TXV 13.00 10.80 24,000 3.68 15,000 2.42 8.6
CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.72 14,200 2.52 8.7 58CV(A ,X)070--- 12 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.54 8.7 58CV(A ,X)090--- 16 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58CV(A ,X)110--- 20
See notes on page 16
10
Page 11
COMBINATION RATINGS (CONT.)
Unit
S i z e ---
Volt age ,
Series
Indoor Model
CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.52 8.7 58CV(A ,X)135--- 22 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.52 8.7 58CV(A ,X)155--- 22 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB040--- 14 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB060--- 14 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB080--- 14 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB080--- 20 CNRH*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.52 8.7 58MVB100--- 20 CNRH*2417A** 23,400 TDR&TXV 14.00 11.50 23,800 3.72 14,200 2.50 8.6 58MVB120--- 20 CNRH*2417A** 23,400 TXV 13.00 10.80 24,000 3.68 15,000 2.42 8.6
CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58CV(A ,X)070--- 12 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.76 14,100 2.56 8.7 58CV(A ,X)090--- 16 CNRH*3017A** 23,600 TDR&TXV 14.20 11.70 23,600 3.74 14,200 2.54 8.7 58CV(A ,X)110--- 20 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.76 14,100 2.54 8.7 58CV(A ,X)135--- 22 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.76 14,100 2.56 8.8 58CV(A ,X)155--- 22 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58MVB040--- 14 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58MVB060--- 14 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58MVB080--- 14 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58MVB080--- 20 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.76 14,200 2.54 8.7 58MVB100--- 20 CNRH*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58MVB120--- 20 CNRH*3017A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CNRV*2414A** 23,400 TDR&TXV 14.50 11.70 23,800 3.72 14,200 2.52 8.7 58CV(A,X)070---12 CNRV*2414A** 23,400 TXV 13.00 10.80 24,000 3.68 15,000 2.42 8.6
CNRV*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.54 8.7 58CV(A,X)090---16 CNRV*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB060 ---14 CNRV*2417A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58UVB060--- 14 CNRV*2417A** 23,400 TXV 13.00 10.80 24,000 3.68 15,000 2.42 8.6
Cooling
Capa-
city
Factory
Enhance
Standard
Rating
Cooling Heating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
25HCR3C
24---30
30---30
CNRV*3014A** 23,600 TDR&TXV 14.50 11.70 23,600 3.70 14,200 2.52 8.6 58CV(A,X)070---12 CNRV*3014A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CNRV*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.76 14,100 2.56 8.7 58CV(A,X)090---16 CNRV*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58MVB060 ---14 CNRV*3017A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,100 2.54 8.7 58UVB060--- 14 CNRV*3017A** 23,600 TXV 13.00 10.80 24,000 3.58 15,000 2.42 8.5
CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.72 14,200 2.52 8.7 58CV(A,X)070---12 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.54 8.7 58CV(A,X)090---16 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,300 2.52 8.7 58CV(A,X)110---20 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,300 2.52 8.7 58CV(A,X)135---22 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,200 2.54 8.7 58CV(A,X)155---22 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 24,000 3.74 14,300 2.52 8.7 58MVB040 ---14 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB060 ---14 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,300 2.52 8.7 58MVB080 ---14 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.74 14,200 2.52 8.7 58MVB080 ---20 CSRH*2412A** 23,400 TDR&TXV 14.50 11.70 23,800 3.76 14,300 2.54 8.7 58MVB100 ---20 CSRH*2412A** 23,200 TDR&TXV 14.50 11.70 23,800 3.70 14,200 2.52 8.6 58MVB120 ---20 CSRH*2412A** 23,400 TXV 13.20 11.00 24,000 3.70 15,000 2.44 8.6
CSRH*3012A** 23,400 TDR&TXV 14.50 11.70 23,600 3.70 14,200 2.52 8.7 58CV(A,X)070---12 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,100 2.54 8.7 58CV(A,X)090---16 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58CV(A,X)110---20 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58CV(A,X)135---22 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58CV(A,X)155---22 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,200 2.52 8.7 58MVB040 ---14 CSRH*3012A** 23,400 TDR&TXV 14.50 11.70 23,600 3.72 14,200 2.54 8.7 58MVB060 ---14 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,200 2.54 8.7 58MVB080 ---14 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.72 14,200 2.54 8.7 58MVB080 ---20 CSRH*3012A** 23,600 TDR&TXV 14.50 11.70 23,600 3.74 14,200 2.54 8.7 58MVB100 ---20 CSRH*3012A** 23,400 TDR&TXV 14.50 11.70 23,600 3.70 14,200 2.52 8.6 58MVB120 ---20 CSRH*3012A** 23,600 TXV 13.20 11.00 24,000 3.58 15,000 2.44 8.5
*FC4DNF030 28,800 TDR&TXV 13.00 10.80 28,800 3.38 17,300 2.30 8.0 FC4DN(F,B)036 29,000 TDR&TXV 13.00 10.80 28,000 3.30 17,500 2.28 8.0 FK4DN(B,F)003 28,800 TDR&TXV 13.50 11.20 27,800 3.36 17,000 2.32 8.0
FK4DNF001 28,400 TDR&TXV 13.00 10.80 28,800 3.32 17,100 2.26 7.7 FK4DNF002 28,800 TDR&TXV 13.20 11.00 28,800 3.44 17,100 2.30 8.0
CAR**3014A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.26 7.7 58CV(A,X)070--- 12
CAR**3017A** 28,400 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A,X)090--- 16 CAR**3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB060 ---14 CAR**3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58UVB060 --- 14
See notes on page 16
11
Page 12
COMBINATION RATINGS (CONT.)
Unit
S i z e ---
Volt age ,
Series
25HCR3C
Indoor Model
CAR**3614A** 28,600 TDR&TXV 13.00 10.80 28,200 3.30 17,100 2.28 7.7 58CV(A,X)070--- 12
CAR**3617A** 28,600 TDR&TXV 13.20 11.00 28,000 3.34 17,000 2.30 7.7 58CV(A,X)090--- 16 CAR**3617A** 28,600 TDR&TXV 13.20 11.00 28,200 3.32 17,100 2.28 7.7 58MVB060 ---14 CAR**3617A** 28,600 TDR&TXV 13.20 11.00 28,200 3.32 17,100 2.28 7.7 58UVB060 --- 14
CAR**3621A** 28,800 TDR&TXV 13.20 11.00 28,000 3.36 17,000 2.32 7.7 58CV(A,X)110--- 20 CAR**3621A** 28,600 TDR&TXV 13.20 11.00 28,000 3.34 17,100 2.30 7.7 58MVB080 ---20 CAR**3621A** 28,600 TDR&TXV 13.20 11.00 28,000 3.34 17,000 2.30 7.7 58MVB100 ---20 CAR**3621A** 28,600 TDR&TXV 13.20 11.00 28,000 3.34 17,100 2.30 7.7 58UVB080 --- 20 CAR**3621A** 28,600 TDR&TXV 13.20 11.00 28,000 3.34 17,000 2.30 7.7 58UVB100 --- 20
CNRH*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58CV(A ,X)070--- 12 CNRH*3017A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A ,X)090--- 16 CNRH*3017A** 28,600 TDR&TXV 13.20 10.80 28,200 3.34 17,100 2.30 7.7 58CV(A ,X)110--- 20 CNRH*3017A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A ,X)135--- 22 CNRH*3017A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A ,X)155--- 22 CNRH*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB040--- 14 CNRH*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB060--- 14 CNRH*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58MVB080--- 14 CNRH*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58MVB080--- 20 CNRH*3017A** 28,600 TDR&TXV 13.00 10.80 28,200 3.32 17,100 2.28 7.7 58MVB100--- 20
CNRH*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58CV(A ,X)070--- 12 CNRH*3617A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A ,X)090--- 16 CNRH*3617A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,100 2.30 7.7 58CV(A ,X)110--- 20 CNRH*3617A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A ,X)135--- 22 CNRH*3617A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A ,X)155--- 22 CNRH*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB040--- 14 CNRH*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB060--- 14 CNRH*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58MVB080--- 14 CNRH*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58MVB080--- 20 CNRH*3617A** 28,600 TDR&TXV 13.00 10.80 28,200 3.32 17,100 2.28 7.7 58MVB100--- 20 CNRH*3617A** 28,400 TDR&TXV 13.20 11.00 28,200 3.32 17,000 2.28 7.7 58MVB120--- 20
Cooling
Capa-
city
Factory
Enhance
Cooling Heating
Standard
Rating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
CNRV*3014A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,200 2.26 7.7 58CV(A,X)070---12
30---30
CNRV*3017A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,000 2.30 7.7 58CV(A,X)090---16 CNRV*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB060 ---14 CNRV*3017A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58UVB060--- 14
CNRV*3617A** 28,600 TDR&TXV 13.20 10.80 28,200 3.34 17,000 2.30 7.7 58CV(A,X)090---16 CNRV*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58MVB060 ---14 CNRV*3617A** 28,400 TDR&TXV 13.00 10.80 28,400 3.30 17,100 2.28 7.7 58UVB060--- 14
CNRV*3621A** 28,600 TDR&TXV 13.20 11.00 28,200 3.34 17,100 2.30 7.7 58CV(A,X)110---20 CNRV*3621A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58MVB080 ---14 CNRV*3621A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58MVB080 ---20 CNRV*3621A** 28,600 TDR&TXV 13.00 10.80 28,200 3.32 17,100 2.28 7.7 58MVB100 ---20 CNRV*3621A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58UVB080--- 14 CNRV*3621A** 28,400 TDR&TXV 13.00 10.80 28,400 3.32 17,100 2.28 7.7 58UVB080--- 20 CNRV*3621A** 28,600 TDR&TXV 13.00 10.80 28,200 3.32 17,100 2.28 7.7 58UVB100--- 20
CSRH*3012A** 28,600 TDR&TXV 13.00 10.80 28,200 3.30 17,200 2.28 7.7 58CV(A,X)070---12 CSRH*3012A** 28,600 TDR&TXV 13.20 11.00 28,200 3.32 17,100 2.30 7.7 58CV(A,X)090---16 CSRH*3012A** 28,800 TDR&TXV 13.20 11.00 28,200 3.34 17,100 2.30 7.7 58CV(A,X)110---20 CSRH*3012A** 28,800 TDR&TXV 13.20 11.00 28,200 3.34 17,100 2.30 7.7 58CV(A,X)135---22 CSRH*3012A** 28,800 TDR&TXV 13.20 11.00 28,200 3.34 17,100 2.30 7.7 58CV(A,X)155---22 CSRH*3012A** 28,600 TDR&TXV 13.00 10.80 28,200 3.30 17,200 2.28 7.7 58MVB040 ---14 CSRH*3012A** 28,600 TDR&TXV 13.00 10.80 28,200 3.30 17,100 2.28 7.7 58MVB060 ---14 CSRH*3012A** 28,600 TDR&TXV 13.00 10.80 28,200 3.30 17,200 2.28 7.7 58MVB080 ---14 CSRH*3012A** 28,600 TDR&TXV 13.00 10.80 28,200 3.32 17,100 2.28 7.7 58MVB080 ---20 CSRH*3012A** 28,600 TDR&TXV 13.20 11.00 28,200 3.32 17,100 2.28 7.7 58MVB100 ---20 CSRH*3012A** 28,600 TDR&TXV 13.20 11.00 28,200 3.32 17,100 2.28 7.7 58MVB120 ---20
CSRH*3612A** 29,200 TDR&TXV 13.50 11.00 27,600 3.36 17,200 2.32 8.0 58CV(A,X)070---12 CSRH*3612A** 29,200 TDR&TXV 13.50 11.20 27,600 3.38 17,100 2.34 8.0 58CV(A,X)090---16 CSRH*3612A** 29,400 TDR&TXV 13.50 11.20 27,400 3.38 17,100 2.34 8.0 58CV(A,X)110---20 CSRH*3612A** 29,400 TDR&TXV 13.50 11.20 27,400 3.40 17,100 2.34 8.0 58CV(A,X)135---22 CSRH*3612A** 29,400 TDR&TXV 13.50 11.20 27,400 3.40 17,100 2.34 8.0 58CV(A,X)155---22 CSRH*3612A** 29,200 TDR&TXV 13.20 11.00 27,600 3.36 17,200 2.32 8.0 58MVB040 ---14 CSRH*3612A** 29,200 TDR&TXV 13.20 11.00 27,600 3.36 17,100 2.32 8.0 58MVB060 ---14 CSRH*3612A** 29,200 TDR&TXV 13.20 11.00 27,600 3.36 17,200 2.32 8.0 58MVB080 ---14 CSRH*3612A** 29,200 TDR&TXV 13.20 11.00 27,600 3.36 17,200 2.32 8.0 58MVB080 ---20 CSRH*3612A** 29,200 TDR&TXV 13.50 11.20 27,600 3.38 17,100 2.32 8.0 58MVB100 ---20 CSRH*3612A** 29,200 TDR&TXV 13.50 11.20 27,600 3.36 17,100 2.32 8.0 58MVB120 ---20
See notes on page 16
12
Page 13
COMBINATION RATINGS (CONT.)
Unit
S i z e ---
Volt age ,
Series
Indoor Model
*FC4DN(F,B)036 34,600 TDR&TXV 13.00 10.80 35,000 3.36 21,200 2.46 8.0
FC4DN(F,B)042 35,400 TDR&TXV 13.20 11.00 32,200 3.32 21,400 2.52 8.4
FK4DNF002 34,000 TDR&TXV 13.00 10.80 36,400 3.46 21,000 2.44 8.2 FK4DNF003 34,200 TDR&TXV 13.50 11.20 35,000 3.38 20,800 2.48 8.3
CAR**3614A** 32,800 TDR&TXV 13.00 10.80 34,400 3.32 21,000 2.42 8.1 58CV(A,X)070--- 12
CAR**3617A** 34,000 TDR&TXV 13.20 11.00 35,400 3.36 20,800 2.46 8.2 58CV(A,X)090--- 16 CAR**3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58MVB060 ---14 CAR**3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58UVB060 --- 14
CAR**3621A** 34,000 TDR&TXV 13.20 11.00 35,200 3.38 20,800 2.46 8.3 58CV(A,X)110--- 20 CAR**3621A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB080 ---14 CAR**3621A** 34,000 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58MVB080 ---20 CAR**3621A** 34,000 TDR&TXV 13.20 11.00 35,400 3.36 20,800 2.44 8.2 58MVB100 ---20 CAR**3621A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58UVB080 --- 14 CAR**3621A** 34,000 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58UVB080 --- 20 CAR**3621A** 34,000 TDR&TXV 13.20 11.00 35,400 3.36 20,800 2.44 8.2 58UVB100 --- 20
CAR**4221A** 34,400 TDR&TXV 13.20 11.00 34,800 3.40 21,000 2.48 8.3 58CV(A,X)110--- 20 CAR**4221A** 34,000 TDR&TXV 13.00 10.80 35,000 3.36 21,000 2.44 8.2 58MVB080 ---14 CAR**4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.38 21,000 2.46 8.3 58MVB080 ---20 CAR**4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.38 21,000 2.46 8.3 58MVB100 ---20 CAR**4221A** 34,000 TDR&TXV 13.00 10.80 35,000 3.36 21,000 2.44 8.2 58UVB080 --- 14 CAR**4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.38 21,000 2.46 8.3 58UVB080 --- 20 CAR**4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.38 21,000 2.46 8.3 58UVB100 --- 20
CAR**4224A** 34,400 TDR&TXV 13.50 11.20 34,800 3.42 20,800 2.50 8.4 58CV(A,X)135--- 22 CAR**4224A** 34,400 TDR&TXV 13.50 11.20 34,600 3.44 20,800 2.50 8.4 58CV(A,X)155--- 22 CAR**4224A** 34,200 TDR&TXV 13.00 10.80 35,000 3.36 21,000 2.44 8.3 58MVB040 ---14 CAR**4224A** 34,200 TDR&TXV 13.20 11.00 34,800 3.40 20,800 2.48 8.3 58MVB120 ---20 CAR**4224A** 34,200 TDR&TXV 13.20 11.00 34,800 3.40 20,800 2.48 8.3 58UVB120 --- 20
Cooling
Capa-
city
Factory
Enhance
Standard
Rating
Cooling Heating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
25HCR3C
36---30
CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,600 3.32 21,000 2.42 8.1 58CV(A ,X)070--- 12 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58CV(A ,X)090--- 16 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58CV(A ,X)110--- 20 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.36 20,800 2.44 8.2 58CV(A ,X)135--- 22 CNRH*3617A** 34,000 TDR&TXV 13.20 11.00 35,400 3.38 20,800 2.46 8.2 58CV(A ,X)155--- 22 CNRH*3617A** 33,600 TDR&TXV 13.00 10.80 35,400 3.30 21,000 2.40 8.1 58MVB040--- 14 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB060--- 14 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.32 21,000 2.42 8.2 58MVB080--- 20 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB100--- 20 CNRH*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB120--- 20
CNRH*4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.40 21,000 2.46 8.3 58CV(A ,X)070--- 12 CNRH*4221A** 34,400 TDR&TXV 13.50 11.20 34,800 3.44 20,800 2.50 8.4 58CV(A ,X)090--- 16 CNRH*4221A** 34,600 TDR&TXV 13.50 11.20 34,800 3.44 20,800 2.50 8.4 58CV(A ,X)110--- 20 CNRH*4221A** 34,600 TDR&TXV 13.50 11.20 34,600 3.46 20,800 2.52 8.5 58CV(A ,X)135--- 22 CNRH*4221A** 34,600 TDR&TXV 13.50 11.20 34,600 3.48 20,600 2.52 8.5 58CV(A ,X)155--- 22 CNRH*4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.40 21,000 2.48 8.3 58MVB040--- 14 CNRH*4221A** 34,400 TDR&TXV 13.50 11.20 34,800 3.42 20,800 2.48 8.4 58MVB060--- 14 CNRH*4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.40 21,000 2.46 8.3 58MVB080--- 14 CNRH*4221A** 34,400 TDR&TXV 13.20 11.00 34,800 3.40 21,000 2.48 8.3 58MVB080--- 20 CNRH*4221A** 34,400 TDR&TXV 13.50 11.20 34,800 3.42 20,800 2.48 8.4 58MVB100--- 20 CNRH*4221A** 34,400 TDR&TXV 13.50 11.20 34,800 3.44 20,800 2.50 8.4 58MVB120--- 20
CNRV*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58CV(A,X)090---16 CNRV*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB060 ---14 CNRV*3617A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58UVB060--- 14
CNRV*3621A** 34,000 TDR&TXV 13.00 10.80 35,400 3.36 21,000 2.44 8.2 58CV(A,X)110---20 CNRV*3621A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB080 ---20 CNRV*3621A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58MVB100 ---20 CNRV*3621A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58UVB080--- 20 CNRV*3621A** 33,800 TDR&TXV 13.00 10.80 35,400 3.34 21,000 2.42 8.2 58UVB100--- 20
CNRV*4221A** 34,600 TDR&TXV 13.50 11.20 34,800 3.44 20,800 2.50 8.4 58CV(A,X)110---20 CNRV*4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.40 21,000 2.46 8.3 58MVB080 ---14 CNRV*4221A** 34,400 TDR&TXV 13.20 11.00 34,800 3.40 21,000 2.48 8.3 58MVB080 ---20 CNRV*4221A** 34,400 TDR&TXV 13.50 11.20 34,800 3.42 20,800 2.48 8.4 58MVB100 ---20 CNRV*4221A** 34,200 TDR&TXV 13.20 11.00 35,000 3.40 21,000 2.46 8.3 58UVB080--- 14 CNRV*4221A** 34,400 TDR&TXV 13.20 11.00 34,800 3.40 21,000 2.48 8.3 58UVB080--- 20 CNRV*4221A** 34,400 TDR&TXV 13.50 11.20 34,800 3.42 20,800 2.48 8.4 58UVB100--- 20
CSRH*3612A** 33,600 TDR&TXV 13.20 11.00 34,400 3.38 21,200 2.46 8.3 58CV(A,X)070---12 CSRH*3612A** 34,000 TDR&TXV 13.50 11.20 34,400 3.42 21,000 2.50 8.4 58CV(A,X)090---16
See notes on page 16
13
Page 14
COMBINATION RATINGS (CONT.)
