Solid State Relays
3-Phase with Integrated Heatsink
Types RGC2, RGC3
• 2-pole & 3-pole AC switching solid state contactors
• Product width up to 70mm
• Rated operational voltage: up to 600VAC
• Rated operational current: up to 75AAC
• Control voltages: 5-32VDC, 20-275VAC (24-190 VDC)
• Up to 15,000A²s for I²t
• Motor ratings up to 11kW @ 400VAC, 25HP @ 600VAC
• Integrated varistor protection on output
Optional monitoring for SSR and load malfunction
•
(RGC..M)
EMR alarm output and auxiliary output (RGC..M)
•
• Controlled fan operation for versions with integrated fan
• UL, cUL Listing
• 100kA Short Circuit Current Rating according to UL508
• DIN or panel mount
• RoHS compliant
1: RGC..M is suitable only for resistive loads
1
Product Description
This product is intended to
replace mechanical
contactors especially when
switching is frequent. The
smallest product width in the
RGC2, RGC3 range is 54mm
(3xDIN) and goes up to
70mm.
2-pole and 3-pole switching
options are available. Switch
ON occurs at the voltage
zero cross and switch OFF
occurs at the current zero
cross. Apart from resistive
and slightly inductive loads,
the RGC is certified for motor
Fan operation is controlled
for the versions which have
an integrated fan.
Detection of SSR overheat,
mains loss, SSR malfunction
and load loss is possible with
the RGC..M versions. An
EMR alarm output is
available for remote
signaling. An additional
feature with the RGC..M is
the electronic auxiliary
output. The RGC..M has
additional LEDs for load
status and alarm status
indication.
Ordering Key
RGC 3 A 60 D 65 G G E D F M
Solid state relay
Number of switched poles
Switching mode
Rated operational voltage
Control voltage
Rated operational current
Connection type for control
Connection type for power
Connection configuration
External supply
Integrated fan
Monitoring features
switching with associated
motor ratings. Varistors are
integrated for output
overvoltage protection. A
green LED gives indication of
Specifications are at a
surrounding temperature of
25°C unless otherwise
specified.
control voltage presence.
Ordering Key (refer to page 2 for available part nos.)
SSR with Rated Control
heatsink voltage voltage
RGC2A: 22: D: 20: 20AAC K: Screw K: Screw E: Contactor D: 24VDC F: Integrated fan with over
2-pole switching + 42-242VAC, 5 - 32VDC 25: 25AAC G: Box Clamp G: Box Clamp A: 90-250VAC temperature protection (OTP) &
1-pole direct, ZC
RGC3A: 60: A: 65: 65AAC M: Monitoring for Mains loss,
3-pole switching, 42-660VAC, 20-275VAC, 75: 75AAC Load loss, SSR short circuit,
ZC 1200Vp 24-190VDC open circuit and over-
2. Refer to Current Derating curves
3. ZC= Zero Cross Switching
4. Operating voltage for RGC..M starts from 90VAC
5. AC control range for RGC..A..A.. is limited to 20-275VAC only
4
, (Uc) (Us)
(Ue)
Blocking
voltage
3
800Vp 30: 30AAC EMR alarm output
5
Rated current/
pole @40°C
40: 40AAC
2
Connection
control
Connection
power
Connection
configuration supply
