Carrier 24ACA336A30, 24ACA318A30, 24ACA342A30, 24ACA348A30, 24ACA360A30 Product Data

...
24ACA3 Comfortt13 Series Air Conditioner with Puronr Refrigerant 1---1/2 To 5 Nominal Tons (Size 18 To 60)
Product Data
the environmentally sound refrigerant
Carrier’s Air Con d itio n ers with Puron r refrigerant provide a collection of features unmatched by any other family of equipment. The 24AC A has been designed utilizin g Carrier ’s Pu ron refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.
As an Energy Starr Partner, Carrier Corporation has determined that this product meets the Energy Starr guidelines for energy efficiency. Refer to the combination ratings in the Product Data for system combinations that meet Energy Starr guidelines.
INDUSTRY LEADING FEATURES / BENEFITS
Efficiency
13 -- 15 SEER/11 -- 12 EER
S S Microtube Technologyt refrigeration system S Indoor air quality accessories available
Sound
S
Sound level as low as 74 dBA
S Compressor sound blanket
Comfort
System supports Thermidistatt Control or standard
S
thermostat
Diagnostics
TechAssistt with 6--step diagnostics at--a--glance
S
Reliability
S
Puronr refrigerant -- environmentally sound, won’t deplete the ozone layer and low lifetime servce cost.
S Front--seating service valves S Scroll compressor S Internal pressure--relief valve S Internal thermal overload S Low--pressure switch S High--pressure switch S Filter drier S Balanced refrigeration system for maximum reliability
Durability
WeatherArmort protection package:
S Solid, durable sheet metal construction S Steel louver coil guard S Baked--on, complete coverage, powder paint S Color matched cabinet screws
Applications
S
Long line -- up to 250 ft. total equivalent length, up to 200 feet condenser above evaporator, or up to 80 ft. evaporator above condenser (See Long Line Guideline for more information.)
S Low ambient (down to -- 20_F) with accessory kit
Warranty
Single Phase
S 10--year limited compressor warranty S 5--year limited parts warranty
3--Phase
S 5-- year limited compressor warranty S 1--year limited parts warranty
MODEL NUMBER NOMENCLATURE
Cooling
8
N
6
ISO 9001:2000
REGISTERED
91011 12 13
A00 3 0
Variations Open Open Voltage
A=Stan-
dard
0=Not
Defined
0=Not
Defined
As an Energy Star® Partn er, Carrier Corporation has determined that th is product meets the ENERGY STAR® guidelines for energy efficiency.
Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines.
3=208/230--- 1 5=208/230--- 3
6=460--- 3
123 4 5 6 7
N N A A A/N N N A/N A/N A/N N N
24A C A 3 3
Product
Series
24=AC
Product
Family
A=RES
AC
the environmentally sound refrigerant
Tier
C=
Comfort A=Puron
Major
Series
SEER
3=13 SEER
(Nominal)
Capacity
24ACA3
STANDARD FEATURES
Feature 18 24 30 36 42 48 60
Puron Refrigerant X X X X X X X
Upt to 15 SEER X X X X X X X
Scroll Compressor X X X X X X X
Louvered Coil Guard X X X X X X X
Field --- Installed Filter Drier X X X X X X X
Front---Seating Service Valves X X X X X X X
Internal Pressure--- Relief Valve X X X X X X X
Internal Thermal Overload X X X X X X X
Long Line capability X X X X X X X
Low Ambient capability with Kit X X X X X X X
L o w --- P r e s s u r e S w i t c h X X X X X X X
H i g h --- P r e s s u r e S w i t c h X X X X X X X
Compressor Sound Blanket X X X X X X X
TechAssistt Diagnostics At--- a ---Glance (Single ---Phase Only)
X X X X X X X
Minor
Series
0, 1, 2...
2
PHYSICAL DATA
UNIT SIZE SERIES 18 --- 30 24---30 30 --- 30,50 36--- 30,50,60 42---30,50,60 48---30,50,60 60 ---30,50,60 Operating Weight (lb) 135 135 149 166 210 236 261 Shipping Weight (lb) 156 156 171 189 238 264 295 Compressor Type Scroll REFRIGERANT Puron® (R --- 410A)
Control TXV (Puron® Hard Shutoff) Charge (lb) 4.25 4.35 4.75 5.25 6.2 8.35 8.75
COND FAN Propeller T ype, Direct Drive
Air Discharge Vertical Air Qty (CFM) 1880 2200 2200 2950 3170 3365 4050 Motor HP 1/12 1/10 1/10 1/4 1/5 1/4 1/5 Motor RPM 1100 1100 1100 1100 1100 1100 825
COND COIL
Face Area (Sq. ft.) 9.85 9.85 11.49 14.77 17.25 21.56 25.15 Fins per In. 20 20 25 25 25 25 25 Rows 1 1 1 1 1 1 1 Circuits 3 3 3 3 4 5 5
VALVECONNECT.(In.ID)
Vapor 5/8 5/8 3/4 3/4 7/8 7/8 7/8 Liquid 3/8
REFRIGERANT TUBES* (In. OD)
Vapor (0 --- 80 Ft. Tube Length) 5/8 5/8 3/4 3/4 7/8 7/8 1 --- 1 / 8 Liquid (0 ---250 Ft. Tube Length) 3/8
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
24ACA3
VAPOR LINE SIZING AND COOLI NG CAPACITY LOSS PURON 1--STAGE AIR CONDITIONER APPLICATIONS
LONG LINE APPLICATION: An application is considered ”long line” when the total equivalent tubing length exceeds 80 ft or when there is more than 20 ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250Ft. The maximum vertical separation is 200 Ft when outdoor unit is above indoor unit, and 80
UNIT
NOMINAL
SIZE
(BTUH)
18000
1Stage
Puron AC
24000
1Stage
Puron AC
30000
1Stage
Puron AC
36000
1Stage
Puron AC
42000
1Stage
Puron AC
48000
1Stage
Puron AC
60000
1Stage
Puron AC
ACCEPTABLE
LIQUID LINE
DIAMETERS
(IN. OD)
3/8
3/8
3/8
3/8
3/8
3/8
3/8
ACCEPTABLE
VAPOR LINE
DIAMETERS
(IN. OD)
1/2 1 2 3 3 4 6 7 8 9 10 12
5/8 0 0 1 1 1 1 2 2 3 3 3
5/8 0 1 1 1 2 3 3 4 4 5 6 3/4 0 0 0 0 0 1 1 1 1 1 2 7/8 0 0 0 0 0 0 0 0 0 0 1 5/8 1 2 3 3 3 4 5 6 7 8 9 3/4 0 0 1 1 1 1 2 2 2 3 3 7/8 0 0 0 0 0 1 1 1 1 1 1 5/8 1 2 4 4 5 6 7 9 10 11 13 3/4 0 0 1 1 1 2 2 3 3 4 4 7/8 0 0 0 0 0 1 1 1 1 2 2 3/4 0 1 2 2 2 3 4 4 5 6 6 7/8 0 0 1 1 1 1 2 2 2 3 3
11/8 0 0 0 0 0 0 0 0 0 0 1
3/4 0 1 2 2 3 4 5 5 6 7 8 7/8 0 0 1 1 1 2 2 2 3 3 4
11/8 0 0 0 0 0 0 0 0 1 1 1
3/4 1 2 4 4 5 6 7 9 10 11 12 7/8 0 1 2 2 2 3 4 4 5 5 6
11/8 0 0 0 0 1 1 1 1 1 1 2
Standard Application Long Line Application Requires Accessories
25 50 80 80+ 100 125 150 175 200 225 250
Standard Length = 80 ft. or less total equivalvent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guideline
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See Long Line Application Guideline.
ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline for required accessories. See Long Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss.
COOLING CAPACITY LOSS (%)
TOTAL EQUIVALENT LINE LENGTH (FT..)
3
ACCESSORIES
ORDER NUMBER DESCRIPTION 18 ---30 24 ---30 30 ---30 30 ---50 36 ---30 36 ---50 36 ---60 42--- 30 42 ---50 42 ---60 48 ---30 48 ---50 48 ---60 60--- 30 60 ---50 60 ---60
KAACH1201AAA CRANKCASE HTR X X X X X X
KAACH1301AAA CRANKCASE HTR X X X
KAACH1401AAA CRANKCASE HTR X X X X X X
KAACH1501AAA CRANKCASE HTR X
KSACY0101AAA
KAAFT0101AAA
KSAHS1701AAA
KSALA0301410 LOW AMBIENT PSW X X X X X X X X X X X X X X X X
HC32GE234
HC34GE239
HC38GE228
HC40GE226
24ACA3
HC40GE228
KSALA0601AAA
HC40GE466
HC38GE462
HC40GE467
KSALA0701AAA
KAALS0201LLS SOLENOID VALVE X X X X X X X X X X X X X X X X
KAACS0201PTC STARTASSISTPTC X X X X X X X
KSASF0101AAA SUPPORT FEET X X X X X X X X X X X X X X X X
KAATD0101TDR TIME DELAY RELAY X X X X X X X X X X X X X X X X
KSATX0201PUR TXV PURON HSO X X X X
KSATX0301PUR TXV PURON HSO X X X X X X
KSATX0401PUR TXV PURON HSO X X X
KSATX0501PUR TXV PURON HSO X X X
KAAWS0101AAA WINTER START X X X X X X X X X X X X X X X X
x = Accessory
CYCLE PROTECTOR
FREEZE THERMOSTAT
HARD START (CAP / RELAY)
MOTOR FAN BALL BEARING 230V
MOTOR FAN BALL BEARING 230V
MOTOR FAN BALL BEARING 230V
MOTOR FAN BALL BEARING 230V
MOTOR FAN BALL BEARING 230V
MOTORMASTER 230V
MOTOR FAN BALL BEARING 460V
MOTOR FAN BALL BEARING 460V
MOTOR FAN BALL BEARING 460V
MOTORMASTER 460V
X X X X X X X X X X X X X X X X
X X X X X X X X X X X X X X X X
X X X X X X X
X
X X X
X X
X X
X X X X
X X X X X X X X X X X X
X
X
X X
X X X X
THERMOSTAT / SUBBASE
PKG.
