24ACA3
Comfortt13 Series Air Conditioner
with Puronr Refrigerant
1---1/2 To 5 Nominal Tons (Size 18 To 60)
Product Data
the environmentally sound refrigerant
Carrier’s Air Con d itio n ers with Puron r refrigerant provide a
collection of features unmatched by any other family of equipment.
The 24AC A has been designed utilizin g Carrier ’s Pu ron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth’s ozone
layer.
As an Energy Starr Partner, Carrier Corporation has determined
that this product meets the Energy Starr guidelines for energy
efficiency. Refer to the combination ratings in the Product Data for
system combinations that meet Energy Starr guidelines.
INDUSTRY LEADING FEATURES /
BENEFITS
Efficiency
13 -- 15 SEER/11 -- 12 EER
S
SMicrotube Technologyt refrigeration system
SIndoor air quality accessories available
Sound
S
Sound level as low as 74 dBA
SCompressor sound blanket
Comfort
System supports Thermidistatt Control or standard
S
thermostat
Diagnostics
TechAssistt with 6--step diagnostics at--a--glance
S
Reliability
S
Puronr refrigerant -- environmentally sound, won’t
deplete the ozone layer and low lifetime servce cost.
SFront--seating service valves
SScroll compressor
SInternal pressure--relief valve
SInternal thermal overload
SLow--pressure switch
SHigh--pressure switch
SFilter drier
SBalanced refrigeration system for maximum reliability
Durability
WeatherArmort protection package:
SSolid, durable sheet metal construction
SSteel louver coil guard
SBaked--on, complete coverage, powder paint
SColor matched cabinet screws
Applications
S
Long line -- up to 250 ft. total equivalent length, up to
200 feet condenser above evaporator, or up to 80 ft.
evaporator above condenser (See Long Line Guideline
for more information.)
SLow ambient (down to -- 20_F) with accessory kit
Warranty
Single Phase
S10--year limited compressor warranty
S5--year limited parts warranty
3--Phase
S5-- year limited compressor warranty
S1--year limited parts warranty
MODEL NUMBER NOMENCLATURE
Cooling
8
N
6
ISO 9001:2000
REGISTERED
91011 1213
A00 30
VariationsOpenOpenVoltage
A=Stan-
dard
0=Not
Defined
0=Not
Defined
As an Energy Star® Partn er, Carrier
Corporation has determined that th is
product meets the ENERGY STAR®
guidelines for energy efficiency.
Refer to the combination ratings in
Product Data for system combinations that
meet Energy Star guidelines.
3=208/230--- 1
5=208/230--- 3
6=460--- 3
123 4 5 6 7
NNAAA/NNNA/NA/NA/NNN
24A C A 3 3
Product
Series
24=AC
Product
Family
A=RES
AC
the environmentally sound refrigerant
Tier
C=
Comfort A=Puron
Major
Series
SEER
3=13
SEER
(Nominal)
Capacity
24ACA3
STANDARD FEATURES
Feature18243036424860
Puron RefrigerantXXXXXXX
Upt to 15 SEERXXXXXXX
Scroll CompressorXXXXXXX
Louvered Coil GuardXXXXXXX
Field --- Installed Filter DrierXXXXXXX
Front---Seating Service ValvesXXXXXXX
Internal Pressure--- Relief ValveXXXXXXX
Internal Thermal OverloadXXXXXXX
Long Line capabilityXXXXXXX
Low Ambient capability with KitXXXXXXX
L o w --- P r e s s u r e S w i t c hXXXXXXX
H i g h --- P r e s s u r e S w i t c hXXXXXXX
Compressor Sound BlanketXXXXXXX
TechAssistt Diagnostics At--- a ---Glance
(Single ---Phase Only)
ControlTXV (Puron® Hard Shutoff)
Charge (lb)4.254.354.755.256.28.358.75
COND FANPropeller T ype, Direct Drive
Air DischargeVertical
Air Qty (CFM)1880220022002950317033654050
Motor HP1/121/101/101/41/51/41/5
Motor RPM110011001100110011001100825
COND COIL
Face Area (Sq. ft.)9.859.8511.4914.7717.2521.5625.15
Fins per In.20202525252525
Rows1111111
Circuits3333455
VALVECONNECT.(In.ID)
Vapor5/85/83/43/47/87/87/8
Liquid3/8
REFRIGERANT TUBES* (In. OD)
Vapor (0 --- 80 Ft. Tube Length)5/85/83/43/47/87/81 --- 1 / 8
Liquid (0 ---250 Ft. Tube Length)3/8
* For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline.
Note: See unit Installation Instruction for proper installation.