External Features
temperature with EMR alarm
output and auxiliary output
(suitable only for resistive loads)
1
Specifications are subject to change without notice (03.06.2013) 1
RGC2, RGC3
Selection Guide: RGC2
Rated output
voltage,
Ue
20VAC
2
C
Z
00VAC
6
ZC
Control
voltage,
Uc
-32VDC -- Screw/Screw RGC2A22D25KKE --
5
0-275VAC,
2
4-190VDC
2
-32VDC -- Screw/Screw RGC2A60D25KKE --
5
0-275VAC,
2
24-190VDC
20-275VAC OTP 90-250VAC Box/Box --
Features
External
supply,
Us
-
-
TP 24VDC Box/Box --
O
TP 90-250VAC Box/Box --RGC2A60D75GGEAF
O
-- Screw/Screw RGC2A60A25KKE --
-- Screw/Box - RGC2A60A40KGE -
- Screw/Screw RGC2A22A25KKE --
- Screw/Box - RGC2A60D40KGE -
Selection Guide: RGC2..M
Rated output
voltage,
Ue
600VAC,
C
Z
Control
voltage,
Uc
5-32VDC Monitoring 24VDC Box/Screw RGC2A60D25GKEDM --
20-275VAC
Features
External
supply,
Us
Monitoring 24VDC Box/Box
onitoring 90-250VAC
M
onitoring 90-250VAC Box/Box - RGC2A60D40GGEAM RGC2A60D75GGEAFM
M
Monitoring 90-250VAC Box/Screw RGC2A60A25GKEAM -
Monitoring 90-250VAC Box/Box
Connection
control /
power
Connection
control /
power
Box/Screw RGC2A60D25GKEAM --
Rated operational current @ 40°C (I²t value)
25 AAC /pole
(1,800A²s)
40 AAC /pole
(6,600A²s)
Rated operational current @ 40°C (I²t value)
25 AAC /pole
(1,800A²s)
-
-
40 AAC /pole
(6,600A²s)
GC2A60D40GGEDM RGC2A60D75GGEDFM
R
RGC2A60A40GGEAM RGC2A60A75GGEAFM
75 AAC /pole
(15,000A²s)
GC2A60D75GGEDF
R
RGC2A60A75GGEAF
75 AAC /pole
(15,000A²s)
-
Selection Guide: RGC3
Rated
output
voltage,
Ue
220VAC,
ZC
600VAC,
ZC
Control
voltage,
Uc
5-32VDC -- Screw/
20-275VAC
24-190VDC
5-32VDC
20-275VAC
24-190VDC
20-275VAC OTP 90-250VAC Box/Box
Features
External
supply,
Us
-- Screw/
--
--
OTP 24VDC Box/Box --
OTP 90-250VAC Box/Box
-- Screw/
--
Connection
control /
power
Screw
Screw
Screw/
Screw
Screw/Box
Screw
Screw/Box
Selection Guide: RGC3..M
Rated
output
voltage,
Ue
600VAC,
ZC
Control
Features
voltage,
Uc
5-32VDC Monitoring
20-275VAC Monitoring 90-250VAC Box/Screw
Monitoring 24VDC Box/Box --
Monitoring 90-250VAC
Monitoring 90-250VAC Box/Box --
Monitoring 90-250VAC Box/Box
External
supply,
Us
24VDC
Rated operational current @ 40°C (I²t value)
20 AAC /pole
(1,800A²s)
RGC3A22D20KKE
RGC3A22A20KKE
RGC3A60D20KKE
--
-
RGC3A60A20KKE
-
-
Connection
control /
power
Box/Screw
Box/Screw
25 AAC /pole
(1,800A²s)
----
----
RGC3A60D25KKE
---
RGC3A60A25KKE
-
--
30 AAC /pole
(6,600A²s)
Rated operational current @ 40°C (I²t value)
20 AAC /pole
(1,800A²s)
RGC3A60D20GKEDM
RGC3A60D20GKEAM
RGC3A60A20GKEAM
-
25 AAC /pole
(1,800A²s)
RGC3A60D25GKEDM
RGC3A60D25GKEAM
RGC3A60A25GKEAM
-
40 AAC /pole
(6,600A²s)
---
RGC3A60D30KGE
-
---
RGC3A60A30KGE
--
RGC3A60D40GGEDF
--
RGC3A60A40GGEAF
30 AAC /pole
(6,600A²s)
-
RGC3A60D30GGEDM RGC3A60D65GGEDFM
-RGC3A60D30GGEAM RGC3A60D65GGEAFM
-
RGC3A60A30GGEAM RGC3A60A65GGEAFM
65 AAC /pole
(15,000A²s)
RGC3A60D65GGEDF
RGC3A60D65GGEAF
RGC3A60A65GGEAF
65 AAC /pole
(15,000A²s)
-
-
2 Specifications are subject to change without notice (03.06.2013)