Unit
S i z e ---
Volt age ,
Series
Indoor Model
CSRH*3612A** 34,000 TDR&TXV 13.50 11.20 34,200 3.42 21,000 2.50 8.4 58CV(A,X)110---20 CSRH*3612A** 34,000 TDR&TXV 13.50 11.20 34,200 3.44 21,000 2.50 8.4 58CV(A,X)135---22 CSRH*3612A** 34,000 TDR&TXV 13.50 11.20 34,200 3.46 21,000 2.52 8.5 58CV(A,X)155---22 CSRH*3612A** 33,600 TDR&TXV 13.20 11.00 34,600 3.38 21,200 2.46 8.3 58MVB040 ---14 CSRH*3612A** 33,800 TDR&TXV 13.20 11.00 34,400 3.40 21,000 2.48 8.4 58MVB060 ---14 CSRH*3612A** 33,600 TDR&TXV 13.00 10.80 34,600 3.36 21,200 2.46 8.3 58MVB080 ---14 CSRH*3612A** 33,800 TDR&TXV 13.20 11.00 34,400 3.40 21,000 2.48 8.4 58MVB080 ---20 CSRH*3612A** 33,800 TDR&TXV 13.20 11.00 34,400 3.40 21,000 2.48 8.4 58MVB100 ---20 CSRH*3612A** 33,800 TDR&TXV 13.20 11.00 34,400 3.42 21,000 2.48 8.4 58MVB120 ---20
Cooling
Capa-
city
Factory
Enhance
Standard
Rating
Cooling Heating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
36---30
25HCR3C
CSRH*4212A** 34,200 TDR&TXV 13.20 11.00 33,800 3.38 21,200 2.48 8.4 58CV(A,X)070---12 CSRH*4212A** 34,200 TDR&TXV 13.50 11.20 33,800 3.42 21,000 2.52 8.5 58CV(A,X)090---16 CSRH*4212A** 34,400 TDR&TXV 13.50 11.20 33,600 3.42 21,000 2.52 8.5 58CV(A,X)110---20 CSRH*4212A** 34,400 TDR&TXV 13.50 11.20 33,600 3.44 21,000 2.52 8.5 58CV(A,X)135---22 CSRH*4212A** 34,400 TDR&TXV 13.50 11.50 33,600 3.46 21,000 2.54 8.5 58CV(A,X)155---22 CSRH*4212A** 34,000 TDR&TXV 13.20 11.00 34,000 3.38 21,200 2.48 8.4 58MVB040 ---14 CSRH*4212A** 34,200 TDR&TXV 13.50 11.20 33,800 3.42 21,000 2.50 8.4 58MVB060 ---14 CSRH*4212A** 34,000 TDR&TXV 13.20 11.00 34,000 3.38 21,200 2.46 8.3 58MVB080 ---14 CSRH*4212A** 34,200 TDR&TXV 13.50 11.20 33,800 3.40 21,000 2.50 8.4 58MVB080 ---20 CSRH*4212A** 34,200 TDR&TXV 13.50 11.20 33,800 3.42 21,000 2.50 8.4 58MVB100 ---20 CSRH*4212A** 34,200 TDR&TXV 13.50 11.20 33,800 3.42 21,000 2.50 8.4 58MVB120 ---20
*FC4DN(F,B)042 41,000 TDR&TXV 13.00 11.00 40,500 3.56 24,600 2.42 8.0
FC4DN(F,B)048 42,000 TDR&TXV 13.50 11.20 39,500 3.68 24,600 2.48 8.2 FK4DN(B,F)003 40,000 TDR&TXV 13.50 11.20 39,500 3.38 23,800 2.40 7.7 FK4DN(B,F)005 41,500 TDR&TXV 14.00 12.00 39,000 3.62 24,000 2.50 8.0
FK4DNB006 42,000 TDR&TXV 14.50 12.00 37,200 3.60 24,000 2.54 8.2
CAR**4221A** 40,000 TDR&TXV 13.50 11.20 40,000 3.42 24,000 2.40 7.7 58CV(A,X)110--- 20 CAR**4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.36 24,200 2.36 7.7 58MVB080 ---14 CAR**4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.38 24,200 2.38 7.7 58MVB080 ---20 CAR**4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.40 24,000 2.40 7.7 58MVB100 ---20 CAR**4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.36 24,200 2.36 7.7 58UVB080 --- 14 CAR**4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.38 24,200 2.38 7.7 58UVB080 --- 20 CAR**4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.40 24,000 2.40 7.7 58UVB100 --- 20
CAR**4224A** 40,000 TDR&TXV 13.50 11.20 39,500 3.46 23,800 2.44 7.7 58CV(A,X)135--- 22 CAR**4224A** 40,000 TDR&TXV 13.50 11.20 39,500 3.46 23,800 2.44 7.7 58CV(A,X)155--- 22 CAR**4224A** 39,500 TDR&TXV 13.20 11.00 40,000 3.36 24,200 2.38 7.7 58MVB040 ---14 CAR**4224A** 39,500 TDR&TXV 13.50 11.00 40,000 3.40 24,000 2.40 7.7 58MVB120 ---20 CAR**4224A** 39,500 TDR&TXV 13.50 11.00 40,000 3.40 24,000 2.40 7.7 58UVB120 --- 20
CAR**4817A** 41,000 TDR&TXV 13.50 11.20 39,500 3.58 24,200 2.44 8.0 58CV(A,X)090--- 16 CAR**4817A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.42 7.7 58MVB060 ---14 CAR**4817A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.42 7.7 58UVB060 --- 14
CAR**4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.58 24,000 2.44 8.0 58CV(A,X)110--- 20 CAR**4821A** 40,000 TDR&TXV 13.20 11.20 40,000 3.50 24,200 2.40 7.7 58MVB080 ---14 CAR**4821A** 40,500 TDR&TXV 13.20 11.00 40,000 3.54 24,200 2.42 7.7 58MVB080 ---20
42---30
CAR**4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.44 7.7 58MVB100 ---20 CAR**4821A** 40,000 TDR&TXV 13.20 11.20 40,000 3.50 24,200 2.40 7.7 58UVB080 --- 14 CAR**4821A** 40,500 TDR&TXV 13.20 11.00 40,000 3.54 24,200 2.42 7.7 58UVB080 --- 20 CAR**4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.44 7.7 58UVB100 --- 20
CAR**4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.62 24,000 2.46 8.0 58CV(A,X)135--- 22 CAR**4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.62 24,000 2.46 8.0 58CV(A,X)155--- 22 CAR**4824A** 40,000 TDR&TXV 13.20 11.00 40,000 3.52 24,200 2.40 7.7 58MVB040 ---14 CAR**4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,000 2.44 7.7 58MVB120 ---20 CAR**4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,000 2.44 7.7 58UVB120 --- 20
CNRH*4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.36 24,200 2.36 7.7 58CV(A ,X)070--- 12 CNRH*4221A** 40,000 TDR&TXV 13.20 11.00 40,000 3.42 24,000 2.40 7.7 58CV(A ,X)090--- 16 CNRH*4221A** 40,000 TDR&TXV 13.20 11.00 40,000 3.42 24,000 2.40 7.7 58CV(A ,X)110--- 20 CNRH*4221A** 40,000 TDR&TXV 13.50 11.20 40,000 3.44 24,000 2.42 7.7 58CV(A ,X)135--- 22 CNRH*4221A** 40,000 TDR&TXV 13.50 11.20 40,000 3.44 24,000 2.42 7.7 58CV(A ,X)155--- 22 CNRH*4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.36 24,200 2.36 7.7 58MVB040--- 14 CNRH*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.38 24,200 2.38 7.7 58MVB060--- 14 CNRH*4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.34 24,200 2.36 7.7 58MVB080--- 14 CNRH*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.38 24,200 2.38 7.7 58MVB080--- 20 CNRH*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.40 24,200 2.38 7.7 58MVB100--- 20 CNRH*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.40 24,000 2.38 7.7 58MVB120--- 20
CNRH*4821A** 40,500 TDR&TXV 13.20 11.00 40,500 3.52 24,200 2.40 7.7 58CV(A ,X)070--- 12 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,000 2.44 7.7 58CV(A ,X)090--- 16 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.58 24,000 2.46 8.0 58CV(A ,X)110--- 20 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.62 24,000 2.48 8.0 58CV(A ,X)135--- 22 CNRH*4821A** 40,500 TDR&TXV 14.00 11.50 40,000 3.60 24,000 2.48 8.0 58CV(A ,X)155--- 22
See notes on page 16
14
Page 15
COMBINATION RATINGS (CONT.)
Unit
S i z e ---
Volt age ,
Series
42---30
Indoor Model
CNRH*4821A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.42 7.7 58MVB040--- 14 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.54 24,200 2.42 7.7 58MVB060--- 14 CNRH*4821A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.40 7.7 58MVB080--- 14 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,500 3.54 24,200 2.42 7.7 58MVB080--- 20 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.44 7.7 58MVB100--- 20 CNRH*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,000 2.44 7.7 58MVB120--- 20
CNRV*4221A** 40,000 TDR&TXV 13.20 11.00 40,000 3.42 24,000 2.40 7.7 58CV(A,X)110---20 CNRV*4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.34 24,200 2.36 7.7 58MVB080 ---14 CNRV*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.38 24,200 2.38 7.7 58MVB080 ---20 CNRV*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.40 24,200 2.38 7.7 58MVB100 ---20 CNRV*4221A** 39,500 TDR&TXV 13.00 10.80 40,000 3.34 24,200 2.36 7.7 58UVB080--- 14 CNRV*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.38 24,200 2.38 7.7 58UVB080--- 20 CNRV*4221A** 39,500 TDR&TXV 13.20 11.00 40,000 3.40 24,200 2.38 7.7 58UVB100--- 20
CNRV*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.58 24,000 2.46 8.0 58CV(A,X)110---20 CNRV*4821A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.40 7.7 58MVB080 ---14 CNRV*4821A** 40,500 TDR&TXV 13.50 11.20 40,500 3.54 24,200 2.42 7.7 58MVB080 ---20 CNRV*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.44 7.7 58MVB100 ---20 CNRV*4821A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.40 7.7 58UVB080--- 14 CNRV*4821A** 40,500 TDR&TXV 13.50 11.20 40,500 3.54 24,200 2.42 7.7 58UVB080--- 20 CNRV*4821A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.44 7.7 58UVB100--- 20
CNRV*4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.62 24,000 2.48 8.0 58CV(A,X)135---22 CNRV*4824A** 40,500 TDR&TXV 14.00 11.50 40,000 3.60 24,000 2.48 8.0 58CV(A,X)155---22 CNRV*4824A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.42 7.7 58MVB040 ---14 CNRV*4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,000 2.44 7.7 58MVB120 ---20 CNRV*4824A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,000 2.44 7.7 58UVB120--- 20
Cooling
Capa-
city
Factory
Enhance
Standard
Rating
Cooling Heating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
25HCR3C
48---30
CSRH*4212A** 40,500 TDR&TXV 13.00 11.00 40,500 3.50 24,400 2.40 7.7 58CV(A,X)070---12 CSRH*4212A** 40,500 TDR&TXV 13.50 11.20 40,000 3.56 24,200 2.44 7.7 58CV(A,X)090---16 CSRH*4212A** 41,000 TDR&TXV 13.50 11.20 40,500 3.58 24,200 2.44 8.0 58CV(A,X)110---20 CSRH*4212A** 41,000 TDR&TXV 13.50 11.20 40,000 3.60 24,000 2.46 8.0 58CV(A,X)135---22 CSRH*4212A** 41,000 TDR&TXV 13.50 11.20 40,000 3.60 24,000 2.46 8.0 58CV(A,X)155---22 CSRH*4212A** 40,500 TDR&TXV 13.20 11.00 40,500 3.50 24,200 2.40 7.7 58MVB040 ---14 CSRH*4212A** 40,500 TDR&TXV 13.50 11.20 40,500 3.54 24,200 2.42 7.7 58MVB060 ---14 CSRH*4212A** 40,500 TDR&TXV 13.20 11.00 40,500 3.48 24,400 2.40 7.7 58MVB080 ---14 CSRH*4212A** 40,500 TDR&TXV 13.50 11.20 40,500 3.54 24,200 2.42 7.7 58MVB080 ---20 CSRH*4212A** 40,500 TDR&TXV 13.50 11.20 40,500 3.54 24,200 2.44 7.7 58MVB100 ---20 CSRH*4212A** 40,500 TDR&TXV 13.50 11.20 40,000 3.54 24,200 2.44 7.7 58MVB120 ---20
CSRH*4812A** 40,500 TDR&TXV 13.20 11.00 40,500 3.54 24,400 2.40 7.7 58CV(A,X)070---12 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,000 3.60 24,200 2.46 8.0 58CV(A,X)090---16 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,500 3.60 24,200 2.46 8.0 58CV(A,X)110---20 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,000 3.64 24,000 2.48 8.0 58CV(A,X)135---22 CSRH*4812A** 41,000 TDR&TXV 14.00 11.50 40,000 3.64 24,000 2.48 8.0 58CV(A,X)155---22 CSRH*4812A** 40,500 TDR&TXV 13.20 11.00 40,500 3.54 24,400 2.42 7.7 58MVB040 ---14 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,500 3.56 24,200 2.44 7.7 58MVB060 ---14 CSRH*4812A** 40,500 TDR&TXV 13.20 11.00 40,500 3.52 24,400 2.40 7.7 58MVB080 ---14 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,500 3.56 24,200 2.42 7.7 58MVB080 ---20 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,500 3.58 24,200 2.44 8.0 58MVB100 ---20 CSRH*4812A** 41,000 TDR&TXV 13.50 11.20 40,000 3.58 24,200 2.44 8.0 58MVB120 ---20 CSRH*4812A** 41,500 TXV 10.80 41,000 3.54 25,000 2.38 7.7
*FC4DN(F,B)048 47,000 TDR&TXV 1’3.00 10.80 47,000 3.46 30,200 2.60 8.5
FK4DNB006 47,500 TDR&TXV 14.00 11.50 46,000 3.54 29,600 2.66 8.6 FK4DNF005 46,500 TDR&TXV 13.50 11.20 46,000 3.40 29,600 2.60 8.4
CAR**4817A** 44,000 TDR&TXV 13.20 11.00 45,000 3.36 30,000 2.54 8.3 58CV(A,X)090--- 16
CAR**4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.34 29,800 2.54 8.2 58CV(A,X)110--- 20 CAR**4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.30 29,800 2.50 8.1 58MVB080 ---20 CAR**4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.32 29,800 2.52 8.2 58MVB100 ---20 CAR**4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.30 29,800 2.50 8.1 58UVB080 --- 20 CAR**4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.32 29,800 2.52 8.2 58UVB100 --- 20
CAR**4824A** 45,500 TDR&TXV 13.50 11.20 46,000 3.36 29,600 2.56 8.3 58CV(A,X)135--- 22 CAR**4824A** 45,500 TDR&TXV 13.50 11.20 45,500 3.38 29,400 2.58 8.3 58CV(A,X)155--- 22 CAR**4824A** 45,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.52 8.2 58MVB120 ---20 CAR**4824A** 45,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.52 8.2 58UVB120 --- 20
CAR**6021A** 46,500 TDR&TXV 13.50 11.20 46,000 3.36 29,600 2.58 8.3 58CV(A,X)110--- 20 CAR**6021A** 46,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.54 8.2 58MVB080 ---20 CAR**6021A** 46,500 TDR&TXV 13.50 11.20 46,000 3.34 29,800 2.56 8.2 58MVB100 ---20 CAR**6021A** 46,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.54 8.2 58UVB080 --- 20 CAR**6021A** 46,500 TDR&TXV 13.50 11.20 46,000 3.34 29,800 2.56 8.2 58UVB100 --- 20
See notes on page 16
15
Page 16
COMBINATION RATINGS (CONT.)
