MultiGard PVC is a multi-cell raceway system for direct burial and concrete
encasement applications. 20' lay length sections of 4" PVC outer shell Type
C, Type 40, or Type 80 have either 3 x 1-1/2" or 4 x 1-1/4" nominal prelubed
PVC innerducts preinstalled.
In addition, all fixed and patented flexible bends utilize "cutthrough"
resistant engineered plastic innerducts" Many other accessories for
terminating, pulling cable, jetting cable, and directional boring are
available.
Features:
• Prelubricated innerducts provide very low coefficient of friction for easy
pulls, and PVC innerducts expand and contract at the same rate as
outerduct.
• Anti-reversing gaskets on coupling body allow for easy joining. Eliminates
need for cementing joints except in boring or jetting applications.
• Jettable using high speed air blowing systems.
• O-ring gasket at base of bell reduces risk of water entering system.
• Inward tapering holes on coupling body give quick and easy innerduct
alignment.
• Print line on outer duct states "Install Print Line Up" to keep system
straight during installation.
• Marked innerduct and marked hole on coupling body ensure proper
innerduct alignment and allow crews to work from opposite directions.
• Terminators for standard, pullthrough, and jetthrough applications.
• Standard and slip sleeve couplings for field cuts and repairs.
• Field repair kit for outershell and innerducts allows repair without taking
cable out of service.
• Transition adaptors allow transition between different outerducts.
• 6" deep bell provides strong joint for field bends.
Standard Multi-Gard supplied with grey and one white tracer innerduct. Add C for
multi-colored innerducts.
(3-cell white/grey/orange) (4-cell white/grey/orange/green)
Multi-Gard fixed bends use the same coupling design as straight sections. All
bends are provided with engineered plastic innerducts to avoid rope cut-through.
Part No.DescriptionPkg. Qty. Wt. ea.
M _ _ _ N4S 4-cell Fixed Bend 1.19 I.D.**
M _ _ _ N35 3-cell Fixed Bend 1.50 I.D.**
Multi-Gard flexible bends use a patented design capable of a 4' minimum bend
radius and use the same coupling design as straight sections and fixed bends.
All bends are provided with engineered plastic innerducts to avoid rope cutthrough.
Part No.DescriptionPkg. Qty. Wt. ea.
M _ F _ 4 _4-cell Flexible Bend 1.19 I.D.**
M _ _ _ N35 3-cell Flexible Bend 1.50 I.D.**
Product
Pos. 1
M = Multi-Cell
Outerduct
Pos. 2
X = Type C
F = Type 40
* Pkg. Qty. and Wt. ea.
Pos. 3
Flexible
Degree and Radius (R)
Pos. 4
B = 126" (Length) 4' x 90°
C = 192" (Length) 6' x 90°
Termination kits allow for sealing inner and outerducts. Each kit contains
innerduct sealing plugs with rope tie. Standard terminators allow for end
terminations, and passs-through (jet-through) terminators allow for bridging
innerducts across a vault to allow for unassisted pulling (or jetting) of cable
through the vault. Box terminators allow end terminations into aboveground
cabinets.
Part No. 4-Cell Part No. 3-Cell Description Pkg. Qty. Wt. ea.
Couplings are provided in standard sleeve for joining two uninstalled plain ends
and slip couplings for male/male connections and repair of unoccupied MultiGard.
Part No.
4-Cell
Part No.
3-CellDescriptionPkg. Qty. Wt. ea.
M _ CC4 M _ CC3 Standard Sleeve Coupling**
M _ SC4 M _ SC3 Slip Coupling**
Drop kit allows Multi-Gard with cable installed to be lowered for newly installed
utilities in a minimum distance using Carlon split-duct. Greatly reduces the cost in
time and manpower especially if concrete encasing afterward.