Carlo Gavazzi RJ1P Data Sheet

Rated operational Non-rep. voltage Control input Supply voltage Rated operational voltage current (50 A)
230VACrms 650Vp 0 - 10VDC 24VAC/DC RJ1P23V50E
4 - 20mA RJ1P23I50E
480VACrms 1200Vp 0 - 10VDC 24VAC/DC RJ1P48V50E
4 - 20mA RJ1P48I50E
600VACrms 1200Vp 0 - 10VDC 24VAC/DC RJ1P60V50E
4 - 20mA RJ1P60I50E
Solid State Relay Number of poles Switching mode (Proportional) Rated operational voltage Control input type Rated operational current Terminal layout
Specifications are subject to change without notice (30.09.2005) 1
• AC semiconductor contactor
• Multi-function - 5 selectable modes of operation: Phase Angle, Distributed Full Cycle and Burst Control (1, 3 and 10s)
• Direct copper bonding (DCB) technology
• LED-indication for control and load status
• Operational ratings up to 50 AACrms and 600 VAC
• 4-20mA or 0-10V control input
• Built-in varistor
• Non-repetitive voltage: Up to 1200Vp
• Opto-isolation > 4000VACrms
• Cage clamp terminals
• IP20 protection
Product Description
Ordering Key
The Solitron Midi Analog Switching is a single-phase SSR that provides proportional output power in relation to the control signal level applied. This microprocessor-based device provides for 5 different switching modes integrated into one package. A selector switch on the front of the device is used for the selection of the preferred mode of oper­ation, i.e., either Phase Angle, Distributed Full Cycle or Burst
Control. This multi-function selection makes this device ideal for the control of a variety of loads, including heaters and lamps. The control signal can be either 4 - 20mA or 0 ­10VDC. 4mA or 0V correspond to zero output power, whilst 20mA or 10VDC correspond to full output power. The product is ready to mount on DIN-rail or chassis and comes with integral heatsink.
Solid State Relays SOLITRON MIDI Multi-Function Analog Switching Type RJ1P
Type Selection
Switching Rated operational Control Rated operational Terminal mode voltage input current layout
P: Proportional 23: 230VACrms V: 0 - 10VDC 50: 50AACrms E: Contactor
Output 48: 480VACrms I: 4 - 20mA
60: 600VACrms
Selection Guide
RJ 1 P 48 V 50 E
Thermal Specifications
Operating temperature -20 to +60ºC (-4 to +140 ˚F) Storage temperature -40 to +100ºC (-40 to +212 ˚F)
Insulation
Rated insulation voltage
Input to output 4000 VACrms Output to case 4000 VACrms
RJ1P23... RJ1P48... RJ1P60...
Operational voltage range 90 to 265VAC 200 to 550VAC 410 to 660VAC Non-rep. peak voltage 650V
p
1200V
p
1200V
p
Operational frequency range 45 to 65Hz 45 to 65Hz 45 to 65Hz Output power 0 to 99% 0 to 99% 0 to 99% Power factor 0.9 @ 230VACrms 0.9 @ 480VACrms 0.9 @ 600VACrms Load status indication Red LED Red LED Red LED Output power resolution
MODE 1 Phase Angle 1/300 @ 50Hz, 1/300 @ 60Hz MODE 2 Full Cycle 1/64 @ 50Hz, 1/64 @ 60Hz MODE 3 Burst with 1s period 1/50 @ 50Hz, 1/60 @ 60Hz MODE 4 Burst with 3s period 1/150 @ 50Hz, 1/180 @ 60Hz
MODE 5 Burst with 10s period 1/500 @ 50Hz, 1/600 @ 60Hz Approvals UL, cUL CE-marking
Ye s
RJ1P..I...
Current controlled input
Control current range 4 - 20mA Max. allowable input current 50mA Pick up current 4.2mA Drop out current 3.9mA Control status indication Green LED Reverse polarity protected Yes Voltage drop 10VDC @ 20mA
RJ1P..V...