Unit
S i z e ---
Volt age ,
Series
Indoor Model
CAR**6024A** 46,500 TDR&TXV 13.50 11.20 46,000 3.38 29,600 2.58 8.3 58CV(A,X)135--- 22 CAR**6024A** 46,500 TDR&TXV 13.50 11.50 46,000 3.40 29,600 2.60 8.4 58CV(A,X)155--- 22 CAR**6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.54 8.2 58MVB120 ---20 CAR**6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.54 8.2 58UVB120 --- 20
CNRH*4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.54 8.2 58CV(A ,X)090--- 16 CNRH*4821A** 45,500 TDR&TXV 13.20 11.00 46,000 3.34 29,600 2.54 8.2 58CV(A ,X)110--- 20 CNRH*4821A** 45,500 TDR&TXV 13.50 11.20 45,500 3.36 29,600 2.56 8.3 58CV(A ,X)135--- 22 CNRH*4821A** 45,500 TDR&TXV 13.50 11.20 45,500 3.38 29,400 2.58 8.3 58CV(A ,X)155--- 22 CNRH*4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.30 29,800 2.52 8.1 58MVB080--- 20 CNRH*4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.52 8.2 58MVB100--- 20 CNRH*4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.30 29,800 2.52 8.2 58MVB120--- 20
CNRH*6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.56 8.2 58CV(A ,X)090--- 16 CNRH*6024A** 46,500 TDR&TXV 13.50 11.20 46,000 3.34 29,600 2.56 8.2 58CV(A ,X)110--- 20 CNRH*6024A** 46,500 TDR&TXV 13.50 11.20 46,000 3.36 29,600 2.58 8.3 58CV(A ,X)135--- 22 CNRH*6024A** 46,500 TDR&TXV 13.50 11.20 45,500 3.40 29,400 2.60 8.3 58CV(A ,X)155--- 22 CNRH*6024A** 46,000 TDR&TXV 13.20 11.00 46,000 3.30 29,800 2.54 8.2 58MVB080--- 20 CNRH*6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.56 8.2 58MVB100--- 20 CNRH*6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.56 8.2 58MVB120--- 20
Cooling
Capa-
city
Factory
Enhance
Standard
Rating
Cooling Heating
SEER
TDR
EER
ARI Standard Ratings
High Temp Low Temp
E
CapacityECOPHCapacityHCOP
HSPF
Furnace Model
25HCR3C
48---30
CNRV*4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.34 29,600 2.54 8.2 58CV(A,X)110---20 CNRV*4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.30 29,800 2.52 8.1 58MVB080 ---20 CNRV*4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.52 8.2 58MVB100 ---20 CNRV*4821A** 45,000 TDR&TXV 13.00 10.80 46,000 3.30 29,800 2.52 8.1 58UVB080--- 20 CNRV*4821A** 45,000 TDR&TXV 13.20 11.00 46,000 3.32 29,800 2.52 8.2 58UVB100--- 20
CNRV*4824A** 45,500 TDR&TXV 13.50 11.20 45,000 3.36 29,600 2.56 8.3 58CV(A,X)135---22 CNRV*4824A** 45,500 TDR&TXV 13.50 11.20 45,500 3.38 29,400 2.58 8.3 58CV(A,X)155---22 CNRV*4824A** 45,000 TDR&TXV 13.20 11.00 46,000 3.30 29,800 2.52 8.2 58MVB120 ---20 CNRV*4824A** 45,000 TDR&TXV 13.20 11.00 46,000 3.30 29,800 2.52 8.2 58UVB120--- 20
CNRV*6024A** 46,500 TDR&TXV 13.50 11.20 46,000 3.36 29,600 2.58 8.3 58CV(A,X)135---22 CNRV*6024A** 46,500 TDR&TXV 13.50 11.20 45,500 3.40 29,400 2.60 8.3 58CV(A,X)155---22 CNRV*6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.56 8.2 58MVB120 ---20 CNRV*6024A** 46,000 TDR&TXV 13.50 11.20 46,000 3.32 29,800 2.56 8.2 58UVB120--- 20
CSRH*4812A** 45,000 TDR&TXV 13.20 11.00 46,000 3.34 29,800 2.54 8.2 58CV(A,X)090---16 CSRH*4812A** 45,000 TDR&TXV 13.20 11.00 46,000 3.36 29,800 2.54 8.3 58CV(A,X)110---20 CSRH*4812A** 45,500 TDR&TXV 13.50 11.20 46,000 3.38 29,800 2.56 8.3 58CV(A,X)135---22 CSRH*4812A** 45,500 TDR&TXV 13.50 11.20 45,500 3.40 29,600 2.58 8.4 58CV(A,X)155---22 CSRH*4812A** 45,000 TDR&TXV 13.00 10.80 46,000 3.32 30,000 2.52 8.2 58MVB080 ---20 CSRH*4812A** 45,000 TDR&TXV 13.20 11.00 46,000 3.34 30,000 2.54 8.2 58MVB100 ---20 CSRH*4812A** 45,000 TDR&TXV 13.20 11.00 46,000 3.34 29,800 2.54 8.2 58MVB120 ---20
CSRH*6012A** 46,000 TDR&TXV 13.50 11.20 46,000 3.38 29,800 2.58 8.3 58CV(A,X)090---16 CSRH*6012A** 46,000 TDR&TXV 13.50 11.20 46,000 3.40 29,800 2.58 8.4 58CV(A,X)110---20 CSRH*6012A** 46,500 TDR&TXV 13.50 11.20 46,000 3.44 29,600 2.60 8.4 58CV(A,X)135---22 CSRH*6012A** 46,500 TDR&TXV 14.00 11.50 46,000 3.46 29,600 2.62 8.5 58CV(A,X)155---22 CSRH*6012A** 46,000 TDR&TXV 13.50 11.20 46,000 3.36 30,000 2.56 8.3 58MVB080 ---20 CSRH*6012A** 46,000 TDR&TXV 13.50 11.20 46,000 3.38 29,800 2.56 8.3 58MVB100 ---20 CSRH*6012A** 46,000 TDR&TXV 13.50 11.20 46,000 3.38 29,800 2.56 8.3 58MVB120 ---20 CSRH*6012A** 46,000 TXV 10.80 46,000 3.42 30,800 2.54 8.4
*FC4DN(F,B)060 59,000 TDR&TXV 13.00 10.80 60,000 3.50 37,200 2.46 8.1
FK4DNB006 58,500 TDR&TXV 13.20 11.00 59,500 3.52 36,400 2.48 8.1
CAR**6024A** 58,000 TDR&TXV 13.00 10.80 59,500 3.40 36,400 2.44 7.9 58CV(A,X)155--- 22
60---30
CNRH*6024A** 57,500 TDR&TXV 13.00 10.80 59,000 3.36 36,200 2.44 7.8 58CV(A ,X)155--- 22
CNRV*6024A** 57,500 TDR&TXV 13.00 10.80 59,000 3.36 36,200 2.44 7.8 58CV(A,X)155---22
CSRH*6012A** 57,500 TDR&TXV 13.00 10.80 59,500 3.40 36,400 2.44 7.9 58CV(A,X)135---22 CSRH*6012A** 58,000 TDR&TXV 13.20 11.00 59,500 3.42 36,400 2.46 7.9 58CV(A,X)155---22
* Tested Combinations # Ratings are net values reflecting the effects of circulating fan heat. Ratings are based on:
Cooling Standard: 80_F(27_C) db 67_F(19_C) wb indoor entering air temperature and 95_F(35_C) db air entering outdoor unit. High---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 47_F(8_C) db 43˚F(6_C) wb air entering outdoor unit. Low---Temp Heating Standard: 70_F(21_C) db indoor entering air temperature and 17_F(±9_C) db 15˚F(±10_C) wb air entering outdoor unit.
SEER — Seasonal Energy Efficiency Ratio COP — Coefficient of Performance TDR — T i m e --- D e l ay R e l ay HSPF — Heating Seasonal Performance Factor EER — Energy Efficiency Ratio
16
Page 17
Tot a l Sy s -
Capacity MBtuh
Tot a l Sy s -
Capacity MBtuh
tem KW
tem KW
tem KW
Tot a l Sy s -
Capacity MBtuh
tem KW
Tot a l Sy s -
Capacity Power Furna ce M odel
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
Cooling Indoor
Model
CAR**2417A** 1.01 0.87 58UVB060--- 14
CSRH*2412A** 1.02 0.88 58MVB060 ---14
CSRH*2412A** 1.02 0.88 58MVB080 ---14
CNRV*2417A** 1.01 0.87 58UVB060--- 14
CNRH*2417A** 1.02 0.88 58MVB080--- 14
See notes on page 23
25HCR318C Outdoor Section With FA4CN(F,C)018 Indoor Section
tem KW
Tot a l Sy s -
25HCR3C
DETAILED COOLING CAPACITIES
EVAPORATOR AIR
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Capacity MBtuh
Tot a l Sy s -
Capacity MBtuh
tem KW
Tot a l Sens Tot a l Sens To ta l Sens Tot al Sens Tot al Sens Tot al Sens
CFM EWB
Capacity Power Furna ce M odel
72 19.93 9.85 1.25 19.22 9.59 1.40 18.48 9.32 1.56 17.70 9.03 1.74 16.88 8.74 1.93 16.02 8.43 2.15
67 18.11 12.26 1.24 17.44 11.99 1.38 16.74 11.70 1.54 16.01 11.41 1.72 15.24 11.10 1.92 14.43 10.78 2.13
63 16.80 11.84 1.23 16.16 11.56 1.37 15.50 11.26 1.53 14.80 10.96 1.71 14.07 10.65 1.90 13.30 10.32 2.12
62 16.50 14.62 1.22 15.89 14.32 1.37 15.25 14.00 1.53 14.59 13.65 1.71 13.89 13.88 1.90 13.25 13.25 2.12
57 16.02 16.02 1.22 15.52 15.52 1.37 15.00 15.00 1.53 14.45 14.45 1.71 13.87 13.87 1.90 13.25 13.25 2.12
72 20.27 10.30 1.28 19.54 10.03 1.43 18.77 9.76 1.59 17.96 9.47 1.77 17.12 9.17 1.97 16.23 8.86 2.18
67 18.42 13.01 1.27 17.73 12.73 1.41 17.00 12.44 1.57 16.24 12.14 1.75 15.45 11.82 1.95 14.62 11.49 2.16
63 17.09 12.54 1.26 16.43 12.25 1.40 15.74 11.95 1.56 15.02 11.64 1.74 14.27 11.32 1.94 13.48 10.98 2.15
62 16.84 15.58 1.26 16.22 15.24 1.40 15.56 15.56 1.56 14.95 14.95 1.74 14.34 14.34 1.94 13.70 13.70 2.15
57 16.61 16.61 1.25 16.09 16.09 1.40 15.54 15.54 1.56 14.96 14.96 1.74 14.35 14.35 1.94 13.70 13.70 2.15
72 20.52 10.72 1.31 19.77 10.45 1.46 18.98 10.18 1.62 18.15 9.89 1.80 17.28 9.59 2.00 16.37 9.27 2.21
67 18.64 13.73 1.30 17.93 13.44 1.44 17.19 13.14 1.61 16.42 12.83 1.78 15.60 12.51 1.98 14.76 12.17 2.20
63 17.31 13.20 1.29 16.63 12.91 1.43 15.92 12.60 1.59 15.19 12.28 1.77 14.42 11.95 1.97 13.61 11.60 2.18
62 17.13 17.13 1.29 16.56 16.56 1.43 15.98 15.98 1.59 15.37 15.37 1.77 14.74 14.74 1.97 14.07 14.07 2.19
57 17.10 17.10 1.29 16.56 16.56 1.43 15.98 15.98 1.59 15.38 15.38 1.77 14.74 14.74 1.97 14.07 14.07 2.19
525
600
675
Cooling Indoor
Model
*FA4CN(F,C)018 1.00 1.00
FF1ENE018 0.99 0.99
FF1ENE024 1.01 1.01
FK4DNF001 1.02 0.88
FC4DNF018 1.02 0.92
FC4DNF024 1.03 0.89
FA4CN(F,C)024 1.00 1.00
FK4DNF002 1.03 0.89
CAR**2414A** 1.01 1.01
CAR**2417A** 1.01 1.01
CNRF*2418A** 1.02 1.00
CNRV*1814A** 1.01 1.01
CNRH*2417A** 1.02 1.00
CAR**1814A** 0.98 0.88 58CV(A,X)070---12
CNRV*2414A** 1.02 1.00
CAR**2414A** 1.01 0.87 58CV(A,X)070---12
CNRV*2417A** 1.02 1.00
CSRH*2412A** 1.02 1.00
CNRH*2417A** 1.01 0.87 58CV(A,X)070--- 12
CAR**2417A** 1.01 0.87 58CV(A,X)090---16
CNRV*1814A** 1.01 0.91 58CV(A,X)070--- 12
CNRV*2414A** 1.01 0.87 58CV(A,X)070--- 12
CSRH*2412A** 1.02 0.88 58CV(A,X)070--- 12
CNRV*2417A** 1.02 0.88 58CV(A,X)090--- 16
CNRH*2417A** 1.02 0.88 58CV(A,X)090--- 16
CAR**2417A** 1.01 0.87 58MVB060---14
CSRH*2412A** 1.02 0.88 58CV(A,X)090--- 16
CSRH*2412A** 1.02 0.88 58MVB040 ---14
CNRH*2417A** 1.01 0.87 58MVB040--- 14
CNRV*2417A** 1.01 0.87 58MVB060--- 14
CNRH*2417A** 1.01 0.87 58MVB060--- 14
17
Page 18
Tot a l
Tot a l
Capacity MBtuh
KW
System
KW
System
Capacity Power Furna ce M odel
25HCR3C
Cooling Indoor
Model
CAR**2417A** 1.01 0.93 58UVB060--- 14
CSRH*2412A** 1.01 0.93 58MVB080--- 20
CSRH*3012A** 1.02 0.94 58MVB080--- 20
CSRH*2412A** 1.01 0.93 58MVB100--- 20
CNRH*2417A** 1.01 0.93 58MVB080 ---20
CNRH*3017A** 1.02 0.94 58MVB080 ---20
CSRH*3012A** 1.02 0.94 58MVB100--- 20
CNRH*2417A** 1.01 0.93 58MVB100 ---20
CNRH*3017A** 1.02 0.94 58MVB100 ---20
CNRH*2417A** 1.01 0.95 58MVB120 ---20
CNRH*3017A** 1.02 0.94 58MVB120 ---20
CAR**3017A** 1.02 0.94 58UVB060--- 14
CSRH*2412A** 1.00 0.92 58MVB120--- 20
CSRH*3012A** 1.01 0.93 58MVB120--- 20
CNRV*2417A** 1.01 0.93 58UVB060 --- 14
CNRV*3017A** 1.02 0.94 58UVB060 --- 14
Capacity MBtuh
See notes on page 23
KW
Tot a l
System
Capacity MBtuh
KW
Tot a l
System
Capacity Power Furna ce M odel
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
25HCR324C Outdoor Section With FA4CN(F,C)024 Indoor Section
KW
Tot a l
System
Cooling Indoor
Model
CAR**2417A** 1.01 0.93 58MVB060--- 14
CNRV*2417A** 1.01 0.93 58CV(A,X)090--- 16
CNRV*3017A** 1.02 0.94 58CV(A,X)090--- 16
CSRH*2412A** 1.01 0.93 58CV(A,X)090--- 16
CSRH*3012A** 1.02 0.94 58CV(A,X)090--- 16
CSRH*2412A** 1.01 0.93 58CV(A,X)110--- 20
CSRH*3012A** 1.02 0.94 58CV(A,X)110--- 20
CSRH*2412A** 1.01 0.93 58CV(A,X)135--- 22
CSRH*3012A** 1.02 0.94 58CV(A,X)135--- 22
CSRH*2412A** 1.01 0.93 58CV(A,X)155--- 22
CNRH*3017A** 1.02 0.94 58CV(A,X)090---16
CNRH*2417A** 1.01 0.93 58CV(A,X)110---20
CNRH*3017A** 1.02 0.94 58CV(A,X)110---20
CNRH*2417A** 1.01 0.93 58CV(A,X)135---22
CNRH*3017A** 1.02 0.94 58CV(A,X)135---22
CSRH*3012A** 1.02 0.94 58CV(A,X)155--- 22
CNRH*2417A** 1.01 0.93 58CV(A,X)155---22
CNRH*3017A** 1.02 0.94 58CV(A,X)155---22
CNRH*2417A** 1.01 0.93 58MVB040 ---14
CNRH*3017A** 1.02 0.94 58MVB040 ---14
CAR**3017A** 1.02 0.94 58MVB060--- 14
CSRH*2412A** 1.01 0.93 58MVB040--- 14
CSRH*3012A** 1.02 0.94 58MVB040--- 14
CNRV*2417A** 1.01 0.93 58MVB060--- 14
CNRV*3017A** 1.02 0.94 58MVB060--- 14
CSRH*2412A** 1.01 0.93 58MVB060--- 14
CSRH*3012A** 1.01 0.93 58MVB060--- 14
CSRH*2412A** 1.01 0.93 58MVB080--- 14
CNRH*2417A** 1.01 0.93 58MVB060 ---14
CNRH*3017A** 1.02 0.94 58MVB060 ---14
CSRH*3012A** 1.02 0.94 58MVB080--- 14
CNRH*2417A** 1.01 0.93 58MVB080 ---14
CNRH*3017A** 1.02 0.94 58MVB080 ---14
Capacity MBtuh
KW
Tot a l
System
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Capacity MBtuh
Tot a l Sens Tot a l Sens To ta l Sens Tot al Sens Tot al Sens Tot al Sens
72 27.28 14.15 1.66 26.28 13.76 1.86 25.23 13.36 2.07 24.14 12.95 2.31 23.00 12.53 2.57 21.81 12.09 2.85
67 24.75 17.62 1.66 23.82 17.22 1.85 22.84 16.82 2.06 21.83 16.39 2.30 20.77 15.95 2.55 19.67 15.49 2.83
63 22.95 17.00 1.65 22.07 16.60 1.84 21.15 16.18 2.05 20.19 15.75 2.29 19.19 15.30 2.54 18.14 14.83 2.82
62 22.57 21.07 1.65 21.72 20.64 1.84 20.85 20.18 2.05 19.95 19.68 2.29 19.05 19.05 2.54 18.20 18.20 2.82
57 22.04 22.04 1.65 21.34 21.34 1.84 20.61 20.61 2.05 19.85 19.85 2.29 19.05 19.05 2.54 18.20 18.20 2.82
72 27.75 14.81 1.70 26.71 14.42 1.90 25.63 14.02 2.11 24.50 13.61 2.35 23.32 13.18 2.61 22.08 12.73 2.89
67 25.18 18.74 1.70 24.21 18.33 1.89 23.20 17.92 2.10 22.15 17.48 2.34 21.06 17.03 2.59 19.92 16.56 2.87
63 23.34 18.04 1.69 22.43 17.63 1.88 21.48 17.20 2.09 20.49 16.76 2.33 19.46 16.30 2.58 18.38 15.82 2.86
62 23.06 22.49 1.69 22.21 21.99 1.88 21.36 21.36 2.09 20.56 20.56 2.33 19.71 19.71 2.59 18.82 18.82 2.86
57 22.87 22.87 1.69 22.13 22.13 1.88 21.36 21.36 2.09 20.56 20.56 2.33 19.71 19.71 2.59 18.82 18.82 2.86
72 28.10 15.45 1.74 27.03 15.05 1.93 25.91 14.64 2.15 24.75 14.23 2.39 23.54 13.79 2.64 22.28 13.34 2.93
67 25.49 19.80 1.73 24.50 19.39 1.92 23.46 18.96 2.14 22.39 18.51 2.37 21.27 18.05 2.63 20.11 17.57 2.91
63 23.64 19.02 1.73 22.71 18.61 1.92 21.73 18.17 2.13 20.72 17.72 2.37 19.66 17.25 2.62 18.57 16.75 2.90
62 23.56 23.56 1.73 22.79 22.79 1.92 21.98 21.98 2.13 21.14 21.14 2.37 20.26 20.26 2.63 19.33 19.33 2.91
CFM EWB
EVAPORATOR AIR
DETAILED COOLING CAPACITIES (CONT.)