TSTATCCPRH01--- B Thermidistat Control --- Programmable / Non---Programmable Thermostat with Humidity control
TSTATCCPAC01---B T h e r m o s t a t --- A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATCCNAC01--- C T h e r m o s t a t --- A u t o C h a n g e o v e r, N o n --- P r o g r a m m a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATCCBAC01--- B Builder’s Thermostat --- Manual Changeover, Non --- Programmable, _F/_C , 1 --- S t a g e H e a t , 1 --- St a g e C o o l
TSTATCCSEN01--- B Outdoor Air Temperature Sensor
TSTATXXBBP01 Backplate for Builder’s Thermostat
TSTATXXNBP01 Backplate for Non--- Programmable Thermostat
TSTATXXPBP01 Backplate for Programmable Thermostat
TSTATXXCNV10 Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack
DESCRIPTION
4
ACCESSORY USAGE GUIDELINE
REQUIRED FOR LOW --- AMBIENT
ACCESSORY
Ball Bearing Fan Motor Yes{ No No
Compressor Start Assist Capacitor and Relay Ye s Yes No
Crankcase Heater Yes Yes No
Evaporator Freeze Thermostat Yes No No
Liquid---Line Solenoid Valve No
Motor Master®Control or
L o w --- a m b i e n t P r e s s u r e S w i t c h
Thermostatic Expansion Valve (TXV)
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differential (250 ft. Total Equivalent Length), refer to Residential Split---System Long Line
Application Guideline.
{ Required for Low ---Ambient Controller (full modulation MotorMasterr Control only).
Hard Shutoff
Support Feet Recommended No Recommended
Winter Start Control Yes No No
COOLING APPLICATIONS
(Below 55° F)
Yes No No
Yes Yes Yes
REQUIRED FOR
LONG LINE
APPLICATIONS*
(Over 80 ft.)
See Long Line
Application Guideline
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when using MotorMasterr
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor at each start up.
Usage Guideline: Required for single--phase scroll compressors in the
following applications:
Long line Low--ambient cooling
Suggested for all compressors in areas with a history of low voltage problems.
3. Compressor Start Assist — PTC T ype
Solid state electrical device which gives a ”soft” boost to the compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging.
Usage Guideline:
Required in Low--ambient cooling applications. Required in long line applications.
Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short cycling. This control provides an approximate 5--minute delay after power to the compressor has been interrupted for any reason, including power outage, protector control trip, thermostat jiggling, or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when Low--ambient kit has been added.
7. Low --Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits. The control will maintain working head pressure at low--ambient temperatures down to 0_F when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch must be used when cooling operation is at outdoor temperatures below 55_F (12.8_C) to a minimum of 0_F (-- 17.8_C).
Suggested for all commercial applications.
8. MotorMasterr Low-- Ambient Controller
A fan--speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to --20_F (--28.9_C), it maintains condensing temperature at 100_F ±10_F (37.8_C ±
-- 1 2 _C).
Usage Guideline:
A MotorMasterr Low Ambient Controller or Low--Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55_F (12.8_C).
Suggested for all commercial applications.
REQUIRED FOR
SEA COAST APPLICATIONS (Within 2 miles)
No
24ACA3
5
Accessory Description and Usage (Listed Alphabetically) (Cont)
9. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this publication.
10. Support Feet
Four stick--on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing corrosion.
Usage Guideline: Suggested in the following applications: Coastal installations.
Windy areas or where debris is normally circulating. Rooftop installations.
For improved sound ratings.
24ACA3
11. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube. Hard shutoff types are available.
NOTE: When using a hard shutoff TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required.
Usage Guideline:
Accessory required to meet ARI rating and system reliability, where indoor not equipped.
Hard shutoff TXV or LLS required in air conditioner long line applications.
Required for use on all zoning systems.
12. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor not equipped.
13. Winter Start Control
This control is designed to alleviate nuisance opening of the low--pressure switch by bypassing it for the first 3 minutes of operation.
6
ELECTRICAL DATA
UNIT SIZE
--- V O L T A G E , SERIES
18-- -30 24-- -30 58.3 13.5 0.75 17.6 14 14 45 43 25 30-- -30 64.0 12.8 0.75 16.8 14 14 47 45 25 36-- -30 77.0 14.1 1.4 19.0 12 12 66 63 30 42-- -30 112.0 17.9 1.1 23.5 12 12 53 51 40 48-- -30 109.0 19.9 1.4 26.2 10 10 76 73 40 60-- -30 134.0 26.4 1.2 34.2 8 8 91 86 50 30-- -50 36-- -50 71.0 9.2 1.4 12.9 14 14 70 67 20 42-- -50 88.0 13.5 1.2 18.1 12 12 80 76 30 48-- -50 83.1 13.6 1.2 18.2 12 12 79 76 30 60-- -50 110.0 17.7 1.2 23.3 12 12 62 59 40 36-- -60 42-- -60 44.0 6.0 0.5 8.0 14 14 227 216 15 48-- -60 41.0 6.1 0.6 8.2 14 14 222 211 15 60-- -60 52.0 7.8 0.6 10.3 14 14 177 168 15
* Permissible limits of the voltage range at which the unit will operate satisfactorily { If wire is applied at ambient greater than 30˚C(86˚F), con sul t table 310 ---16 of the NEC (ANSI/NFPA 70) . The ampacity of non---metallic---sheathed cable
(NM), trade name ROMEX, shall be that of 60˚C (140˚F) conditions, per the NEC (ANSI/NFPA 70) Article 336--- 26. If other than uncoated (no --- plated), 60_ or 75˚C (140_ or 167˚C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
} Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. * * T i m e --- D e l a y f u s e .
FLA --- F u l l L o a d A m p s LRA --- L o c k e d R o t o r A m p s MCA --- Minimum Circuit Amps RLA --- RatedLoadAmps NOTE: Control circuit is 24--- V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All
motors/compressors contain internal overload protection.
V/PH
208---230 ---1 253 197
208/230---3 253 197
460---3 506 414
OPER
VOLTS*
MAX MIN. LRA RLA FLA 60° C 75° C 60° C 75° C
COMPR FAN
48.0 9.0 0.5 11.7 14 14 67 64 15
58.0 10.1 0.8 13.4 14 14 68 65 20
38.0 5.6 0.7 7.8 14 14 233 222 15
MCA
MIN
WIRE
SIZE{
MIN
WIRE
SIZE{
MAX
LENGTH
(FT)}
MAX
LENGTH
(FT)}
MAX
FUSE**
or CKT
BRK
AMPS
A--WEIGHTED SOUND POWER (DBA)
UNIT SIZE --- VOLTAGE, SERIES
18 --- 30 74 50.0 61.5 64.5 66.5 64.0 61.0 54.5
24 --- 30 74 55.5 63.5 67.0 70.0 66.0 63.5 57.0
30 --- 30 30 --- 50
36 --- 30 36 --- 50 36 --- 60
42 --- 30 42 --- 50 42 --- 60
48 --- 30 48 --- 50 48 --- 60
60 --- 30 60 --- 50 60 --- 60
STANDARD
RATING
74 52.5 63.0 68.5 70.0 66.5 62.5 56.5
74 57.0 65.0 67.5 69.5 67.5 65.0 60.0
74 55.0 64.0 68.0 68.5 64.5 60.0 54.0
74 52.5 62.5 65.5 69.0 63.5 60.5 56.0
74 54.0 59.0 65.5 67.5 63.5 60.0 55.5
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
125 250 500 1000 2000 4000 8000
24ACA324ACA3
CHARGING SUBCOOLING (TXV--TYPE EXPANSION DEVI CE)
UNIT SIZE --- VOLTAGE, SERIES REQUIRED SUBCOOLING (_F)
18 --- 30 8 24 --- 30 13 36 --- 30 36 --- 50 36 --- 60 36 --- 30 36 --- 50 36 --- 60 42 --- 30 42 --- 50 42 --- 60 48 --- 30 48 --- 50 48 --- 60 60 --- 30 60 --- 50 60 --- 60
16
16
10
17
11
7
24ACA3
DIMENSIONS
8
COMBINATION RATINGS
U N I T S I Z E ---
SERIES,
VOLTAGE
18-- -30
INDOOR MODEL
*CAP**1814A** 17,500 TXV 13.00 11.00
CAP**1814A** 17,200 TDR&TXV 14.50 11.70 58CV(A,X)070--- 12
CAP**2414A** 17,700 TXV 13.00 11.00 CAP**2414A** 17,500 TDR&TXV 14.50 11.70 58CV(A,X)070--- 12
CAP**2417A** 17,700 TXV 13.00 11.00 CAP**2417A** 17,500 TDR&TXV 14.50 11.70 58MVB060 ---14 CAP**2417A** 17,600 TDR&TXV 14.50 11.70 58CV(A,X)090--- 16
CNPV*1814A** 17,400 TXV 13.00 11.00 CNPV*1814A** 17,200 TDR&TXV 14.50 11.70 58CV(A,X)070 ---12
CNPV*2414A** 17,500 TXV 13.00 11.00 CNPV*2414A** 17,300 TDR&TXV 14.50 11.70 58CV(A,X)070 ---12
CNPV*2417A** 17,500 TXV 13.00 11.00 CNPV*2417A** 17,300 TDR&TXV 14.50 11.70 58MVB060---14 CNPV*2417A** 17,400 TDR&TXV 14.50 11.70 58CV(A,X)090 ---16
CNPH*2417A** 17,500 TXV 13.00 11.00 CNPH*2417A** 17,300 TDR&TXV 14.50 11.70 58MVB040---14 CNPH*2417A** 17,300 TDR&TXV 14.50 11.70 58MVB060---14 CNPH*2417A** 17,400 TDR&TXV 14.50 11.70 58MVB080---14 CNPH*2417A** 17,300 TDR&TXV 14.50 11.70 58CV(A,X)070 ---12 CNPH*2417A** 17,400 TDR&TXV 14.50 11.70 58CV(A,X)090 ---16
TOTAL CAP.