24ACA3
VAPOR LINE SIZING AND COOLI NG CAPACITY LOSS
PURON 1--STAGE AIR CONDITIONER APPLICATIONS
LONG LINE APPLICATION: An application is considered ”long
line” when the total equivalent tubing length exceeds 80 ft or when
there is more than 20 ft. vertical separation between indoor and
outdoor units. These applications require additional accessories and
system modifications for reliable system operation. The maximum
allowable total equivalent length is 250Ft. The maximum vertical
separation is 200 Ft when outdoor unit is above indoor unit, and 80
Standard ApplicationLong Line Application Requires Accessories
25508080+100125150175200225250
Standard Length = 80 ft. or less total equivalvent length
Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guideline
Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit. See
Long Line Application Guideline.
ft. when the outdoor unit is below the indoor unit. Refer to
Accessory Usage Guideline for required accessories. See Long
Line Application Guideline for required piping and system
modifications. Also, refer to the table below for the acceptable
vapor tube diameters based on the total length to minimize the
cooling capacity loss.
TSTATCCPRH01--- BThermidistat Control --- Programmable / Non---Programmable Thermostat with Humidity control
TSTATCCPAC01---BT h e r m o s t a t --- A u t o C h a n g e o v e r, 7 --- D a y P r o g r a m m a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATCCNAC01--- CT h e r m o s t a t --- A u t o C h a n g e o v e r, N o n --- P r o g r a m m a b l e , _F/_C , 1 --- S t a g e H e a t , 1 --- S t a g e C o o l
TSTATCCBAC01--- BBuilder’s Thermostat --- Manual Changeover, Non --- Programmable, _F/_C , 1 --- S t a g e H e a t , 1 --- St a g e C o o l
TSTATCCSEN01--- BOutdoor Air Temperature Sensor
TSTATXXBBP01Backplate for Builder’s Thermostat
TSTATXXNBP01Backplate for Non--- Programmable Thermostat
TSTATXXPBP01Backplate for Programmable Thermostat
TSTATXXCNV10Thermostat Conversion Kit (4 to 5 wires) --- 10 Pack
DESCRIPTION
4
ACCESSORY USAGE GUIDELINE
REQUIRED FOR LOW --- AMBIENT
ACCESSORY
Ball Bearing Fan MotorYes{NoNo
Compressor Start Assist Capacitor and RelayYe sYesNo
Crankcase HeaterYesYesNo
Evaporator Freeze ThermostatYesNoNo
Liquid---Line Solenoid ValveNo
Motor Master®Control or
L o w --- a m b i e n t P r e s s u r e S w i t c h
Thermostatic Expansion Valve (TXV)
* For tubing line sets between 80 and 200 ft. and/or 20 ft. vertical differential (250 ft. Total Equivalent Length), refer to Residential Split---System Long Line
Application Guideline.
{ Required for Low ---Ambient Controller (full modulation MotorMasterr Control only).
Hard Shutoff
Support FeetRecommendedNoRecommended
Winter Start ControlYesNoNo
COOLING APPLICATIONS
(Below 55° F)
YesNoNo
YesYesYes
REQUIRED FOR
LONG LINE
APPLICATIONS*
(Over 80 ft.)
See Long Line
Application Guideline
Accessory Description and Usage (Listed Alphabetically)
1. Ball--Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction
while maintaining bearing lubrication.
Usage Guideline:
Required on all units when using MotorMasterr
2. Compressor Start Assist -- Capacitor and Relay
Start capacitor and relay gives a ”hard” boost to compressor motor
at each start up.
Usage Guideline:
Required for single--phase scroll compressors in the
following applications:
Long line
Low--ambient cooling
Suggested for all compressors in areas with a history of
low voltage problems.
3. Compressor Start Assist — PTC T ype
Solid state electrical device which gives a ”soft” boost to the
compressor at each start--up.
Usage Guideline:
Suggested in installations with marginal power supply.
4. Crankcase Heater
An electric resistance heater which mounts to the base of the
compressor to keep the lubricant warm during off cycles. Improves
compressor lubrication on restart and minimizes the chance of
liquid slugging.
Usage Guideline:
Required in Low--ambient cooling applications.
Required in long line applications.
Suggested in all commercial applications.
5. Cycle Protector
The cycle protector is designed to prevent compressor short
cycling. This control provides an approximate 5--minute delay after
power to the compressor has been interrupted for any reason,
including power outage, protector control trip, thermostat jiggling,
or normal cycling.
6. Evaporator Freeze Thermostat
An SPST temperature--actuated switch that stops unit operation
when evaporator reaches freeze--up conditions.
Usage Guideline:
Required when Low--ambient kit has been added.
7. Low --Ambient Pressure Switch Kit
A long life pressure switch which is mounted to outdoor unit
service valve. It is designed to cycle the outdoor fan motor in order
to maintain head pressure within normal operating limits. The
control will maintain working head pressure at low--ambient
temperatures down to 0_F when properly installed.