700
800
900
Capacity Power Furna ce M odel
57 23.56 23.56 1.73 22.79 22.79 1.92 21.99 21.99 2.13 21.14 21.14 2.37 20.26 20.26 2.63 19.33 19.33 2.91
Cooling Indoor
Model
*FA4CN(F,C)024 1.00 1.00
FF1ENE024 1.01 1.01
FF1ENE030 1.01 1.01
FK4DNF001 1.02 0.92
FC4DNF024 1.03 0.92
FC4DNF030 1.03 0.93
FA4CN(F,C)030 1.02 1.00
FK4DNF002 1.03 0.89
CAR**2414A** 1.01 1.01
CAR**2417A** 1.01 1.01
CAR**3014A** 1.02 1.02
FK4DN(B,F)003 1.03 0.89
CAR**3017A** 1.02 1.02
CNRF*2418A** 1.01 1.01
CNRV*2414A** 1.01 1.01
CNRV*2417A** 1.01 1.01
CNRH*2417A** 1.01 1.01
CNRV*3014A** 1.02 1.02
CNRH*3017A** 1.02 1.02
CAR**2414A** 1.01 0.93 58CV(A,X)070--- 12
CNRV*3017A** 1.02 1.02
CAR**3014A** 1.01 0.93 58CV(A,X)070--- 12
CSRH*2412A** 1.01 0.99
CSRH*3012A** 1.02 1.00
CNRV*2414A** 1.01 0.93 58CV(A,X)070--- 12
CNRH*2417A** 1.01 0.93 58CV(A,X)070---12
CNRH*3017A** 1.02 0.94 58CV(A,X)070---12
CAR**2417A** 1.01 0.93 58CV(A,X)090--- 16
CNRV*3014A** 1.02 0.94 58CV(A,X)070--- 12
CAR**3017A** 1.02 0.94 58CV(A,X)090--- 16
CSRH*2412A** 1.01 0.93 58CV(A,X)070--- 12
CSRH*3012A** 1.01 0.93 58CV(A,X)070--- 12
CNRH*2417A** 1.01 0.93 58CV(A,X)090---16
18
Page 19
Tot a l
Tot a l
Capacity MBtuh
KW
System
KW
System
Capacity Power Fur nace Mod el
Capacity MBtuh
Cooling Indoor
Model
CAR**3017A** 0.99 0.99 58UVB060 --- 14
CAR**3617A** 0.99 0.98 58UVB060 --- 14
CAR**3621A** 0.99 0.98 58UVB080 --- 20
CSRH*3612A** 1.01 0.98 58MVB120--- 20
CAR**3621A** 0.99 0.98 58UVB100 --- 20
CNRV*3017A** 0.99 0.99 58UVB060--- 14
CNRV*3617A** 0.99 0.99 58UVB060--- 14
CNRV*3621A** 0.99 0.99 58UVB080--- 14
CNRV*3621A** 0.99 0.99 58UVB080--- 20
CNRV*3621A** 0.99 0.99 58UVB100--- 20
See notes on page 23
KW
Tot a l
System
Capacity MBtuh
KW
Tot a l
System
Cooling Indoor
Capacity Power Fur nace Mod el
Model
CAR**3017A** 0.99 0.99 58MVB060--- 14
CSRH*3612A** 1.02 0.98 58CV(A,X)155--- 22
CNRH*3017A** 0.99 0.99 58MVB040---14
CNRH*3617A** 0.99 0.99 58MVB040---14
CAR**3617A** 0.99 0.98 58MVB060--- 14
CSRH*3012A** 0.99 0.99 58MVB040--- 14
CSRH*3612A** 1.01 1.00 58MVB040--- 14
CNRV*3017A** 0.99 0.99 58MVB060 --- 14
CNRV*3617A** 0.99 0.99 58MVB060 --- 14
CSRH*3012A** 0.99 0.99 58MVB060--- 14
CNRH*3017A** 0.99 0.99 58MVB060---14
CNRH*3617A** 0.99 0.99 58MVB060---14
CSRH*3612A** 1.01 1.00 58MVB060--- 14
CNRH*3017A** 0.99 0.99 58MVB080---14
CNRH*3617A** 0.99 0.99 58MVB080---14
CAR**3621A** 0.99 0.98 58MVB080--- 20
CNRV*3621A** 0.99 0.99 58MVB080 --- 14
CSRH*3012A** 0.99 0.99 58MVB080--- 14
CSRH*3612A** 1.01 1.00 58MVB080--- 14
CNRH*3017A** 0.99 0.99 58MVB080---20
CNRH*3617A** 0.99 0.99 58MVB080---20
CAR**3621A** 0.99 0.98 58MVB100--- 20
CNRV*3621A** 0.99 0.99 58MVB080 --- 20
CSRH*3012A** 0.99 0.99 58MVB080--- 20
CSRH*3612A** 1.01 1.00 58MVB080--- 20
CNRV*3621A** 0.99 0.99 58MVB100 --- 20
CSRH*3012A** 0.99 0.98 58MVB100--- 20
CNRH*3017A** 0.99 0.99 58MVB100---20
CSRH*3612A** 1.01 0.98 58MVB100--- 20
CNRH*3617A** 0.99 0.99 58MVB100---20
CNRH*3017A** 0.99 0.97 58MVB120---20
CNRH*3617A** 0.99 0.97 58MVB120---20
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
25HCR330C Outdoor Section With FC4DN F030 Indoor Section
KW
Tot a l
System
25HCR3C
CSRH*3012A** 0.99 0.98 58MVB120--- 20
Capacity MBtuh
KW
Tot a l
System
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Capacity MBtuh
Tot a l Sens Tot a l Sens To ta l Sens Tot al Sens Tot al Sens Tot al Sens
72 33.71 17.70 2.10 32.43 17.20 2.35 31.12 16.69 2.63 29.78 16.17 2.95 28.37 15.64 3.29 26.90 15.08 3.66
67 30.73 21.88 2.10 29.54 21.37 2.36 28.32 20.84 2.64 27.07 20.31 2.95 25.76 19.75 3.29 24.38 19.17 3.66
63 28.57 21.16 2.11 27.45 20.64 2.36 26.30 20.11 2.64 25.11 19.56 2.95 23.86 18.99 3.29 22.55 18.40 3.65
62 28.09 26.01 2.11 27.01 25.45 2.36 25.91 24.87 2.64 24.78 24.26 2.95 23.61 23.58 3.29 22.45 22.45 3.65
57 27.22 27.22 2.11 26.34 26.34 2.36 25.44 25.44 2.64 24.49 24.49 2.95 23.50 23.50 3.29 22.45 22.45 3.65
72 34.33 18.52 2.12 32.99 18.01 2.38 31.63 17.49 2.66 30.24 16.97 2.97 28.79 16.43 3.32 27.27 15.87 3.69
67 31.30 23.22 2.13 30.07 22.70 2.38 28.80 22.16 2.67 27.51 21.62 2.98 26.15 21.05 3.32 24.74 20.45 3.69
63 29.11 22.42 2.14 27.95 21.89 2.39 26.76 21.34 2.67 25.53 20.79 2.98 24.25 20.20 3.32 22.90 19.60 3.68
62 28.72 27.74 2.14 27.62 27.13 2.39 26.51 26.47 2.67 25.39 25.39 2.98 24.33 24.33 3.32 23.23 23.23 3.69
57 28.26 28.26 2.14 27.34 27.34 2.39 26.38 26.38 2.67 25.39 25.39 2.98 24.34 24.34 3.32 23.23 23.23 3.69
72 34.80 19.31 2.15 33.43 18.79 2.40 32.03 18.27 2.69 30.60 17.74 3.00 29.11 17.20 3.35 27.55 16.63 3.72
67 31.75 24.52 2.16 30.48 23.99 2.41 29.17 23.44 2.69 27.85 22.88 3.01 26.46 22.29 3.35 25.02 21.68 3.72
63 29.54 23.63 2.16 28.35 23.09 2.42 27.13 22.54 2.70 25.87 21.96 3.01 24.55 21.37 3.35 23.18 20.74 3.71
62 29.28 29.25 2.16 28.19 28.19 2.42 27.16 27.16 2.70 26.13 26.13 3.01 25.03 25.03 3.35 23.88 23.88 3.72
CFM EWB
EVAPORATOR AIR
DETAILED COOLING CAPACITIES (CONT.)
875
1000
1125
Capacity Power Fur nace Mod el
57 29.14 29.14 2.16 28.17 28.17 2.42 27.17 27.17 2.70 26.13 26.13 3.01 25.04 25.04 3.35 23.89 23.89 3.72
Model
Cooling Indoor
FK4DNF001 0.99 0.99
*FC4DNF030 1.00 1.00
FK4DNF002 1.00 0.98
FC4DN(F,B)036 1.01 1.01
CAR**3014A** 0.99 0.99 58CV(A,X)070--- 12
FK4DN(B,F)003 1.00 0.96
CAR**3614A** 0.99 0.99 58CV(A,X)070--- 12
CNRH*3017A** 0.99 0.99 58CV(A,X)070--- 12
CNRH*3617A** 0.99 0.99 58CV(A,X)070--- 12
CAR**3017A** 0.99 0.97 58CV(A,X)090--- 16
CNRV*3014A** 0.99 0.99 58CV(A,X)070---12
CAR**3617A** 0.99 0.98 58CV(A,X)090--- 16
CSRH*3012A** 0.99 0.99 58CV(A,X)070--- 12
CSRH*3612A** 1.01 1.00 58CV(A,X)070--- 12
CNRV*3017A** 0.99 0.98 58CV(A,X)090---16
CNRH*3017A** 0.99 0.98 58CV(A,X)090--- 16
CNRH*3617A** 0.99 0.98 58CV(A,X)090--- 16
CAR**3621A** 1.00 0.98 58CV(A,X)110--- 20
CNRV*3617A** 0.99 0.99 58CV(A,X)090---16
CSRH*3012A** 0.99 0.98 58CV(A,X)090--- 16
CSRH*3612A** 1.01 0.98 58CV(A,X)090--- 16
CNRV*3621A** 0.99 0.98 58CV(A,X)110---20
CSRH*3012A** 1.00 0.98 58CV(A,X)110--- 20
CSRH*3612A** 1.02 0.98 58CV(A,X)110--- 20
CSRH*3012A** 1.00 0.98 58CV(A,X)135--- 22
CSRH*3612A** 1.02 0.98 58CV(A,X)135--- 22
CNRH*3017A** 0.99 0.99 58CV(A,X)110--- 20
CNRH*3617A** 0.99 0.98 58CV(A,X)110--- 20
CNRH*3017A** 0.99 0.98 58CV(A,X)135--- 22
CNRH*3617A** 0.99 0.98 58CV(A,X)135--- 22
CSRH*3012A** 1.00 0.98 58CV(A,X)155--- 22
CNRH*3017A** 0.99 0.98 58CV(A,X)155--- 22
CNRH*3617A** 0.99 0.98 58CV(A,X)155--- 22
19
Page 20
25HCR3C
Tot a l
Tot a l
Tot a l
Capacity MBtuh
Capacity MBtuh
Capacity MBtuh
KW
System
KW
System
CAR**3617A** 0.98 0.98 58UVB060--- 14
CAR**3621A** 0.98 0.98 58UVB080--- 14
CAR**4221A** 0.98 0.98 58UVB080--- 14
CAR**3621A** 0.98 0.98 58UVB080--- 20
CAR**4221A** 0.99 0.97 58UVB080--- 20
CAR**3621A** 0.98 0.96 58UVB100--- 20
CAR**4221A** 0.99 0.97 58UVB100--- 20
CSRH*3612A** 0.98 0.96 58MVB120--- 20
CSRH*4212A** 0.99 0.95 58MVB120--- 20
CNRV*3617A** 0.98 0.98 58UVB060--- 14
CNRV*4221A** 0.99 0.97 58UVB080--- 14
CNRV*3621A** 0.98 0.98 58UVB080--- 20
CNRH*4221A** 0.99 0.96 58MVB120--- 20
Cooling Indoor Model Capacity Power Furnace Mo del
CNRV*4221A** 0.99 0.98 58UVB080--- 20
CAR**4224A** 0.99 0.97 58UVB120--- 20
CNRV*3621A** 0.98 0.98 58UVB100--- 20
CNRV*4221A** 0.99 0.96 58UVB100--- 20
See notes on page 23
KW
System
KW
Tot a l
System
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
KW
25HCR336C30 Outdoor Section With FC4DN (F,B)036 Indoor Section
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Tot a l
Tot a l
Capacity MBtuh
Capacity MBtuh
System
KW
System
Tot a l Sens To ta l Sens Tot a l Sens Tot a l Sens Tot al Sens To ta l Sens
CNRH*3617A** 0.97 0.97 58MVB040--- 14
Cooling Indoor Model Capacity Power Furnace Mo del
CAR**3617A** 0.98 0.98 58MVB060--- 14
CSRH*3612A** 0.97 0.95 58MVB040--- 14
CSRH*4212A** 0.98 0.96 58MVB040--- 14
CNRH*4221A** 0.99 0.97 58MVB040--- 14
CNRH*3617A** 0.98 0.98 58MVB060--- 14
CNRH*4221A** 0.99 0.96 58MVB060--- 14
CAR**3621A** 0.98 0.98 58MVB080--- 14
CNRV*3617A** 0.98 0.98 58MVB060--- 14
CAR**4221A** 0.98 0.98 58MVB080--- 14
CSRH*3612A** 0.98 0.96 58MVB060--- 14
CSRH*4212A** 0.99 0.95 58MVB060--- 14
CNRH*4221A** 0.99 0.97 58MVB080--- 14
CAR**3621A** 0.98 0.98 58MVB080--- 20
CNRV*4221A** 0.99 0.97 58MVB080--- 14
CAR**4221A** 0.99 0.97 58MVB080--- 20
CSRH*3612A** 0.97 0.97 58MVB080--- 14
CSRH*4212A** 0.98 0.96 58MVB080--- 14
CNRV*3621A** 0.98 0.98 58MVB080--- 20
CNRH*3617A** 0.98 0.98 58MVB080--- 20
CNRH*4221A** 0.99 0.98 58MVB080--- 20
CAR**3621A** 0.98 0.96 58MVB100--- 20
CNRV*4221A** 0.99 0.98 58MVB080--- 20
CAR**4221A** 0.99 0.97 58MVB100--- 20
CSRH*3612A** 0.98 0.96 58MVB080--- 20
CSRH*4212A** 0.99 0.95 58MVB080--- 20
CNRV*3621A** 0.98 0.98 58MVB100--- 20
CNRH*3617A** 0.98 0.98 58MVB100--- 20
CNRH*4221A** 0.99 0.96 58MVB100--- 20
CAR**4224A** 0.99 0.97 58MVB120--- 20
CNRV*4221A** 0.99 0.96 58MVB100--- 20
CSRH*3612A** 0.98 0.96 58MVB100--- 20
CSRH*4212A** 0.99 0.95 58MVB100--- 20
CNRH*3617A** 0.98 0.98 58MVB120--- 20
72 40.55 21.23 2.54 39.05 20.65 2.81 37.51 20.07 3.11 35.91 19.46 3.44 34.23 18.83 3.80 32.48 18.19 4.19
67 36.85 26.34 2.51 35.47 25.75 2.78 34.04 25.14 3.08 32.55 24.52 3.41 31.00 23.87 3.77 29.38 23.19 4.16
63 34.20 25.42 2.50 32.90 24.82 2.76 31.55 24.21 3.06 30.15 23.58 3.39 28.68 22.92 3.75 27.15 22.23 4.13
62 33.67 31.35 2.49 32.43 30.70 2.76 31.15 30.01 3.06 29.83 29.27 3.39 28.47 28.47 3.74 27.21 27.21 4.13
57 32.84 32.84 2.49 31.82 31.82 2.76 30.75 30.75 3.06 29.63 29.63 3.38 28.45 28.45 3.74 27.22 27.22 4.13
72 41.27 22.23 2.58 39.72 21.65 2.84 38.12 21.06 3.15 36.46 20.44 3.48 34.73 19.81 3.84 32.92 19.15 4.23
67 37.51 27.97 2.55 36.08 27.37 2.82 34.60 26.76 3.12 33.06 26.12 3.45 31.46 25.45 3.81 29.80 24.76 4.20
63 34.83 26.95 2.54 33.48 26.34 2.80 32.09 25.72 3.10 30.64 25.07 3.43 29.13 24.39 3.79 27.56 23.68 4.17
62 34.43 33.40 2.53 33.18 32.66 2.80 31.89 31.89 3.10 30.69 30.69 3.43 29.45 29.45 3.79 28.14 28.14 4.18
57 34.08 34.08 2.53 33.00 33.00 2.80 31.87 31.87 3.10 30.69 30.69 3.43 29.45 29.45 3.79 28.15 28.15 4.18
72 41.84 23.20 2.61 40.24 22.61 2.88 38.60 22.01 3.18 36.89 21.39 3.52 35.11 20.75 3.88 33.26 20.09 4.27
67 38.04 29.56 2.59 36.57 28.95 2.86 35.05 28.31 3.16 33.47 27.66 3.49 31.83 26.97 3.85 30.13 26.25 4.24
63 35.33 28.43 2.57 33.95 27.81 2.84 32.52 27.17 3.14 31.03 26.50 3.47 29.49 25.80 3.82 27.89 25.07 4.21
62 35.14 35.14 2.57 33.98 33.98 2.84 32.80 32.80 3.14 31.57 31.57 3.47 30.27 30.27 3.83 28.91 28.91 4.22
57 35.11 35.11 2.57 33.98 33.98 2.84 32.81 32.81 3.14 31.57 31.57 3.47 30.28 30.28 3.83 28.92 28.92 4.23
FK4DNF002 0.98 0.98
FK4DNF003 0.99 0.95
FC4DN(F,B)042 1.02 1.00
CAR**3614A** 0.95 0.95 58CV(A,X)070--- 12
EVAPORATOR AIR
CFM EWB
1050
1200
1350
*FC4DN(F,B)036 1.00 1.00
Cooling Indoor Model Capacity Power Furnace Mo del
CNRH*3617A** 0.98 0.98 58CV(A,X)070---12
CAR**3617A** 0.98 0.96 58CV(A,X)090--- 16
CSRH*3612A** 0.97 0.95 58CV(A,X)070--- 12
CSRH*4212A** 0.99 0.97 58CV(A,X)070--- 12
CNRH*4221A** 0.99 0.97 58CV(A,X)070---12
CNRH*3617A** 0.98 0.98 58CV(A,X)090---16
CNRH*4221A** 0.99 0.96 58CV(A,X)090---16
CAR**3621A** 0.98 0.96 58CV(A,X)110--- 20
CNRV*3617A** 0.98 0.98 58CV(A,X)090---16
CAR**4221A** 0.99 0.98 58CV(A,X)110--- 20
CSRH*3612A** 0.98 0.95 58CV(A,X)090--- 16
CSRH*4212A** 0.99 0.95 58CV(A,X)090--- 16
CNRV*3621A** 0.98 0.98 58CV(A,X)110---20
CNRH*3617A** 0.98 0.98 58CV(A,X)110---20
CNRH*4221A** 1.00 0.96 58CV(A,X)110---20
CAR**4224A** 0.99 0.96 58CV(A,X)135--- 22
CNRV*4221A** 1.00 0.96 58CV(A,X)110---20
CSRH*3612A** 0.98 0.95 58CV(A,X)110--- 20
CSRH*4212A** 0.99 0.96 58CV(A,X)110--- 20
CNRH*3617A** 0.98 0.98 58CV(A,X)135---22
CAR**4224A** 0.99 0.96 58CV(A,X)155--- 22
CSRH*3612A** 0.98 0.95 58CV(A,X)135--- 22
CSRH*4212A** 0.99 0.96 58CV(A,X)135--- 22
CNRH*4221A** 1.00 0.96 58CV(A,X)135---22
CNRH*3617A** 0.98 0.96 58CV(A,X)155---22
CAR**4224A** 0.99 0.99 58MVB040--- 14
CSRH*3612A** 0.98 0.95 58CV(A,X)155--- 22
CSRH*4212A** 0.99 0.93 58CV(A,X)155--- 22
CNRH*4221A** 1.00 0.96 58CV(A,X)155---22
DETAILED COOLING CAPACITIES (CONT.)
