Carlo Gavazzi ICS, IP69K, M12 Data Sheet

ICS, IP69K, M12
Proximity Inductive Sensors - Ecolab certified Standard and Extended Range, Stainless Steel Housing Types ICS, IP69K, M12
• Sensing distance: 2 to 8 mm
• Flush or non-flush mountable
• Long body version
• Rated operational voltage (U
• Output: DC 200 mA, NPN or PNP
• Normally open or normally closed
• 4 x 90° LED indication for output ON, short-circuit and overload
• Protection: reverse polarity, short circuit, transients
• M12 plug version
• According to IEC 60947-5-2
• High-pressure washdown resistant
• Ecolab certified, FDA-certified plastic
• Laser engraved on the housing, permanently legible
• Extended temperature range: -40°C...+80°C
• CSA certified for Hazardous Locations
): 10 - 36 VDC
b
Product Description Ordering Key
A family of inductive proxim­ity switches in stainless steel (AISI 316L) ideal for food and beverage applications where sensors are exposed to high pressure and high temperature cleaning pro­cesses.
They are fully sealed and resistant to all common acid and alkaline cleaning agents and disinfectants (Ecolab certified). IP68 and IP69K-rated products. Out­put is open collector NPN or PNP transistors.
Type Housing style Housing material Housing size Housing length Detection principle Sensing distance Output type
ICS12LF04NOM1-FB
Output configuration Connection Washdown series
Type Selection
Connec- Body Rated Ordering no. Ordering no. Ordering no. Ordering no. tion style operating NPN, PNP, NPN, PNP, distance S
Standard range
Plug Long 2 mm Plug Long 4 mm
Extended range
Plug Long 4 mm Plug Long 8 mm
1)
For flush mounting in metal
Normally open Normally open Normally closed Normally closed
n
1)
ICS12LF02NOM1-FB ICS12LF02POM1-FB ICS12LF02NCM1-FB ICS12LF02PCM1-FB
2)
ICS12LN04NOM1-FB ICS12LN04POM1-FB ICS12LN04NCM1-FB ICS12LN04PCM1-FB
1)
ICS12LF04NOM1-FB ICS12LF04POM1-FB ICS12LF04NCM1-FB ICS12LF04PCM1-FB
2)
ICS12LN08NOM1-FB ICS12LN08POM1-FB ICS12LN08NCM1-FB ICS12LN08PCM1-FB
2)
For non-flush mounting in metal
Specifications
Rated operational voltage (Ub) Ripple ≤ 10% Output current (I
) ≤ 200 mA @ 50°C
e
(≤ 150 mA @ 50-80°C)
OFF-state current (I
) ≤ 10 μA
r
No load supply current (I Voltage drop (U
) Max. 2 VDC @ 200 mA
d
Protection Reverse polarity,
short-circuit, transients
Voltage transient 1 kV/0.5 J Power ON delay (t
) ≤ 20 ms
v
Operating frequency (f) ≤ 2000 Hz
Specifications are subject to change without notice (08.01.16) 1
10 to 36 VDC (ripple incl.)
) ≤ 15 mA
o
Indication for output ON
Activated LED, yellow (4x90°) NO version Target present NC version Target not present
Indication for short circuit/ overload LED blinking (f = 2 Hz)
Assured operating sensing distance (S
) 0 ≤ Sa ≤ 0.81 x S
a
n
Effective operating distance (S
Usable operating distance (Su)
) 0.9 x Sn ≤ Sr ≤ 1.1 x S
r
0.9 x Sr ≤ Su ≤ 1.1 x S
n
r
Repeat accuracy (R) ≤ 5% Differential travel (H)
(Hysteresis) 1 to 20% of sensing dist.
ICS, IP69K, M12
Specifications (cont.)
Ambient temperature Operating
-40° to +80°C (-40° to +176°F)
short exposure (15’) to 100°C during cleaning process Storage
-40° to +80°C (-40° to +176°F)
Shock and vibration IEC 60947-5-2/7.4 Housing material
Body Stainless steel (AISI 316L)
Front
Grey PPS - FDA-certified
Connection Plug M12 x 1
Degree of protection IP67, IP68 (1 m, 7 days),
IP69K
Weight (cable/nuts included) Max. 35 g Dimensions See diagrams below Tightening torque 25 Nm
Dimensions (mm)
Approvals cULus (UL508)
cCSAus As Process Control
Equipment for Hazardous Note: The terminal connector (version ...M1) was not evaluated. The suitability of the terminal connector should be determined in the end-use application.
Locations.
- Class I, Division 2, Groups A, B, C and D.
- T5, Enclosure Type 4. Ambient temperature Ta: -25° to +60°C
CCC is not required for products with a maximum operating voltage of ≤ 36 V
EMC protection According to IEC 60947-5-2 IEC 61000-4-2 (ESD) 8 KV air discharge, 4 KV contact discharge IEC 61000-4-3 3 V/m IEC 61000-4-4 2 kV IEC 61000-4-6 3 V IEC 61000-4-8 30 A/m
MTTF
770 years @ 50°C (122°F)
d
Flush version
38.7 6.2 9.6 10.3
64.8
LED (4 x 90°)
3
142
6.2
Non-flush version
Installation
Flush mountable proximity switches, when installed in damping material, must be according to Picture 1A.
Picture 1A Picture 1B
≥ 3 x S
n
d
Free zone or non-damping material
Non-flush mountable proximity switches, when installed in damping material, must be according to Picture 1B.
≥ 3 x S
64.8
32.5 6.2 9.6 10.3
n
≥ 3 x d
d
**
3
142
LED (4 x 90°)
Free zone or non-damping material
: nominal sensing distance
S
n
d : sensor diameter (12 mm)
: nominal sensing distance
S
n
d : sensor diameter (12 mm)
** ≥ 6 mm, Sn = 4 mm (1x) ≥ 12 mm, Sn = 8 mm (2x)
2 Specifications are subject to change without notice (08.01.16)
Loading...