Carlo Gavazzi SPD 240W 3 phases Data Sheet

Switching Power Supply
Rheinland
ProductSafety
B
a
u
a
r
t
g
e
p
r
ü
f
t
T
y
p
e
a
p
p
r
o
v
e
d
Type SPD 240W 3 phases DIN rail mounting
• Universal AC 3 phases input full range
• Installation on DIN rail 7.5 or 15mm
• PFC as standard
• High efficiency up to 90%
• Power ready output
• Parallel connection feature
• UL, cUL listed and TUV/CE
Product Description
The Switching power supplies SPD series are specially designed to be used in all automation application where the
installation is on a DIN rail and compact dimensions and performance are a must.
Approvals
Output performances
Model
SPD24 SPD48
1)
When powered with three phases input; with biphase input value is in the brackets.
2)
When S/P switch is set to parallel, it is not possible to trim output voltage.
Rated output
Voltage (VDC)
24 240 10 (7.5) 22.5 28.5 17.6 19.4 17.6 19.4 89% 48 240 5 (3.75) 47.0 56.0 37.0 43.0 37.0 43.0 90%
Output
Power (W)
Output
Current
1)
(A)
Voltage Trim
Range
2)
Min. VDC Max. VDC Min. Max. Min. Max.
Output data
Ordering Key
Model Mounting ( D = Din rail ) Output voltage Output power Input Type
Input type: 3 = three phase
DC OK Thereshold
at startup (VDC)
SP D 24 240 3
(or single phase 400/500VAC3))
DC low LED Thereshold
after startup(VDC)
Typical
Efficiency
Line regulation ± 1% Load regulation
Parallel mode ± 5% Non parallel mode ± 1%
Ouput Voltage accuracy
from 0 to +1% (factory adjusted)
Temperature Coefficient +0.02% / °C Hold up time Vi = 230VAC 20ms Minimum load 0% Parallel Operation 2 units max.
(only with S/P switch on “P” position)
Ripple and Noise 100mV
Input data
Rated input voltage 400/500VAC Voltage range
AC in 340 - 575VAC
3)
DC in 480 - 820VDC Rated input current (380/500) 0.85A / 0.7A
3)
Biphase or triphase input (biphase can be: L1 L2, L2 L3 or L1 L3. Note: when used as biphase, the maximum output power is 75% of rated power.
1 Specifications are subject to change without notice.Pictures are just an example. For special features and/or customization, please ask to our sales network. - 0819
Frequency range 47- 63 Hz Inrush current 10A P.F.C. (Vi= 500VAC, Io nom.) 0.6
Switching Power Supply
L1
L3
Y
L2
X
X
X
Note: 1) For 24V Model only
Fuse1
Fuse2
Filter
Filter
Bridge
Rectifier
P.F.C.
Circuit
Switching
Device
Rectifier
Current
Detection
Reference &
Error Amp.
OverVoltage
Detection
Output
Level
Detection
Vo+
Vo-
Single/Parallel Select
Vout Adj.
DCON (Green LED)
DCLOW (Red LED)
RDY 1) (Relay Contact)
Opto-
Isolation
Opto-
Isolation
PWM
Controller
Fuse3
Type SPD 240W 3 phases DIN rail mounting
Controls and Protections
Input Fuse
2.0A/600VAC internal/phase
Overvoltage ProtectionSPD24 30 – 33VDC
SPD48 60 – 68VDC
Output Short Circuit
Continous Current limit
4)
Power ready output (only SPD 24)
Threshold voltages 17.6 - 19.4VDC Contact rating at 60VDC 0.3A insulation 500VDC
Overtemperature 100 - 110°C
Rated Overload Protection 115 - 135%
4)
Not replaceable by user.
General data (@ nominal line, full load, 25°C )
Ambient temperature -25°C to 71°C Derating (>61°C to +71°C) 2.5%/°C Ambient humidity 20 - 95%RH Storage temperature -25°C to +85°C Dimensions L x W x D
Screw terminal type 123.6 x 89.0 x 110.7 mm
4.87 x 3.50 x 4.36 inches
Cooling Free air convection MTBF (MIL-HDBK-217F) n.a. Case material Weight 1.1Kg / 38,80oz Protection degree IP20
Approvals and EMC
(shutdown with auto-restart
when temperature is back
to normal)
Metal (powder painted aluminium)
Insulation voltage I/O 3.000VAC Insulation resistance I/O
@ 500VDC 100M UL / cUL UL508 listed, UL60950-1,
TUV EN60950-1
Block diagrams
0819 - Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 2
Recognized
CE EN61000-6-3
EN55022 class B
EN61000-3-2 EN61000-3-3 EN61000-6-2
EN55024
Loading...
+ 1 hidden pages