20
Page 21
Tot a l
Tot a l
Tot a l
Capacity MBtuh
Capacity MBtuh
Capacity MBtuh
KW
System
KW
System
25HCR3C
KW
System
KW
Tot a l
System
Capacity Power Furna ce M odel
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
Model
CAR**4224A** 0.96 0.96 58MVB040---14
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Tot a l
Tot a l
Capacity MBtuh
Capacity MBtuh
Cooling Indoor
25HCR342C Outdoor Section With FC4DN (F,B)042 Indoor Section
KW
System
KW
System
Tot a l Sens Tot a l Sens To ta l Sens To tal Sens Tot a l Sens To ta l Sens
CNRV*4824A** 0.99 0.94 58CV(A,X)155--- 22
Capacity Power Furna ce M odel
CAR**4824A** 0.98 0.98 58MVB040---14
CSRH*4212A** 1.00 0.98 58CV(A,X)155--- 22
CSRH*4812A** 1.00 0.96 58CV(A,X)155--- 22
CNRH*4221A** 0.96 0.98 58MVB040--- 14
CNRH*4821A** 0.99 0.99 58MVB040--- 14
CAR**4817A** 0.99 0.97 58UVB060--- 14
CAR**4221A** 0.96 0.98 58UVB080--- 14
CAR**4821A** 0.98 0.96 58UVB080--- 14
CAR**4221A** 0.96 0.96 58UVB080--- 20
CAR**4821A** 0.99 0.99 58UVB080--- 20
CAR**4221A** 0.96 0.96 58UVB100--- 20
CAR**4821A** 0.99 0.97 58UVB100--- 20
CAR**4224A** 0.96 0.96 58UVB120--- 20
CNRV*4824A** 0.99 0.99 58MVB040--- 14
CSRH*4212A** 0.99 0.99 58MVB040 ---14
CSRH*4812A** 0.99 0.99 58MVB040 ---14
CNRV*4221A** 0.96 0.98 58UVB080--- 14
CNRV*4821A** 0.99 0.99 58UVB080--- 14
CNRV*4221A** 0.96 0.96 58UVB080--- 20
CNRV*4821A** 0.99 0.97 58UVB080--- 20
CAR**4824A** 0.99 0.97 58UVB120--- 20
CNRV*4221A** 0.96 0.96 58UVB100--- 20
CNRV*4821A** 0.99 0.97 58UVB100--- 20
CNRV*4824A** 0.99 0.97 58UVB120--- 20
See notes on page 23
72 48.00 25.34 3.06 46.19 24.62 3.37 44.32 23.88 3.71 42.41 23.14 4.08 40.44 22.38 4.50 38.42 21.61 4.96
67 43.74 31.37 3.03 42.06 30.62 3.33 40.33 29.86 3.67 38.56 29.10 4.04 36.74 28.32 4.46 34.89 27.54 4.91
63 40.58 30.29 3.00 39.00 29.54 3.30 37.38 28.78 3.64 35.72 28.01 4.01 34.03 27.23 4.42 32.30 26.45 4.88
62 39.85 37.28 3.00 38.32 36.49 3.30 36.76 35.67 3.63 35.19 34.82 4.01 33.60 33.91 4.42 32.06 32.06 4.88
57 38.59 38.59 2.99 37.36 37.36 3.29 36.09 36.09 3.63 34.78 34.78 4.00 33.44 33.44 4.42 32.06 32.06 4.88
72 48.86 26.50 3.12 46.97 25.77 3.43 45.04 25.03 3.77 43.06 24.28 4.14 41.02 23.51 4.56 38.93 22.73 5.02
67 44.55 33.29 3.09 42.80 32.54 3.39 41.00 31.76 3.73 39.16 30.98 4.10 37.28 30.19 4.52 35.37 29.38 4.97
63 41.37 32.11 3.06 39.72 31.34 3.36 38.03 30.57 3.70 36.31 29.78 4.07 34.56 28.98 4.48 32.78 28.17 4.94
62 40.75 39.81 3.06 39.19 38.95 3.36 37.61 38.00 3.69 36.07 36.07 4.07 34.64 34.64 4.48 33.17 33.17 4.94
57 40.11 40.11 3.05 38.80 38.80 3.35 37.45 37.45 3.69 36.07 36.07 4.07 34.64 34.64 4.48 33.17 33.17 4.94
72 49.50 27.60 3.18 47.56 26.87 3.48 45.57 26.12 3.82 43.54 25.35 4.20 41.44 24.58 4.62 39.29 23.79 5.08
67 45.15 35.12 3.14 43.35 34.35 3.45 41.49 33.57 3.78 39.61 32.77 4.16 37.68 31.96 4.57 35.72 31.13 5.03
63 41.97 33.83 3.12 40.28 33.05 3.42 38.53 32.26 3.75 36.76 31.45 4.13 34.97 30.63 4.54 33.14 29.80 5.00
62 41.56 41.99 3.11 40.02 40.02 3.42 38.58 38.58 3.76 37.12 37.12 4.13 35.63 35.63 4.55 34.09 34.09 5.01
57 41.38 41.38 3.11 40.01 40.01 3.42 38.59 38.59 3.76 37.13 37.13 4.13 35.63 35.63 4.55 34.09 34.09 5.01
Model
Cooling Indoor
CSRH*4812A** 1.01 1.03
CFM EWB
EVAPORATOR AIR
DETAILED COOLING CAPACITIES (CONT.)
1225
1400
1575
*FC4DN(F,B)042 1.00 1.00
FK4DNB006 1.02 0.94
FC4DN(F,B)048 1.02 1.01
FK4DN(B,F)003 0.98 0.96
FK4DN(B,F)005 1.01 0.93
CNRH*4221A** 0.96 0.98 58CV(A,X)070--- 12
CAR**4817A** 1.00 0.98 58CV(A,X)090---16
CSRH*4212A** 0.99 0.99 58CV(A,X)070--- 12
CSRH*4812A** 0.99 0.99 58CV(A,X)070--- 12
CNRH*4821A** 0.99 0.99 58CV(A,X)070--- 12
CNRH*4221A** 0.98 0.98 58CV(A,X)090--- 16
CAR**4221A** 0.98 0.96 58CV(A,X)110---20
CAR**4821A** 0.99 0.97 58CV(A,X)110---20
CSRH*4212A** 0.99 0.97 58CV(A,X)090--- 16
CSRH*4812A** 1.00 0.98 58CV(A,X)090--- 16
CNRH*4821A** 0.99 0.97 58CV(A,X)090--- 16
CNRV*4221A** 0.98 0.98 58CV(A,X)110--- 20
CNRH*4221A** 0.98 0.98 58CV(A,X)110--- 20
CNRH*4821A** 0.99 0.97 58CV(A,X)110--- 20
CAR**4224A** 0.98 0.96 58CV(A,X)135---22
CNRV*4821A** 0.99 0.97 58CV(A,X)110--- 20
CAR**4824A** 0.99 0.97 58CV(A,X)135---22
CSRH*4212A** 1.00 0.98 58CV(A,X)110--- 20
CSRH*4812A** 1.00 0.98 58CV(A,X)110--- 20
CNRH*4221A** 0.98 0.96 58CV(A,X)135--- 22
CNRH*4821A** 0.99 0.97 58CV(A,X)135--- 22
CAR**4224A** 0.98 0.96 58CV(A,X)155---22
CNRV*4824A** 0.99 0.97 58CV(A,X)135--- 22
CAR**4824A** 0.99 0.97 58CV(A,X)155---22
CSRH*4212A** 1.00 0.98 58CV(A,X)135--- 22
CSRH*4812A** 1.00 0.98 58CV(A,X)135--- 22
CNRH*4221A** 0.98 0.96 58CV(A,X)155--- 22
CNRH*4821A** 0.99 0.94 58CV(A,X)155--- 22
21
Page 22
Tot a l
Tot a l
Capacity MBtuh
Capacity MBtuh
KW
System
KW
System
25HCR3C
KW
Tot a l
System
Capacity MBtuh
KW
Tot a l
System
Power Furn ace Model
city
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
25HCR348C30 Outdoor Section With FC4DN (F,B)048 Indoor Section
KW
Tot a l
System
Capa-
Cooling Indoor
Model
CAR**4821A** 0.96 0.96 58MVB100---20
CNRV*4821A** 0.96 0.96 58MVB080 --- 20
CNRH*4821A** 0.96 0.96 58MVB080--- 20
CNRH*6024A** 0.98 0.96 58MVB080--- 20
CAR**6021A** 0.99 0.95 58MVB100---20
CSRH*4812A** 0.96 0.96 58MVB080--- 20
CSRH*6012A** 0.98 0.94 58MVB080--- 20
CNRH*4821A** 0.96 0.94 58MVB100--- 20
CNRH*6024A** 0.98 0.94 58MVB100--- 20
CAR**4824A** 0.96 0.94 58MVB120---20
CNRV*4821A** 0.96 0.94 58MVB100 --- 20
CAR**6024A** 0.98 0.94 58MVB120---20
CSRH*4812A** 0.96 0.94 58MVB100--- 20
CSRH*6012A** 0.98 0.94 58MVB100--- 20
CNRV*4824A** 0.96 0.94 58MVB120 --- 20
CNRH*4821A** 0.96 0.94 58MVB120--- 20
CNRH*6024A** 0.98 0.94 58MVB120--- 20
CAR**4821A** 0.96 0.96 58UVB080--- 20
CAR**6021A** 0.98 0.96 58UVB080--- 20
CAR**4821A** 0.96 0.96 58UVB100--- 20
CAR**6021A** 0.99 0.95 58UVB100--- 20
CAR**4824A** 0.96 0.94 58UVB120--- 20
CNRV*6024A** 0.98 0.94 58MVB120 --- 20
CSRH*4812A** 0.96 0.94 58MVB120--- 20
CSRH*6012A** 0.98 0.94 58MVB120--- 20
CNRV*4821A** 0.96 0.96 58UVB080 ---20
CAR**6024A** 0.98 0.94 58UVB120--- 20
CNRV*4821A** 0.96 0.94 58UVB100 ---20
CNRV*4824A** 0.96 0.94 58UVB120 ---20
CNRV*6024A** 0.98 0.94 58UVB120 ---20
See notes on page 23
Capacity MBtuh
KW
Tot a l
System
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Capacity MBtuh
Tot a l Sens Tot a l Sens To ta l Sens Tot al Sens Tot al Sens Tot al Sens
72 56.21 28.99 3.38 54.21 28.21 3.75 52.11 27.40 4.17 49.91 26.56 4.64 47.60 25.69 5.14 45.17 24.78 5.69
67 50.95 35.73 3.35 49.09 34.93 3.72 47.13 34.09 4.14 45.09 33.23 4.60 42.95 32.33 5.10 40.70 31.39 5.64
63 47.21 34.48 3.32 45.45 33.67 3.70 43.61 32.83 4.11 41.68 31.95 4.57 39.65 31.04 5.06 37.52 30.09 5.59
62 46.37 42.45 3.32 44.67 41.60 3.69 42.90 40.70 4.11 41.06 39.73 4.56 39.16 38.67 5.06 37.28 37.28 5.59
57 44.92 44.92 3.31 43.55 43.55 3.69 42.11 42.11 4.10 40.59 40.59 4.56 38.98 38.98 5.06 37.28 37.28 5.59
72 57.34 30.38 3.44 55.26 29.59 3.82 53.08 28.77 4.24 50.79 27.92 4.70 48.39 27.04 5.21 45.88 26.12 5.76
67 51.97 37.99 3.41 50.03 37.17 3.78 48.00 36.32 4.20 45.88 35.44 4.66 43.66 34.52 5.16 41.34 33.56 5.70
63 48.15 36.59 3.38 46.33 35.77 3.76 44.42 34.91 4.17 42.42 34.01 4.63 40.32 33.08 5.12 38.13 32.11 5.66
62 47.44 45.41 3.38 45.72 44.48 3.76 43.94 43.45 4.17 42.15 42.15 4.63 40.45 40.45 5.13 38.66 38.66 5.67
57 46.73 46.73 3.38 45.28 45.28 3.75 43.76 43.76 4.17 42.15 42.15 4.63 40.46 40.46 5.13 38.67 38.67 5.67
72 58.21 31.70 3.50 56.06 30.90 3.88 53.81 30.07 4.30 51.45 29.21 4.76 48.99 28.32 5.27 46.41 27.39 5.82
67 52.75 40.15 3.47 50.75 39.31 3.84 48.66 38.45 4.26 46.48 37.55 4.72 44.21 36.61 5.22 41.83 35.62 5.77
63 48.88 38.60 3.44 47.00 37.76 3.82 45.04 36.88 4.23 42.99 35.97 4.69 40.84 35.01 5.19 38.60 34.01 5.72
CFM EWB
EVAPORATOR AIR
DETAILED COOLING CAPACITIES (CONT.)
