Specifications are subject to change without notice 1
Solid State Relay
Switching mode
Rated operational voltage
Rated operational current
4 to 20 mA control current
Non-rep. off-state peak voltage
• AC Solid State Relay
• Analog switching for resistive load
applications
• 4 to 20 mA control current
• Rated operational current: 10, 25 and 50 AACrms
• Rated operational voltage: Up to 600 VACrms
• LED-indication of loop current
Product Description
The analog switching relay
works in accordance with the
phase control principle, i.e.
the output switching point in
the AC sine wave depends on
the control current. 4 to 20
mA corresponds to no switch-
Ordering Key
Solid State Relays
ing and to full sine wave (near
linear). The relay switches off
every time the current crosses
zero, and switches ON in accordance with the applied
control current.
Type Selection
Switching mode Rated operational Rated operational Control current Non-rep. voltage
voltage current
E: Analog switching 24: 115 VACrms 10: 10 AACrms AA: 4 to 20 mA 06: 650 V
p
230 VACrms 25: 25 AACrms 12: 1200 V
p
48: 400 VACrms 50: 50 AACrms 16: 1600 V
p
480 VACrms
60: 600 VACrms
Selection Guide
Rated operational Non-rep. voltage Control current Rated operational current
voltage 10 AACrms 25 AACrms 50 AACrms
115 VACrms 650 V
p
4 to 20 mA RE 2410 AA 06 RE 2425 AA 06 RE 2450 AA 06
230 VACrms 650 V
p
4 to 20 mA RE 2410 AA 06 RE 2425 AA 06 RE 2450 AA 06
400 VACrms 1200 V
p
4 to 20 mA RE 4810 AA 12 RE 4825 AA 12 RE 4850 AA 12
480 VACrms 1200 V
p
4 to 20 mA RE 4810 AA 12 RE 4825 AA 12 RE 4850 AA 12
600 VACrms 1600 V
p
4 to 20 mA - - RE 6050 AA 16
General Specifications
RE 24.. AA 06 RE 48.. AA 12 RE 6050 AA 16
Operational voltage range 90 to 280 VACrms 265 to 530 VACrms 330 to 660 VACrms
Non-rep. peak voltage ≥ 600 V
p
≥ 1200 V
p
≥ 1600 V
p
Operational frequency range 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz
Power factor 0.5 0.5 0.5
Industrial, 1-Phase Analog Switching
Types RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
RE 48 50 AA 12