BTUH
FACT ORY
SUPPLIED
ENHANCEMENT
SEER
STANDARD
RATING
TDR†
EER FURNACE MODEL
24ACA3
24-- -30
CNPF*2418A** 17,500 TXV 13.00 11.00
CSPH*2412A** 17,000 TXV 13.00 11.00 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 58MVB040---14 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 58MVB060---14 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 58MVB080---14 CSPH*2412A** 16,600 TDR&TXV 14.50 11.70 58CV(A,X)070 ---12 CSPH*2412A** 16,700 TDR&TXV 14.50 11.70 58CV(A,X)090 ---16
FY4ANF018 17,400 TDR&TXV 13.00 11.00
FY4ANF024 17,500 TDR&TXV 13.00 11.00 FX4CNF018 17,600 TDR&TXV 14.50 11.70 FX4CNF024 17,900 TDR&TXV 14.50 11.70 FE4ANF002 17,800 TDR&TXV 15.00 12.00 FF1ENP018 17,400 TDR&TXV 13.00 11.00 FF1ENP024 17,600 TDR&TXV 13.20 11.00 FV4BNF002 17,800 TDR&TXV 15.00 12.00
*CAP**2414A** 23,000 TXV 13.00 11
CAP**2414A** 22,600 TDR&TXV 14.00 11.50 58CV(A,X)070--- 12
CAP**2417A** 22,800 TXV 13.00 11.00 CAP**2417A** 22,600 TDR&TXV 14.00 11.50 58MVB060 ---14 CAP**2417A** 22,600 TDR&TXV 14.50 11.70 58CV(A,X)090--- 16
CAP**3014A** 23,000 TXV 13.00 11.00 CAP**3014A** 22,800 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CAP**3017A** 23,000 TXV 13.00 11.00 CAP**3017A** 22,800 TDR&TXV 14.50 11.70 58MVB060 ---14 CAP**3017A** 22,800 TDR&TXV 14.50 11.70 58CV(A,X)090--- 16
CNPV*2414A** 22,600 TXV 13.00 11.00 CNPV*2414A** 22,400 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CNPV*2417A** 22,600 TXV 13.00 11.00 CNPV*2417A** 22,400 TDR&TXV 14.00 11.50 58MVB060---14 CNPV*2417A** 22,400 TDR&TXV 14.00 11.50 58CV(A,X)090 ---16
CNPV*3014A** 22,800 TXV 13.00 11.00 CNPV*3014A** 22,600 TDR&TXV 14.00 11.15 58CV(A,X)070 ---12
CNPV*3017A** 22,800 TXV 13.00 11.00 CNPV*3017A** 22,600 TDR&TXV 14.50 11.70 58MVB060---14 CNPV*3017A** 22,600 TDR&TXV 14.50 11.70 58CV(A,X)090 ---16
See notes on pg. 14
9
COMBINATION RATINGS CONTINUED
U N I T S I Z E ---
VOLTAGE
24ACA3
SERIES,
24-- -30
INDOOR MODEL
CNPH*2417A** 22,600 TXV 13.00 11.00
CNPH*2417A** 22,400 TDR&TXV 14.00 11.50 58MVB040---14
CNPH*2417A** 22,400 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CNPH*3017A** 22,800 TXV 13.00 11.00
CNPH*3017A** 22,600 TDR&TXV 14.50 11.70 58MVB040---14
CNPH*3017A** 22,600 TDR&TXV 14.50 11.70 58CV(A,X)070 ---12
CNPF*2418A** 22,600 TXV 13.00 11.00
CSPH*2412A** 22,000 TXV 13.00 11.00
CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 58MVB040---14
CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 58MVB060---14
CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CSPH*2412A** 21,800 TDR&TXV 14.50 11.70 58CV(A,X)090 ---16
CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 58CV(A,X)110 ---20
CSPH*2412A** 21,800 TDR&TXV 14.00 11.50 58CV(A,X)135 ---22
CSPH*3012A** 22,000 TXV 13.00 11.00
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58MVB040---14
CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 58MVB060---14
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58MVB080---14
CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 58MVB080---20
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58MVB100---20
CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 58MVB120---20
CSPH*3012A** 21,800 TDR&TXV 14.50 11.70 58CV(A,X)070 ---12
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58CV(A,X)090 ---16
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58CV(A,X)110 ---20
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58CV(A,X)135 ---22
CSPH*3012A** 22,000 TDR&TXV 14.50 11.70 58CV(A,X)155 ---22
TOTAL CAP.
BTUH
ENHANCEMENT
FACT ORY
SUPPLIED
SEER
STANDARD
RATING
TDR†
EER FURNACE MODEL
30-- -30 30-- -50
See notes on pg. 14
FY4ANF024 22,600 TDR&TXV 13.00 11.00
FY4ANF030 22,800 TDR&TXV 13.20 11.00
FX4CNF024 23,000 TDR&TXV 14.00 11.50
FX4CNF030 23,200 TDR&TXV 14.00 11.50
FE4ANF002 23,000 TDR&TXV 14.50 11.70
FE4ANF003 23,000 TDR&TXV 14.50 11.70
FF1ENP024 22,600 TDR&TXV 13.00 11.00
FF1ENP030 22,600 TDR&TXV 13.00 11.00
FV4BNF002 23,000 TDR&TXV 14.50 11.70
FV4BNF003 23,000 TDR&TXV 15.00 12.00
*CAP**3014A** 28,000 TXV 13.00 11
CAP**3014A** 27,600 TDR&TXV 13.50 11.20 58CV(A,X)070--- 12
CAP**3017A** 28,000 TXV 13.00 11.00 CAP**3017A** 27,600 TDR&TXV 14.00 11.50 58MVB060 ---14 CAP**3017A** 27,600 TDR&TXV 14.00 11.50 58CV(A,X)090--- 16
CAP**3614A** 28,000 TXV 13.00 11.00 CAP**3614A** 27,600 TDR&TXV 14.00 11.50 58CV(A,X)070--- 12
CAP**3617A** 28,000 TXV 13.00 11.00 CAP**3617A** 27,600 TDR&TXV 14.00 11.50 58MVB060 ---14 CAP**3617A** 27,800 TDR&TXV 14.00 11.50 58CV(A,X)090--- 16
CAP**3621A** 28,000 TXV 13.00 11.00
10
COMBINATION RATINGS CONTINUED
U N I T S I Z E ---
SERIES,
VOLTAGE
INDOOR MODEL
CAP**3621A** 27,800 TDR&TXV 14.00 11.50 58MVB080 ---14 CAP**3621A** 27,800 TDR&TXV 14.00 11.50 58CV(A,X)110--- 20
CNPV*3014A** 27,800 TXV 13.00 11.00 CNPV*3014A** 27,400 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
CNPV*3017A** 27,800 TXV 13.00 11.00 CNPV*3017A** 27,400 TDR&TXV 14.00 11.50 58MVB060---14 CNPV*3017A** 27,400 TDR&TXV 14.00 11.50 58CV(A,X)090 ---16
CNPV*3617A** 27,800 TXV 13.00 11.00 CNPV*3617A** 27,400 TDR&TXV 14.00 11.50 58MVB060---14 CNPV*3617A** 27,400 TDR&TXV 14.00 11.50 58CV(A,X)090 ---16
CNPV*3621A** 27,800 TXV 13.00 11.00 CNPV*3621A** 27,400 TDR&TXV 14.00 11.50 58MVB080---14 CNPV*3621A** 27,600 TDR&TXV 14.00 11.50 58CV(A,X)110 ---20
CNPH*3017A** 27,800 TXV 13.00 11.00 CNPH*3017A** 27,400 TDR&TXV 13.50 11.20 58MVB040---14 CNPH*3017A** 27,400 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
TOTAL CAP.
BTUH
FACT ORY
SUPPLIED
ENHANCEMENT
SEER
STANDARD
RATING
TDR†
EER FURNACE MODEL
24ACA3
30-- -30 30-- -50
CNPH*3617A** 27,800 TXV 13.00 11.00 CNPH*3617A** 27,400 TDR&TXV 13.50 11.20 58MVB040---14 CNPH*3617A** 27,400 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CNPF*3618A** 27,800 TXV 13.00 11.00
CSPH*3012A** 27,000 TXV 13.00 11.00 CSPH*3012A** 26,800 TDR&TXV 13.50 11.20 58MVB040---14 CSPH*3012A** 26,800 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CSPH*3612A** 27,400 TXV 13.20 11.00 CSPH*3612A** 27,200 TDR&TXV 14.00 11.50 58MVB040---14 CSPH*3612A** 27,200 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
FY4ANF030 27,600 TDR&TXV 13.00 11.00
FY4ANF036 27,800 TDR&TXV 13.00 11.00 FX4CNF030 28,000 TDR&TXV 13.50 11.20
FX4CN(B,F)036 28,200 TDR&TXV 14.00 11.50
FE4ANF002 27,800 TDR&TXV 14.00 11.50 FE4ANF003 28,000 TDR&TXV 14.50 11.70 FE4ANF005 28,800 TDR&TXV 15.00 12.00 FF1ENP030 27,400 TDR&TXV 13.00 11.00 FF1ENP036 28,000 TDR&TXV 13.20 11.00 FV4BNF002 27,800 TDR&TXV 14.00 11.50 FV4BNF003 28,000 TDR&TXV 14.50 11.70 FV4BNF005 28,800 TDR&TXV 15.00 12.00
*CAP**3617A** 34,000 TXV 13.00 11.00
CAP**3614A** 33,000 TXV 13.00 11.00 CAP**3614A** 33,000 TDR&TXV 13.50 11.20 58CV(A,X)070--- 12
CAP**3617A** 33,600 TDR&TXV 14.00 11.50 58MVB060 ---14 CAP**3617A** 33,600 TDR&TXV 14.00 11.50 58CV(A,X)090--- 16
CAP**3621A** 34,000 TXV 13.00 11.00 CAP**3621A** 33,600 TDR&TXV 13.50 11.20 58MVB080 ---14 CAP**3621A** 33,800 TDR&TXV 14.00 11.50 58CV(A,X)110--- 20
36-- -30 36-- -50 36-- -60
See notes on pg. 14
CAP**4221A** 34,000 TXV 13.00 11.00 CAP**4221A** 33,800 TDR&TXV 14.00 11.50 58MVB080 ---14 CAP**4221A** 34,000 TDR&TXV 14.00 11.50 58CV(A,X)110--- 20
CAP**4224A** 34,000 TXV 13.00 11.00 CAP**4224A** 33,800 TDR&TXV 14.00 11.50 58MVB040 ---14 CAP**4224A** 34,000 TDR&TXV 14.50 11.70 58CV(A,X)135--- 22
CNPV*3617A** 33,800 TXV 13.00 11.00 CNPV*3617A** 33,200 TDR&TXV 13.50 11.20 58MVB060---14 CNPV*3617A** 33,400 TDR&TXV 14.00 11.50 58CV(A,X)090 ---16
CNPV*3621A** 33,800 TXV 13.00 11.00 CNPV*3621A** 33,600 TDR&TXV 13.00 11.00 58MVB080---14
11
COMBINATION RATINGS CONTINUED
U N I T S I Z E ---
SERIES,
VOLTAGE
INDOOR MODEL
CNPV*3621A** 33,800 TDR&TXV 13.50 11.20 58CV(A,X)110 ---20
CNPV*4221A** 34,000 TXV 13.00 11.00 CNPV*4221A** 34,200 TDR&TXV 14.00 11.50 58MVB080---14 CNPV*4221A** 34,600 TDR&TXV 14.50 11.70 58CV(A,X)110 ---20
CNPH*3617A** 33,800 TXV 13.00 11.00 CNPH*3617A** 33,200 TDR&TXV 13.50 11.20 58MVB040---14 CNPH*3617A** 33,200 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
CNPH*4221A** 34,000 TXV 13.00 11.00 CNPH*4221A** 34,200 TDR&TXV 14.00 11.50 58MVB040---14 CNPH*4221A** 34,400 TDR&TXV 14.00 11.50 58MVB060---14 CNPH*4221A** 34,200 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CNPF*3618A** 33,800 TXV 13.00 11.00
TOTAL CAP.