1400
1600
1800
Power Furn ace Model
city
Capa-
62 48.48 47.87 3.44 46.75 46.75 3.82 45.14 45.14 4.24 43.46 43.46 4.70 41.69 41.69 5.20 39.82 39.82 5.74
57 48.26 48.26 3.44 46.74 46.74 3.82 45.14 45.14 4.24 43.46 43.46 4.70 41.69 41.69 5.20 39.82 39.82 5.74
Model
Cooling Indoor
FK4DNF005 0.99 0.95
FK4DNB006 1.01 0.95
CAR**4817A** 0.94 0.92 58CV(A,X)090--- 16
CSRH*6012A** 0.98 0.98
*FC4DN(F,B)048 1.00 1.00
CNRH*4821A** 0.96 0.94 58CV(A,X)090---16
CAR**4821A** 0.96 0.94 58CV(A,X)110--- 20
CNRH*6024A** 0.98 0.94 58CV(A,X)090---16
CNRH*4821A** 0.97 0.95 58CV(A,X)110---20
CNRH*6024A** 0.99 0.95 58CV(A,X)110---20
CAR**6021A** 0.99 0.95 58CV(A,X)110--- 20
CSRH*4812A** 0.96 0.94 58CV(A,X)090--- 16
CSRH*6012A** 0.98 0.94 58CV(A,X)090--- 16
CAR**4824A** 0.97 0.93 58CV(A,X)135--- 22
CNRV*4821A** 0.96 0.94 58CV(A,X)110--- 20
CAR**6024A** 0.99 0.95 58CV(A,X)135--- 22
CSRH*4812A** 0.96 0.94 58CV(A,X)110--- 20
CSRH*6012A** 0.98 0.94 58CV(A,X)110--- 20
CNRV*4824A** 0.97 0.93 58CV(A,X)135--- 22
CNRH*4821A** 0.97 0.93 58CV(A,X)135---22
CNRH*6024A** 0.99 0.95 58CV(A,X)135---22
CAR**4824A** 0.97 0.93 58CV(A,X)155--- 22
CNRV*6024A** 0.99 0.95 58CV(A,X)135--- 22
CAR**6024A** 0.99 0.93 58CV(A,X)155--- 22
CSRH*4812A** 0.97 0.93 58CV(A,X)135--- 22
CSRH*6012A** 0.99 0.95 58CV(A,X)135--- 22
CNRV*4824A** 0.97 0.93 58CV(A,X)155--- 22
CNRH*4821A** 0.97 0.93 58CV(A,X)155---22
CNRH*6024A** 0.99 0.95 58CV(A,X)155---22
CAR**4821A** 0.96 0.96 58MVB080---20
CNRV*6024A** 0.99 0.95 58CV(A,X)155--- 22
CAR**6021A** 0.98 0.96 58MVB080---20
CSRH*4812A** 0.97 0.93 58CV(A,X)155--- 22
CSRH*6012A** 0.99 0.93 58CV(A,X)155--- 22
22
Page 23
Tot a l
Tot a l
Capacity MBtuh
Capacity MBtuh
KW
System
KW
System
KW
Tot a l
System
Capacity MBtuh
KW
Tot a l
System
CONDEN SER ENTERING AIR TEMPERATUR ES deg ˚F(˚C)
Capacity MBtuh
25HCR360C30 Outdoor Section With FC4DN (F,B)060 Indoor Section
KW
Tot a l
System
25HCR3C
Capacity MBtuh
tem KW
Tot a l Sy s -
75 (23.9) 85 (29.4) 95 (35) 105 (40.6) 115 (46.1) 125 (51.7)
Capacity MBtuh
Tot a l Sens Tot a l Sens To ta l Sens Tot al Sens Tot al Sens Tot al Sens
72 69.08 35.57 4.41 66.46 34.55 4.82 63.76 33.51 5.28 60.98 32.46 5.79 58.07 31.36 6.35 55.03 30.23 6.95
67 63.00 44.16 4.34 60.58 43.11 4.75 58.07 42.04 5.21 55.49 40.95 5.72 52.81 39.83 6.27 50.00 38.66 6.87
63 58.60 42.72 4.29 56.33 41.68 4.71 0.00 0.00 0.00 51.56 39.50 5.67 49.03 38.37 6.21 46.39 37.19 6.81
62 57.53 52.69 4.28 55.33 51.59 4.70 53.07 50.45 5.15 50.75 49.24 5.66 48.37 47.91 6.21 46.07 46.07 6.80
57 55.75 55.75 4.27 53.98 53.98 4.68 52.14 52.14 5.14 50.22 50.22 5.65 48.20 48.20 6.20 46.08 46.08 6.80
72 70.29 37.22 4.50 67.57 36.18 4.92 64.76 35.13 5.38 61.88 34.07 5.89 58.86 32.96 6.44 55.72 31.81 7.05
67 64.12 46.90 4.44 61.60 45.84 4.85 59.00 44.75 5.31 56.33 43.65 5.82 53.55 42.49 6.37 50.65 41.30 6.97
63 59.68 45.29 4.39 57.32 44.23 4.80 54.88 43.13 5.26 52.36 42.01 5.76 49.74 40.85 6.31 47.02 39.64 6.90
62 58.77 56.33 4.38 56.52 55.12 4.79 54.24 53.79 5.25 52.03 52.03 5.76 49.89 49.89 6.31 47.64 47.64 6.92
57 57.93 57.93 4.37 56.04 56.04 4.79 54.08 54.08 5.25 52.04 52.04 5.76 49.89 49.89 6.31 47.64 47.64 6.92
72 71.19 38.78 4.60 68.38 37.73 5.01 65.49 36.67 5.47 62.53 35.60 5.98 59.43 34.48 6.54 56.21 33.32 7.14
67 64.95 49.52 4.53 62.36 48.43 4.94 59.68 47.33 5.40 56.94 46.20 5.91 54.09 45.03 6.46 51.12 43.81 7.06
63 60.49 47.73 4.48 58.05 46.64 4.89 55.54 45.53 5.35 52.95 44.38 5.85 50.27 43.20 6.40 47.49 41.96 7.00
62 59.88 59.44 4.48 57.72 57.72 4.89 55.66 55.66 5.35 53.51 53.51 5.86 51.27 51.27 6.42 48.91 48.91 7.02
57 59.72 59.72 4.48 57.73 57.73 4.89 55.66 55.66 5.35 53.52 53.52 5.86 51.28 51.28 6.42 48.91 48.91 7.02
FK4DNB006 0.99 0.97
CAR**6024A** 0.98 0.98 58CV(A,X)155--- 22
CSRH*6012A** 0.97 0.97 58CV(A,X)135--- 22
CNRV*6024A** 0.97 0.97 58CV(A,X)155---22
CSRH*6012A** 0.98 0.97 58CV(A,X)155--- 22
CFM EWB
EVAPORATOR AIR
DETAILED COOLING CAPACITIES (CONT.)
1750
2000
2250
*FC4DN(F,B)060 1.00 1.00
Cooling Indoor Model Capacity Power Furnace Mo del
CNRH*6024A** 0.97 0.97 58CV(A,X)155--- 22
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80_F(27_C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80_F(27_C).
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240--- 94. If additional tubing length and/or indoor unit is located above outdoor unit, a slight variation in capacity may occur.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible ca pacities shown are based on 80_F(27_ C) entering air at the indoor coil. For sensible capacities at other than 80_F(27_C), deduct 835 Btuh
** System kw is total of indoor and outdoor unit kilowatts.
{{ At TVA rating indoor condition (75_F edb/63_F ewb). All other indoor a ir temperatures are at 80_F edb.
EWB — Entering Wet Bulb
23
Page 24
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR3C
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR318C Outdoor Section With FA4CN(F,C)018 In door Section
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
--- 3 ( --- 19 . 4 ) 7 ( ---13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE
EDB CFM
525 7.43 6.84 1.13 9.40 8.64 1.19 11.66 10.64 1.27 14.22 12.63 1.36 16.73 15.23 1.44 18.41 18.41 1.51 18.41 18.41 1.51 18.29 18.29 1.50
600 7.58 6.97 1.15 9.57 8.80 1.20 11.86 10.82 1.27 14.45 12.83 1.35 16.64 15.14 1.42 17.32 17.32 1.44 17.05 17.05 1.43 16.45 16.45 1.41
675 7.72 7.10 1.16 9.73 8.94 1.22 12.04 10.98 1.28 14.64 13.00 1.36 16.43 14.96 1.41 16.47 16.47 1.41 16.00 16.00 1.39 15.04 15.04 1.3670525 7.22 6.64 1.19 9.18 8.44 1.25 11.43 10.42 1.33 13.97 12.41 1.42 16.66 15.16 1.52 18.62 18.62 1.60 19.14 19.14 1.62 19.10 19.10 1.61
600 7.37 6.78 1.20 9.35 8.59 1.26 11.62 10.60 1.33 14.19 12.61 1.42 16.68 15.17 1.50 18.00 18.00 1.55 17.91 17.91 1.54 17.61 17.61 1.53
675 7.51 6.91 1.22 9.50 8.73 1.28 11.80 10.76 1.34 14.39 12.78 1.42 16.61 15.11 1.49 17.22 17.22 1.51 16.96 16.96 1.50 16.39 16.39 1.4875525 7.00 6.44 1.24 8.98 8.25 1.32 11.19 10.20 1.40 13.72 12.19 1.49 16.47 14.99 1.61 18.71 18.71 1.70 19.76 19.76 1.74 19.86 19.86 1.74
600 7.15 6.58 1.26 9.14 8.40 1.33 11.38 10.38 1.40 13.94 12.38 1.49 16.63 15.13 1.58 18.47 18.47 1.65 18.62 18.62 1.66 18.49 18.49 1.65
675 7.29 6.70 1.28 9.29 8.54 1.34 11.56 10.54 1.41 14.14 12.56 1.49 16.64 15.15 1.57 17.85 17.85 1.61 17.75 17.75 1.61 17.41 17.41 1.59
FF1ENE 018 1.00 1.00
FF1ENE 024 0.95 0.96
FK4DNF001 0.91 0.88
FC4DNF018 0.98 0.92
FC4DNF024 0.93 0.89
FA4CN(F,C)024 0.96 0.99
65
*FA4CN(F,C)018 1.00 1.00
Heating Indoor Model Capac ity Power Furnac e Mo del
FK4DNF002 0.91 0.85
CAR**2414A** 0.96 0.96
CAR**2417A** 0.96 0.96
CNRF*2418A** 0.97 0.95
CNRV*1814A** 0.99 0.97
CNRH*2417A** 0.97 0.95
CAR**1814A** 0.97 0.97 58CV(A,X)070---12
CNRV*2414A** 0.97 0.95
CAR**2414A** 0.95 0.91 58CV(A,X)070---12
CNRV*2417A** 0.97 0.95
CSRH*2412A** 0.89 0.91
CNRH*2417A** 0.97 0.90 58CV(A,X)070--- 12
CAR**2417A** 0.95 0.90 58CV(A,X)090---16
CNRV*1814A** 0.98 0.93 58CV(A,X)070---12
CNRV*2414A** 0.97 0.90 58CV(A,X)070---12
CSRH*2412A** 0.94 0.89 58CV(A,X)070---12
CNRV*2417A** 0.97 0.89 58CV(A,X)090---16
CNRH*2417A** 0.97 0.89 58CV(A,X)090--- 16
CAR**2417A** 0.95 0.91 58MVB060---14
CSRH*2412A** 0.93 0.88 58CV(A,X)090---16
CSRH*2412A** 0.93 0.89 58MVB040--- 14
CNRH*2417A** 0.97 0.90 58MVB040---14
CNRV*2417A** 0.97 0.90 58MVB060 --- 14
CNRH*2417A** 0.97 0.90 58MVB060---14
CAR**2417A** 0.95 0.91 58UVB060---14
CSRH*2412A** 0.93 0.89 58MVB060--- 14
CSRH*2412A** 0.93 0.89 58MVB080--- 14
CNRV*2417A** 0.97 0.90 58UVB060---14
CNRH*2417A** 0.97 0.90 58MVB080---14
See notes on page 30
24
Page 25
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
CNRV*2417A** 0.99 0.94 58UVB060--- 14
CNRV*3017A** 0.98 0.93 58UVB060--- 14
Heating Indoor Model Capacity Power Fur nace Mode l
See notes on page 30
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR3C
Capacity MBtuh
tem
Sys-
KW†
Tot a l
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR324C Outdoor Section With FA4CN(F,C)024 In door Section
CAR**2417A** 0.99 0.95 58MVB060--- 14
CSRH*2412A** 0.99 0.94 58CV(A,X)110---20
CSRH*3012A** 0.98 0.93 58CV(A,X)110---20
CSRH*2412A** 0.99 0.94 58CV(A,X)135---22
CSRH*3012A** 0.98 0.93 58CV(A,X)135---22
CSRH*2412A** 0.99 0.94 58CV(A,X)155---22
CNRH*2417A** 0.99 0.94 58CV(A,X)135--- 22
Heating Indoor Model Capacity Power Fur nace Mode l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
CNRH*3017A** 0.98 0.93 58CV(A,X)135--- 22
CSRH*3012A** 0.98 0.93 58CV(A,X)155---22
CNRH*2417A** 0.99 0.93 58CV(A,X)155--- 22
CNRH*3017A** 0.98 0.93 58CV(A,X)155--- 22
CNRH*2417A** 0.99 0.94 58MVB040--- 14
CNRH*3017A** 0.98 0.93 58MVB040--- 14
CAR**3017A** 0.98 0.94 58MVB060--- 14
CSRH*2412A** 1.00 0.95 58MVB040---14
CSRH*3012A** 0.98 0.93 58MVB040---14
CNRV*2417A** 0.99 0.94 58MVB060---14
CNRV*3017A** 0.98 0.93 58MVB060---14
CSRH*2412A** 0.99 0.94 58MVB060---14
CSRH*3012A** 0.98 0.93 58MVB060---14
CSRH*2412A** 0.99 0.94 58MVB080---14
CSRH*3012A** 0.98 0.93 58MVB080---14
CSRH*2412A** 0.99 0.94 58MVB080---20
CSRH*3012A** 0.98 0.93 58MVB080---20
CSRH*2412A** 0.99 0.93 58MVB100---20
CNRH*2417A** 0.99 0.94 58MVB060--- 14
CNRH*3017A** 0.98 0.93 58MVB060--- 14
CNRH*2417A** 0.99 0.94 58MVB080--- 14
CNRH*3017A** 0.98 0.93 58MVB080--- 14
CNRH*2417A** 0.99 0.94 58MVB080--- 20
CNRH*3017A** 0.98 0.93 58MVB080--- 20
CSRH*3012A** 0.98 0.93 58MVB100---20
CNRH*2417A** 0.99 0.93 58MVB100--- 20
CNRH*3017A** 0.98 0.93 58MVB100--- 20
CNRH*2417A** 0.99 0.95 58MVB120--- 20
CAR**2417A** 0.99 0.95 58UVB060---14
CAR**3017A** 0.98 0.94 58UVB060---14
CSRH*2412A** 0.99 0.95 58MVB120---20
CSRH*3012A** 0.98 0.94 58MVB120---20
CNRH*3017A** 0.98 0.94 58MVB120--- 20
--- 3 ( --- 19 . 4 ) 7 ( ---13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
700 9.44 8.68 1.55 11.81 10.85 1.61 14.36 13.10 1.68 17.25 15.32 1.76 20.46 18.61 1.86 23.99 23.99 1.98 27.61 27.61 2.10 31.25 31.25 2.23
800 9.61 8.85 1.57 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 20.73 18.87 1.84 24.32 24.32 1.96 27.53 27.53 2.04 30.88 30.88 2.16
900 9.78 9.00 1.59 12.17 11.18 1.64 14.77 13.47 1.69 17.71 15.73 1.76 20.97 19.08 1.84 24.46 24.46 1.93 27.30 27.30 2.02 30.39 30.39 2.1270700 9.17 8.43 1.61 11.57 10.63 1.69 14.13 12.89 1.76 16.99 15.09 1.84 20.17 18.36 1.95 23.67 23.67 2.08 27.42 27.42 2.21 31.11 31.11 2.35
800 9.35 8.60 1.63 11.76 10.81 1.70 14.34 13.07 1.76 17.23 15.30 1.84 20.45 18.61 1.93 24.00 24.00 2.05 27.46 27.46 2.15 30.88 30.88 2.28
900 9.51 8.75 1.66 11.93 10.97 1.72 14.52 13.24 1.77 17.45 15.49 1.84 20.69 18.83 1.93 24.25 24.25 2.04 27.33 27.33 2.12 30.52 30.52 2.2375700 8.87 8.16 1.68 11.31 10.39 1.76 13.90 12.67 1.84 16.72 14.85 1.93 19.86 18.07 2.04 23.36 23.36 2.17 27.20 27.20 2.34 30.95 30.95 2.47
800 9.06 8.33 1.70 11.51 10.57 1.78 14.11 12.86 1.85 16.96 15.06 1.92 20.17 18.35 2.03 23.68 23.68 2.15 27.32 27.32 2.26 30.82 30.82 2.39
900 9.22 8.49 1.73 11.68 10.74 1.80 14.29 13.03 1.86 17.18 15.26 1.93 20.40 18.57 2.02 23.95 23.95 2.14 27.30 27.30 2.23 30.56 30.56 2.35
FF1ENE 024 1.00 1.00
FF1ENE 030 1.00 1.00
FK4DNF001 0.99 0.95
FC4DNF024 1.00 0.95
FC4DNF030 1.00 0.93
FA4CN(F,C)030 1.00 0.98
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE (CONT.)
EDB CFM
65
*FA4CN(F,C)024 1.00 1.00
Heating Indoor Model Capacity Power Fur nace Mode l
FK4DNF002 0.99 0.92
CAR**2414A** 1.00 0.98
CAR**2417A** 1.00 0.98
CAR**3014A** 1.00 0.99
FK4DN(B,F)003 0.98 0.91
CAR**3017A** 1.00 0.99
CNRF*2418A** 1.00 0.96
CNRV*2414A** 1.00 0.96
CNRV*2417A** 1.00 0.96
CNRH*2417A** 1.00 0.96
CNRV*3014A** 1.00 0.99
CNRH*3017A** 1.00 0.99
CAR**2414A** 0.99 0.96 58CV(A,X)070---12
CNRV*3017A** 1.00 0.99
CAR**3014A** 0.98 0.94 58CV(A,X)070---12
CSRH*2412A** 1.00 0.96
CSRH*3012A** 1.00 0.99
CNRV*2414A** 0.99 0.94 58CV(A,X)070---12
CNRH*2417A** 0.99 0.94 58CV(A,X)070--- 12
CNRH*3017A** 0.98 0.94 58CV(A,X)070--- 12
CAR**2417A** 0.98 0.94 58CV(A,X)090---16
CNRV*3014A** 0.98 0.94 58CV(A,X)070---12
CAR**3017A** 0.98 0.93 58CV(A,X)090---16
CSRH*2412A** 0.99 0.94 58CV(A,X)070---12
CSRH*3012A** 0.98 0.94 58CV(A,X)070---12
CNRV*2417A** 0.99 0.93 58CV(A,X)090---16
CNRV*3017A** 0.98 0.93 58CV(A,X)090---16
CSRH*2412A** 0.99 0.93 58CV(A,X)090---16
CNRH*2417A** 0.99 0.93 58CV(A,X)090--- 16
CNRH*3017A** 0.98 0.93 58CV(A,X)090--- 16
CSRH*3012A** 0.98 0.93 58CV(A,X)090---16
CNRH*2417A** 0.99 0.94 58CV(A,X)110--- 20
CNRH*3017A** 0.98 0.93 58CV(A,X)110--- 20
25
Page 26
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR3C
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Heating Indoor
Capacity Power Fur nace Model
Model
CAR**3617A** 0.98 1.00 58MVB060---14
CNRV*3017A** 0.99 1.01 58MVB060 --- 14
CNRV*3617A** 0.99 1.01 58MVB060 --- 14
CSRH*3012A** 0.98 1.00 58MVB060--- 14
CNRH*3017A** 0.99 1.01 58MVB060---14
CNRH*3617A** 0.99 1.01 58MVB060---14
CSRH*3612A** 0.96 0.96 58MVB060--- 14
CNRH*3017A** 0.99 1.00 58MVB080---14
CNRH*3617A** 0.99 1.00 58MVB080---14
CAR**3621A** 0.97 0.99 58MVB080---20
CNRV*3621A** 0.99 1.00 58MVB080 --- 14
CSRH*3012A** 0.98 1.00 58MVB080--- 14
CSRH*3612A** 0.96 0.96 58MVB080--- 14
CNRH*3017A** 0.99 1.00 58MVB080---20
CNRH*3617A** 0.99 1.00 58MVB080---20
CAR**3621A** 0.97 0.98 58MVB100---20
CNRV*3621A** 0.99 1.00 58MVB080 --- 20
CSRH*3012A** 0.98 1.00 58MVB080--- 20
CSRH*3612A** 0.96 0.96 58MVB080--- 20
CNRV*3621A** 0.98 0.99 58MVB100 --- 20
CSRH*3012A** 0.98 1.00 58MVB100--- 20
CNRH*3017A** 0.98 0.99 58MVB100---20
CSRH*3612A** 0.96 0.96 58MVB100--- 20
CNRH*3617A** 0.98 0.99 58MVB100---20
CNRH*3017A** 0.98 1.00 58MVB120---20
CAR**3017A** 0.99 1.01 58UVB060--- 14
CAR**3617A** 0.98 1.00 58UVB060--- 14
CAR**3621A** 0.97 0.99 58UVB080--- 20
CSRH*3012A** 0.98 1.00 58MVB120--- 20
CSRH*3612A** 0.96 0.96 58MVB120--- 20
CNRH*3617A** 0.98 1.00 58MVB120---20
CAR**3621A** 0.97 0.98 58UVB100--- 20
CNRV*3017A** 0.99 1.01 58UVB060---14
CNRV*3617A** 0.99 1.01 58UVB060---14
CNRV*3621A** 0.99 1.00 58UVB080---14
CNRV*3621A** 0.99 1.00 58UVB080---20
CNRV*3621A** 0.98 0.99 58UVB100---20
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR330C Outdoor Section With FC4DNF030 Indoor Section
See notes on page 30
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
--- 3 ( --- 19 . 4 ) 7 ( ---13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
875 11.89 10.94 1.96 14.83 13.62 2.04 18.00 16.41 2.12 21.53 19.12 2.22 25.45 23.16 2.35 29.01 29.01 2.43 32.46 32.46 2.55 35.99 35.99 2.68
875 11.56 10.63 2.05 14.54 13.36 2.14 17.71 16.15 2.22 21.21 18.84 2.32 25.11 22.85 2.46 28.92 28.92 2.56 32.44 32.44 2.68 36.08 36.08 2.83
1000 12.06 11.09 1.97 15.00 13.79 2.04 18.21 16.60 2.10 21.77 19.33 2.20 25.67 23.36 2.29 28.78 28.78 2.37 32.01 32.01 2.47 34.95 34.95 2.57
1125 12.21 11.23 1.98 15.16 13.93 2.04 18.39 16.77 2.10 21.97 19.51 2.18 25.67 23.36 2.26 28.53 28.53 2.33 31.50 31.50 2.42 32.77 32.77 2.45
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE (CONT.)
