(KPR) KITCHEN POWER POP-UP RECEPTACLE
Owner’s Operating Instructions
For Catalog Numbers
KPR-15G-BRZ (Bronze), KPR-15G-BRS (Brass) and KPR-15G-NKL (Brushed Nickel)
Voltage: 110-125 VAC – 60hz Current: 15 amp max.
IMPORTANT: Read all instructions before operating KPR Kitchen Power Pop-Up.
WARNING
•
For indoor use only.
• If any malfunction occurs, do not attempt to repair.
• This product has no field serviceable parts.
• Use this product only for its intended uses as described.
• Do not install in line with power converter.
• Do not use attachments not recommended by
manufacturer.
• Do not insert foreign objects into power outlet receptacles.
• For counter top mounting only.
To start using the KPR, simply press downwards on
A C D
the cover, then release hand pressure and the unit will
rise automatically. The power will not be supplied to
the receptacle until the KPR is locked in place.
®
PRESS
DOWNWARDS
TO RAISE COVER
Cover
The KPR unit should
not be retracted
with power cord(s)
still plugged into the
GFCI receptacle.
DO NOT PUSH DOWNWARDS
WITH POWER CORD
PLUGGED IN
UNPLUG AND PUSH
®
Step 1 Step 2
Insert power cord plug to the GFCI Receptacle.
B
®
IMPORTANT: Press the TEST button
(then RESET Button) every month to assure
proper operation.
TROUBLE SHOOTING
If power is not available at the receptacle with the KPR in its
raised position, the Ground Fault Circuit Protection (GFCI) may
have switched the receptacle off. Remove all power cords
from the KPR and receptacles on the same circuit, then push
the GFCI reset button.
If power does not return to receptacle:
• Be sure the KPR is in fully raised and locked position.
• Check the circuit breaker or fuse at the panel box.
If the GFCI continues to trip, contact a qualied electrician as
this is an indication of an electrical fault in the circuit.
After use, remove
any power cord(s)
from the GFCI
receptacle. Push the
unit downwards until
it is ush with the
counter top surface
and it clicks into to
the retracted position.
DOWNWARDS
®
RESET
TEST
RESET
TEST
TA04601 B Page 1 of 2
![](/html/cb/cb16/cb16a69892b3946a95f32b5beb0db40490e3d6174e9c85dfea57b532a42f0439/bg2.png)
T&B Legal Disclaimer:
KPR is co-developed and manufactured between Power Logic in South Africa and Thomas & Betts. Final assembly
is performed at Thomas & Betts Southaven, MS, U.S.A. to the highest international standards, and has been tested
and certied per UL.
WARRANTY: Thomas & Betts sells this product with the understanding that the user will perform all necessary tests to determine the suitability of this product for the
user’s intended application. Thomas & Betts warrants that this product will be free from defects in materials and workmanship for a period of ninety (90) days following
the date of purchase. Upon prompt notification of any warranted defect, Thomas & Betts will, at its option, repair or replace the defective product or refund the purchase
price. Proof of purchase is required. Misuse or unauthorized modification of the product voids all warranties.
Limitations and Exclusions: THE ABOVE WARRANTY IS THE SOLE WARRANTY CONCERNING THIS PRODUCT, AND IS IN LIEU OF ALL OTHER WARRANTIES
EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, WHICH
ARE SPECIFICALLY DISCLAIMED. LIABILITY FOR BREACH OF THE ABOVE WARRANTY IS LIMITED TO COST OF REPAIR OR REPLACEMENT OF THE PRODUCT,
AND UNDER NO CIRCUMSTANCES WILL THOMAS & BETTS BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES.
Thomas & Betts Corporation
Memphis, Tennessee
TA04601 B Page 2 of 2
www.tnb.com
© 2012 Thomas & Betts. All Rights Reserved.