BTUH
FACT ORY
SUPPLIED
ENHANCEMENT
SEER
STANDARD
RATING
TDR†
EER FURNACE MODEL
24ACA3
36-- -30 36-- -50 36-- -60
CSPH*3612A** 33,600 TXV 13.00 11.00 CSPH*3612A** 33,200 TDR&TXV 14.00 11.50 58MVB040---14 CSPH*3612A** 33,200 TDR&TXV 14.00 11.50 58CV(A,X)070 ---12
CSPH*4212A** 33,800 TXV 13.20 11.20 CSPH*4212A** 33,800 TDR&TXV 13.50 11.20 58MVB040---14 CSPH*4212A** 34,000 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
FY4ANF036 33,800 TDR&TXV 13.00 11.00
FY4ANF042 34,400 TDR&TXV 13.00 11.00
FX4CN(B,F)036 34,400 TDR&TXV 14.00 11.50 FX4CN(B,F)042 34,800 TDR&TXV 14.00 11.50
FE4ANF002 33,600 TDR&TXV 14.00 11.50 FE4ANF003 34,000 TDR&TXV 14.50 11.70 FE4ANF005 35,000 TDR&TXV 15.00 12.00 FE4ANB006 35,400 TDR&TXV 15.00 12.00 FF1ENP036 33,800 TDR&TXV 13.00 11.00 FV4BNF002 33,600 TDR&TXV 14.00 11.50 FV4BNF003 34,000 TDR&TXV 14.50 11.70 FV4BNF005 35,000 TDR&TXV 15.00 12.00 FV4BNB006 35,400 TDR&TXV 15.00 12.00
*CAP**4221A** 41,000 TXV 13.00 11.00
CAP**4221A** 40,000 TDR&TXV 13.50 11.20 58MVB080 ---14 CAP**4221A** 40,500 TDR&TXV 13.50 11.20 58CV(A,X)110--- 20
CAP**4224A** 41,000 TXV 13.00 11.00 CAP**4224A** 40,000 TDR&TXV 13.50 11.20 58MVB040 ---14 CAP**4224A** 40,500 TDR&TXV 14.00 11.50 58CV(A,X)135--- 22
CAP**4817A** 40,000 TXV 13.20 11.00 CAP**4817A** 40,000 TDR&TXV 14.00 11.50 58MVB060 ---14 CAP**4817A** 40,000 TDR&TXV 14.00 11.50 58CV(A,X)090--- 16
CAP**4821A** 41,500 TXV 13.20 11.00 CAP**4821A** 40,500 TDR&TXV 13.50 11.20 58MVB080 ---14 CAP**4821A** 41,000 TDR&TXV 14.00 11.50 58CV(A,X)110--- 20
42-- -30 42-- -50 42-- -60
See notes on pg. 14
CAP**4824A** 41,500 TXV 13.20 11.00 CAP**4824A** 41,000 TDR&TXV 13.50 11.20 58MVB040 ---14 CAP**4824A** 41,000 TDR&TXV 14.50 11.70 58CV(A,X)135--- 22
CNPV*4221A** 41,000 TXV 13.00 11.00 CNPV*4221A** 40,000 TDR&TXV 13.50 11.20 58MVB080---14 CNPV*4221A** 40,000 TDR&TXV 14.00 11.50 58CV(A,X)110 ---20
CNPV*4821A** 40,500 TXV 13.20 11.00 CNPV*4821A** 40,500 TDR&TXV 13.50 11.20 58MVB080---14 CNPV*4821A** 41,000 TDR&TXV 14.00 11.50 58CV(A,X)110 ---20
CNPV*4824A** 41,500 TXV 13.20 11.00 CNPV*4824A** 41,000 TDR&TXV 13.50 11.20 58MVB040---14 CNPV*4824A** 40,500 TDR&TXV 14.50 11.70 58CV(A,X)135 ---22
CNPH*4221A** 41,000 TXV 13.00 11.00 CNPH*4221A** 40,000 TDR&TXV 13.50 11.20 58MVB040---14 CNPH*4221A** 40,500 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
12
COMBINATION RATINGS CONTINUED
U N I T S I Z E ---
SERIES,
VOLTAGE
INDOOR MODEL
CNPH*4821A** 41,500 TXV 13.20 11.00 CNPH*4821A** 40,500 TDR&TXV 13.50 11.20 58MVB040---14 CNPH*4821A** 41,000 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
CNPF*4818A** 41,500 TXV 13.20 11.00
CSPH*4212A** 40,500 TXV 13.20 11.00 CSPH*4212A** 40,000 TDR&TXV 13.50 11.20 58MVB040---14 CSPH*4212A** 40,000 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
TOTAL CAP.
BTUH
FACT ORY
SUPPLIED
ENHANCEMENT
SEER
STANDARD
RATING
TDR†
EER FURNACE MODEL
42-- -30 42-- -50 42-- -60
CSPH*4812A** 41,000 TXV 13.20 11.00 CSPH*4812A** 40,000 TDR&TXV 13.50 11.20 58MVB040---14 CSPH*4812A** 40,000 TDR&TXV 13.50 11.20 58CV(A,X)070 ---12
FY4ANF042 41,000 TDR&TXV 13.00 11.00
FY4ANF048 42,000 TDR&TXV 13.20 11.00
FX4CN(B,F)042 41,500 TDR&TXV 13.50 11.20 FX4CN(B,F)048 42,500 TDR&TXV 14.00 11.50
FE4ANF003 40,500 TDR&TXV 14.00 11.50 FE4ANF005 42,000 TDR&TXV 14.50 11.70 FE4ANB006 42,500 TDR&TXV 15.00 12.00 FV4BNF003 40,500 TDR&TXV 14.00 11.50 FV4BNF005 41,500 TDR&TXV 14.50 11.70 FV4BNB006 42,500 TDR&TXV 15.00 12.00
*CAP**4821A** 46,000 TXV 13.00 11.00
CAP**4817A** 45,500 TXV 13.00 11.00 CAP**4817A** 45,500 TDR&TXV 13.50 11.20 58CV(A,X)090--- 16
CAP**4821A** 45,000 TDR&TXV 13.20 11.00 58MVB080 ---20 CAP**4821A** 45,000 TDR&TXV 13.65 11.40 58MVB100 ---20 CAP**4821A** 45,000 TDR&TXV 13.50 11.20 58CV(A,X)110--- 20
CAP**4824A** 46,000 TXV 13.00 11.00 CAP**4824A** 45,000 TDR&TXV 13.50 11.20 58MVB120 ---20 CAP**4824A** 45,500 TDR&TXV 13.50 11.20 58CV(A,X)135--- 22
CAP**6021A** 47,000 TXV 13.20 11.00 CAP**6021A** 46,000 TDR&TXV 13.50 11.20 58MVB080 ---20 CAP**6021A** 47,500 TDR&TXV 13.50 11.20 58CV(A,X)110--- 20
24ACA3
48-- -30 48-- -50 48-- -60
See notes on pg. 14
CAP**6024A** 47,000 TXV 13.20 11.00 CAP**6024A** 46,000 TDR&TXV 14.00 11.50 58MVB120 ---20 CAP**6024A** 46,500 TDR&TXV 14.00 11.50 58CV(A,X)135--- 22
CNPV*4221A** 44,500 TXV 13.00 10.95 CNPV*4221A** 44,500 TDR&TXV 13.20 11.00 58MVB080---20 CNPV*4221A** 44,500 TDR&TXV 13.50 11.20 58CV(A,X)110 ---20
CNPV*4821A** 46,000 TXV 13.00 11.00 CNPV*4821A** 45,000 TDR&TXV 13.20 11.00 58MVB080---20 CNPV*4821A** 45,000 TDR&TXV 13.50 11.20 58CV(A,X)110 ---20
CNPV*4824A** 46,000 TXV 13.00 11.00 CNPV*4824A** 45,500 TDR&TXV 13.50 11.20 58MVB120---20 CNPV*4824A** 45,500 TDR&TXV 13.50 11.20 58CV(A,X)135 ---22
CNPV*6024A** 47,000 TXV 13.20 11.00 CNPV*6024A** 46,000 TDR&TXV 13.50 11.20 58MVB120---20 CNPV*6024A** 46,000 TDR&TXV 14.00 11.50 58CV(A,X)135 ---22
CNPH*4821A** 46,000 TXV 13.00 11.00 CNPH*4821A** 45,000 TDR&TXV 13.20 11.00 58MVB080---20 CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 58MVB100---20 CNPH*4821A** 45,000 TDR&TXV 13.50 11.20 58CV(A,X)090 ---16 CNPH*4821A** 45,500 TDR&TXV 13.50 11.20 58CV(A,X)110 ---20
CNPH*6024A** 47,000 TXV 13.20 11.00 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58MVB080---20 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58MVB100---20 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58CV(A,X)090 ---16 CNPH*6024A** 46,000 TDR&TXV 13.50 11.20 58CV(A,X)110 ---20
CNPF*4818A** 45,000 TXV 13.00 11.00
13
COMBINATION RATINGS CONTINUED
U N I T S I Z E ---
SERIES,
VOLTAGE
48-- -30 48-- -50 48-- -60
INDOOR MODEL
CSPH*4812A** 45,500 TXV 13.00 11.00 CSPH*4812A** 44,500 TDR&TXV 13.20 11.00 58MVB080---20 CSPH*4812A** 44,500 TDR&TXV 13.50 11.20 58CV(A,X)090 ---16
CSPH*6012A** 46,000 TXV 13.20 11.00 CSPH*6012A** 45,000 TDR&TXV 13.50 11.20 58MVB080---20 CSPH*6012A** 45,000 TDR&TXV 13.50 11.20 58CV(A,X)090 ---16
FX4CN(B,F)048 47,000 TDR&TXV 13.50 11.20 FX4CN(B,F)060 47,500 TDR&TXV 14.00 11.50
FE4ANF005 46,500 TDR&TXV 14.00 11.50 FE4ANB006 47,000 TDR&TXV 14.50 11.70 FV4BNF005 46,500 TDR&TXV 14.00 11.50 FV4BNB006 47,000 TDR&TXV 14.50 11.70
FY4ANF048 46,000 TDR&TXV 13.00 11.00 FY4ANB060 46,500 TDR&TXV 13.20 11.00
*CAP**6024A** 57,500 TXV 13.00 11.00
TOTAL CAP.