EDB CFM
65
875 11.20 10.30 2.13 14.23 13.08 2.23 17.43 15.89 2.33 20.89 18.55 2.43 24.78 22.55 2.58 28.90 28.90 2.70 32.36 32.36 2.82 36.10 36.10 2.98
1000 11.73 10.79 2.05 14.72 13.53 2.13 17.91 16.33 2.21 21.46 19.06 2.30 25.39 23.10 2.42 28.80 28.80 2.49 32.09 32.09 2.60 35.38 35.38 2.72
1125 11.88 10.93 2.07 14.88 13.67 2.13 18.09 16.49 2.20 21.66 19.24 2.29 25.57 23.27 2.38 28.60 28.60 2.46 31.69 31.69 2.55 33.95 33.95 2.62
1000 11.38 10.47 2.14 14.42 13.25 2.23 17.63 16.08 2.31 21.13 18.77 2.41 25.05 22.80 2.54 28.76 28.76 2.63 32.11 32.11 2.74 35.53 35.53 2.87
70
75
Capacity Power Fur nace Model
1125 11.53 10.61 2.15 14.58 13.40 2.23 17.81 16.23 2.31 21.34 18.95 2.39 25.28 23.00 2.51 28.63 28.63 2.58 31.80 31.80 2.69 34.90 34.90 2.79
Model
Heating Indoor
FK4DNF001 1.00 1.02
*FC4DNF030 1.00 1.00
FK4DNF002 1.00 0.98
FC4DN(F,B)036 0.97 1.00
CAR**3014A** 0.99 1.01 58CV(A,X)070--- 12
FK4DN(B,F)003 0.97 0.97
CAR**3614A** 0.98 1.00 58CV(A,X)070--- 12
CNRH*3017A** 0.99 1.01 58CV(A,X)070---12
CNRH*3617A** 0.99 1.01 58CV(A,X)070---12
CAR**3017A** 0.98 0.99 58CV(A,X)090--- 16
CNRV*3014A** 0.99 1.01 58CV(A,X)070---12
CAR**3617A** 0.97 0.98 58CV(A,X)090--- 16
CSRH*3012A** 0.98 1.00 58CV(A,X)070---12
CSRH*3612A** 0.96 0.96 58CV(A,X)070---12
CNRV*3017A** 0.98 0.99 58CV(A,X)090---16
CNRH*3017A** 0.98 0.99 58CV(A,X)090---16
CNRH*3617A** 0.98 0.99 58CV(A,X)090---16
CAR**3621A** 0.97 0.98 58CV(A,X)110--- 20
CNRV*3617A** 0.98 0.99 58CV(A,X)090---16
CSRH*3012A** 0.98 0.99 58CV(A,X)090---16
CSRH*3612A** 0.96 0.96 58CV(A,X)090---16
CNRV*3621A** 0.98 0.99 58CV(A,X)110---20
CSRH*3012A** 0.98 0.99 58CV(A,X)110---20
CSRH*3612A** 0.95 0.95 58CV(A,X)110---20
CSRH*3012A** 0.98 0.99 58CV(A,X)135---22
CSRH*3612A** 0.95 0.95 58CV(A,X)135---22
CSRH*3012A** 0.98 0.99 58CV(A,X)155---22
CNRH*3017A** 0.98 0.99 58CV(A,X)110---20
CNRH*3617A** 0.98 0.99 58CV(A,X)110---20
CNRH*3017A** 0.98 0.99 58CV(A,X)135---22
CNRH*3617A** 0.98 0.99 58CV(A,X)135---22
CSRH*3612A** 0.95 0.95 58CV(A,X)155---22
CNRH*3017A** 0.98 0.99 58CV(A,X)155---22
CNRH*3617A** 0.98 0.99 58CV(A,X)155---22
CNRH*3017A** 0.99 1.01 58MVB040---14
CAR**3017A** 0.99 1.01 58MVB060---14
CSRH*3012A** 0.98 1.00 58MVB040--- 14
CSRH*3612A** 0.96 0.97 58MVB040--- 14
CNRH*3617A** 0.99 1.01 58MVB040---14
26
Page 27
tem KW†
Tot a l S ys -
Capacity MBtuh
tem KW†
Tot a l S ys -
Capacity MBtuh
tem KW†
Tot a l S ys -
CAR**4224A** 0.99 0.98 58UVB120---20
CNRV*3621A** 1.01 1.02 58UVB100--- 20
CNRV*4221A** 0.99 0.98 58UVB100--- 20
Heating Indoor Model Capa city Power Furnace Mod el
See notes on page 30
Capacity MBtuh
tem KW†
Tot a l S ys -
25HCR3C
Capacity MBtuh
tem KW†
Tot a l S ys -
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem KW†
Tot a l S ys -
25HCR336C30 Outdoor Section With FC4DN(F,B)036 Indoor Section
Heating Indoor Model Capa city Power Furnace Mod el
Capacity MBtuh
tem KW†
Tot a l S ys -
Capacity MBtuh
tem KW†
Tot a l S ys -
CAR**3621A** 1.01 1.02 58MVB080---14
CNRV*3617A** 1.01 1.02 58MVB060---14
CAR**4221A** 1.00 1.00 58MVB080---14
CSRH*3612A** 0.98 0.97 58MVB060---14
CSRH*4212A** 0.97 0.95 58MVB060---14
CNRH*4221A** 1.00 0.99 58MVB080---14
CAR**3621A** 1.01 1.01 58MVB080---20
CNRV*4221A** 1.00 0.99 58MVB080---14
CAR**4221A** 1.00 1.00 58MVB080---20
CSRH*3612A** 0.99 0.99 58MVB080---14
CSRH*4212A** 0.97 0.97 58MVB080---14
CNRV*3621A** 1.01 1.02 58MVB080---20
CNRH*3617A** 1.01 1.02 58MVB080---20
CNRH*4221A** 0.99 0.98 58MVB080---20
CAR**3621A** 1.01 1.01 58MVB100---20
CNRV*4221A** 0.99 0.98 58MVB080---20
CAR**4221A** 1.00 0.99 58MVB100---20
CSRH*3612A** 0.98 0.97 58MVB080---20
CSRH*4212A** 0.97 0.95 58MVB080---20
CNRV*3621A** 1.01 1.02 58MVB100---20
CNRH*3617A** 1.01 1.02 58MVB100---20
CNRH*4221A** 0.99 0.98 58MVB100---20
CAR**4224A** 0.99 0.98 58MVB120---20
CNRV*4221A** 0.99 0.98 58MVB100---20
CSRH*3612A** 0.98 0.97 58MVB100---20
CSRH*4212A** 0.97 0.95 58MVB100---20
CNRH*3617A** 1.01 1.02 58MVB120---20
CAR**3617A** 1.01 1.01 58UVB060---14
CAR**3621A** 1.01 1.02 58UVB080---14
CAR**4221A** 1.00 1.00 58UVB080---14
CAR**3621A** 1.01 1.01 58UVB080---20
CAR**4221A** 1.00 1.00 58UVB080---20
CAR**3621A** 1.01 1.01 58UVB100---20
CSRH*3612A** 0.98 0.97 58MVB120---20
CSRH*4212A** 0.97 0.95 58MVB120---20
CNRV*3617A** 1.01 1.02 58UVB060--- 14
CNRH*4221A** 0.99 0.97 58MVB120---20
CNRV*4221A** 1.00 0.99 58UVB080--- 14
CAR**4221A** 1.00 0.99 58UVB100---20
CNRV*3621A** 1.01 1.02 58UVB080--- 20
CNRV*4221A** 0.99 0.98 58UVB080--- 20
--- 3 ( --- 19 . 4 ) 7 ( --- 13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
1050 15.00 13.80 2.30 18.51 17.01 2.40 22.45 20.47 2.52 26.85 23.85 2.68 31.67 28.82 2.84 35.35 35.35 2.97 39.39 39.39 3.14 41.38 41.38 3.22
1200 15.19 13.97 2.31 18.73 17.21 2.40 22.70 20.69 2.52 27.13 24.09 2.67 31.46 28.63 2.79 34.88 34.88 2.92 37.68 37.68 3.03 38.03 38.03 3.03
1350 15.37 14.14 2.33 18.92 17.39 2.41 22.91 20.89 2.52 27.37 24.31 2.67 31.15 28.35 2.77 34.37 34.37 2.88 35.27 35.27 2.91 35.72 35.72 2.92701050 14.67 13.50 2.39 18.22 16.74 2.51 22.12 20.17 2.63 26.49 23.52 2.80 31.32 28.50 2.99 35.45 35.45 3.12 39.57 39.57 3.30 42.44 42.44 3.43
1200 14.86 13.67 2.41 18.42 16.93 2.51 22.37 20.39 2.63 26.76 23.77 2.78 31.52 28.68 2.93 35.00 35.00 3.06 38.80 38.80 3.22 39.67 39.67 3.25
1350 15.04 13.84 2.42 18.60 17.09 2.52 22.57 20.58 2.63 26.99 23.97 2.78 31.29 28.47 2.90 34.58 34.58 3.03 36.93 36.93 3.12 37.20 37.20 3.12751050 14.32 13.17 2.49 17.88 16.43 2.62 21.77 19.85 2.75 26.10 23.18 2.92 30.91 28.13 3.13 35.47 35.47 3.28 39.61 39.61 3.47 43.96 43.96 3.68
1200 14.52 13.36 2.50 18.09 16.63 2.62 22.01 20.07 2.74 26.40 23.45 2.90 31.25 28.44 3.08 35.14 35.14 3.21 38.99 38.99 3.38 41.08 41.08 3.47
1350 14.70 13.52 2.52 18.28 16.80 2.63 22.23 20.27 2.74 26.63 23.65 2.90 31.36 28.54 3.05 34.75 34.75 3.17 38.21 38.21 3.32 38.89 38.89 3.33
FK4DNF002 1.04 1.01
FK4DNF003 1.00 0.99
FC4DN(F,B)042 0.92 0.93
CAR**3614A** 0.98 1.00 58CV(A,X)070--- 12
*FC4DN(F,B)036 1.00 1.00
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE (CONT.)
EDB CFM
65
Heating Indoor Model Capa city Power Furnace Mod el
CNRH*3617A** 1.02 1.03 58CV(A,X)070---12
CAR**3617A** 1.01 1.01 58CV(A,X)090--- 16
CSRH*3612A** 0.98 0.98 58CV(A,X)070---12
CSRH*4212A** 0.97 0.96 58CV(A,X)070---12
CNRH*4221A** 1.00 0.99 58CV(A,X)070---12
CNRH*3617A** 1.01 1.01 58CV(A,X)090---16
CNRH*4221A** 0.99 0.97 58CV(A,X)090---16
CAR**3621A** 1.01 1.00 58CV(A,X)110--- 20
CNRV*3617A** 1.01 1.01 58CV(A,X)090--- 16
CAR**4221A** 0.99 0.98 58CV(A,X)110--- 20
CSRH*3612A** 0.98 0.97 58CV(A,X)090---16
CSRH*4212A** 0.97 0.95 58CV(A,X)090---16
CNRV*3621A** 1.01 1.01 58CV(A,X)110--- 20
CNRH*3617A** 1.01 1.01 58CV(A,X)110---20
CNRH*4221A** 0.99 0.97 58CV(A,X)110---20
CAR**4224A** 0.99 0.98 58CV(A,X)135--- 22
CNRV*4221A** 0.99 0.97 58CV(A,X)110--- 20
CSRH*3612A** 0.98 0.96 58CV(A,X)110---20
CSRH*4212A** 0.96 0.94 58CV(A,X)110---20
CNRH*3617A** 1.01 1.01 58CV(A,X)135---22
CAR**4224A** 0.99 0.97 58CV(A,X)155--- 22
CSRH*3612A** 0.98 0.96 58CV(A,X)135---22
CSRH*4212A** 0.96 0.94 58CV(A,X)135---22
CNRH*4221A** 0.99 0.96 58CV(A,X)135---22
CNRH*3617A** 1.01 1.01 58CV(A,X)155---22
CAR**4224A** 1.00 1.00 58MVB040---14
CSRH*3612A** 0.98 0.95 58CV(A,X)155---22
CSRH*4212A** 0.96 0.93 58CV(A,X)155---22
CNRH*4221A** 0.99 0.96 58CV(A,X)155---22
CNRH*3617A** 1.01 1.03 58MVB040---14
CAR**3617A** 1.01 1.01 58MVB060---14
CSRH*3612A** 0.99 0.98 58MVB040---14
CSRH*4212A** 0.97 0.97 58MVB040---14
CNRH*4221A** 1.00 0.99 58MVB040---14
CNRH*3617A** 1.01 1.02 58MVB060---14
CNRH*4221A** 0.99 0.98 58MVB060---14
27
Page 28
25HCR3C
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
CAR**4817A** 0.99 0.99 58UVB060---14
CAR**4221A** 0.99 1.05 58UVB080---14
CAR**4821A** 0.99 1.01 58UVB080---14
CAR**4221A** 0.99 1.04 58UVB080---20
CAR**4821A** 0.99 1.00 58UVB080---20
CAR**4221A** 0.99 1.04 58UVB100---20
CAR**4821A** 0.99 0.99 58UVB100---20
CAR**4224A** 0.99 1.03 58UVB120---20
CNRV*4221A** 0.99 1.05 58UVB080---14
CNRV*4821A** 1.00 1.02 58UVB080---14
CNRV*4221A** 0.99 1.04 58UVB080---20
Heating Indoor Model Capac ity Power Furnac e Mo del
Capacity MBtuh
tem
Sys-
KW†
Tot a l
CNRV*4821A** 1.00 1.01 58UVB080---20
CAR**4824A** 0.99 0.99 58UVB120---20
CNRV*4221A** 0.99 1.04 58UVB100---20
CNRV*4821A** 0.99 0.99 58UVB100---20
CNRV*4824A** 0.99 0.99 58UVB120---20
See notes on page 30
Capacity MBtuh
tem
Sys-
KW†
Tot a l
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR342C Outdoor Section With FC4DN(F,B)042 Indoor Section
CNRH*4821A** 1.00 1.02 58MVB040---14
Heating Indoor Model Capac ity Power Furnac e Mo del
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
CNRH*4221A** 0.99 1.04 58MVB060---14
CAR**4817A** 0.99 0.99 58MVB060---14
CNRV*4824A** 1.00 1.02 58MVB040 --- 14
CSRH*4212A** 1.00 1.02 58MVB040--- 14
CSRH*4812A** 1.00 1.01 58MVB040--- 14
CAR**4221A** 0.99 1.05 58MVB080---14
CAR**4821A** 0.99 1.01 58MVB080---14
CSRH*4212A** 1.00 1.01 58MVB060--- 14
CSRH*4812A** 1.00 1.00 58MVB060--- 14
CNRH*4821A** 0.99 1.00 58MVB060---14
CNRV*4221A** 0.99 1.05 58MVB080 --- 14
CNRH*4221A** 0.99 1.05 58MVB080---14
CNRH*4821A** 1.00 1.02 58MVB080---14
CAR**4221A** 0.99 1.04 58MVB080---20
CNRV*4821A** 1.00 1.02 58MVB080 --- 14
CAR**4821A** 0.99 1.00 58MVB080---20
CSRH*4212A** 1.00 1.02 58MVB080--- 14
CSRH*4812A** 1.00 1.01 58MVB080--- 14
CNRV*4221A** 0.99 1.04 58MVB080 --- 20
CNRH*4221A** 0.99 1.04 58MVB080---20
CNRH*4821A** 1.00 1.01 58MVB080---20
CAR**4221A** 0.99 1.04 58MVB100---20
CNRV*4821A** 1.00 1.01 58MVB080 --- 20
CAR**4821A** 0.99 0.99 58MVB100---20
CSRH*4212A** 1.00 1.01 58MVB080--- 20
CSRH*4812A** 1.00 1.00 58MVB080--- 20
CNRV*4221A** 0.99 1.04 58MVB100 --- 20
CNRH*4221A** 0.99 1.04 58MVB100---20
CNRH*4821A** 0.99 0.99 58MVB100---20
CAR**4224A** 0.99 1.03 58MVB120---20
CNRV*4821A** 0.99 0.99 58MVB100 --- 20
CAR**4824A** 0.99 0.99 58MVB120---20
CSRH*4212A** 1.00 1.01 58MVB100--- 20
CSRH*4812A** 1.00 1.00 58MVB100--- 20
CNRV*4824A** 0.99 0.99 58MVB120 --- 20
CSRH*4212A** 0.99 1.00 58MVB120--- 20
CNRH*4221A** 0.99 1.04 58MVB120---20
CSRH*4812A** 0.99 0.99 58MVB120--- 20
CNRH*4821A** 0.99 0.99 58MVB120---20
--- 3 ( --- 19 . 4 ) 7 ( ---13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
1225 16.64 15.31 2.55 20.57 18.90 2.66 24.79 22.60 2.77 29.49 26.19 2.91 34.78 31.65 3.07 40.64 40.64 3.24 46.44 46.44 3.43 52.63 52.63 3.66
1400 16.88 15.53 2.57 20.82 19.13 2.67 25.06 22.85 2.77 29.83 26.49 2.90 35.16 32.00 3.05 40.77 40.77 3.18 46.21 46.21 3.35 49.85 49.85 3.47
1575 17.10 15.74 2.60 21.04 19.34 2.69 25.32 23.09 2.78 30.12 26.75 2.90 35.50 32.30 3.04 40.70 40.70 3.16 45.87 45.87 3.31 46.03 46.03 3.30701225 16.28 14.98 2.66 20.24 18.60 2.78 24.48 22.32 2.90 29.11 25.85 3.04 34.36 31.27 3.21 40.15 40.15 3.40 46.17 46.17 3.59 52.13 52.13 3.82
1400 16.52 15.20 2.68 20.49 18.83 2.79 24.75 22.57 2.89 29.44 26.14 3.02 34.74 31.61 3.18 40.50 40.50 3.33 46.05 46.05 3.51 50.87 50.87 3.68
1575 16.73 15.39 2.71 20.72 19.04 2.81 24.99 22.79 2.90 29.73 26.40 3.03 35.06 31.91 3.18 40.54 40.54 3.30 45.83 45.83 3.47 48.36 48.36 3.54751225 15.86 14.59 2.76 19.89 18.28 2.90 24.16 22.03 3.03 28.73 25.52 3.18 33.89 30.84 3.35 39.65 39.65 3.57 45.89 45.89 3.76 51.79 51.79 4.00
1400 16.11 14.82 2.79 20.16 18.53 2.91 24.43 22.28 3.02 29.05 25.81 3.16 34.32 31.23 3.33 40.10 40.10 3.49 45.83 45.83 3.67 51.85 51.85 3.90
1575 16.34 15.03 2.82 20.39 18.74 2.93 24.68 22.50 3.03 29.34 26.06 3.16 34.64 31.52 3.32 40.32 40.32 3.45 45.68 45.68 3.62 49.50 49.50 3.75
FK4DNB006 0.92 0.91
FC4DN(F,B)048 0.98 0.95
FK4DN(B,F)003 0.98 1.03
FK4DN(B,F)005 0.96 0.95
CSRH*4812A** 1.01 1.02
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE (CONT.)
