Carrier 13 50EZ User Manual

4 (1)
50EZ Comfortr 13 SEER Single---Packaged Heat Pump System with Puron®(R---410A) Refriger ant Single and Thre e Phase 2 --- 5 Nominal Tons (Sizes 024---060)
C99001
Fig. 1 -- Unit 50EZ
NOTE TO EQUIPMENT OWNER:
For your convenience, please record the model a nd serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service.
UNIT INFORMATION
Model # _____________________________________
Serial # ______________________________________
ACCESSORIES (List type and model #)
_____________________________________________
_____________________________________________
_____________________________________________
NOTE TO INSTALLER:
This manual must be left with the equipment owner.
INSTALLATION INFORMATION
Date Installed ________________________________
DEALERSHIP CONTACT INFORMATION
Company Name_______________________________
Address______________________________________
_____________________________________________
Phone Number _______________________________
Technician Name _____________________________
_____________________________________________
1
SAFETY CONSIDERATIONS
Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.
Untrained personnel can perform basic maintenance functionssuch as cleaning and replacing air filters. All other operations must be performed by trained service personnel. When working on this equipment, observe precautions in the literature, on tags, and on la­bels attached to or shipped with the unit and other safety precautions that may apply.
Follow all safety codes. Installation must be in compliance with lo­cal and national building codes. Wear safety glasses, protective clothing, and work gloves. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions included in literature and attached to the unit.
Recognize safety information. This is the safety--alert symbol Whenyou see thissymbolon the unit andin instructionsor manuals, be alert to the potential for personal injury.
Understand these signal words: DANGER, WARNING, and CAU­TION. Th ese words are u sed with the safety--alert symbol. DAN­GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death.CAUTION is used to identify un­safe practices which may resultin minor personal injury or product and property damage.NOTE is used to highlight suggestionswhich
will result in enhanced installation, reliability, or operation.
Note: Installer: This manualshould be left with the equipmentuser.
!
FIRE, EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death, and/or property damage. Installation and servicing of this equipment can be hazardous due to mechanical and electrical components. Only trained and qualified personnel should install, repair, or service this equipment.
!
FIRE,EXPLOSION, ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury, death or property damage.
Do not use this unit if any part has been under water. Immediately call a qualified service technician to inspect the unit and to replace any part of the control system which has been under water.
!
ELECTRICAL SHOCK HAZARD
Failure to follow this warning could result in personal injury or death.
Before performing recommended maintenance, be sure the main power switch to unit is turned off and a lock-- out tag is installed.
WARNING
WARNING
WARNING
!
CAUTION
CUT HAZARD
Failure to follow this caution may result in personal injury.
Sheet metal parts may have sharp edges or burrs. Use care and wear appropriate protective clothing, safety glasses and gloves when handling parts and servicing furnaces.
OPERATING YOUR UNIT
The operation of your heatpump system is controlled by the indoor thermostat. You simply adjust the thermostat and it maintains the in­door temperature at the level you select. Most thermostats of heat pump systems have 3 controls: a temperature control selector, a FAN control, and a SYSTEM or MODE control. Refer to your ther­mostat owner’s manual for more information.
To better protectyour investmentand to eliminate unnecessary ser-
!
!
vice calls, familiarize yourself with the following facts:
1. During heating, increasing the desired temperature setting
more than 2°F(--17°C) may cause the supplemental heaters to be turned on for a short period of time to satisfy the demand. Needless use of the supplementary heat reduces potential energy savings.
2. Ice or frost tends to form on the coil during winter heating operation. Your unit is designed to automatically melt the ice. When in this defrost cycle, it is normal for steam or
fog to rise from the outdoor unit, and for water to drain from the outside of unit. Do not be alarmed!
To start the unit:
1. Turn on the electrical power supply to unit.
2. Set MODE control to desired mode and select temperature.
To shut off unit: Note: If the unit is being shut down because of a malfunction, call
your dealer as soon as possible.
1. Set system MODE control to OFF.
2. Turn off the electrical power supply to unit.
Cooling Mode
With the SYSTEM or MODE control set to COOL, your unit will run in cooling mode until the indoor temperature is lowered to the level you have selected. On extremely hot days, your unit will run for longer periods at a time and have shorter “off” periods than on moderate days.
Heating Mode
With the SYSTEM or MODE control set to HEAT, your unit will run in heating mode until the room temperature is raised to thelevel you have selected. Of course, your unit will run for longer periods to maintain a comfortable environment on cooler days and nights than on moderate ones.
Supplemental Heat
Your unit is your primary heating source. Your system may also be equipped with a supplemental heating source such as electric heat. On cold daysand nights,your system will automatically turn on the supplementalheat,as needed,in order to maintain the levelof com­fort you have selected.
When your heat pump needs additional heat to keep you comfort­able your thermostat will turn on the supplemental heat (if equipped).
Defrost Mode
When your unit is providing heat to your home or officeand the out­door temperature drops below 45°F(7.2°C), moisture may begin to freeze on the surface of the coil. If allowed to build up, this ice would impede airflow across the coil and reduce the amount of heat ab-
2