Carlo Gavazzi RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16 Catalog Page

Specifications are subject to change without notice 1
Solid State Relay Switching mode Rated operational voltage Rated operational current 4 to 20 mA control current Non-rep. off-state peak voltage
Analog switching for resistive load
applications
4 to 20 mA control current
Rated operational current: 10, 25 and 50 AACrms
Rated operational voltage: Up to 600 VACrms
LED-indication of loop current
Product Description
The analog switching relay works in accordance with the phase control principle, i.e. the output switching point in the AC sine wave depends on the control current. 4 to 20 mA corresponds to no switch-
Ordering Key
Solid State Relays
ing and to full sine wave (near linear). The relay switches off every time the current crosses zero, and switches ON in ac­cordance with the applied control current.
Type Selection
Switching mode Rated operational Rated operational Control current Non-rep. voltage
voltage current
E: Analog switching 24: 115 VACrms 10: 10 AACrms AA: 4 to 20 mA 06: 650 V
p
230 VACrms 25: 25 AACrms 12: 1200 V
p
48: 400 VACrms 50: 50 AACrms 16: 1600 V
p
480 VACrms
60: 600 VACrms
Selection Guide
Rated operational Non-rep. voltage Control current Rated operational current voltage 10 AACrms 25 AACrms 50 AACrms
115 VACrms 650 V
p
4 to 20 mA RE 2410 AA 06 RE 2425 AA 06 RE 2450 AA 06
230 VACrms 650 V
p
4 to 20 mA RE 2410 AA 06 RE 2425 AA 06 RE 2450 AA 06
400 VACrms 1200 V
p
4 to 20 mA RE 4810 AA 12 RE 4825 AA 12 RE 4850 AA 12
480 VACrms 1200 V
p
4 to 20 mA RE 4810 AA 12 RE 4825 AA 12 RE 4850 AA 12
600 VACrms 1600 V
p
4 to 20 mA - - RE 6050 AA 16
General Specifications
RE 24.. AA 06 RE 48.. AA 12 RE 6050 AA 16
Operational voltage range 90 to 280 VACrms 265 to 530 VACrms 330 to 660 VACrms
Non-rep. peak voltage 600 V
p
1200 V
p
1600 V
p
Operational frequency range 45 to 65 Hz 45 to 65 Hz 45 to 65 Hz Power factor 0.5 0.5 0.5
Industrial, 1-Phase Analog Switching Types RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
RE 48 50 AA 12
RE ..10 AA .. RE ..25 AA .. RE ..50 AA .. RE 6050 AA 16
Rated operational current AC 1 10 Arms 25 Arms 50 Arms 50 Arms Minimum operational current 500 mArms 500 mArms 500 mArms 500 mArms
Rep. overload current t=1 s 50 A
p
80 A
p
175 A
p
120 A
p
Off-state leakage current @ rated voltage, frequency 5 mArms 5 mArms 5 mArms 5 mArms
I
2
t for fusing t = 1-10 ms 130 A2s 310 A2s 1800 A2s 800 A
2
s
Critical dI/dt 100 A/µs 100 A/µs 100 A/µs 100 A/µs Critical dV/dt commutating 500 V/µs 500 V/µs 500 V/µs 500 V/µs Critical dV/dt off-state 500 V/µs 500 V/µs 500 V/µs 500 V/µs
2 Specifications are subject to change without notice
RE 24.. AA 06, RE 48.. AA 12, RE 6050 AA 16
Rated insulation voltage
Input to output 4000 VACrms
Rated insulation voltage
Output to case 4000 VACrms
Insulation resistance
Input to output 1010Ω
Insulation resistance
Output to case 1010Ω
Insulation capacitance
Input to output 8 pF
Insulation capacitance
Output to case 50 pF
Insulation Input Specifications
Control current range 4 to 20 mA
Voltage drop 8 VDC @ 20 mA Dynamic impedance 100 Allowable input current 50 mA
Reverse polarity protected Yes
RE ..10 AA .. RE ..25 AA .. RE ..50 AA ..
Operating temperature -20 to +70°C (-4 to +158ºF) -20 to +70°C (-4 to +158ºF) -20 to +70°C (-4 to +158ºF)
Storage temperature
-40 to +100°C (-40 to +212°F) -40 to +100°C (-40 to +212°F) -40 to +100°C (-40 to +212°F)
Junction temperature 125°C 125°C 125°C
R
th
junction-case 2 K/W 1.25 K/W 0.65 K/W
R
th
junction to ambient 12.5 K/W 12 K/W 12 K/W
Thermal Specifications
Functional Diagram
Control input
Load output/mains input
Mains input/load output
Control input
Line/load
Wiring Diagram
Caution:
Current to input must be limited to max. 50 mA.
Output Specifications
*) Min. power let-through 0.5%. Please refer to Applications.
IC
Loading...
+ 2 hidden pages