EDB CFM
65
*FC4DN(F,B)042 1.00 1.00
Heating Indoor Model Capac ity Power Furnac e Mo del
CNRH*4221A** 0.99 1.05 58CV(A,X)070--- 12
CAR**4817A** 0.98 0.97 58CV(A,X)090---16
CSRH*4212A** 1.00 1.02 58CV(A,X)070---12
CSRH*4812A** 1.00 1.01 58CV(A,X)070---12
CNRH*4821A** 1.00 1.02 58CV(A,X)070--- 12
CNRH*4221A** 0.99 1.03 58CV(A,X)090--- 16
CAR**4221A** 0.99 1.03 58CV(A,X)110---20
CAR**4821A** 0.99 0.98 58CV(A,X)110---20
CSRH*4212A** 0.99 0.99 58CV(A,X)090---16
CSRH*4812A** 0.99 0.98 58CV(A,X)090---16
CNRH*4821A** 0.99 0.99 58CV(A,X)090--- 16
CNRV*4221A** 0.99 1.03 58CV(A,X)110---20
CNRH*4221A** 0.99 1.03 58CV(A,X)110--- 20
CNRH*4821A** 0.99 0.98 58CV(A,X)110--- 20
CAR**4224A** 0.98 1.01 58CV(A,X)135---22
CNRV*4821A** 0.99 0.98 58CV(A,X)110---20
CAR**4824A** 0.99 0.98 58CV(A,X)135---22
CSRH*4212A** 1.00 1.00 58CV(A,X)110---20
CSRH*4812A** 1.00 0.99 58CV(A,X)110---20
CNRH*4221A** 0.99 1.02 58CV(A,X)135--- 22
CNRH*4821A** 0.99 0.98 58CV(A,X)135--- 22
CAR**4224A** 0.98 1.01 58CV(A,X)155---22
CNRV*4824A** 0.99 0.98 58CV(A,X)135---22
CAR**4824A** 0.99 0.98 58CV(A,X)155---22
CSRH*4212A** 0.99 0.98 58CV(A,X)135---22
CSRH*4812A** 0.99 0.97 58CV(A,X)135---22
CNRH*4221A** 0.99 1.02 58CV(A,X)155--- 22
CNRH*4821A** 0.99 0.98 58CV(A,X)155--- 22
CAR**4224A** 0.99 1.05 58MVB040---14
CNRV*4824A** 0.99 0.98 58CV(A,X)155---22
CAR**4824A** 0.99 1.00 58MVB040---14
CSRH*4212A** 0.99 0.98 58CV(A,X)155---22
CSRH*4812A** 0.99 0.97 58CV(A,X)155---22
CNRH*4221A** 0.99 1.05 58MVB040---14
28
Page 29
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR348C30 Outdoor Section With FC4DN(F,B)048 Indoor Section
Heating Indoor
Capacity Power Fur nace Mode l
Model
CAR**4821A** 0.98 1.02 58MVB100---20
CAR**6021A** 0.98 1.02 58MVB100---20
CNRH*4821A** 0.98 1.02 58MVB100---20
CNRH*6024A** 0.98 1.02 58MVB100---20
CAR**4824A** 0.98 1.02 58MVB120---20
CNRV*4821A** 0.98 1.02 58MVB100--- 20
CAR**6024A** 0.98 1.02 58MVB120---20
CSRH*4812A** 0.98 1.02 58MVB100---20
CSRH*6012A** 0.98 1.00 58MVB100---20
CNRV*4824A** 0.98 1.02 58MVB120--- 20
CNRH*4821A** 0.98 1.02 58MVB120---20
CNRH*6024A** 0.98 1.02 58MVB120---20
CAR**4821A** 0.98 1.03 58UVB080--- 20
CAR**6021A** 0.98 1.02 58UVB080--- 20
CAR**4821A** 0.98 1.02 58UVB100--- 20
CAR**6021A** 0.98 1.02 58UVB100--- 20
CAR**4824A** 0.98 1.02 58UVB120--- 20
CNRV*6024A** 0.98 1.02 58MVB120--- 20
CSRH*4812A** 0.98 1.02 58MVB120---20
CSRH*6012A** 0.98 1.00 58MVB120---20
CNRV*4821A** 0.98 1.03 58UVB080 --- 20
CAR**6024A** 0.98 1.02 58UVB120--- 20
CNRV*4821A** 0.98 1.02 58UVB100 --- 20
CNRV*4824A** 0.98 1.02 58UVB120 --- 20
CNRV*6024A** 0.98 1.02 58UVB120 --- 20
25HCR3C
See notes on page 30
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
--- 3 ( --- 19 . 4 ) 7 ( ---13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
1400 19.51 17.95 3.08 24.04 22.09 3.22 29.05 26.49 3.37 34.70 30.82 3.55 41.06 37.36 3.78 48.15 48.15 4.05 56.11 56.11 4.33 63.47 63.47 4.64
1600 19.80 18.21 3.10 24.33 22.36 3.23 29.39 26.80 3.37 35.08 31.15 3.56 41.49 37.76 3.76 48.59 48.59 4.02 55.54 55.54 4.23 62.05 62.05 4.51
1800 20.05 18.45 3.14 24.59 22.60 3.25 29.69 27.07 3.39 35.45 31.48 3.55 41.82 38.06 3.76 48.80 48.80 3.96 54.86 54.86 4.19 58.16 58.16 4.31701400 19.06 17.54 3.20 23.66 21.74 3.36 28.62 26.10 3.53 34.25 30.42 3.72 40.52 36.88 3.95 47.51 47.51 4.23 55.50 55.50 4.57 63.51 63.51 4.87
1600 19.35 17.80 3.23 23.95 22.01 3.37 28.96 26.41 3.52 34.63 30.75 3.70 40.98 37.29 3.93 48.00 48.00 4.20 55.54 55.54 4.43 62.59 62.59 4.75
1800 19.61 18.05 3.26 24.22 22.26 3.40 29.27 26.68 3.54 34.97 31.06 3.71 41.31 37.59 3.92 48.40 48.40 4.17 54.97 54.97 4.39 60.46 60.46 4.63751400 18.56 17.08 3.32 23.24 21.36 3.51 28.20 25.71 3.68 33.75 29.97 3.89 39.98 36.39 4.13 46.92 46.92 4.42 54.74 54.74 4.79 63.08 63.08 5.09
1600 18.86 17.35 3.35 23.55 21.64 3.52 28.53 26.01 3.68 34.13 30.31 3.87 40.45 36.81 4.10 47.43 47.43 4.38 55.28 55.28 4.67 62.33 62.33 4.96
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE (CONT.)
EDB CFM
65
Capacity Power Fur nace Mode l
1800 19.13 17.60 3.39 23.82 21.89 3.54 28.83 26.29 3.69 34.47 30.61 3.87 40.84 37.16 4.10 47.81 47.81 4.38 54.99 54.99 4.60 59.77 59.77 4.80
Model
FK4DNF005 0.98 1.00
FK4DNB006 0.98 0.96
Heating Indoor
CAR**4817A** 0.96 0.99 58CV(A,X)090---16
CSRH*6012A** 0.98 0.99
*FC4DN(F,B)048 1.00 1.00
CNRH*4821A** 0.98 1.02 58CV(A,X)090---16
CAR**4821A** 0.98 1.02 58CV(A,X)110---20
CNRH*6024A** 0.98 1.02 58CV(A,X)090---16
CNRH*4821A** 0.98 1.02 58CV(A,X)110---20
CNRH*6024A** 0.98 1.01 58CV(A,X)110---20
CAR**6021A** 0.98 1.01 58CV(A,X)110---20
CSRH*4812A** 0.98 1.01 58CV(A,X)090---16
CSRH*6012A** 0.98 1.00 58CV(A,X)090---16
CAR**4824A** 0.98 1.01 58CV(A,X)135---22
CNRV*4821A** 0.98 1.02 58CV(A,X)110--- 20
CAR**6024A** 0.98 1.00 58CV(A,X)135---22
CSRH*4812A** 0.98 1.01 58CV(A,X)110---20
CSRH*6012A** 0.98 0.99 58CV(A,X)110---20
CNRV*4824A** 0.96 0.99 58CV(A,X)135--- 22
CNRH*4821A** 0.97 1.00 58CV(A,X)135---22
CNRH*6024A** 0.98 1.01 58CV(A,X)135---22
CAR**4824A** 0.97 0.99 58CV(A,X)155---22
CNRV*6024A** 0.98 1.01 58CV(A,X)135--- 22
CAR**6024A** 0.98 1.00 58CV(A,X)155---22
CSRH*4812A** 0.98 1.00 58CV(A,X)135---22
CSRH*6012A** 0.98 0.99 58CV(A,X)135---22
CNRV*4824A** 0.97 0.99 58CV(A,X)155--- 22
CNRH*4821A** 0.97 0.99 58CV(A,X)155---22
CNRH*6024A** 0.97 0.99 58CV(A,X)155---22
CAR**4821A** 0.98 1.03 58MVB080---20
CNRV*6024A** 0.97 0.99 58CV(A,X)155--- 22
CAR**6021A** 0.98 1.02 58MVB080---20
CSRH*4812A** 0.97 0.98 58CV(A,X)155---22
CSRH*6012A** 0.98 0.98 58CV(A,X)155---22
CNRV*4821A** 0.98 1.03 58MVB080--- 20
CSRH*4812A** 0.98 1.02 58MVB080---20
CNRH*4821A** 0.98 1.03 58MVB080---20
CSRH*6012A** 0.98 1.01 58MVB080---20
CNRH*6024A** 0.98 1.03 58MVB080---20
29
Page 30
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR3C
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
OUTDOOR COIL ENTERING AIR TEMPERATURES ˚F(˚C)
Capacity MBtuh
tem
Sys-
KW†
Tot a l
25HCR360C30 Outdoor Section With FC4DN(F,B)060 Indoor Section
Capacity MBtuh
tem
Sys-
KW†
Tot a l
Capacity MBtuh
tem
Sys-
KW†
Tot a l
--- 3 ( --- 19 . 4 ) 7 ( ---13.9) 17 (--- 8.3) 27 (---2. 8) 37 (2.8) 47 (8.3) 57 (13.9) 67 (19.4)
Tot a l Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tot al Integ* To ta l Integ* Tota l Integ* To ta l Integ*
Capacity MBtuh
INDOOR AIR
HEAT PUMP HEATING PERFORMANCE
EDB CFM
1750 25.95 23.87 3.95 31.46 28.91 4.10 37.43 34.13 4.27 44.20 39.26 4.46 51.85 47.18 4.69 60.38 60.38 4.89 68.55 68.55 5.15 74.57 74.57 5.35
2000 26.34 24.23 4.00 31.86 29.28 4.13 37.91 34.56 4.28 44.72 39.72 4.46 52.50 47.77 4.67 60.21 60.21 4.83 66.47 66.47 5.01 66.51 66.51 4.99
2250 26.69 24.56 4.05 32.23 29.61 4.17 38.34 34.95 4.32 45.20 40.15 4.49 52.97 48.20 4.64 59.85 59.85 4.82 62.69 62.69 4.88 62.10 62.10 4.85701750 25.46 23.42 4.11 31.03 28.51 4.28 36.99 33.73 4.45 43.69 38.81 4.65 51.22 46.61 4.89 59.75 59.75 5.13 68.30 68.30 5.39 74.72 74.72 5.61
2000 25.85 23.79 4.16 31.44 28.89 4.30 37.45 34.14 4.46 44.22 39.28 4.65 51.82 47.15 4.87 60.00 60.00 5.05 67.83 67.83 5.29 68.80 68.80 5.30
2250 26.22 24.12 4.21 31.81 29.23 4.35 37.85 34.51 4.50 44.65 39.66 4.67 52.37 47.66 4.87 59.78 59.78 5.03 64.71 64.71 5.17 64.66 64.66 5.14751750 24.93 22.93 4.27 30.56 28.09 4.45 36.57 33.34 4.64 43.17 38.34 4.85 50.61 46.05 5.10 59.02 59.02 5.38 67.93 67.93 5.63 75.31 75.31 5.91
2000 25.33 23.30 4.32 30.98 28.47 4.48 37.00 33.74 4.65 43.69 38.80 4.85 51.20 46.59 5.08 59.66 59.66 5.28 67.64 67.64 5.53 71.07 71.07 5.63
2250 25.70 23.64 4.37 31.36 28.82 4.52 37.41 34.11 4.68 44.15 39.21 4.87 51.71 47.06 5.08 59.61 59.61 5.25 65.79 65.79 5.44 66.81 66.81 5.45
FK4DNB006 0.99 0.99
CAR**6024A** 0.99 1.02 58CV(A,X)155--- 22
CSRH*6012A** 0.99 1.02 58CV(A,X)135---22
CNRV*6024A** 0.98 1.03 58CV(A,X)155---22
CSRH*6012A** 0.99 1.02 58CV(A,X)155---22
65
*FC4DN(F,B)060 1.00 1.00
Heating Indoor Model Capacity Power Fu rnace Mod el
CNRH*6024A** 0.98 1.03 58CV(A,X)155--- 22
EDB —EnteringDryBulb
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* The Btuh heating capacity values shown are net integrated values from which the defrost effect has been subtracted. The Btuh heating from supplement heaters should be added to those values to obtain total system capacity.
{ The kW values include the compressor, outdoor fan motor, and indoor blower motor. The kW from supplement heaters should be added to these values to obtain total system kilowatts.
30
Page 31
GUIDE SPECIFICATIONS GENERAL
AIR--COOLED, SPLIT--SYSTEM HEAT PUMP
25HCR3C
1.5 TO 5 NOMINAL TONS
System Description
Outdoor--mounted, air-- cooled, split--system heat pump unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air--cooled coil, propeller--type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition of
ARI Standard 240.
— Unit will be certified for capacity and efficiency, and
listed in the latest ARI directory.
— Unit construction will comply with latest edition of
ANSI/ ASHRAE and with NEC.
— Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit will have C--UL approval.
— Unit cabinet will be capable of withstanding Federal Test
Method Standard No. 141 (Method 6061) 500--hr salt spray test.
— Air--cooled condenser coils will be leak tested at 217
psig and pressure tested at 450 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is stored
and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
— U.S. and Canada only.
PRODUCTS
Equipment
— Factory assembled, single piece, air--cooled heat pump
unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge (R--22), and special features required prior to field start--up.
Cabinet
Unit
— Unit cabinet will be constructed of galvanized steel,
bonderized, and coated with a powder coat paint.
Fans
— Condenser fan will be direct-- drive propeller type,
discharging air upward.
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. — Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with steel wire
safety guards.
— Defrost control board which incorporates defrost relay,
defrost timer and low voltage terminal board.
Compressor
— Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration
isolators.
Condenser
Refrigeration
Operating Characteristics
Electrical Requirements
Special Features
Coil
— Condenser coil will be air cooled. — Coil will be constructed of aluminum finstock with a
resin--based epoxy--phenolic thermoset coating, factory applied by precoating and baking on both sides. The fins are mechanically bonded to copper tubes which are then cleaned, dehydrated, and sealed.
Components
— Refrigeration circuit components will include liquid-- line
shutoff valve with sweat connections, vapor--line shutoff valve with sweat connections, system charge of refrigerant, compressor oil, accumulator, loss of charge switch, and reversing valve.
— The capacity of the unit will meet or exceed _____ Btuh
at a suction temperature of _____ _F/_C. The power consumption at full load will not exceed _____ kW.
— Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F/_C wet bulb and _____ _F/_C dry bulb, and air entering the unit at _____ _F/_C.
— The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
— Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to
_____ v. — Unit electrical power will be single point connection.
— Control circuit will be 24v.
— Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
25HCR3C
31
Page 32
Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Printed in U.S.A.
edition date: 07/07
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
32
Catalog No: 25HCR3C--- 2PD
Replaces: 25HCR3C--- 1PD
Loading...