Carlo Gavazzi PA18CLD0.T Data sheet

Specifications are subject to change without notice (27.02.2006) 1
Housing Rated Ordering no. Ordering no. Ordering no. Or der ing no. diameter operating SCR/Cable SCR/Plug SCR/Cable SCR/Plug
dist. (S
n
) Make switching Make switching Break switching Break switching
M 18 100 mm fixed PA18CLD01TO PA18CLD01TOM6 PA18CLD01TC PA18CLD01TCM6 M 18 200 mm fixed PA18CLD02TO PA18CLD02TOM6 PA18CLD02TC PA18CLD02TCM6 M 18 400 mm fixed PA18CLD04TO PA18CLD04TOM6 PA18CLD04TC PA18CLD04TCM6 M 18 400 mm adjust. PA18CLD04TOSA PA18CLD04TOM6SA PA18CLD04TCSA PA18CLD04TCM6SA
Note: Plugs to be ordered separately
• Range: 400 mm adjustable 100, 200 or 400 mm fixed
• Modulated, infrared light
• Supply voltage: 20 to 250 VAC
• Output: 500 mA SCR
• Make or break switching function, LED indication
• High immunity to ambient light
• Cable and plug versions
Photoelectrics Diffuse-reflective Type PA18CLD0.T, AC, PBTP-housing
The PA18CLD.. is a family of inexpensive general purpose Diffuse-reflective sensors in industrial standard 18 mm cylindrical PBTP housing. They are useful for simple applications where a basic sensor provides adequate
sensing performance. The sensors are simple to use and no adjustment are ne ­cessary (except 400 mm dif­fuse adjustable type). The output is a 2-wire NO or NC thyristor (SCR) output.
Product Description
Type Selection
Specifications
Rated operating dist. (Sn)
Adjustable Up to 400 mm Fixed 100, 200 or 400 mm
Reference target: Kodak test card R27, white, 90% reflectivity
Size: Sn < 400 mm 100 x 100 mm
Sn ≥ 400 mm
200 x 200 mm
Sensitivity
Adjustable type only 270° turn potentiometer,
Temperature drift 0.4%/K Hysteresis (H)
(Differential travel) 3 to 20%,
Rated operational volt. (UB) 20 to 250 VAC,
45 to 65 Hz
Output current (AC12, AC140)
Continuous (I
e
) 500 mA
Short-time (I) 3 A, max. 20 ms
Min. operational current (Im) 10 mA OFF-state current (Ir) Max < 5 mA, typ. 2.6 mA Voltage drop (Ud) Max 10 V, typ. 7 VAC Protection Transients Transient voltage Max 1 kV/0,5 J Light source GaAlAs LED, 880 nm
Light type
Infrared, modulated synchronized
Sensing angle ± 25° at 1/2 range Ambient light Max 10'000 lux
Operating frequency (f) 20 Hz, light/dark ratio 1:2 Response time
OFF-ON (t
ON
) 20 ms
ON-OFF (t
OFF
) 30 ms
Power ON delay (tV) Typ. 100 ms Indication function
Dark (NC) or light (NO) switching
Output ON LED, yellow
Type Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection type Adjustable
Ordering Key
PA18CLD04TCM6SA
2 Specifications are subject to change without notice (27.02.2006)
PA18CLD04T
Dimensions
M12 x 1
Operation Di a gram
Object present, light received
Output ON: Make switch ing (NO)
Break switching (NC)
Power supply
Tv
Tv
Wiring Diagrams
2 BN
2 BN
3 BU
3 BU
Specifications (cont.)
Environment
Overvoltage category
III (IEC 60664/60664A; 60947-1)
Pollution degree
3 (IEC 60664/60664A; 60947-1)
Degree of protection IP 67 (IEC 60529; 60947-1)
Temperature
Operating -20° to +60°C (-4° to 140°F) Storage -30° to + 70°C (-22° to 158°F)
Vibration 10 to 150 Hz, 0.5 mm/-
7.5 g (IEC 60068-2-6)
Shock 2 x 1 m 100 x 0.5 m
(IEC 60068-2-32)
Dielectric voltage 1600 VAC
(IEC 60364-4-41)
Housing material
Body PBTP, grey thermoplastic
polyester
Front Luran
®
, black Cable end Polyester, black Nuts Reinforced nylon
Connection
Cable Grey, 2 m, 2 x 0.5 mm
2
,
oilproof PVC, Plug M12 x 1 Cables for plug (M6) CON.6A-... series
Weight
Cable version 105 g Plug version 22 g
Approvals UL, CSA CE-marking Ye s
Note: Sensitivity only 400 mm adjustable
Installation Hints
Relief of cable strain
Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch pow­er cables from any other power cables, e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the cable should be avoided