BTUH
FACT ORY
SUPPLIED
ENHANCEMENT
SEER
STANDARD
RATING
TDR†
EER FURNACE MODEL
24ACA3
60-- -30 60-- -50 60-- -60
* Tested combination . { In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time ---Delay Relay, KAATD0101TDR, or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
EER — Energy Efficiency Ratio SEER — Seasonal Energy Efficiency Ratio TDR — Ti m e --- D e l a y R e l a y TXV — Thermostatic Expansion Valve
CAP**6021A** 56,500 TXV 13.00 11.00 CAP**6021A** 56,000 TDR&TXV 13.20 11.00 58CV(A,X)110--- 20
CAP**6024A** 56,500 TDR&TXV 13.20 11.00 58CV(A,X)135--- 22 CAP**6024A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)155--- 22
CNPV*6024A** 57,000 TXV 13.00 11.00 CNPV*6024A** 56,000 TDR&TXV 13.50 11.00 58CV(A,X)135 ---22 CNPV*6024A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)155 ---22
CNPH*6024A** 56,000 TXV 13.00 11.00 CNPH*6024A** 56,000 TDR&TXV 13.50 11.20 58CV(A,X)135 ---22 CNPH*6024A** 56,500 TDR&TXV 13.50 11.20 58CV(A,X)155 ---22
CSPH*6012A** 56,500 TXV 13.00 11.00 CSPH*6012A** 55,500 TDR&TXV 13.20 11.00 58CV(A,X)110 ---20 CSPH*6012A** 55,500 TDR&TXV 13.50 11.20 58CV(A,X)135 ---22 CSPH*6012A** 55,500 TDR&TXV 13.50 11.20 58CV(A,X)155 ---22
FX4CN(B,F)060 58,000 TDR&TXV 13.20 11.00
FE4ANB006 57,000 TDR&TXV 13.50 11.20 FV4BNB006 57,000 TDR&TXV 13.50 11.20 FY4ANB060 56,500 TDR&TXV 13.00 11.00
14
DETAILED COOLING CAPACITIES
EVAPORATOR
AIR
CFM EWB
72 20.46 10.76 1.21 19.55 10.41 1.36 18.59 10.05 1.53 17.62 9.69 1.71 16.57 9.30 1.91 15.40 8.88 2.13 67 18.79 13.26 1.22 17.95 12.90 1.37 17.05 12.52 1.53 16.12 12.14 1.72 15.13 11.74 1.92 14.03 11.30 2.13
525
62 17.27 15.73 1.22 16.49 15.36 1.37 15.68 14.97 1.54 14.83 14.55 1.72 14.00 14.00 1.92 13.15 13.15 2.13 57 16.78 16.78 1.23 16.15 16.15 1.37 15.48 15.48 1.54 14.77 14.77 1.72 14.00 14.00 1.92 13.15 13.15 2.13 72 20.79 11.28 1.24 19.83 10.92 1.39 18.83 10.55 1.56 17.83 10.19 1.74 16.76 9.80 1.94 15.55 9.37 2.16 67 19.11 14.10 1.25 18.23 13.73 1.40 17.30 13.36 1.56 16.35 12.97 1.74 15.33 12.57 1.94 14.20 12.12 2.16
600
62 17.66 16.88 1.25 16.87 16.49 1.40 16.06 16.06 1.56 15.32 15.32 1.75 14.51 14.51 1.94 13.61 13.61 2.16 57 17.46 17.46 1.25 16.79 16.79 1.40 16.07 16.07 1.56 15.32 15.32 1.75 14.51 14.51 1.94 13.61 13.61 2.16 72 21.03 11.77 1.27 20.02 11.40 1.42 18.99 11.03 1.58 17.97 10.67 1.77 16.88 10.28 1.97 15.65 9.85 2.18 67 19.33 14.90 1.27 18.43 14.54 1.42 17.48 14.15 1.59 16.51 13.77 1.77 15.48 13.35 1.97 14.33 12.89 2.19
675
62 18.01 17.91 1.28 17.30 17.30 1.43 16.54 16.54 1.59 15.76 15.76 1.77 14.92 14.92 1.97 13.97 13.97 2.19 57 18.01 18.01 1.28 17.30 17.30 1.43 16.55 16.55 1.59 15.76 15.76 1.77 14.92 14.92 1.97 13.97 13.97 2.19
75 85 95 105 115 125
Capacity
MBtuh†
Total
Sens
Total
System
KW**
Multipliers for Determining the Performance With Other Indoor Sections
Cooling Indoor
Model
*CAP**1814A** 1.00 1.00
CAP**2414A** 1.01 1.01
CAP**2417A** 1.01 1.01
CNPF*2418A** 1.00 1.00
CNPH*2417A** 1.00 1.00
CNPV*1814A** 0.99 0.99
CNPV*2414A** 1.00 1.00
CNPV*2417A** 1.00 1.00
CSPH*2412A** 0.97 0.97
FE4ANF002 1.02 0.93
FF1ENP018 0.99 0.99
FF1ENP024 1.01 1.01
FV4BNF002 1.02 0.93
FX4CNF018 1.01 0.95
FX4CNF024 1.02 0.96
FY4ANF018 0.99 0.99
FY4ANF024 1.00 1.00
See notes on pg. 21
Capacity Power Furnace Model
Capacity
MBtuh†
Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡ Total Sens‡
24ACA318A30 Outdoor Section With CAP**1814A** Indoor Section
CONDENSER ENTERING AIR TEMPERATURES deg F
Total
System
KW**
Capacity
MBtuh†
{{
Total
System
KW**
Capacity
MBtuh†
Cooling Indoor
Model
Total
System
KW**
Capacity
MBtuh†
Total
System
KW**
Capacity Power Furnace Model
CAP**1814A** 0.98 0.92 58CV(A,X)070 ---12
CAP**2414A** 1.00 0.94 58CV(A,X)070 ---12
CNPH*2417A** 0.99 0.93 58CV(A,X)070---12
CNPV*1814A** 0.98 0.92 58CV(A,X)070 ---12
CNPV*2414A** 0.99 0.93 58CV(A,X)070 ---12
CSPH*2412A** 0.95 0.89 58CV(A,X)070 ---12
CAP**2417A** 1.01 0.95 58CV(A,X)090 ---16
CNPH*2417A** 0.99 0.93 58CV(A,X)090---16
CNPV*2417A** 0.99 0.93 58CV(A,X)090 ---16
CSPH*2412A** 0.95 0.90 58CV(A,X)090 ---16
CNPH*2417A** 0.99 0.93 58MVB040 ---14
CSPH*2412A** 0.95 0.90 58MVB040---14
CAP**2417A** 1.00 0.94 58MVB060---14
CNPH*2417A** 0.99 0.93 58MVB060 ---14
CNPV*2417A** 0.99 0.93 58MVB060---14
CSPH*2412A** 0.95 0.90 58MVB060---14
CNPH*2417A** 0.99 0.93 58MVB080 ---14
CSPH*2412A** 0.95 0.90 58MVB080---14
Capacity
MBtuh†
Total
System
KW**
24ACA3
15
DETAILED COOLING CAPACITIES{{(CONT.)
EVAPORATOR
AIR
Capacity
CFM EWB
MBtuh†
To t a l
72 27.11 14.29 1.61 25.97 13.86 1.81 24.75 13.40 2.03 23.47 12.92 2.28 22.09 12.41 2.55 20.55 11.85 2.84 67 24.89 17.62 1.61 23.81 17.16 1.81 22.66 16.68 2.03 21.45 16.19 2.28 20.15 15.66 2.55 18.73 15.09 2.85
700
62 22.86 20.91 1.61 21.86 20.44 1.81 20.81 19.93 2.04 19.72 19.39 2.28 18.65 18.65 2.56 17.57 17.57 2.86 57 22.24 22.24 1.61 21.43 21.43 1.82 20.56 20.56 2.04 19.64 19.64 2.28 18.65 18.65 2.56 17.57 17.57 2.86 72 27.54 14.98 1.64 26.35 14.54 1.84 25.08 14.08 2.06 23.76 13.60 2.31 22.34 13.09 2.58 20.75 12.52 2.88 67 25.31 18.74 1.64 24.19 18.29 1.85 23.00 17.81 2.07 21.75 17.31 2.31 20.42 16.77 2.59 18.96 16.19 2.88
800
62 23.37 22.46 1.65 22.36 21.95 1.85 21.35 21.35 2.07 20.38 20.38 2.32 19.33 19.33 2.59 18.18 18.18 2.89 57 23.14 23.14 1.65 22.28 22.28 1.85 21.36 21.36 2.07 20.38 20.38 2.32 19.33 19.33 2.59 18.18 18.18 2.89 72 27.83 15.64 1.68 26.61 15.19 1.88 25.31 14.72 2.10 23.96 14.25 2.34 22.50 13.73 2.61 20.87 13.16 2.91 67 25.61 19.83 1.68 24.46 19.37 1.88 23.25 18.88 2.10 21.97 18.37 2.35 20.61 17.83 2.62 19.12 17.24 2.92
900
62 23.85 23.85 1.68 22.96 22.96 1.88 22.00 22.00 2.10 20.98 20.98 2.35 19.87 19.87 2.62 18.66 18.66 2.92 57 23.87 23.87 1.68 22.97 22.97 1.88 22.00 22.00 2.10 20.98 20.98 2.35 19.87 19.87 2.62 18.66 18.66 2.92
Cooling Indoor
Model
*CAP**2414A** 1.00 1.00
CAP**2417A** 0.99 0.99
24ACA3
CAP**3014A** 1.00 1.00
CAP**3017A** 1.00 1.00
CNPF*2418A** 0.98 0.98
CNPH*2417A** 0.98 0.98
CNPH*3017A** 0.99 0.99
CNPV*2414A** 0.98 0.98
CNPV*2417A** 0.98 0.98
CNPV*3014A** 0.99 0.99
CNPV*3017A** 0.99 0.99
CSPH*2412A** 0.96 0.96
CSPH*3012A** 0.96 0.96
FE4ANF002 1.00 0.94
FE4ANF003 1.00 0.94
FF1ENP024 0.98 0.98
FF1ENP030 0.98 0.98
FV4BNF002 1.00 0.94
FV4BNF003 1.00 0.92
FX4CNF024 1.00 0.96
FX4CNF030 1.01 0.96
FY4ANF024 0.98 0.98
FY4ANF030 0.99 0.99
See notes on pg. 21
75 85 95 105 115 125
Capacity
MBtuh†
Sens
To t a l
24ACA324A30 Outdoor Section With CAP**2414A** Indoor Section
Sens
To t a l
System
KW**
Multipliers for Determining the Performance With Other Indoor Sections
Capacity Power Furnace Model
CONDENSER ENTERING AIR TEMPERATURES deg F
To t a l
System
KW**
Capacity
MBtuh†
To t a l Sens‡ Tot a l
To t a l
System
KW**
Capacity
MBtuh†
Sens
Cooling Indoor
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
To t a l
Capacity Power Furnace Model
Model
CAP**2414A** 0.98 0.94 58CV(A,X)070--- 12
CAP**3014A** 0.99 0.95 58CV(A,X)070--- 12
CNPH*2417A** 0.97 0.93 58CV(A,X)070--- 12
CNPH*3017A** 0.98 0.92 58CV(A,X)070--- 12
CNPV*2414A** 0.97 0.93 58CV(A,X)070 ---12
CNPV*3014A** 0.98 0.97 58CV(A,X)070 ---12
CSPH*2412A** 0.95 0.91 58CV(A,X)070---12
CSPH*3012A** 0.95 0.89 58CV(A,X)070---12
CAP**2417A** 0.98 0.92 58CV(A,X)090--- 16
CAP**3017A** 0.99 0.93 58CV(A,X)090--- 16
CNPV*2417A** 0.97 0.93 58CV(A,X)090 ---16
CNPV*3017A** 0.98 0.92 58CV(A,X)090 ---16
CSPH*2412A** 0.95 0.89 58CV(A,X)090---16
CSPH*3012A** 0.96 0.90 58CV(A,X)090---16
CSPH*2412A** 0.95 0.91 58CV(A,X)110---20
CSPH*3012A** 0.96 0.90 58CV(A,X)110---20
CSPH*2412A** 0.95 0.91 58CV(A,X)135---22
CSPH*3012A** 0.96 0.90 58CV(A,X)135---22
CSPH*3012A** 0.96 0.90 58CV(A,X)155---22
CNPH*2417A** 0.97 0.93 58MVB040--- 14
CNPH*3017A** 0.98 0.92 58MVB040--- 14
CSPH*2412A** 0.95 0.91 58MVB040 ---14
CSPH*3012A** 0.96 0.90 58MVB040 ---14
CAP**2417A** 0.98 0.94 58MVB060---14
CAP**3017A** 0.99 0.93 58MVB060---14
CNPV*2417A** 0.97 0.93 58MVB060 --- 14
CNPV*3017A** 0.98 0.92 58MVB060 --- 14
CSPH*2412A** 0.95 0.91 58MVB060 ---14
CSPH*3012A** 0.95 0.89 58MVB060 ---14
CSPH*3012A** 0.96 0.90 58MVB080 ---14
CSPH*3012A** 0.95 0.89 58MVB080 ---20
CSPH*3012A** 0.96 0.90 58MVB100 ---20
CSPH*3012A** 0.95 0.89 58MVB120 ---20
Capacity
MBtuh†
Sens
To t a l
System
KW**
16
DETAILED COOLING CAPACITIES{{(CONT.)
