59
CARLO GAVAZZI Automation Components Specifications are subject to change without notice.
Soft starting and stopping
of 3-phase motors.
Starting / stopping time and
initial torque can be
independently adjusted by builtin potentiometers. Switching of
1-phase transformers to
minimise inrush current.
Soft Starter
Dimensions (mm) H x W x D
Features
Control Specifications
Control input range
Max. input current
Rated insulation voltage
Dielectric voltage
Inpulse withstand volt.
Output Specifications
Rated operational current
Overload current profile
Operational voltage
General Specifications
Frequency range
Ramp up / Ramp down
Initial torque
Kick-start
Ramp profiles
Over-temp. protection
Relay output
Connections
Capacity max. power
Capacity max. control
Operating temperature
Storage temperature
Degree of protection
Approvals/Marks
References
Motor Control:
3-phase/2-pole switching
Transformer switching:
1 pole switching
Types
* Other options available on request: Single pole up to 12 A/400 V/4.7 kW (RSE..-BS), Relay output on 25 A 400 V/15 kW (RSE..-C10).
Motor Control - Soft Start and Stop Transformer
2 Pole Switching Switching
RSE..-B RSE..-C RSE..-CR1 TSE..
80 x 90 x 103
User selected ramp
profiles
A1-A2: 24-110VAC/DC
A1-A3: 110-480VAC
A1-A2: 12 mA
A1-A3: 5 mA
630 Vm
2 kVrms
4 kV (1.2/50 µs)
AC53b: integral bypassing of semiconductor
25 A
25 A:AC-53b:4-3:120
127/220 Vrms [RSE22..]
230/400 Vrms [RSE40..]
227/480 Vrms [RSE48..]
346/600 Vrms [RSE60..]
50-60 Hz
0.5-20s / 0.5-20s
50%±5% on max.
5 % on min.
200 ms
Pump compressor
Yes
Over-temperature
End of ramp
Wrong phase sequence
Screw terminals
10 mm or 2x 6 mm
2.5 mm
-20°C to +50°C
-50°C to +85°C
IP 20
CE - UL - CSA
25 A
RSE2225-CR1
(5.5 kW)
RSE4025-CR1
(11 kW)
RSE2485-CR1
(15 kW)
RSE6025-CR1
(15 kW)
80 x 45 x 103
Reduces inrush
current
4-32 VDC
12 mA
AC51: <16 A
AC51: >16 A
with external thyristor
module
90/135 Vrms [TSE.110.]
160/270 Vrms [TSE.230.]
280/440 Vrms [TSE.400.]
350/550 Vrms [TSE.480.]
45-65 Hz
Trasformer selector
Load can be single
phase transformer with
El-cut strip-wound core
or toroidal core with any
secondary load or it can
be a parallel connection
of different types of
1- phase transformers
Screw terminals
2.5 mm
2.5 mm
0°C to +50°C
-50°C to +85°C
IP 20
CE
16 A
TSE6-1A1113100
TSE6-1A2113100
TSE6-1A3113100
TSE6-1A4113100
30 A / 50 A / 63 A
TSE6-1A1213100
TSE6-1A2213100
TSE6-1A3213100
TSE6-1A4213100
80 x 90 x 103
Up to 11.0 kW
at 400VAC
A1-A2: 24-110VAC/DC
A1-A3: 110-480VAC
A1-A2: 12 mA
A1-A3: 5 mA
630 Vm
2 kVrms
4 kV (1.2/50 µs)
AC53b: integral bypassing of semiconductor
25 A
25 A:AC-53b:4-3:120
127/220 Vrms [RSE22..]
230/400 Vrms [RSE40..]
227/480 Vrms [RSE48..]
346/600 Vrms [RSE60..]
50-60 Hz
0.5-10s / 0.5-20s
50%±5% on max.
5 % on min.
No
General purpose
Yes
No
Screw terminals
10 mm or 2x 6 mm
2.5 mm
-20°C to +50°C
-50°C to +85°C
IP 20
CE - UL - CSA
25 A
RSE2225-C
(5.5 kW)
RSE4025-C
(11 kW)
RSE4825-C
(15 kW)
RSE6025-C
(15 kW)
80 x 45 x 103
Up to 5.5 kW
at 400VAC
A1-A2: 24-110VAC/DC
A1-A3: 110-480VAC
A1-A2: 12 mA
A1-A3: 5 mA
630 Vm
2 kVrms
4 kV (1.2/50 µs)
AC53b: integral bypassing of semiconductor
3 A [RSE..03..]
12 A [RSE..12..]
3 A:AC-53b:3-5:30
12 A:AC-53b:3-5:180
127/220 Vrms [RSE22..]
230/400 Vrms [RSE40..]
227/480 Vrms [RSE48..]
346/600 Vrms [RSE60..]
50-60 Hz
0.5-7.5s / 0.5-10s
70-100% on max.
5 % on min.
No
General purpose
No
No
Screw terminals
2 x 2.5 mm x 4
2 x 2.5 mm x 4
-20°C to +50°C
-50°C to +85°C
IP 20
CE - UL - CSA
3 A
RSE2203-B
(0.55 kW)
RSE4003-B
(1.1 kW)
RSE4803-B
(1.5 kW)
RSE6003-B
(2.2 kW)
12 A
RSE2212-B
(3.0 kW)
RSE4012-B
(5.5 kW)
RSE4812-B
(5.75 kW)
RSE6012-B
(0.55 kW)