Carlo Gavazzi DWB01, PWB01 Catalog Page

Monitoring Relays 3-Phase Load Guard Types DWB01, PWB01
DWB01 PWB01
• TRMS load guard relays for three phase alanced applications
b
• Measuring if the power factor is within set limits
• Measuring ranges: 5A, 10A, MI current transformers
• Power ON delay 1 to 30 s knob adjustable
• Separately adjustable upper/lower level on absolute
scale
• Programmable latching or inhibit at set level
• Automatic and manual start and stop of the system
Output: 8 A SPDT relay N.D. or N.E. selectable
• For mounting on DIN-rail in accordance with DIN/EN
50 022 (DWB01) or plug-in module (PWB01)
• 45 mm Euronorm housing (DWB01) or 36 mm plug-in
module (PWB01)
• LED indication for relay, alarm and power supply ON
Product Description
DWB01 and PWB01 are precise TRMS power factor monitoring relays for 3­phase balanced systems. They can be used for moni­toring the actual load of asynchronous motors and other symmetrical loads, where the power factor is almost proportional to the load. The relay measures the power factor (cos the ratio between the active and the apparent power of a motor.
ϕ), that is
Start/stop input allows to use a manual switch to start and stop the motor, without the need of an auxiliary device. The advantage of using the latch function is that the relay can be kept energized even after the end of the alarm condition. Inhibit func­tion can be used to avoid relay operation when not desired (maintenance, tran­sients). The LED's indicate the state of the alarm and the output relay.
Ordering key
Housing Function Type Item number Output Power Supply Range
DWB 01 C M48 10A
Type Selection
Mounting Output Supply: Supply: Supply: Supply:
DIN-rail Plug-in
SPDT SPDT
208 to 240 VAC 380 to 415 VAC 380 to 480 VAC 600 to 690 VAC
DWB 01 C M23 10A PWB 01 C M23 10A
PWB 01 C M48 10A
DWB 01 C M48 10A DWB01 C M69 10A
Input Specifications
Input
Voltage (Own power supply): 3 - phase DWB01: L1, L2, L3
1- phase DWB01CM23
ent:
r
Cur
Specifications are subject to change without notice (23.01.07) 1
PWB01: 5, 6, 7
DWB01CM48: 380 to 480 VAC ± 15%
DWB01CM69: 600 to 690 VAC ± 15%
PWB01CM23: 5, 6 (connect pins 6, 7)
M23: 208 to 240 VAC ± 15%
PWB01C 8: 380 to 415 VAC ± 15%
: L1, L2 (connect pins L2, L3)
208 to 240 VAC ± 15%
DWB01:
PWB01: 5A, 10A: 11, 10
5A, 10A: I1, I2 MI...: U1, U2
MI...:
9, 8
Measuring ranges Upper level Lower level
Power factor (cos ϕ) 0.1 to 0.99 0.1 to 0.99
AACrms Max. curr.
Direct input: 0.5 to 5A 30A
Standard CT (examples)
TADK2 50 A/5 A 5 to 50 A 60 A
AD2 150 A/5 A
T TAD6 400 A/5 A 40 to 400 A 480 A TAD12 1000 A/5 A 100 to 1000 A 1200 A
ACO200 6000 A/5 A 600 to 6000 A
T
MI CT ranges
MI 100 10 to 100 A 325 AAC MI 500
1 to 10A 50A
15 to 150 A 180 A
50 to 500 A
(30 s)
7200 A
1000 AAC
WB01, PWB01
D
Input Specifications (cont.)
Note:
The input voltage cannot raise over 300 VAC with respect to ground (PWB01 only)
Contact input
DWB01 Terminals Z1, U1 PWB01 Terminals 2, 9 Disabled > 10 k Enabled < 500 Pulse width > 500 ms
Hysteresis PF approx 0.1
General Specifications
Power ON delay 1 to 30 s ± 0.5 s Reaction time (input signal variation from
Alarm ON delay < 200 ms Alarm OFF delay < 200 ms
Accuracy (15 min warm-up time)
Temperature drift ± 1000 ppm/°C Delay ON alarm ± 10% on set value ± 50 ms Repeatability ± 0.5% on full-scale
Indication for
Power supply ON LED, green Alarm ON LED, red (flashing 2 Hz
Output relay ON LED, yellow
Environment
ee of protection IP 20
Degr Pollution degr Operating temperature
@ Max. voltage, 50 Hz -20 to 60°C, R.H. < 95% @ Max. voltage, 60 Hz -20 to 50°C, R.H. < 95%
Storage temperature -30 to 80°C, R.H. < 95%
Housing
Dimensions DWB01 45 x 80 x 99.5 mm
W
eight
ew ter
Scr
Tightening torque Max. 0.5 Nm
ovals
Appr CE-Marking Y EMC Electromagnetic Compatibility
Immunity According to EN 61000-6-2 Emissions
ee
PWB01 36 x 80 x 94 mm
minals
-20% to +20% or from +20% to -20% of set value)
during delay time)
3 (DWB01), 2 (PWB01)
Appr
ox. 250 g
acc. to IEC 60947 UL, CSA
es
ding to EN 61000-6-3
Accor
Output Specifications
Output SPDT relay Rated insulation voltage 250 VAC Contact ratings (AgSnO2)µ
Resistive loads AC 1 8 A @ 250 VAC
Small inductive loads AC 15 2.5 A @ 250 VAC
Mechanical life 30 x 106operations Electrical life 105operations
Operating frequency 7200 operations/h
ielectric strength
D
Dielectric voltage 2 kVAC (RMS) Rated impulse withstand volt. 4 kV (1.2/50 µs)
DC 12 5 A @ 24 VDC
DC 13 2.5 A @ 24 VDC
(at 8 A, 250 V, cos ϕ = 1)
ccording to EN 60947-1
A
Supply Specifications
Power supply Overvoltage cat. III
Rated operational voltage (IEC 60664, IEC 60038) Through terminals:
DWB01: L1, L2, L3 PWB01: 5, 6, 7
M23 177 to 276 VAC 45 to 65 Hz DWB01CM48 323 to 552 VAC45 to 65 Hz PWB01CM48 323 to 477 VAC 45 to 65 Hz
Dielectric voltage None Dielectric voltage supply to output 4 kV
Rated operational power
DWB01CM69 510 to 793 VAC 45 to 65 Hz
M23: 9 VA @ 230 VAC, 50 Hz M48: 13 VA @ 400 VAC, 50 Hz M69:
21 VA @ 600 VAC, 50 Hz Supplied by L1 and L2
Mode of Operation
DWB01 and PWB01 can be used for monitoring the actu­al load of asynchronous motors. The relay measures the absolute value for the power factor of the system PF= Active Power/Apparent Pow­er that is for balanced sys­tem with sinus waveforms the cosine of the angle between motor current and motor voltage (cos As cos
ϕ varies with the load of the motor, underload and overload can be indirectly detected by DWB01 and PWB01. The relation between the load and cos the type of motor
ϕ).
ϕ depends on
. As a
guideline to ensure correct working conditions for a motor, the upper level could be set above the cos marking on the motor, and the lower level under this val ue. It is anyway recommend­ed to make the adjustment in connection with a practical test. The relay has an adjustable power ON delay in order to avoid overload detection during motor star
Example 1
Latching mode, relay NE In this application DWB01 or PWB01 ar external current metering transformer, type MI..., (con­nected between U1 & U2) as
e connected to an
ϕ
-
t.
2 Specifications are subject to change without notice (23.01.07)