Specifications are subject to change without notice (15.03.01) 1
Timers Star Delta Types DAC01, PAC01
• Time range (Star): 0.1 to 600 s
• Time range (Star to Delta): 50 to 130 ms
• Knob selection of star time range
• Automatic start
• Repeatability: 0.2%
• Output: 8 A SPDT relay with neutral centre position
• For mounting on DIN-rail in accordance with DIN/EN 50 022
• 22.5 mm Euronorm housing or 36 mm Plug-in module
housing
• LED indication for relay status and power supply ON
Product Description
Star-delta control relay with two adjustable time ranges: Star function (0.1 to 600 s) and star to delta function (50 to 130 ms). For mount-
ing on DIN-rail (DAC 01) on Plug-in (PAC01).
Type Selection
Mounting Output Housing Supply: 24 VDC and 24 to 240 VAC Supply: 380 to 415 VAC
For DIN-rail 1 x SPDT D - 22.5 mm DAC 01 C M24 DAC 01 C M40 Plug-in P - Housing PAC 01 C M24 PAC 01 C M40
Time Specifications Output Specifications
Time ranges (star)
Knob selectable 0.1 to 1 s
1 to 10 s 6 to 60 s 60 to 600s
Star to delta delay 50 to 130 ms
Neutral centre position between star and delta
position
Setting accuracy 5% Repeatability 0.2%
Time variation
Within rated power supply 0.05% Within ambient temperature 0.2%
Reset
Time and relay Power supply interruption
200 ms
Output SPDT relay with neutral
centre position
Rated insulation voltage 250 VAC (RMS) Contact Ratings (AgSnO2)µ
Resistive loads AC 1 8 A @ 250 VAC
DC 12 5 A @ 24 VDC
Small inductive loads AC 15 2.5 A @ 250 VAC
DC 13 2.5 A @ 24 VDC
Mechanical life 30 x 10
6
operations
Electrical life ≥ 10
5
operations
(at 8 A, 250 V, cos ϕ = 1)
Operating frequency < 7200 operations/h Dielectric strength
Dielectric voltage 2 kVAC (RMS) Rated impulse withstand voltage 4 kV (1.2/50µs)
Ordering key
DAC 01 C M24
Housing Function Type Item number Output Power Supply
DAC01
PAC01
2 Specifications are subject to change without notice (15.03.01)
DAC 01
Supply Specifications General Specifications
Power supply Overvoltage cat. III Rated operational voltage (IEC 60664, IEC 60038) through terminals: A1 and A2 (DAC01) 2, 10 (PAC01) 24 VDC 10%15%
M24 24 to 240 VAC +10% -15%
45 to 65 Hz
M40: 380 to 415 VAC ± 15%
45 to 65 Hz
Voltage interruption 40 ms
Rated operational power 1.5 W
Power ON delay 100 ms Power OFF delay 100 ms
Indication for
Power supply status LED, green Output status LED, yellow (flashing when
timing)
Environment (EN 60529)
Degree of protection IP 20 Pollution degree 3 (DAC01) ,2 (PAC01)
(IEC 60664) Operating temperature -20 to 60 °C, R.H. < 95% Storage temperature -30 to 80 °C, R.H. < 95%
Weight 100 g Screw terminals DAC01
Tightening torque Max 0.5 Nm according to
IEC 60947
CE Marking Ye s EMC Electromagnetic Compatibility
Immunity According to EN 50082-2 Emission According to EN 50082-1
Timer Specifications According to EN 68812-1
Mode of Operation
The output relay is normally in the neutral centre position. When the power supply is applied, the relay switches to star position (pin 16 or 4) and the star period starts.
At the end of the set time period, the relay returns to the neutral centre position and the set delay between star and delta position starts. At the end of the star to delta delay (adjustable from
50 to 130 ms), the relay switches in delta position (pin 18 or 3) and does not release until the power sup­ply is interrupted for at least 200 ms. If the power supply is inter-
rupted for more than 200 ms before the star time period has expired, the relay does not operate and the time cir­cuit is set to zero. The relay is ready for a new time peri­od.
Time Setting
Upper knob:
Setting of star time range
Centre knob:
Star time setting on relative scale: 1 to 10% with respect to the chosen range.
Lower knob:
Star to delta time setting (50 to 130 ms)
Wiring Diagrams
Operation Diagram
DAC01 PAC01