Carlo Gavazzi RM 23, RM 40, RM 48, RM 60 Catalog Page

Specifications are subject to change without notice (30.09.2005) 1
Rated opera- Non-rep. Control Rated operational current tional voltage voltage voltage 25A 50A 75A 100A
230VACrms 650V
p
3 - 32VDC RM1A23D25 RM1A23D50 RM1A23D75 RM1A23D100 20 to 280VAC RM1A23A25 RM1A23A50 RM1A23A75 RM1A23A100
400VACrms 850V
p
4 - 32VDC RM1A40D25 RM1A40D50 RM1A40D75 RM1A40D100 20 to 280VAC RM1A40A25 RM1A40A50 RM1A40A75 RM1A40A100
480VACrms 1200V
p
4 - 32VDC RM1A48D25 RM1A48D50 RM1A48D75 RM1A48D100 20 to 280 VAC RM1A48A25 RM1A48A50 RM1A48A75 RM1A48A100
600VACrms 1400V
p
4 - 32VDC RM1A60D25 RM1A60D50 RM1A60D75 RM1A60D100 20 to 280VAC RM1A60A25 RM1A60A50 RM1A60A75 RM1A60A100
• Zero switching (RM1A) or instant-on switching (RM1B) AC Solid State Relay
• Direct copper bonding (DCB) technology
• LED indication
• Built-in varistor 230, 400, 480, 600V
• Clip-on IP 20 protection cover
• Self-lifting terminals
• Housing free of moulding mass
• 2 input ranges: 3-32* VDC and 20-280VAC/22-48VDC
• Operational ratings: Up to 100AACrms and 600VACrms
• Non-repetitive voltage: Up to 1400V
p
• Opto-insulation: > 4000VACrms
Product Description
The industrial, 1-phase relay with antiparallel thyristor out­put is the most widely used industrial SSR due to its mul­tiple application possibilities. The relay can be used for resistive, inductive and capacitive loads. The zero switching relay switches ON when the sinusoidal curve crosses zero and switches OFF when the current cross­es zero. The instant-on relay
Solid State Relay Number of poles Switching mode Rated operational voltage Control voltage Rated operational current
Ordering Key
Solid State Relays
with DC control input can be used for phase control. The built-in varistor secures tran­sient protection for the heavy industrial applications, and the LED indicates the status of the control input. The clip­on cover is securing touch protection to IP 20. Protect­ed output terminals can han­dle cables up to 16mm
2
.
Type Selection
Switching mode Rated operational Control voltage Rated operational
voltage current
A: Zero Switching 23: 230VACrms A: 20-280VAC/22-48VDC 25: 25AACrms B: Instant-on switching 40: 400VACrms D: 3-32VDC* 50: 50AACrms (DC Control only) 48: 480VACrms
*4 to 32VDC for 400, 480 and 600VAC types 75: 75AACrms
60: 600VACrms
*4 to 32VDC for RM1B types 100: 100AACrms
Selection Guide
Industrial, 1-Phase ZS (IO) w. LED and Built-in Varistor Types RM 23, RM 40, RM 48, RM 60
RM 1 A 23 D 25
2 Specifications are subject to change without notice (30.09.2005)
Input Specifications
RM1A, RM1B
Output Specifications
RM1....25 RM....50 RM1....75 RM1....100
Rated operational current
AC51 @ Ta=25°C 25Arms 50Arms 75Arms 100Arms AC53a @ Ta=25°C 5Arms 15Arms 20Arms 30Arms
Min. operational current 150mA 150mA 150mA 150mA Rep. overload current t=1 s < 55AACrms < 125AACrms < 150AACrms < 200AACrms Non-rep. surge current t=10 ms 300A
p
580A
p
1150A
p
1900A
p
Off-state leakage current @ rated voltage and frequency < 3mArms < 3mArms < 3mArms < 3mArms
I2t for fusing t=1-10 ms < 450 A2s < 1680A2s < 6600A2s < 18000A2s Critical dI/dt 50A/µs 50A/µs 100A/µs 100A/µs On-state voltage drop @ rated current 1.6Vrms 1.6Vrms 1.6Vrms 1.6Vrms Critical dV/dt off-state min. 1000V/µs 1000V/µs 1000V/µs 1000V/µs
General Specifications
RM1...D.. RM1...A..
Control voltage range
RM1A23... 3 - 32VDC 20 - 280VAC, 22 - 48VDC RM1A40... RM1A48... RM1A60... 4 - 32VDC 20 - 280VAC, 22 - 48VDC RM1B... 4 - 32VDC -
Pick-up voltage @ Ta = 25˚C
RM1A23... 2.5VDC 18VAC/DC RM1A40... RM1A48... RM1A60... 3.5VDC 18VAC/DC RM1B ... 3.5VDC -
Reverse voltage 32VDC - Drop out voltage 1.2VDC 6VAC/DC Input current @ max input voltage
RM1A 12 mA 20mA RM1B 15 mA -
Response time pick-up
RM1A 1/2 cycle 12ms RM1B 0.1ms -
Response time drop-out 1/2 cycle 40ms
RM1.23... RM1.40... RM1.48... RM1.60...
Operational voltage range
RM1A... 24 to 265VACrms 42 to 440VACrms 42 to 530VACrms 42 to 660VACrms RM1B... 42 to 265VACrms 42 to 440VACrms 42 to 530VACrms 42 to 660VACrms
Non-rep. peak voltage 650V
p
850V
p
1200V
p
1400V
p
Zero voltage turn-on 10V 10V 10V 10V Operational frequency range 45 to 65Hz 45 to 65Hz 45 to 65Hz 45 to 65Hz Power factor
> 0.5 @ 230VACrms > 0.5 @ 400VACrms > 0.5 @ 480VACrms > 0.5 @ 600VACrms
Approvals UL, cUL, CSA UL, cUL, CSA UL, cUL, CSA UL, cUL, CSA CE-marking Yes Yes Yes Yes *
* Heatsink must be connected to ground
Loading...
+ 3 hidden pages