Bore-Gard® Installation - 220 ft.
Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com
Long Island, NY
Pipe Pull Force Data
Maximum 1,560 lbs.
Note: Pull force data generated from self-contained on-board strain gauge and data gathering computer mounted between pipe
2000
Load (lbs)
lead end and reamer. Data samples taken at a rate of 10 per second. See picture below.
NY12798.DAT-TimeHist.Load_cell
]
-500
0 7736.7Time (Secs)
Pulling Eye
attached to
Bore-Gard
ipe
Pull-Force
Measuring
Computer
Left: The data in the graph above was
generated by our state-of-the-art, selfcontained force measuring computer capable
of measuring both tensile and compressive
loads. It is protected by a steel cylinder and
mounted on swivels at both ends. Data was
sampled 10 times per second. This leadingedge technology has enabled Carlon to
determine the actual loading on the pipe as
it is being pulled through the ground. This is
the first known application of such high
technology to the development and
application of pipe for boring applications.
Reamer