Bore-Gard® Installation - 220 ft.
p
Gross Automation (877) 268-3700 · www.carlonsales.com · sales@grossautomation.com
Long Island, NY
Pipe Pull Force Data
Maximum 1,560 lbs.
Note: Pull force data generated from self-contained on-board strain gauge and data gathering computer mounted between pipe
2000
Load (lbs)
lead end and reamer. Data samples taken at a rate of 10 per second. See picture below.
NY12798.DAT-TimeHist.Load_cell
-500 0 7736.7Time (Secs)
Pulling Eye attached to Bore-Gard
ipe
Pull-Force Measuring Computer
Left: The data in the graph above was
generated by our state-of-the-art, self­contained force measuring computer capable of measuring both tensile and compressive loads. It is protected by a steel cylinder and mounted on swivels at both ends. Data was sampled 10 times per second. This leading­edge technology has enabled Carlon to determine the actual loading on the pipe as it is being pulled through the ground. This is the first known application of such high technology to the development and application of pipe for boring applications.
Reamer