Carlo Gavazzi RP1A, RP1B Catalog Page

Specifications are subject to change without notice (30.09.2005) 1
Solid State Relays PCB, 1-Phase ZS/IO Types RP1A, RP1B
•AC Solid State Relay for PCB mounting
•Zero switching or instant-on
•Rated operational current: 3, 5 or 5.5 AACrms
•Surface mount technology
•Flexible encapsulation for extended life
•Control voltage: 3 to 32 VDC* / 16 to 32 VAC**
•Opto-isolation: > 4000 VACrms
•Non-repetitive peak voltage: Up to 1000 V
p
•Non-repetitive surge current: Up to 250 A
p
Product Description
Ordering Key
Solid State Relay (PCB) Number of poles Switching mode Rated operational voltage Control voltage Rated operational current
Rated operational Non-rep. voltage Control voltage Rated operational current voltage 3 AACrms 5 AACrms 5.5 AACrms
230 VACrms 650 Vp 3 to 32 VDC RP1A23D3 RP1A23D5 RP1A23D6
RP1B23D3 RP1B23D5 RP1B23D6
16 to 32 VAC - - RP1A23A6
400 VACrms 850 Vp 3 to 32 VDC RP1A40D3 RP1A40D5 RP1A40D6
4 to 32 VDC RP1B40D3 RP1B40D5 RP1B40D6
480 VACrms 1000 Vp 4 to 32 VDC RP1A48D3 RP1A48D5 RP1A48D6
RP1B48D3 RP1B48D5 RP1B48D6
Switching mode Rated operational voltage Rated operational current Control voltage
A: Zero switching 23: 230 VACrms 3: 3 AACrms D: 3 to 32 VDC* B: Instant-On switching 40: 400 VACrms 5: 5 AACrms A: 16 to 32 VAC**
48: 480 VACrms 6: 5.5 AACrms
* 4 to 32 VDC for RP1A48..
4 to 32 VDC for RP1B40.. and RP1B48..
** Only available for 230V, 5.5 A
Type Selection
Selection Guide
RP 1 A 23 D 3
The RP1 is an SSR series for socket- or PCB-mounting, providing an ideal interface between logic controls and AC loads. The RP1 is designed for resistive and inductive loads up to 480VACrms. Two regulated control voltage ranges cover most standard input require­ments in an economic pack­age. These features allow a direct substitution of existing PCB mounted relays with RP1. Internally this new series enjoys an improved technical design with the introduction of stress-free flexible encapsula­tion and automated assembly
of components. Opto-isola­tion and load switching are performed by individual com­ponents, providing higher reli­ability than monolithic designs. Additionally RP1..6 is a special version with high current surge capability that reduces fusing requirements. This relay can also drive high­er AC53a loads up to 5 A. The Solid State technology used can withstand peak volt­ages of 1000V, making the RP1 series suitable to drive AC loads such as valve solenoids and small induction motors.
Rated operational Non-rep. voltage Control voltage Rated operational current voltage 3 AACrms 5 AACrms 5.5 AACrms
230 VACrms 650 Vp 5 to 34 VDC RP1A23D3M1 RP1A23D5M1 RP1A23D6M1*
RP1B23D3M1 RP1B23D5M1 RP1B23D6M1
16 to 32 VAC - - RP1A23A6M1
* For operational voltages 230 VACrms add suffix M2 to part no.
Selection Guide (mounted on DIN EN adaptor)
2 Specifications are subject to change without notice (30.09.2005)
Insulation Input - Output
Insulation resistance 1010Ω Insulation capacitance 8 pF
RP 1
RP1....3 RP1....5 RP1....6
Rated operational current
AC 51 @ T
a
= 25ºC 3 A 5 A 5.5 A
AC 53a @ Ta= 25ºC 2 A 3 A 5 A Min. operational load current 20 mA 20 mA 20 mA Rep. overload current t=1 s 10 AACrms 12 AACrms 16 AACrms Non-rep. surge current t=20 ms 65 A
p
80 A
p
250 A
p
Off-state leakage current < 1 mA < 1 mA < 1 mA I2t for fusing t=10 ms 20 A2s 50 A2s 340 A2s Critical dI/dt @ 50 Hz 50 A/µs 20 A/µs 20 A/µs Critical dV/dt off state min. 250 V/µs 500 V/µs 500 V/µs On-state voltage drop
@ rated current < 1.2 Vrms < 1.2 Vrms < 1.2 Vrms
Output Specifications
Operating temperature
-20° to +70°C (-4° to +158°F)
Storage temperature
-40° to +100°C (-40° to +212°F)
Thermal Specifications
RP1...A. RP1A23A6
Control voltage 16 - 32 VAC
RP1.23.. RP1A40.. 3-32 VDC -
RP1B40.. RP1.48.. 4-32 VDC ­Pick-up voltage 10 VAC
RP1.23.. RP1A40.. 2.8 VDC -
RP1B40.. RP1.48.. 3.8 VDC ­Drop-out voltage 1.2 VDC 5 VAC Max. input curent 13 mAAC
RP1A... 10 mADC -
RP1B... 15 mADC ­Max. reverse voltage 32 VDC ­Response time pick-up
RP1A... < 10 ms -
RP1B... 12 VDC/ 50 Hz < 160 µs -
5 VDC/ 50 Hz < 320 µs -
Response time drop-out < 20 ms
RP1A... < 10 ms -
RP1B... < 10 ms -
Input Specifications
RP1.23.. RP1.40.. RP1.48..
Operational voltage range
RP1A... 12 - 265 VACrms 20 - 440 VACrms 20 - 530 VACrms
RP1B... 12 - 265 VACrms 12 - 440 VACrms 12 - 530 VACrms Non-rep. peak voltage 650 V
p
850 V
p
1000 V
p
Rated insulation input to output 4 kVACrms 4 kVACrms 4 kVACrms Operational frequency range 45 - 65 Hz 45 - 65 Hz 45 - 65 Hz Power factor > 0.5 > 0.5 > 0.5 Zero voltage turn-on < 10 V < 10 V < 10 V Approvals UL, cUL, VDE* UL, cUL, VDE* UL, cUL, VDE* CE-marking Yes Yes Yes
* VDE 0700, VDE 0805 (excluding RP1A23A6)
General Specifications
Loading...