Carlo Gavazzi FAA01, FAA08 Data Sheet

Specifications are subject to change without notice (15.09.04) 1
Product Description Ordering Key
Delay on Operate
Delay on operate timer with 4 functions and selectable time ranges from 0.05 sec­onds to 300 hours.
Housing 48 x 48 mm for front panel mounting and on 8-pin or 11-pin socket.
• Knob selection of time range
• Knob adjustable time setting
• Knob selection of operating mode (4 functions): A - delay on operate B
2
- symmetrical recycler ON first E - interval J - one shot
• Automatic start
• Repeatability: ±0.3% on full scale
• Output: 5 A DPDT relay
• 48 x 48 mm housing for front panel mounting
• 8 or 11 pin sockets
• LED indication for relay status and power supply ON
Type Selection
FAA 01 D M24
Housing Function Type Item number Output Power supply
Mounting Output Plug Supply: 100 to 240 VAC
Front or socket DPDT 11-pin FAA01DM24 Front or socket DPDT 8-pin FAA08DM24
Time Specifications
Time ranges
Selectable by front knob
Repeatability ±0.3% on full scale
(±0.3 % ±10 ms max in a range of 1.2 s)
Setting accuracy ±5% on full scale ±50 ms Voltage drift ±0.5% on full scale
(±0.5% ±10 ms max in a
range of 1.2 s)
Temperature drift ±2% on full scale (±2%
±10ms in a range of 1.2 s)
Reset
Power supply interruption >100 ms Pulse width >50 ms
Types FAA01, FAA08
Timers
Power Supply Overvoltage cat II
Rated operational voltage (IEC 60947-1)
throuhgt terminals: (FAA01DM24) 2, 10 100 to 240 VAC +10%-15%
50 / 60 Hz
(FAA08DM24) 2, 7 100 to 240 VAC +10%-15%
50 / 60 Hz
Power consumption
Rated operational power 10VA @ 240 VAC, (50 Hz)
Supply Specifications
Time unit sec min hrs 10h
Full scale
setting
1.2 0.05 to 1.2 0.5 to 12 3 0.125 to 3 1.25 to 3
12 0.5 to 12 5 to 120 30 1.25 to 30 12.5 to 300
Output DPDT relay Output insulation resistance > 100 M(at 500 VDC) Contact Ratings (AgCdO
12
) µ
Resistive loads AC 1 5 A @ 250 VAC / 30 VDC
Mechanical life 1 x 107operations Electrical life 1 x 10
5
operations
(5 A at 250 VAC, cos ϕ = 1,
1.8 x 103operations/h)
Operating frequency < 1800 operations/h
Output Specifications
2 Specifications are subject to change without notice (15.09.04)
FAA01, FAA08
Function and Time Setting
Range and operation mode selection
Operating mode display window Operating mode selector
(function A, B
2, E, J)
Scale range display windows
Time unit selector (sec, min, hrs, 10h)
Time setting knob (set time)
Power indicator (green) (Flashes when timer operates; on when timer stops operating)
Time range selector (1.2, 3, 12 and 30 at full scale)
Output indicator (red) (Lit when output is ON)
Time unit display window
Mode of Operation
Function A Delay on operate
The set delay period begins as soon as the power supply is connected. At the end of the set delay the relay oper­ates and doesn’t release until the power supply is interrupted for at least 100 ms.
Function B
2
Symmetrical recycler (ON first)
The relay operates and the time period start as soon as the power is applied. At the end of the first set time peri­od, the relay releases. At the end of the second time peri­od (equal to the first), the relay operates again. This sequence continues with equal ON- and OFF- time periods until the power sup­ply is interrupted for at least 100 ms.
Function E Interval
The relay operates and the time period begins as soon as the power is applied. The relay releases at the end of the time period or when the power supply is disconnect­ed for at least 100 ms.
Function J One shot
The time period begins as soon as the power supply is connected and at the end of this period the relay operates for 1s.
Indication for
Power supply On LED, green
(flashing when timing)
Output ON LED, red
Environment
Degree of protection IP 40 (front panel) Operating temperature -10 to +55 °C (14 to 131 °F) Ambient humidity 35 to 85% RH
Housing dimesions 48 x 48 mm Weight Approx. 95 g CE marking Ye s EMC
Electromagnetic Compatibillity Immunity According to EN 61000-6-1 Emission According to EN 61000-6-3
General Specifications
Upper right knob:
Setting of function
A - delay on operate B
2 - simmetrical recycler
E - interval J - one shot
Lower right knob:
Time unit selector
sec (seconds) min (minuts) hrs (hours) 10h (10 hours)
Lower left knob:
Time range selector
1.2, 3, 12 and 30
Centre knob:
Time setting on relative scale
Loading...