Specifications are subject to change without notice (01.10.2003) 1
Type Selection
Switching mode Rated operational Control voltage Rated operational Options
voltage current
A: Zero Switching 23: 230 VACrms A: 20-280 VAC/22-48 VDC 25 : 25 AACrms Z: Overvoltage
B: Instant-on switching 60: 600 VACrms D: 3 - 32 VDC* 50 : 50 AACrms protection (self-
75 : 75 AACrms switching)
* 4 to 32 VDC for 600 VAC types 100:100 AACrms
125:125 AACrms
Rated Non-rep. Control Rated operational current
operational voltage voltage 25 A 50 A 75 A 100 A 125 A
voltage
230 VACrms 650 V
p
3 - 32 VDC RAM1A23D25 RAM1A23D50 RAM1A23D75 RAM1A23D100 RAM1A23D125
20-280 VAC/22-48 VDC RAM1A23A25 RAM1A23A50 RAM1A23A75 RAM1A23A100 RAM1A23A125
600 VACrms 1200 V
p
4 - 32 VDC RAM1A60D25 RAM1A60D50 RAM1A60D75 RAM1A60D100 RAM1A60D125
20-280 VAC/22-48 VDC RAM1A60A25 RAM1A60A50 RAM1A60A75 RAM1A60A100 RAM1A60A125
Options
1 Overvoltage protection by self-switching: add suffix Z to include. Example: RAM1A60D25Z
2 690 VACrms rated operational voltage available on request for 75A, 100A and 125A types. Example: RAM1A69D75
• Zero switching (RAM1A) or instant-on
switching (RAM1B) AC Solid State Relay
• Direct copper bonding (DCB) technology
• LED indication
• Clip-on IP 20 protection cover
• Self-lifting terminals
• Housing free of moulding mass
• 2 input ranges: 3-32 VDC* and 20-280 VAC/22-48 VDC
• Operational ratings up to 125 AACrms and 600 VACrms
• Non-repetitive voltage: Up to 1200 V
p
• Opto-insulation: > 4000 VACrms
• Integrated overvoltage protection by self
switching (suffix “Z” option)
Product Description
The industrial, 1-phase relay
with antiparallel thyristor output is the most widely used
industrial SSR due to its multiple application possibilities.
The relay can be used for
resistive, inductive and
capacitive loads. The zero
switching relay switches ON
when the sinusoidal curve
crosses zero and switches
OFF when the current cross-
Solid State Relay
Number of poles
Switching mode
Rated operational voltage
Control voltage
Rated operational current
Options
Ordering Key
Solid State Relays
es zero. The instant-on relay
with DC control input can be
used for phase angle control.
The built-in snubber secures
transient protection. The LED
indicates the status of the
control input. The clip-on cover secures touch protection
(IP 20). Protected output terminals can handle cables up
to 16 mm
2
.
Selection Guide
Industrial, 1-Phase ZS (IO) w. LED
Types RAM1A, RAM1B
RAM 1 A 60 D 125 Z