Carlo Gavazzi PD32CNB12 Data sheet

Page 1
Specifications are subject to change without notice (15.01.03) 1
Product Description
The PD32CNB12 sensor family comes in a compact 12 x 32 x 20 mm reinforced PMMA/ABS-housing. The sensors are useful in applications where high­accuracy detection as well as small size is required.
The Teach-In function for adjustment of the sensitivity makes the sensors highly flexible. The output type is preset (NPN or PNP), and the output switching function is programmable (NO or NC).
• Miniature sensor range
• Range: 120 mm
• Sensitivity adjustment by Teach-In programming
• Modulated, red light 660 nm
• Supply voltage: 10 to 30 VDC
• Output: 100 mA, NPN or PNP preset
• Make and break switching function programmable
• LED for output indication, signal stability and power ON
• Protection: reverse polarity, short circuit and transients
• Cable and plug versions
• Compact housing
• Excellent EMC performance
Photoelectrics Diffuse-reflective, Background Suppression Type PD32CNB12
Type Selection
Housing Range Ordering no. Ordering no. W x H x D S
n
NPN & PNP cable NPN & PNP plug Make & break switching Make & break switching
12 x 32 x 20 mm 120 mm PD 32 CNB 12 NPT PD 32 CNB 12 NPM5T
PD 32 CNB 12 PPT PD 32 CNB 12 PPM5T
Specifications
Rated operating distance (Sn) Up to 120 mm,
reference target Kodak test card R 27, white, 90% reflectivity, 100 x 100 mm
Blind zone 25 mm
Sensitivity Adjustable by Teach-In
(push button or wire)
Temperature drift 1%/ºC
Hysteresis (H)
(differential travel) 7% (grey scale displace-
ment 90%/18%)
Rated operational volt. (U
B
) 10 to 30 VDC
(ripple included)
Ripple (U
rpp
) 10%
Output current
Continuous (I
e
) 100 mA
Short-time (I) 100 mA
(max. load capacity 100 nF)
No load supply current (I
o
) 25 mA @ 24 VDC
Minimum operational current (Im)
0.5 mA
OFF-state current (I
r
) 100 µA
Voltage drop (U
d
) 2.4 VDC @ 100 mA
Protection
Short-circuit, reverse polarity and transients
Light source GaAlAs, LED, 660 nm Light type Red, modulated Sensing angle ± 2º Ambient light 5,000 lux Light spot 5 x 5 mm @ 60 mm
Operating frequency 1000 Hz Response time
OFF-ON (t
ON
) 0.5 ms
ON-OFF (t
OFF
) 0.5 ms
Power ON delay (t
v
) 300 ms
Output function
NPN and PNP Preset NO/NC switching function Set up by button
External Teach
Same function as button 10 to 30 VDC Locked (disable teach button) 0 to 2.5 VDC Operating mode Not connected
Indication
Output ON LED, yellow Power ON
LED, green
Ordering Key
Type Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection type Teach-In
PD32CNB12PPM5T
Page 2
Operation Diagram
2 Specifications are subject to change without notice (28.08.02)
Dimensions
PD32CNB12
Specifications (cont.)
Environment
Installation category II (IEC 60664/60664A;
60947-1)
Pollution degree 3 (IEC 60664/60664A;
60947-1)
Degree of protection IP 67 (IEC 60529; 60947-1)
Ambient temperature
Operating
-20°to +60°C (-4°to +140°F)
Storage -20°to +80°C (-4°to +176°F)
Vibration 10 to 55 Hz, 0.5 mm/7.5 g
(IEC 60068-2-6)
Shock 30 g / 11 ms, 3 pos, 3 neg
per axis (IEC 60068-2-6, 60068-2-32)
Rated insulation voltage 500 VAC (rms) Housing material
Body ABS, black Front material PMMA, red
Connection
Cable PUR, black, 2 m
4 x 0.14 mm
2
, Ø = 3.6 mm
Plug M8, 4-pin
Weight With cable: 40 g
With plug: 10 g
CE-marking Yes Approval cUL
Plug version
Cable version
Wiring Diagrams
+
-
1 BN
4 BK
2 WH
3 BU
NPN
PNP
tv = Power ON delay
Power supply
Object/target present
Break (NC) Output ON
Make (NO) Output ON
Teach input is active when 2 WH wire is connected to V+ (1 BN).
+
-
1 BN
4 BK
2 WH
3 BU
V
V
Page 3
Specifications are subject to change without notice (28.08.02) 3
Delivery Contents
Photoelectric switch: PD 32 CNB 12 ...
Installation instruction
• Packaging: Cardboard box
Accessories
PD32CNB12
Installation Hints
Relief of cable strain Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch pow­er cables from any other power cables, e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided
6.5
ø6.5
R4
ø6.5
10
12
32
20
6.25
20
67
R2.25
50
21
9
ø4.5
4.5
16.5
35
ø4.5
R4
R4
2
R28
4.5
20°
90°
13°
Mounting bracket APD32-MB3
For further information refer to “Accessories”
Page 4
4 Specifications are subject to change without notice (28.08.02)
Adjustment
Sensitivity adjustment, with static object
1. Line up the sensor with the object. Yellow LED and green LED are ON.
2. Press the button for 3 s until both LED’s flash simultaneously (the first switching point is stored).
3. Place the object outside the detection area.
4. Press the button for 1 s. a) The green LED flashes and stays ON: the
second switching point is stored, and the sensor is ready to operate.
b) Both LED’s flash simultaneously: the sensor
cannot detect the object, no switching points are stored.
Sensitivity adjustment, with only one object
1. Line up the sensor with the object. Yellow LED and green LED are ON.
2. Press the button for 3 s until both LED’s flash simultaneously (the first switching point is stored).
3. Leave the object in the detection area, press the button for 1 s. The green LED flashes and stays on: the second switching point is stored, and the sensor is ready to operate.
Sensitivity adjustment, with a running process
1. Line up the sensor with the object. Green LED is ON. At this stage the status of the yellow LED can be ignored.
2. The running process must be the only “object” within the detection area. Press the button for 3 s until both LED’s flash simultaneously.
3. Press the button for at least the duration of one pro­cess cycle.
a) The green LED flashes and stays ON: both
switching points have been stored, and the sen­sor is ready to operate.
b) Both LED’s flash simultaneously: the sensor
cannot detect the object, no switching points are stored.
Programming of make and break switching function
1. Press the button for 13 s. Both LED’s flash alternately.
2. Release the button: the green LED flashes.
3. While the green LED flashes, the output is inverted each time the button is pressed. This is indicated by the yellow LED. When the button is not pressed for 10 s, the current output function is stored. The sensor is now ready for operation.
Default setting
1. No object in the detection area: Press the button for 3 s, until both LED’s flash simultaneously.
2. No object in the detection area: Press the button for 1 s. The sensor is set to maximum sensitivity.
NB! The Teach Input (2 WH) will work similarly to the push button, active High.
PD32CNB12
3 s
1 cycle
13 s
3 s
1 s
3 s
1 s
1
23
4
Loading...