Specifications are subject to change without notice (30.09.2005) 1
Type Selection
Switching mode Rated operational Control voltage Rated operational Control Power Options
voltage current plug type plug type
A: Zero Switching 23: 230 VACrms A: 24-275 VAC 25 : 25 AACrms M: Spring F: Faston Blank: Basic
48: 480 VACrms D: 4 - 32 VDC 32 : 32 AACrms V: Screw C: Screw HT: Thermal Pad
P: Spring H20: RHS23A*
H21: RHS23B*
* Add suffix ‘H2x’ to RX part no. for mounting of RX unit to heatsink type RHS23A or RHS 23B. For such assemblies, attached derating curve should be consulted
for appropriate selection of operational load current. Note that RX1A...25...H21 version is not available.
• Zero switching (RX1A) AC Solid State Relay
• Direct copper bonding (DCB) technology
• LED indication
• IP 20 protection cover
• Screw, Spring or FASTON terminal options
• Housing free of moulding mass
• 2 input ranges: 4-32 VDC and 24-275 VAC
• Operational ratings up to 32 AACrms and 480 VACrms
• Non-repetitive voltage: Up to 1200 V
p
• Opto-insulation: > 4000 VACrms
• Integrated snubber network
Product Description
The RX ThyReX is an
extremely compact industrial
SSR that is fully pluggable to
make installation and servicing easy. This zero switching
relay can be used for resistive and inductive loads. The
position of the M4 mounting
holes makes this solution
interchangeable with standard hockey-puck relays.
The control plug can have
either screw or spring termi-
nals. The power connection
can be a screw type plug, a
spring type plug or an open
two-spade FASTON solution
that comes with safety covers (no plugs). Both screw
and spring type power plugs
have a specially designed
security leaver to
lock/unlock. To facilitate
assembly, the RX ThyReX
can be ordered with its own
thermal pad (optional).
Solid State Relay
Number of poles
Switching mode
Rated operational voltage
Control voltage
Rated operational current
Control plug type
Power plug type
Options
Ordering Key
Solid State Relays
Industrial, 1-Phase ZS, Fully Pluggable
Type RX1A
RX 1 A 48 D 32 M P HT
General Specifications
RX1A23.. RX1A48..
Operational voltage range 24 to 265 VACrms 42 to 552 VACrms
Non-rep. peak voltage ≥ 650 V
p
≥ 1200 V
p
Zero voltage turn-on ≤ 10 V ≤ 10 V
Operational frequency range 45 to 65 Hz 45 to 65 Hz
Power factor
> 0.5 @ 230 VACrms > 0.5 @ 480 VACrms
Pollution degree
RX1A...D... 3 3
RX1A...A... 2 2
Approvals UL, CSA UL, CSA
CE-marking Yes Yes
Rated insulation voltage
Input to output ≥ 4000 VACrms
Output to case ≥ 4000 VACrms
Insulation
Operating temperature -30° to +70°C (-22˚ to +158˚F)
Storage temperature -40° to +80°C (-40˚ to +176˚F)
Junction temperature ≤ 125˚C (257˚F)
Thermal Specifications