EVAPORATOR
AIR
CFM EWB
72 33.13 17.60 2.01 31.70 17.06 2.23 30.20 16.49 2.47 28.59 15.90 2.75 26.87 15.27 3.06 25.01 14.60 3.38
875
1000
1125
67 30.12 21.64 2.01 28.78 21.09 2.23 27.37 20.50 2.48 25.87 19.89 2.76 24.27 19.25 3.07 22.59 18.58 3.42 62 27.50 25.68 2.01 26.29 25.09 2.23 25.03 24.47 2.48 23.75 23.75 2.77 22.56 22.56 3.08 21.27 21.27 3.43 57 26.93 26.93 2.01 25.94 25.94 2.24 24.89 24.89 2.48 23.76 23.76 2.77 22.56 22.56 3.08 21.27 21.27 3.43 72 33.69 18.46 2.05 32.21 17.92 2.27 30.64 17.34 2.52 28.98 16.74 2.80 27.20 16.10 3.11 25.32 15.44 3.45 67 30.64 23.04 2.05 29.26 22.48 2.27 27.80 21.89 2.52 26.25 21.27 2.80 24.61 20.61 3.12 22.87 19.92 3.46 62 28.16 27.55 2.06 26.95 26.95 2.28 25.86 25.86 2.53 24.67 24.67 2.81 23.39 23.39 3.12 22.02 22.02 3.47 57 28.03 28.03 2.06 26.98 26.98 2.28 25.86 25.86 2.53 24.67 24.67 2.81 23.39 23.39 3.12 22.02 22.02 3.47 72 34.09 19.27 2.10 32.57 18.72 2.32 30.96 18.14 2.56 29.26 17.54 2.84 27.43 16.89 3.15 25.50 16.22 3.49 67 31.03 24.36 2.10 29.61 23.80 2.32 28.12 23.20 2.57 26.54 22.57 2.85 24.86 21.90 3.16 23.10 21.19 3.50 62 28.94 28.94 2.10 27.83 27.83 2.32 26.66 26.66 2.57 25.40 25.40 2.85 24.06 24.06 3.16 22.61 22.61 3.48 57 28.94 28.94 2.10 27.83 27.83 2.32 26.66 26.66 2.57 25.41 25.41 2.85 24.06 24.06 3.16 22.62 22.62 3.51
Cooling Indoor
Model
To t a l
75 85 95 105 115 125
Capacity
MBtuh†
Sens
To t a l
System
KW**
Capacity Power Furnace Model
*CAP**3014A** 1.00 1.00
CAP**3017A** 1.00 1.00
CAP**3614A** 1.00 1.00
CAP**3617A** 1.00 1.00
CAP**3621A** 1.00 1.00
CNPF*3618A** 0.99 0.99
CNPH*3017A** 0.99 0.99
CNPH*3617A** 0.99 0.99
CNPV*3014A** 0.99 0.99
CNPV*3017A** 0.99 0.99
CNPV*3617A** 0.99 0.99
CNPV*3621A** 0.99 0.99
CSPH*3012A** 0.96 0.96
CSPH*3612A** 0.98 0.98
FE4ANF002 0.99 0.95
FE4ANF003 1.00 0.94
FE4ANF005 1.03 0.94
FF1ENP030 0.98 0.98
FF1ENP036 1.00 1.00
FV4BNF002 0.99 0.95
FV4BNF003 1.00 0.94
FV4BNF005 1.03 0.94
FX4CN(B,F)036 1.01 0.96
FX4CNF030 1.00 0.98
FY4ANF030 0.99 0.99
FY4ANF036 0.99 0.99
See notes on pg. 21
Capacity
MBtuh†
Sens
To t a l
24ACA330A30 Outdoor Section With CAP**3014A** Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
CONDENSER ENTERING AIR TEMPERATURES deg F
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
System
KW**
To t a l
Capacity
MBtuh†
To t a l
Cooling Indoor
Model
CAP**3014A** 0.99 0.97 58CV(A,X)070 ---12
CAP**3614A** 0.99 0.94 58CV(A,X)070 ---12
CNPH*3017A** 0.98 0.94 58CV(A,X)070--- 12
CNPH*3617A** 0.98 0.94 58CV(A,X)070--- 12
CNPV*3014A** 0.98 0.96 58CV(A,X)070 ---12
CSPH*3012A** 0.96 0.92 58CV(A,X)070 ---12
CSPH*3612A** 0.97 0.93 58CV(A,X)070 ---12
CAP**3017A** 0.99 0.94 58CV(A,X)090 ---16
CAP**3617A** 0.99 0.95 58CV(A,X)090 ---16
CNPV*3017A** 0.98 0.94 58CV(A,X)090 ---16
CNPV*3617A** 0.98 0.94 58CV(A,X)090 ---16
CAP**3621A** 0.99 0.95 58CV(A,X)110 ---20
CNPV*3621A** 0.99 0.94 58CV(A,X)110 ---20
CNPH*3017A** 0.98 0.96 58MVB040---14
CNPH*3617A** 0.98 0.96 58MVB040---14
CSPH*3012A** 0.96 0.94 58MVB040 ---14
CSPH*3612A** 0.97 0.93 58MVB040 ---14
CAP**3017A** 0.99 0.94 58MVB060 ---14
CAP**3617A** 0.99 0.94 58MVB060 ---14
CNPV*3017A** 0.98 0.94 58MVB060 ---14
CNPV*3617A** 0.98 0.94 58MVB060 ---14
CAP**3621A** 0.99 0.95 58MVB080 ---14
CNPV*3621A** 0.98 0.94 58MVB080 ---14
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Capacity Power Furnace Model
Sens
To t a l
System
KW**
24ACA3
17
DETAILED COOLING CAPACITIES{{(CONT.)
