This manual is a reference guide for Carlo Gavazzi Smart Configurator. It describes how to set up and use the product
for its intended use.
1.1 Validity of documentation
This manual is valid only for SCTL55 and until any new documentation is published. It describes the function and operation
of the product for its intended use.
1.2 Who should use this documentation
This manual contains all the information you need for commissioning and operating the SCTL55 and must be read and
completely understood by specialized personnel dealing with Configurator.
We highly recommend that you read the manual carefully before starting to use the SCTL55. Save the manual for future
use. The installation manual is intended for qualified technical personnel.
1.3 Safety information
EN
Hospitals, electronic implants
and pacemakers
Radio Interference
Fire hazard
Contact with liquid
Batteries
Shock and impact
Maintenance
General
Do not use or place device near any medical device.
Anyone who is fitted with an electronic implant or pacemaker must hold the device
on the opposite side as a precaution when the device is on.
This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area can cause harmful interference, in
which case the user will be required to correct the interference at his own expense.
Do not leave your device near heat sources such as radiators or cookers.
Do not leave your device charging near flammable materials as there is a risk of fire.
Do not expose the device to liquid or touch it with wet hands. Any damage caused
by liquid may be irreparable.
The device contains Li-ion batteries. Do not disassemble the device. Do not destroy
the batteries. Never use battery that have been damaged. Leave batteries away from
magnetic objects as the latter might cause a short circuit (between the positive and
negative terminals of the batteries) and destroy battery and device. As a general
rule, you shoud not expose the batteries to very high or low temperatures, (below
0°C or above 45°C).
Handle and use your device with the utmost care. Protect your device. Shocks and
impacts may damage it. Part of the device is made of glass and might break if the
device is dropped or is subject to severe impact. Do not touch the display with sharp
objects.
Cleaning: dry cloth only.
Do not disassemble device.
Protection provided by the equipment may be impaired if used in a manner not
specified by the manufacturer
1.4 Service and warranty
Not everybody is authorized to open the Smart Configurator. This operation is reserved exclusively for CARLO GAVAZZI
technical service personnel. Tampering of the SCTL55 by unauthorized personnel voids the warranty.
The SCTL55 is the Industry 4.0 portable, self-powered and user friendly smart configurator for IO-Link sensors that accesses
your sensor data and manages its parameters. There is no need for a PC and dedicated software.
Through a 5.5” HD touchscreen display and dedicated Apps you can now:
• Have access to an advanced diagnostic, showing operating hours, number of detections, operating cycles and alarms
• Verify your sensor status, including current temperature, quality of run and process data
• Easily change the operating sensor parameters to better meet the process requirements (switchpoint mode, sensing
distance, timing functions, PNP/NPN/push-pull, NO/NC). It is also possible to add favourite parameters to the
homepage and create different user profiles (observer, maintainer, specialist).
• Automatically download IODD files, through Wi-fi. As soon as you plug the sensor to one of the 3 connectors on the
top of the device, if the IODD file is not already on the device memory, it automatically connects to the download area
and shows all the data of the sensor.
Thanks to these innovations you can now manage and optimize your sensor very quickly and improve your processes and
predictive maintenance.
ManufacturerCarlo Gavazzi UAB Industri Kaunas
Model numberSCTL55
BodyPolycarbonate
Dimensions (H x L x W)62 x 222 x 90 [mm]
Weight600 g
Screen size5.5”
Shipping weight
(including bag etc.)
800 g
4.2 IO-Link interface
Supply voltage24VDC +/- 20%
Max load80mA/Short circuit protected
SIO2 output testLed indicated SIO2 (Standard Input Output 2) logic state (pull down only)
Incorrect polarity protectionYes
Connectors to sensorPlug types: M8 3-wire, M8 4-wire, M12
IO-Link protocol supportIO-link v1.1
4.3 IODD file administration
WifiDownload IODD file via Configure App
Micro SD card (not inclulded)Import IODD file from Micro SD card
4.4 Configuration file administration
Micro SD card (not inclulded)Save and load device configuration files
Internal memorySave and load device configuration files
4.5 Button function
Battery statusShort press will indicate battery level for 5 sec.
+ (plus)
- (minus)
Power button
Reserved for future use
Hold for 3 sec to power on / off your Smart Configurator
Short press to switch on / off the screen
4.6 Electrical ratings
Standard charger via micro USB5V/1A or PC USB port
4.7 Battery info
Operating time
(connected to sensor)
Standby timeDevice completely off: 6 months
Internal batteries3.8V/10Ah (2x3,5Ah + 3Ah) (LI-ION)
Charge time5V/1A standard charger via USB mini connector: <10 hours
Battery expected lifetime60% capacity after 500 cycles
When the device is connected to power, it flashes from the first LED
Flashing
Steady on
FlashingThe main battery is almost discharged. Please recharge your device
on the left to the other LEDs on the right and indicates that the main
battery is being charged.
After briefly pressing the battery status button, it indicates the status
of the charge of the main battery. Each LED indicates around 20%
of the charge.
Power LED (green)
Steady onThe device is switched on
IO-Link LED (green)
Flashing
Steady onIO-Link communication is established with the IO-Link sensor connected
IO-Link communication is ready, the sensor is not connected or it does
not have IO-Link communication enabled
EN
Error LED (red)
FlashingError (short circuit, data transmission error, overload)
SIO2 LED (orange)
SteadyStatus of the switching input output 2 of the sensor
USB LED (orange)
SteadyMicro USB port is connected to a PC
4.9 Environmental
Operational environmentTo be used in indoor applications only
IP-ratingIP30
Ambient air temperature
Storage temperature0 to + 50°C
Ambient humidity range
Transportation testEN60068-2-31
Drop testEN62368-1:2014, T.7
Pollution degree2
Charging: 10 to + 35°C
Operating: 0 to + 40°C
Operating: 0 to + 90% non condensing
Storage: 0 to + 90% non condensing
EN62368-1
Radio ETSI EN 300 328 v2.1.1
EMC CFR 47 Parts 15.107 & 15.109
Radio CFR 47 Part 15 Subpart C
Contains FCC ID: 2AH8Q-HT17
4.11 Accessories
DC 5V/1A (current limited).
Only suitably rated and approved USB charger should be used with the
Micro USB power adapter
(not included)
Extension cable0.5m M12 to 4 hooks, included
Protective holsterIncluded
LanyardIncluded
Micro USB cableIncluded
Quick start guideIncluded
equipment as per the National Regulations for the country of use. Marked as
LPS (according to IEC 60950-1) or PS2 (according to IEC 62368-1).
Using any other may affect the safety of the equipment.
Contact the manufacturer if in doubt
5. Unboxing
5.1 Switch ON your SCTL55
To switch on your smart configurator, press and hold the power key button for 3 seconds.
5.2 Screen gestures
Touch: touch an item once. For example, touch to select an option
Swipe: swipe your finger on the screen vertically to scroll through a list or horizontally to
Select to turn on the
Wi-Fi and select one of the
networks available from the
list, to connect the device to
internet. If requested, insert the
password
To change the value:
Touch “3” and digit via keypad
the correct value, or...
Swipe horizontally, or...
Touch + or - to change by 1, or
touch + or - to change by 10
Page 17
6.2 Example of capacitive sensor connected
EN
Options
Close Configure App and
back to home screen
Process data
Graphics of set point
Main icons
Favourite parameters
Information:
Please scan the QR code on the right or press the link below to understand all the possible
settings via IO-Link for our capacitive sensors