Usage Guideline:
A Low--Ambient Pressure Switch must be used when
cooling operation is at outdoor temperatures below
55_F (12.8_C) to a minimum of 0_F (-- 17.8_C).
Suggested for all commercial applications.
8. MotorMasterr Low-- Ambient Controller
A fan--speed control device activated by a temperature sensor,
designed to control condenser fan motor speed in response to the
saturated, condensing temperature during operation in cooling
mode only. For outdoor temperatures down to --20_F (--28.9_C), it
maintains condensing temperature at 100_F ±10_F (37.8_C ±
-- 1 2 _C).
Usage Guideline:
A MotorMasterrLow Ambient Controller or
Low--Ambient Pressure Switch must be used when
cooling operation is used at outdoor temperatures
below 55_F (12.8_C).
Suggested for all commercial applications.
REQUIRED FOR
SEA COAST
APPLICATIONS
(Within 2 miles)
No
24ACA3
5
Accessory Description and Usage (Listed Alphabetically) (Cont)
9. Outdoor Air Temperature Sensor
Designed for use with Carrier Thermostats listed in this
publication. This device enables the thermostat to display the
outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary
heat lock out.
Usage Guideline:
Suggested for all Carrier thermostats listed in this
publication.
10. Support Feet
Four stick--on plastic feet that raise the unit 4 in. above the
mounting pad. This allows sand, dirt, and other debris to be
flushed from the unit base, minimizing corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
24ACA3
11. Thermostatic Expansion Valve (TXV)
A modulating flow--control valve which meters refrigerant liquid
flow rate into the evaporator in response to the superheat of the
refrigerant gas leaving the evaporator.
Kit includes valve, adapter tubes, and external equalizer tube. Hard
shutoff types are available.
NOTE: When using a hard shutoff TXV with single phase
reciprocating compressors, a Compressor Start Assist Capacitor
and Relay is required.
Usage Guideline:
Accessory required to meet ARI rating and system
reliability, where indoor not equipped.
Hard shutoff TXV or LLS required in air conditioner
long line applications.
Required for use on all zoning systems.
12. Time--Delay Relay
An SPST delay relay which briefly continues operation of indoor
blower motor to provide additional cooling after the compressor
cycles off.
NOTE: Most indoor unit controls include this feature. For those
that do not, use the guideline below.
Usage Guideline:
Accessory required to meet ARI rating, where indoor
not equipped.
13. Winter Start Control
This control is designed to alleviate nuisance opening of the
low--pressure switch by bypassing it for the first 3 minutes of
operation.
* Permissible limits of the voltage range at which the unit will operate satisfactorily
{ If wire is applied at ambient greater than 30˚C(86˚F), con sul t table 310 ---16 of the NEC (ANSI/NFPA 70) . The ampacity of non---metallic---sheathed cable
(NM), trade name ROMEX, shall be that of 60˚C (140˚F) conditions, per the NEC (ANSI/NFPA 70) Article 336--- 26. If other than uncoated (no --- plated), 60_
or 75˚C (140_ or 167˚C) insulation, copper wire (solid wire for 10 AWG or smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables
of the NEC (ANSI/NFPA 70).
}Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%.
* * T i m e --- D e l a y f u s e .
FLA--- F u l l L o a d A m p s
LRA--- L o c k e d R o t o r A m p s
MCA--- Minimum Circuit Amps
RLA--- RatedLoadAmps
NOTE: Control circuit is 24--- V on all units and requires external power source. Copper wire must be used from service disconnect to unit. All
* Tested combination .
{ In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use
either the accessory Time ---Delay Relay, KAATD0101TDR, or a furnace equipped with TDR. Most Carrier furnaces are equipped with TDR.
NOTES:
1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for central air conditioners. Ratings for other
combinations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
EER — Energy Efficiency Ratio
SEER — Seasonal Energy Efficiency Ratio
TDR — Ti m e --- D e l a y R e l a y
TXV — Thermostatic Expansion Valve
24ACA360A30 Outdoor Section With CAP**6024A** Indoor Section
Multipliers for Determining the Performance With Other Indoor Sections
Cooling Indoor
Model
*CAP**6024A**1.001.00
CAP**6021A**0.980.98
CNPH*6024A**0.970.97
CNPV*6024A**0.990.99
CSPH*6012A**0.980.98
FE4ANB0060.990.97
FV4BNB0060.990.97
FX4CN(B,F)0601.011.01
FY4ANB0600.980.98
* Tested combination.
{ Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
} Sensible capacities shown are based on 80˚F(27˚C) entering air at the indoor coil. For sensible capacities at other than 80˚F(27˚C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80˚F(27˚C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80˚F(27˚C).
** Total system kW is total of indoor and outdoor unit kilowatts.
{{ Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240---94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
When the required data fall between the published data, interpolation may be performed.