EVAPORATOR
AIR
CFM EWB
72 40.12 21.34 2.48 38.42 20.70 2.74 36.61 20.02 3.03 34.70 19.31 3.35 32.62 18.55 3.71 30.32 17.72 4.09
1050
1200
1350
67 36.62 26.34 2.47 35.03 25.67 2.73 33.34 24.97 3.02 31.55 24.24 3.34 29.62 23.47 3.70 27.50 22.62 4.09 62 33.54 31.31 2.46 32.11 30.61 2.72 30.61 29.86 3.01 29.06 29.06 3.34 27.62 27.62 3.70 25.99 25.99 4.09 57 32.88 32.88 2.46 31.70 31.70 2.72 30.44 30.44 3.01 29.09 29.09 3.34 27.63 27.63 3.70 26.00 26.00 4.09 72 40.72 22.34 2.54 38.96 21.69 2.80 37.09 21.00 3.09 35.11 20.28 3.41 32.97 19.51 3.76 30.60 18.67 4.15 67 37.19 27.96 2.53 35.54 27.28 2.79 33.80 26.58 3.08 31.96 25.85 3.40 29.98 25.06 3.76 27.81 24.20 4.15 62 34.30 33.50 2.52 32.84 32.84 2.78 31.55 31.55 3.07 30.12 30.12 3.40 28.56 28.56 3.75 26.83 26.83 4.14 57 34.15 34.15 2.52 32.89 32.89 2.78 31.55 31.55 3.07 30.12 30.12 3.40 28.56 28.56 3.75 26.83 26.83 4.14 72 41.16 23.27 2.60 39.34 22.61 2.86 37.42 21.92 3.14 35.40 21.20 3.47 33.21 20.42 3.82 30.78 19.57 4.21 67 37.62 29.51 2.59 35.93 28.83 2.85 34.15 28.12 3.14 32.27 27.38 3.46 30.25 26.57 3.81 28.05 25.67 4.20 62 35.18 35.18 2.58 33.86 33.86 2.84 32.45 32.45 3.13 30.95 30.95 3.46 29.31 29.31 3.81 27.50 27.50 4.20 57 35.19 35.19 2.58 33.86 33.86 2.84 32.46 32.46 3.13 30.95 30.95 3.46 29.31 29.31 3.81 27.50 27.50 4.20
To t a l
75 85 95 105 115 125
Capacity
MBtuh†
Sens
System
KW**
To t a l
Capacity
MBtuh†
Sens
To t a l
24ACA336A30 Outdoor Section With CAP**3617A** Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
Cooling Indoor Model Capacity Power Furnace Model
*CAP**3617A** 1.00 1.00
CAP**3614A** 0.97 0.97
24ACA3
CAP**3621A** 1.00 1.00
CAP**4221A** 1.00 1.00
CAP**4224A** 1.00 1.00
CNPF*3618A** 0.99 0.99
CNPH*3617A** 0.99 0.99
CNPH*4221A** 1.00 1.00
CNPV*3617A** 0.99 0.99
CNPV*3621A** 0.99 0.99
CNPV*4221A** 1.00 1.00
CSPH*3612A** 0.99 0.99
CSPH*4212A** 0.99 0.98
FE4ANB006 1.04 0.95
FE4ANF002 0.99 0.95
FE4ANF003 1.00 0.94
FE4ANF005 1.03 0.94
FF1ENP036 0.99 0.99
FV4BNB006 1.04 0.95
FV4BNF002 0.99 0.95
FV4BNF003 1.00 0.94
FV4BNF005 1.03 0.94
FX4CN(B,F)036 1.01 0.97
FX4CN(B,F)042 1.02 0.98
FY4ANF036 0.99 0.99
FY4ANF042 1.01 1.01
See notes on pg. 21
CONDENSER ENTERING AIR TEMPERATURES deg F
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sen
s‡
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Cooling Indoor Model Capacity Power Furnace Model
CAP**3614A** 0.97 0.95 58CV(A,X)070--- 12
CNPH*3617A** 0.98 0.96 58CV(A,X)070--- 12
CNPH*4221A** 1.01 0.96 58CV(A,X)070--- 12
CSPH*3612A** 0.98 0.93 58CV(A,X)070---12
CSPH*4212A** 1.00 0.98 58CV(A,X)070---12
CAP**3617A** 0.99 0.95 58CV(A,X)090--- 16
CNPV*3617A** 0.98 0.94 58CV(A,X)090--- 16
CAP**3621A** 0.99 0.95 58CV(A,X)110--- 20
CAP**4221A** 1.00 0.96 58CV(A,X)110--- 20
CNPV*3621A** 0.99 0.98 58CV(A,X)110--- 20
CNPV*4221A** 1.02 0.96 58CV(A,X)110--- 20
CAP**4224A** 1.00 0.94 58CV(A,X)135--- 22
CAP**4224A** 0.99 0.95 58MVB040---14
CNPH*3617A** 0.98 0.96 58MVB040---14
CNPH*4221A** 1.01 0.96 58MVB040---14
CSPH*3612A** 0.98 0.93 58MVB040--- 14
CSPH*4212A** 0.99 0.98 58MVB040--- 14
CAP**3617A** 0.99 0.95 58MVB060---14
CNPH*4221A** 1.01 0.97 58MVB060---14
CNPV*3617A** 0.98 0.96 58MVB060---14
CAP**3621A** 0.99 0.97 58MVB080---14
CAP**4221A** 0.99 0.95 58MVB080---14
CNPV*3621A** 0.99 0.99 58MVB080---14
CNPV*4221A** 1.01 0.96 58MVB080---14
Sens
To t a l
System
KW**
18
DETAILED COOLING CAPACITIES{{(CONT.)
EVAPORATOR
AIR
75 85 95 105 115 125
Capacity
CFM EWB
72 48.51 25.52 3.33 46.40 24.71 3.68 44.17 23.86 4.08 41.83 22.99 4.51 39.30 22.05 4.99 36.50 21.03 5.51
1225
1400
1575
67 44.49 31.40 3.31 42.53 30.57 3.66 40.46 29.71 4.06 38.30 28.81 4.50 35.96 27.87 4.98 33.41 26.84 5.51 62 40.85 37.25 3.29 39.08 36.40 3.65 37.24 35.50 4.04 35.33 34.54 4.48 33.39 33.39 4.97 31.44 31.44 5.50 57 39.76 39.76 3.29 38.32 38.32 3.64 36.79 36.79 4.04 35.17 35.17 4.48 33.41 33.41 4.97 31.45 31.45 5.50 72 49.22 26.65 3.40 47.02 25.82 3.76 44.72 24.97 4.15 42.30 24.08 4.59 39.69 23.14 5.07 36.79 22.10 5.59 67 45.18 33.25 3.38 43.15 32.40 3.74 41.00 31.53 4.13 38.76 30.63 4.57 36.37 29.68 62 41.71 39.81 3.37 39.92 38.90 3.72 38.04 38.04 4.12 36.38 36.38 4.56 34.50 34.50 5.05 32.41 32.41 5.58 57 41.28 41.28 3.37 39.74 39.74 3.72 38.11 38.11 4.12 36.38 36.38 4.56 34.50 34.50 5.05 32.41 32.41 5.58 72 49.76 27.73 3.48 47.49 26.90 3.84 45.12 26.04 4.23 42.63 25.14 4.67 39.95 24.19 5.14 36.99 23.14 5.66 67 45.71 35.04 3.46 43.61 34.19 3.82 41.42 33.32 4.21 39.13 32.41 4.65 36.68 31.44 5.13 33.99 30.36 5.65 62 42.55 42.13 3.45 40.89 40.89 3.80 39.17 39.17 4.20 37.34 37.34 4.64 35.37 35.37 5.12 33.16 33.16 5.65 57 42.52 42.52 3.45 40.89 40.89 3.80 39.17 39.17 4.20 37.35 37.35 4.64 35.37 35.37 5.12 33.16 33.16 5.65
Indoor Model
MBtuh†
To t a l
Capacity
Sens
System
*CAP**4221A** 1.00 1.00
CAP**4224A** 1.00 1.00
CAP**4817A** 0.98 0.98
CAP**4821A** 1.01 1.01
CAP**4824A** 1.01 1.01
CNPF*4818A** 1.01 1.01
CNPH*4221A** 1.00 1.00
CNPH*4821A** 1.01 1.01
CNPV*4221A** 1.00 1.00
CNPV*4821A** 0.99 0.99
CNPV*4824A** 1.01 1.01
CSPH*4212A** 0.99 0.99
CSPH*4812A** 1.00 1.00
FE4ANB006 1.04 0.95
FE4ANF003 0.99 0.94
FE4ANF005 1.02 0.96
FV4BNB006 1.04 0.95
FV4BNF003 0.99 0.94
FV4BNF005 1.01 0.95
FX4CN(B,F)042 1.01 0.99
FX4CN(B,F)048 1.04 0.99
FY4ANF042 1.00 1.00
FY4ANF048 1.02 1.02
See notes on pg. 21
To t a l
KW**
Capacity
MBtuh†
Sens
To t a l
24ACA342A30 Outdoor Section With CAP**4221A** Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
Power Furnace Model
CONDENSER ENTERING AIR TEMPERATURES deg F
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Indoor Model
CNPH*4221A** 0.99 0.97 58CV(A,X)070 ---12
CNPH*4821A** 1.00 0.98 58CV(A,X)070 ---12
CSPH*4212A** 0.98 0.96 58CV(A,X)070 ---12
CSPH*4812A** 0.98 0.96 58CV(A,X)070 ---12
CAP**4817A** 0.98 0.93 58CV(A,X)090---16
CAP**4221A** 0.99 0.97 58CV(A,X)110---20
CAP**4821A** 1.00 0.96 58CV(A,X)110---20
CNPV*4221A** 0.98 0.93 58CV(A,X)110---20
CNPV*4821A** 1.00 0.96 58CV(A,X)110---20
CAP**4224A** 0.99 0.94 58CV(A,X)135---22
CAP**4824A** 1.00 0.94 58CV(A,X)135---22
CNPV*4824A** 0.99 0.93 58CV(A,X)135---22
CAP**4224A** 0.98 0.96 58MVB040--- 14
CAP**4824A** 1.00 0.98 58MVB040--- 14
CNPH*4221A** 0.98 0.96 58MVB040--- 14
CNPH*4821A** 0.99 0.97 58MVB040--- 14
CNPV*4824A** 1.00 0.98 58MVB040 ---14
CSPH*4212A** 0.98 0.96 58MVB040---14
CSPH*4812A** 0.98 0.96 58MVB040---14
CAP**4817A** 0.98 0.93 58MVB060--- 14
CAP**4221A** 0.98 0.96 58MVB080--- 14
CAP**4821A** 0.99 0.97 58MVB080--- 14
Sens
To t a l
System
KW**
Capacity
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
To t a l
5.05
33.74 28.63 5.58
MBtuh†
Power Furnace Model
Sens
To t a l
System
KW**
24ACA3
19
DETAILED COOLING CAPACITIES{{(CONT.)
