Selection Guide - RGC..P (Integrated Overtemperature Protection)
o~íÉÇ=îçäí~ÖÉI= `зенкзд=оздн~ЦЙ `зееЙЕнбзе= o~нЙЗ=зйЙк~нбзе~д=ЕмккЙен=]=QMз`=EfOн=о~дмЙF
дзЕвбеЦ=оздн~ЦЙI= `зенкздL=mзпЙк mкзЗмЕн=пбЗнЬ
_
пбнЕЬбеЦ=гзЗЙ OP=^^`=EROR^²ëF OR=^^`=ENUMM^²ëF PM=^^`=ENUMM^²ëF UR^^`=ESSMM^²ëF
p
OOKRãã OOKRггI=дзп=ЗЙйнЬ OOKRãã TMãã=H=Ñ~å
30V, 800Vp 5-32VDC Screw/Screw RGC1A23D20GKEP - RGC1A23D30GKEP RGC1A23D90GGEP
2
ZC
P=^^`=EROR^²ëF OR=^^`=ENUMM^²ëF PM=^^`=ENUMM^²ëF
O
OKRãã OOKRггI=дзп=ЗЙйнЬ OOKRãã
O
600V, 1200Vp 5-32VDC Box/Screw RGC1A60D20GKEP RGC1A60D25GKEP RGC1A60D30GKEP
ZC
20-275VAC, 24-190VDC Box/Screw RGC1A60A20GKEP RGC1A60A25GKEP RGC1A60A30GKEP
QM=^^`=EPOMM^²ëF QP=^^`=ENUMMM^²ëF SM=^^`=EPOMM^²ëF SR^^`=ENUMMM^²ëF
PRãã PRãã TMãã TMãã
5-32VDC Box/Box RGC1A60D40GGEP RGC1A60D42GGEP RGC1A60D60GGEP RGC1A60D62GGEP
0-275VAC, 24-190VDC
2
5-32VDC Box/Box RGC1A60D90GGEP RGC1A60D92GGEP
20-275VAC, 24-190VDC B
ox/Box RGC1A60A40GGEP RGC1A60A42GGEP RGC1A60A60GGEP RGC1A60A62GGEP
B
UR^^`=ESSMM^²ëF UR^^`=ENUMMM^²ëF
Mãã=H=Ñ~å TMãã=H=Ñ~å
T
ox/Box RGC1A60A90GGEP RGC1A60A92GGEP
Output Voltage Specifications
od`KKOPKK od`KKSMKK
Operational Voltage Range 24-240 VAC, 42-600 VAC,
+10%, -15% on max +10% -15% on max
Blocking Voltage 800Vp 1200 Vp
Internal Varistor 275V 625V
General Specifications
Latching voltage
(across L1-T1) ≤20V
Operational frequency
range 45 to 65Hz
Power factor > 0.5 @ Vrated
Touch Protection IP20
Control input status continuously ON Green LED,
when control input is applied
Pollution degree 2
(non-conductive pollution with
possibilities of condensation)
Over-voltage category III
(fixed installations)
Isolation
Input to Output RGC... 4000 Vrms
RGC...D..P 2500 Vrms
RGC...A..P 4000 Vrms
Input and Output RGC... 4000 Vrms
to case RGC...D..P 4000 Vrms
RGC...A..P 4000 Vrms
Input to Fan/ Alarm Output
RGC...A..P 2500 Vrms
Specifications are subject to change without notice (14.06.2013) P
od`KKKb
Output Specifications (@ 25°C unless otherwise specified)
GC..15.. RGC..20.. RGC..25.. RGC..30..
Rated operational current
6
AC-51 rating @ Ta=25°C 20 AAC 25.5 AAC 30 AAC 30 AAC
AC-51 rating @ Ta=40°C 20 AAC 23 AAC 25 AAC 30 AAC
AC-53a rating @ Ta=40°C 5 AAC 5 AAC 5 AAC 8 AAC
Number of motor starts
(x:6, Tx:6s, F:50%) at 40˚C
5
Min. operational current 150 mAAC 150 mAAC 250 mAAC 250 mAAC
Rep. overload current -
(Motor Rating) PF = 0.4 - 0.5
UL508: T
=40°C, tON=1s, t
AMB
OFF
=9s,
50cycles 51 AAC 60 AAC 51 AAC 84 AAC
Maximum transient surge current (I
), t=10ms 325 Ap 325 Ap 600 Ap 600Ap
TSM
Maximum off-state leakage current
at rated voltage 3 mAAC 3 mAAC 3 mAAC 3 mAAC
I²t for fusing (t=10ms) Minimum 525 A²s 525 A²s 1800 A²s 1800 A²s
Crititcal dv/dt (@ Tj init = 40°C) 1000 V/us 1000 V/us 1000 V/us 1000 V/us
R
30 30 30 30
Rated operational current
6
AC-51 rating @ Ta=25°C 47 AAC 50 AAC 70 AAC 75 AAC 85 AAC 85 AAC
AC-51 rating @ Ta=40°C 40 AAC 43 AAC 60 AAC 65 AAC 85 AAC 85 AAC
AC-53a rating @ Ta=40°C 13 AAC 16 AAC 14.8 AAC 20 AAC 18 AAC 20 AAC
RGC..40.. RGC..42.. RGC..60.. RGC..62.. RGC..90.. RGC..92..
Number of motor starts
(x:6, Tx:6s, F:50%) at 40˚C
5
30 30 30 30 30 30
Min. operational current 400 mAAC 500 mAAC 400 mAAC 500 mAAC 400 mAAC 500 mAAC
Rep. overload current -
(Motor Rating) PF = 0.4 - 0.5
UL508: T
=40°C, tON=1s, t
AMB
OFF
=9s,
50cycles 126 AAC 126 AAC 144 AAC 168 AAC 168 ACC 168 AAC
Maximum transient surge current (I
), t=10ms 800 Ap 1900 Ap 800 Ap 1900 Ap 1150 Ap 1900 Ap
TSM
Maximum off-state leakage current
at rated voltage 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC 3 mAAC
I²t for fusing (t=10ms) Minimum 3200 A²s 18000 A²s 3200 A²s 18000 A²s 6600 A²s 18000 A²s
Crititcal dv/dt (@ Tj init = 40°C) 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us 1000 V/us
5. Overload current profle definition: x: multiple of AC53a rating, Tx: duration of current surge, F: duty cycle
6. See derating curves
Overtemperature Alarm Specifications for RGC...P
od`KKaKKm od`KK^KKm
Output type PNP open collector Potential Free
Normal state Closed Closed
Maximum current rating 50 mADC 50 mADC
Rated voltage (EN61131-2: 2003)
Rated voltage, Us RGC...D9xGGEP 24VDC ± 10% N/A
Fan rating, Uf RGC...A9xGGEP N/A 24VDC ±10%, 50mA nominal
Alarm voltage drop Typical 2.8VDC 1.8VDC
Visual Indication Continous Red LED Continous Red LED
Reverse polarity protection 24VDC 24VDC
8,7
, Ua 24VDC -15%, +20% 24VDC -15%, +20%
Maximum 4VDC 3.5VDC
7: DC supply for alarm signal should be supplied from a Class 2 power source
8: Maximum voltage to be applied between 11+ and 12- (Ua) terminals should be 35VDC maximum with reference to A2-
Q Specifications are subject to change without notice (14.06.2013)