NOTE: When the required data fall between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
CapacityPowerFurnace Model
CONDENSER ENTERING AIR TEMPERATURES deg F
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
‡
To t a l
System
KW**
Capacity
MBtuh†
To t a l
Sens
‡
To t a l
System
KW**
Cooling Indoor
Model
CAP**6021A**0.970.9758CV(A,X)110 ---20
CSPH*6012A**0.970.9758CV(A,X)110 ---20
CAP**6024A**0.980.9858CV(A,X)135 ---22
CNPH*6024A**0.970.9658CV(A,X)135--- 22
CNPV*6024A**0.970.9758CV(A,X)135--- 22
CSPH*6012A**0.970.9558CV(A,X)135 ---22
CAP**6024A**0.980.9758CV(A,X)155 ---22
CNPH*6024A**0.980.9758CV(A,X)155--- 22
CNPV*6024A**0.980.9758CV(A,X)155--- 22
CSPH*6012A**0.970.9558CV(A,X)155 ---22
Capacity
MBtuh†
To t a l
Sens
‡
To t a l
System
KW**
Capacity
MBtuh†
To t a l
System
CapacityPowerFurnace Model
To t a l
KW**
24ACA3
21
GUIDE SPECIFICATIONS
GENERAL
System Description
Outdoor--mounted, air--cooled, split--system air conditioner
unit suitable for ground or rooftop installation. Unit consists
of a hermetic compressor, an air--cooled coil, propeller--type
condenser fan, and a control box. Unit will discharge supply
air upward as shown on contract drawings. Unit will be used
in a refrigeration circuit to match up to a packaged fan coil
or coil unit.
Quality Assurance
— Unit will be rated in accordance with the latest edition
of ARI Standard 210.
— Unit will be certified for capacity and efficiency, and
listed in t he latest ARI directory.
— Unit construction will comply with latest edition of
ANSI/ASHRAE and with NEC.
— Unit will be constructed in accordance with UL
standards and will carry the UL label of approval. Unit
will have c--UL approval.
24ACA324ACA3
— Unit cabinet will be capable of withstanding Federal
Test Method Standard No. 141 (Method 6061) 500--hr
salt spray test.
— Air--cooled condenser coils will be leak tested at 150
psig and pressure tested at 450 psig.
— Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
— Unit will be shipped as single package only and is
conditioner unit. Contained within the unit enclosure is
all factory wiring, piping, controls, compressor,
refrigerant charge Puronr (R--410A), and special
features required prior to field start--up.
Unit Cabine
s
Fan
t
— Unit cabinet, including louvered coil guard, will be
constructed of galvanized steel, bonderized, and coated
with a powder coat paint.
— Condenser fan will be direct--drive propeller type,
discharging a ir upward.
AIR--COOLED, SPLIT--SYSTEM AIR CONDITIONER
1--1/2 TO 5 NOMINAL TONS
— Condenser fan motors will be totally enclosed, 1--phase
type with class B insulation and permanently lubricated
bearings. Shafts will be corrosion resistant.
— Fan blades will be statically and dynamically balanced.
— Condenser fan openings will be equipped with coated
steel wire safety guards.
Compresso
r
— Compressor will be hermetically sealed.
— Compressor will be mounted on rubber vibration
isolators.
— Compressor will be covered with a sound absorbing
blanket.
Condenser Coi
l
— Condenser coil will be air cooled.
— Coil will be constructed of aluminum fins mechanically
bonded to copper tubes which are then cleaned,
dehydrated, and sealed.
Refrigeration Component
s
— Refrigerationcircuitcomponentswillinclude
liquid--line shutoff valve with sweat connections,
vapor--line shutoff valve with sweat connections,
system charge of Puronr (R--410A) refrigerant, and
compressor oil.
— Unit will be equipped with high--pressure switch, low
pressure switch and filter drier for Puron refrigerant.
Operating Characteristics
— The capacity of the unit will meet or exceed _____
Btuh at a suction temperature of _____ _F. The power
consumption at full load will not exceed _____ kW.
— Combination of the unit and the evaporator or fan coil
unit will have a total net cooling capacity of _____
Btuh or greater at conditions of _____ CFM entering air
temperature at the evaporator at _____ _F wet bulb and
_____ _F dry bulb, and air entering the unit at _____
_F.
— The system will have a SEER of _____ Btuh/watt or
greater at DOE conditions.
Electrical Requirements
— Nominal unit electrical characteristics will be _____ v,
single phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
— Nominal unit electrical characteristics will be _____ v,
three phase, 60 hz. The unit will be capable of
satisfactory operation within voltage limits of _____ v
to _____ v.
— Unit electrical power will be single point connection.
— Control circuit will be 24v.
Special Features
— Refer to section of this literature identifying accessories
and descriptions for specific features and available
enhancements.
24ACA3
Copyright 2006 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Printed in U.S.A.edition date: 07/06
22