CARLO GAVAZZI SV 150, SV 250, SV 160, SV 260 User Manual

Specifications are subject to change without notice (25.06.99) 1
Level Sensors
• Level control for solid, fluid, or granulated substances
• SV 150/250: Max./min. control of DISCHARGING
• SV 160/260: Max./min. control of CHARGING
• Factory-set sensitivity
• 10 A SPDT or 8 A DPDT output relay
• LED-indication: SV 150/250: Power supply and relay ON
SV 160/260: Relay ON
• AC or DC power supply
Product Description
Ordering Key
SV 150 024
Level control relays for capacitive sensors, types VR and VRY. The relays can con-
trol one or two levels of charging (SV 160/260) or dis­charging (SV 150/250).
Housing Output Power supply
Type Selection
Plug Output Function Supply: 24 VAC Supply: 115 VAC Supply: 230 VAC Supply: 24 VDC
Circular SPDT Discharging SV 150 024 SV 150 115 SV 150 230 SV 150 724
DPDT Discharging SV 250 024 SV 250 115 SV 250 230 SV 250 724 SPDT Charging SV 160 024 SV 160 115 SV 160 230 SV 160 724 DPDT Charging SV 260 024 SV 260 115 SV 260 230 SV 260 724
Amplifier, Capacitive Types SV 150/250, SV 160/260
Input Specifications
Sensitivity depends on sensor type
and material
Sensor voltage max. 24 VDC
terminal 6 is negative
Sensor current Activated min. 15 mA, max. 20 mA
Not activated max. < 5 mA
Sensor short-circuit current max. 45 mA
Supply Specifications
General Specifications
Power supply AC-types Overvoltage cat. II (IEC 60664)
Rated operational voltage
through pin 2 & 10 230 230 VAC ± 15%
115 115 VAC ± 15% 024 24 VAC ± 15%
Rated insulation voltage 2.0 kVAC (rms)
Rated impulse withstand
voltage 4 kV (1.2/50 µs)
(line/neutral)
Power supply DC-types Installation cat. II (IEC 60664)
Rated operational voltage 724 24 VDC ±15% (pin 2 pos.) Rated insulation voltage None Rated transient protection volt. 800 V (1.2/50 µs)
Indication for
Output ON LED, red Power supply LED, green
(only SV 150/250)
Environment
Degree of protection IP 20 B Pollution degree 3 (IEC 60664) Operating temperature -20° to +50°C (-4° to +122°F) Storage temperature
-50° to +85°C (-58° to +185°F)
Approvals UL, CSA CE-marking Ye s
SV 160/260SV 150/250
查询SV150024供应商
2 Specifications are subject to change without notice (25.06.99)
Mode of Operation
Max. and/or min. control of solid, fluid or granulated substances, e.g. sand, gravel, sugar or chemicals.
SV 150/250: Relay control of DISCHARGING
SV 160/260: Relay control of CHARGING
Example 1
The diagram shows the level control connected as max. and min. control, i.e. registra­tion of 2 levels during charg­ing (discharging).
The relay releases (operates) when the max. sensor is in contact with the substance,
provided that the min. sensor is immersed. The relay oper­ates (releases) when the min. sensor is no longer in contact with the substance.
Example 1
The diagram shows the level control connected as max. or min. control, i.e. registration
of 1 level during charging (dis­charging).
The relay releases (operates) when the sensor is in contact with the substance.
SV 150/250, SV 160/260
Output Specifications
SV150/SV160 SV250/SV260
Output SPDT relay DPDT relay
Rated insulation voltage 250 VAC (rms) 250 VAC (rms)
(cont./elec.) (Cont./elec., cont./cont.)
Contact ratings (Ag-CdO) µ (micro gap) µ (micro gap)
Resistive loads AC 1 10 A/250 VAC (2500 VAC) 8 A/250 VAC (200 VA)
DC 1 1 A/250 VAC (250 W) 0,4 A/250 VDC (100 W)
or 10 A/25 VDC (250 W) 4 A/25 VDC (100 W)
Small inductive loads AC 15 2.5 A/230 VAC 2.5 A/230 VAC
DC 13 5 A/24 VDC 5 A/24 VDC
Mechanical life 5 x 107operations 5 x 10
7
operations
Electrical life ≥105operations 10
5
operations
Operation frequency 7200 operations/h 7200 operations/h
Insulation voltages
Rated insulation voltage AC 2.0 kVAC (rms) 2.0 kVAC (rms)
(cont./elect.) (cont./elect.)
DC None None
Rated impulse withstand voltage AC 4 kV (1.2/50 µs) 4 kV (1.2/50 µs)
(cont./elect.) (IEC 60664) (cont./elect.) (IEC 60664)
DC 800 V 800 V
Wiring Diagrams
Example 1: Two levels max./min.
Example 2: One level
Power Supply
Power Supply
Max. or Min.
Min.
Max.
Loading...