Voltage controlled input
Supply voltage range, Vss 20 - 28VAC/DC Supply current 18mA @ 24VDC
23mA @ 24VAC Control voltage range, Vcc 0 - 10VDC Control input current 0.1mA @ 10VDC Reverse polarity protected Yes Pick up voltage 0.5VDC Drop out voltage 0.05VDC Control status indication Green LED
2 Specifications are subject to change without notice (30.09.2005)
RJ1P
Input Specifications
General Specifications
Weight Approx. 430 g Housing material PBT Flame retardant Control terminal cable size
Min 1 x 0.5 mm
2
(1 x AWG20)
Max 1 x 4.0 mm
2
(1 x AWG12) or
2 x 2.5 mm
2
(2 x AWG14)
Mounting torque max. 0.6 Nm Posidriv 0 bit
Control terminal screw M3
Power terminal cable size
Min 1 x 4 mm
2
(1 x AWG12)
Max 1 x 25 mm
2
(1 x AWG3) or
2 x 10 mm
2
(2 x AWG6)
Mounting torque max. 2.5 Nm Posidriv 2 bit
Power terminal screw M5
Housing Specifications
Output Specifications
Rated operational current
AC51 @Ta=25ºC 50AACrms Min. operational current 150mAACrms Rep. overload current t=1 s
(Tj init.=25°C) < 200AACrms Non-rep. surge current t=10 ms
(Tj init.=25°C) 1900A
p
Off-state leakage current, @ rated voltage and frequency < 3 mArms I2t for fusing t=10 ms 18000A2s
On-state voltage drop @ rated current 1.6Vrms
Critical dV/dt off-state 1000V/µs
Example: RJ1P48I50E Example: RJ1P48V50E
~
~
-
+
LOAD
4 - 20mA
2T1
1L1 5A3
3A1
4A26A4
~
~
LOAD
+
10VDC
2T1
1L1 5A3
3A1
4A26A4
+
0V24VDC/AC
-
0V
-
Specifications are subject to change without notice (30.09.2005) 3
RJ1P
Connection Examples
3A1 - 5A3: Control input current
3A1 - 5A3: Control input voltage, Vcc 4A2 - 6A4: Supply input voltage, Vss
LED INDICATION
The top Red LED indicates the load status. It goes ON when­ever the load is activated. The Green LED gives indication of the status of the control input.
Upon application of control current (for the RJ1P..I...) to terminals A1-A3, the Green LED will be dimly lit, with its intensity increasing with an increase in control current.
For the RJ1P..V..., the Green
LED will be ON (flickering) upon application of the supply voltage to terminals A2 - A4. Once a control voltage is applied to terminals A1 - A3, the Green LED will be fully ON, if greater than a threshold volt­age (approx. 0.5V). Note that the first time the device (volt­age control version) is to be activated, the mains voltage has to be present for the Green LED to indicate the control status.
Terminal Layout
Mode Selection
Operation
MODE
Transfer characteristics
Control Control Output
Current (mA) Voltage (VDC) Power (%)
400
8 2.5 25 12 5 50 16 7.5 75 20 10 99
Output power as a function of control input
MODE 1 Phase Angle Switching MODE 2 Distributed Control MODE 3 Burst Switching (1 sec. period) MODE 4 Burst Switching (3 sec. period) MODE 5 Burst Switching (10 sec. period)
MODE 1: The Phase Angle switching mode works in accordance with the phase angle control principle, i.e. the output switching point in the AC sine wave depends on the signal level applied at the input. The relay switches off everytime the output current crosses zero.
MODE 2: The Distributed mode provides a number of full cycles, evenly distributed over a fixed period of 1.28s @ 50Hz (1.07s @ 60Hz), depend­ing on the control input.
MODE 3, 4, 5: The Burst Switching mode generates a number of full cycles, depend­ing on the control input over fixed periods of 1s, 3s or 10s for MODES 3, 4 and 5 respec­tively.
Modes 2, 3, 4 and 5 use the zero switching principle, thus ensuring a reduced level of radiated and wire-conducted noise. The Distributed and Burst Switching modes are not recommended for light control due to light-flickering.
Note: For the RJ1P..V..., it is possible to have the ground terminals of the supply and control power supplies used commoned. In the case, this common ground is connected either to terminal A2 or terminal A3. This is only applicable when a 24 VDC supply voltage is used. There should be no external direct link from terminal A2 to Terminal A3.
4 Specifications are subject to change without notice (30.09.2005)
Dimensions
Functional Diagram
IC
A2 (-)
A4 (+)
A3 (-)
A1 (+)
Supply input
Control input
1 period = 64 cycles
1 period = 1s, 3s or 10s
RJ1P
Note: A2, A4 used only for voltage control version
MODE 1 Phase Angle
MODE 2 Distributed Full Cycle
MODE 3, 4, 5 Burst 1s, 3s, 10s
Derating Curve
Dissipation Curve
Load Current
(AACrms)
Surrounding temp. (Deg. C)
20 30 40 50 60
20
30
40
50
60
10
0
0102030405060
AACrms
W
10
20
30
40
50
0
50A
Note: Based on 100% output power
Loading...