Carlo Gavazzi RJ1P Data Sheet

Rated operational Non-rep. voltage Control input Supply voltage Rated operational voltage current (50 A)
230VACrms 650Vp 0 - 10VDC 24VAC/DC RJ1P23V50E
4 - 20mA RJ1P23I50E
480VACrms 1200Vp 0 - 10VDC 24VAC/DC RJ1P48V50E
4 - 20mA RJ1P48I50E
600VACrms 1200Vp 0 - 10VDC 24VAC/DC RJ1P60V50E
4 - 20mA RJ1P60I50E
Solid State Relay Number of poles Switching mode (Proportional) Rated operational voltage Control input type Rated operational current Terminal layout
Specifications are subject to change without notice (30.09.2005) 1
• AC semiconductor contactor
• Multi-function - 5 selectable modes of operation: Phase Angle, Distributed Full Cycle and Burst Control (1, 3 and 10s)
• Direct copper bonding (DCB) technology
• LED-indication for control and load status
• Operational ratings up to 50 AACrms and 600 VAC
• 4-20mA or 0-10V control input
• Built-in varistor
• Non-repetitive voltage: Up to 1200Vp
• Opto-isolation > 4000VACrms
• Cage clamp terminals
• IP20 protection
Product Description
Ordering Key
The Solitron Midi Analog Switching is a single-phase SSR that provides proportional output power in relation to the control signal level applied. This microprocessor-based device provides for 5 different switching modes integrated into one package. A selector switch on the front of the device is used for the selection of the preferred mode of oper­ation, i.e., either Phase Angle, Distributed Full Cycle or Burst
Control. This multi-function selection makes this device ideal for the control of a variety of loads, including heaters and lamps. The control signal can be either 4 - 20mA or 0 ­10VDC. 4mA or 0V correspond to zero output power, whilst 20mA or 10VDC correspond to full output power. The product is ready to mount on DIN-rail or chassis and comes with integral heatsink.
Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P
Type Selection
Switching Rated operational Control Rated operational Terminal mode voltage input current layout
P: Proportional 23: 230VACrms V: 0 - 10VDC 50: 50AACrms E: Contactor
Output 48: 480VACrms I: 4 - 20mA
60: 600VACrms
Selection Guide
RJ 1 P 48 V 50 E
Thermal Specifications
Operating temperature -20 to +60ºC (-4 to +140 ˚F) Storage temperature -40 to +100ºC (-40 to +212 ˚F)
Insulation
Rated insulation voltage
Input to output 4000 VACrms Output to case 4000 VACrms
RJ1P23... RJ1P48... RJ1P60...
Operational voltage range 90 to 265VAC 200 to 550VAC 410 to 660VAC Non-rep. peak voltage 650V
p
1200V
p
1200V
p
Operational frequency range 45 to 65Hz 45 to 65Hz 45 to 65Hz Output power 0 to 99% 0 to 99% 0 to 99% Power factor 0.9 @ 230VACrms 0.9 @ 480VACrms 0.9 @ 600VACrms Load status indication Red LED Red LED Red LED Output power resolution
MODE 1 Phase Angle 1/300 @ 50Hz, 1/300 @ 60Hz MODE 2 Full Cycle 1/64 @ 50Hz, 1/64 @ 60Hz MODE 3 Burst with 1s period 1/50 @ 50Hz, 1/60 @ 60Hz MODE 4 Burst with 3s period 1/150 @ 50Hz, 1/180 @ 60Hz
MODE 5 Burst with 10s period 1/500 @ 50Hz, 1/600 @ 60Hz Approvals UL, cUL CE-marking
Ye s
RJ1P..I...
Current controlled input
Control current range 4 - 20mA Max. allowable input current 50mA Pick up current 4.2mA Drop out current 3.9mA Control status indication Green LED Reverse polarity protected Yes Voltage drop 10VDC @ 20mA
RJ1P..V...
Voltage controlled input
Supply voltage range, Vss 20 - 28VAC/DC Supply current 18mA @ 24VDC
23mA @ 24VAC Control voltage range, Vcc 0 - 10VDC Control input current 0.1mA @ 10VDC Reverse polarity protected Yes Pick up voltage 0.5VDC Drop out voltage 0.05VDC Control status indication Green LED
2 Specifications are subject to change without notice (30.09.2005)
RJ1P
Input Specifications
General Specifications
Weight Approx. 430 g Housing material PBT Flame retardant Control terminal cable size
Min 1 x 0.5 mm
2
(1 x AWG20)
Max 1 x 4.0 mm
2
(1 x AWG12) or
2 x 2.5 mm
2
(2 x AWG14)
Mounting torque max. 0.6 Nm Posidriv 0 bit
Control terminal screw M3
Power terminal cable size
Min 1 x 4 mm
2
(1 x AWG12)
Max 1 x 25 mm
2
(1 x AWG3) or
2 x 10 mm
2
(2 x AWG6)
Mounting torque max. 2.5 Nm Posidriv 2 bit
Power terminal screw M5
Housing Specifications
Output Specifications
Rated operational current
AC51 @Ta=25ºC 50AACrms Min. operational current 150mAACrms Rep. overload current t=1 s
(Tj init.=25°C) < 200AACrms Non-rep. surge current t=10 ms
(Tj init.=25°C) 1900A
p
Off-state leakage current, @ rated voltage and frequency < 3 mArms I2t for fusing t=10 ms 18000A2s
On-state voltage drop @ rated current 1.6Vrms
Critical dV/dt off-state 1000V/µs