EVAPORATOR
CFM EWB
1400
1600
1800
Cooling Indoor
*CAP**4821A** 1.00 1.00
CAP**4817A** 0.99 0.99
24ACA3
CAP**4824A** 1.00 1.00
CAP**6021A** 1.02 1.02
CAP**6024A** 1.02 1.02
CNPF*4818A** 0.98 0.98
CNPH*4821A** 1.00 1.00
CNPH*6024A** 1.02 1.02
CNPV*4221A** 0.97 0.97
CNPV*4821A** 1.00 1.00
CNPV*4824A** 1.00 1.00
CNPV*6024A** 1.02 1.02
CSPH*4812A** 0.99 0.99
CSPH*6012A** 1.00 1.00
FX4CN(B,F)048 1.02 1.00
FX4CN(B,F)060 1.03 0.99
See notes on pg. 21
AIR
To t a l
72 55.04 28.49 3.35 52.62 27.54 3.75 50.08 26.56 4.20 47.38 25.54 4.72 44.49 24.45 5.30 41.25 23.26 6.01 67 49.86 34.52 3.35 47.63 33.55 3.75 45.27 32.56 4.21 42.77 31.51 4.73 40.10 30.41 5.33 37.08 29.19 6.08 62 45.26 40.60 3.35 43.30 39.77 3.76 41.26 38.91 4.22 39.15 38.04 4.74 37.27 37.27 5.34 35.05 35.05 6.09 57 44.65 44.65 3.35 42.99 42.99 3.76 41.23 41.23 4.22 39.35 39.35 4.74 37.33 37.33 5.34 35.06 35.06 6.09 72 56.06 29.65 3.42 53.54 28.69 3.82 50.89 27.69 4.27 48.09 26.65 4.79 45.09 25.55 5.36 41.76 24.34 6.06 67 50.79 36.35 3.42 48.45 35.38 3.82 46.00 34.36 4.28 43.40 33.30 4.80 40.63 32.17 5.39 37.50 30.93 6.14 62 46.36 43.45 3.42 44.40 42.66 3.83 42.52 41.92 4.17 40.77 40.77 4.81 38.63 38.63 5.40 36.19 36.19 6.15 57 46.41 46.41 3.42 44.64 44.64 3.83 42.77 42.77 4.28 40.78 40.78 4.81 38.63 38.63 5.40 36.19 36.19 6.15 72 56.83 30.71 3.49 54.22 29.73 3.89 51.49 28.72 4.34 48.61 27.66 4.85 45.53 26.54 5.43 42.11 25.32 6.12 67 51.48 38.05 3.49 49.06 37.05 3.89 46.53 36.02 4.35 43.86 34.94 4.87 41.00 33.80 5.46 37.80 32.58 6.20 62 47.45 46.27 3.50 45.69 45.69 3.90 44.03 44.03 4.36 41.94 41.94 4.88 39.69 39.69 5.47 37.12 37.12 6.21 57 47.87 47.87 3.49 46.01 46.01 3.90 44.04 44.04 4.36 41.95 41.95 4.88 39.69 39.69 5.47 37.13 37.13 6.21
75 85 95 105 115 125
Capacity
MBtuh†
Sens
To t a l
System
KW**
Capacity
MBtuh†
Sens
To t a l
24ACA348A30 Outdoor Section With CAP**4821A** Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
Model
FE4ANB006 1.02 0.96
FE4ANF005 1.01 0.97
FV4BNB006 1.02 0.96
FV4BNF005 1.01 0.97
FY4ANB060 1.01 1.01
FY4ANF048 1.00 1.00
Capacity Power Furnace Model
CONDENSER ENTERING AIR TEMPERATURES deg F
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
To t a l
System
KW**
Capacity
MBtuh†
Sens
To t a l
Cooling Indoor
Model
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Capacity Power Furnace Model
CAP**4817A** 0.99 0.97 58CV(A,X)090 - -- 16
CNPH*4821A** 0.98 0.96 58CV(A,X)090 ---16
CNPH*6024A** 1.00 0.98 58CV(A,X)090 ---16
CSPH*4812A** 0.97 0.95 58CV(A,X)090--- 16
CSPH*6012A** 0.98 0.96 58CV(A,X)090--- 16
CAP**4821A** 0.98 0.96 58CV(A,X)110 - -- 20
CAP**6021A** 1.03 1.01 58CV(A,X)110 - -- 20
CNPH*4821A** 0.99 0.97 58CV(A,X)110 ---20
CNPH*6024A** 1.00 0.98 58CV(A,X)110 ---20
CNPV*4221A** 0.97 0.95 58CV(A,X)110--- 20
CNPV*4821A** 0.98 0.96 58CV(A,X)110--- 20
CAP**4824A** 0.99 0.97 58CV(A,X)135 - -- 22
CAP**6024A** 1.01 0.97 58CV(A,X)135 - -- 22
CNPV*4824A** 0.99 0.97 58CV(A,X)135--- 22
CNPV*6024A** 1.00 0.96 58CV(A,X)135--- 22
CAP**4821A** 0.98 0.98 58MVB080--- 20
CAP**6021A** 1.00 0.98 58MVB080--- 20
CNPH*4821A** 0.98 0.98 58MVB080 ---20
CNPH*6024A** 1.00 0.98 58MVB080 ---20
CNPV*4221A** 0.97 0.97 58MVB080---20
CNPV*4821A** 0.98 0.98 58MVB080---20
CSPH*4812A** 0.97 0.97 58MVB080---20
CSPH*6012A** 0.98 0.96 58MVB080---20
CAP**4821A** 0.98 0.94 58MVB100--- 20
CNPH*4821A** 0.98 0.96 58MVB100 ---20
CNPH*6024A** 1.00 0.98 58MVB100 ---20
CAP**4824A** 0.98 0.96 58MVB120--- 20
CAP**6024A** 1.00 0.96 58MVB120--- 20
CNPV*4824A** 0.99 0.97 58MVB120---20
CNPV*6024A** 1.00 0.98 58MVB120---20
Sens
To t a l
System
KW**
20
DETAILED COOLING CAPACITIES{{(CONT.)
EVAPORATOR
AIR
CFM EWB
72 67.65 35.66 4.15 64.56 34.48 4.58 61.30 33.25 5.06 57.89 31.98 5.58 54.20 30.63 6.15 50.10 29.15 6.77
1750
2000
2250
67 62.07 43.94 4.10 59.24 42.75 4.53 56.25 41.50 5.01 53.12 40.22 5.54 49.74 38.85 6.11 46.03 37.38 6.74 62 57.01 52.17 4.06 54.45 50.95 4.49 51.79 49.66 4.97 49.04 48.27 5.50 46.34 46.34 6.08 43.50 43.50 6.72 57 55.50 55.50 4.04 53.42 53.42 4.48 51.22 51.22 4.96 48.89 48.89 5.50 46.35 46.35 6.08 43.51 43.51 6.72 72 68.69 37.30 4.26 65.46 36.09 4.69 62.07 34.85 5.16 58.54 33.56 5.69 54.71 32.19 6.26 50.48 30.69 6.87 67 63.07 46.60 4.21 60.11 45.38 4.64 57.00 44.12 5.11 53.75 42.82 5.64 50.27 41.45 6.21 46.44 39.94 6.84 62 58.17 55.80 4.16 55.57 54.47 4.59 52.95 52.95 5.07 50.49 50.49 5.61 47.78 47.78 6.19 44.74 44.74 6.82 57 57.57 57.57 4.16 55.35 55.35 4.59 52.99 52.99 5.07 50.50 50.50 5.61 47.78 47.78 6.19 44.74 44.74 6.82 72 69.44 38.83 4.36 66.10 37.62 4.79 62.61 36.36 5.27 58.97 35.06 5.79 55.04 33.67 6.36 50.70 32.16 6.97 67 63.79 49.12 4.31 60.73 47.89 4.74 57.53 46.62 5.21 54.20 45.31 5.74 50.63 43.90 6.31 46.72 42.34 6.93 62 59.18 59.18 4.27 56.90 56.90 4.70 54.41 54.41 5.18 51.77 51.77 5.72 48.91 48.91 6.30 45.70 45.70 6.93 57 59.25 59.25 4.27 56.90 56.90 4.70 54.42 54.42 5.18 51.78 51.78 5.72 48.91 48.91 6.30 45.70 45.70 6.93
To t a l
75 85 95 105 115 125
Capacity
MBtuh†
Sens
To t a l
System
KW**
Capacity
MBtuh†
Sens
To t a l
24ACA360A30 Outdoor Section With CAP**6024A** Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
Cooling Indoor
Model
*CAP**6024A** 1.00 1.00
CAP**6021A** 0.98 0.98
CNPH*6024A** 0.97 0.97
CNPV*6024A** 0.99 0.99
CSPH*6012A** 0.98 0.98
FE4ANB006 0.99 0.97
FV4BNB006 0.99 0.97
FX4CN(B,F)060 1.01 1.01
FY4ANB060 0.98 0.98
* Tested combination.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted. } Sensible capacities shown are based on 80˚F(27˚C) entering air at the indoor coil. For sensible capacities at other than 80˚F(27˚C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80˚F(27˚C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air per degree above 80˚F(27˚C).
** Total system kW is total of indoor and outdoor unit kilowatts. {{ Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur. When the required data fall between the published data, interpolation may be performed.
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
Capacity Power Furnace Model
CONDENSER ENTERING AIR TEMPERATURES deg F
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Cooling Indoor
Model
CAP**6021A** 0.97 0.97 58CV(A,X)110 ---20
CSPH*6012A** 0.97 0.97 58CV(A,X)110 ---20
CAP**6024A** 0.98 0.98 58CV(A,X)135 ---22
CNPH*6024A** 0.97 0.96 58CV(A,X)135--- 22
CNPV*6024A** 0.97 0.97 58CV(A,X)135--- 22
CSPH*6012A** 0.97 0.95 58CV(A,X)135 ---22
CAP**6024A** 0.98 0.97 58CV(A,X)155 ---22
CNPH*6024A** 0.98 0.97 58CV(A,X)155--- 22
CNPV*6024A** 0.98 0.97 58CV(A,X)155--- 22
CSPH*6012A** 0.97 0.95 58CV(A,X)155 ---22
Capacity
MBtuh†
To t a l
Sens
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
Capacity Power Furnace Model
To t a l
KW**
24ACA3
21
GUIDE SPECIFICATIONS GENERAL
System Description
Outdoor--mounted, air--cooled, split--system air conditioner unit suitable for ground or rooftop installation. Unit consists of a hermetic compressor, an air--cooled coil, propeller--type condenser fan, and a control box. Unit will discharge supply air upward as shown on contract drawings. Unit will be used in a refrigeration circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition
of ARI Standard 210.
— Unit will be certified for capacity and efficiency, and
listed in t he latest ARI directory.
— Unit construction will comply with latest edition of
ANSI/ASHRAE and with NEC.
— Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit will have c--UL approval.
24ACA324ACA3
— Unit cabinet will be capable of withstanding Federal
Test Method Standard No. 141 (Method 6061) 500--hr salt spray test.
— Air--cooled condenser coils will be leak tested at 150
psig and pressure tested at 450 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is
stored and handled per unit manufacturer’s recommendations.
Warranty (for inclusion by specifying engineer)
— U.S. and Canada only.
PRODUCTS
Equipment
— Factory--assembled, single--piece, air--cooled air
conditioner unit. Contained within the unit enclosure is all factory wiring, piping, controls, compressor, refrigerant charge Puronr (R--410A), and special features required prior to field start--up.
Unit Cabine
s
Fan
t
— Unit cabinet, including louvered coil guard, will be
constructed of galvanized steel, bonderized, and coated with a powder coat paint.
— Condenser fan will be direct--drive propeller type,
discharging a ir upward.
AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER
1--1/2 TO 5 NOMINAL TONS
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant. — Fan blades will be statically and dynamically balanced. — Condenser fan openings will be equipped with coated
steel wire safety guards.
Compresso
r — Compressor will be hermetically sealed. — Compressor will be mounted on rubber vibration
isolators.
— Compressor will be covered with a sound absorbing
blanket.
Condenser Coi
l — Condenser coil will be air cooled. — Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned, dehydrated, and sealed.
Refrigeration Component
s
— Refrigeration circuit components will include
liquid--line shutoff valve with sweat connections, vapor--line shutoff valve with sweat connections, system charge of Puronr (R--410A) refrigerant, and compressor oil.
— Unit will be equipped with high--pressure switch, low
pressure switch and filter drier for Puron refrigerant.
Operating Characteristics
— The capacity of the unit will meet or exceed _____
Btuh at a suction temperature of _____ _F. The power consumption at full load will not exceed _____ kW.
— Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____ Btuh or greater at conditions of _____ CFM entering air temperature at the evaporator at _____ _F wet bulb and _____ _F dry bulb, and air entering the unit at _____ _F.
— The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v to _____ v.
— Nominal unit electrical characteristics will be _____ v,
three phase, 60 hz. The unit will be capable of satisfactory operation within voltage limits of _____ v
to _____ v. — Unit electrical power will be single point connection. — Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
24ACA3
Copyright 2006 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Printed in U.S.A. edition date: 07/06