Carlo Gavazzi RMI. 4-5 5A Catalog Page

8 Specifications are subject to change without notice
Type Terminal version Contact code Rated coil voltage DC / AC
Terminal version: A = Soldering terminals
Nominal Pick-up Drop-out Coil
voltage voltage voltage resistance
VDC VDC VDC
5 4.0 0.5 27.5 ±10%
6 4.8 0.6 40.0 ±10% 12 9.6 1.2 160.0 ±10% 24 19.2 2.4 650.0 ±10% 48 38.4 4.8 2600.0 ±15%
110 88.0 11.0 11000.0 ±15%
Midi Industrial Relay Type RMI. 4-5 5A Monostable
• High switching power
• Small size
• Wide range of application
• 5 A switching capacity
• 4 poles configuration
• AC coils 6 to 230 VAC
• DC coils 5 to 110 VDC
• 1.5 KV dielectric coil to contacts
• Au-clad contact available
• Conform to the CE low voltage directive
• UL, VDE, CSA approved
• Standard with LED, Push with arm and Flag
RMI. 4-5 5A
- Lift-Elevators
- Mooving Stairs
- Textile machines
- Wood working machines
- Plastic molding machines
- Ceramic working machines
Product Application
Ordering Key
Contact code
4-5
Contact rating
5 A
Contact configuration
4 change over contacts (4PDT {4-form C})
Type Selection
Coil Characteristics, DC (20°C)
Nominal Pick-up Drop-out Coil
voltage voltage voltage resistance
VAC VAC VAC
6 4.8 1.8 11.5 ±10% 12 9.6 3.6 46.0 ±10% 24 19.2 7.2 184.0 ±10% 48 38.4 14.4 735.0 ±10%
115/120 96.0 36.0 4550.0 ±15%
230 176.0 66.0 14400.0 ±15%
Coil Characteristics, AC (20°C)
Contact Characteristics
Contact rating (with resistive load) 5 A - 250 VAC
Usually rating 5 A - 250 VAC / 30 VDC
1 x 105ops
Max. rating 6 A - 250 VAC / 30 VDC
5 x 104ops
Material Silver alloy Initial contact resistance 50 m(at 1 A 6 VDC)
Current Max. switching current 5 A
Voltage
Max. switching voltage 250 VAC / 30 VDC Max. switching power 150 W - 1250 VA
Life Electrical life 1x10
5
ops (1800 ops/h)
Mechanical life 1x10
7
ops (18000 ops/h)
RMI A 4-5 012 DC
Specifications are subject to change without notice 9
Midi Industrial Relay Type RMI. 4-5 5A Monostable
Insulation
Test Voltage (1 min.) Between coil and contacts 1000 VAC Between open contacts 1000 VAC
General Data
Nominal coil power 0.9 W DC / 1.2 VA AC Operating time
(At nominal voltage) 25 ms Release time
(At nominal voltage) 25 ms Ambient temperature -55° C to +70° C Vibration resistance 10 to 55 Hz 1.5 mm
Between contacts sets 1500 VAC Initial insulation resistance 1.000 M- 500 VAC
Shock resistance
Funktional 100 m/s
2
Destructive 1000 m/s
2
Humidity 35% to 95% Termination PCB and AMP Construction Dust cover Weight ~ 37 g
Dimensions
4.5
21.5
36
5.3 3.5
28
2.2 x 0.5
1 x 0.5
4
RMI . 4-5 . . . RMI . 4-5 . . .
Pin View
13.2
6.4
6.3 16.8
12.7
4.4
Ø 1.3
Only for PCB terminals
Wiring Diagram
Diagrams
13 9 5 1
A1 11 14 12
10 6 2
21 24 22
11 7 3
31 34 32
14 12 8 4
A2 41 44 42
RMI . 4-5 . . .
Approvals
The approvals stated are not generally applicable to all the relay versions.
For further information please apply for relevant data sheets ref.
3.84.00.10.x
10,8 0,6 0,4 0,2
0,6
0,8
1
F
0,4
cosϕ
F
Power factor
Power factor
1 Electrical life reduction factor at
AC inductive load
0 20 40 60 80 100 120 140 160 180 200 220 250
0,1
0,2
0,3
0,4
0,5
0,6
1
2
3
4
5
0,7
DC voltage (V)
DC current (A)
2 Maximum DC resistive load
breaking capacity
Soldering Terminals PCB Terminals
U.S.A. CANADA GERMANY ITALY
Loading...