Specifications are subject to change without notice (08.02.06) 1
Photoelectrics
• Range: 3 m
• Modulated infrared light
• Supply voltage: 10 to 40 VDC
• Output: 200 mA NPN or PNP
• Make and break switching function, LED indication
• Protection: Reverse polarity, short circuit, transients
• High immunity to ambient light
• Cable and plug versions
Retro-reflective photoelectric
switch with extended range
up to 3 m. Easily adjustable
sensitivity with 270° potentiometer. LED output indica-
tion. Short M18 metal housing
for heavy duty applications. IP
67. Easy mounting. DC and
AC types, fully protected.
Specifications
Optical angle ± 2.2°
Light spot size 150 mm at 2 m
Ambient light Max. 10,000 lux
Operating frequency (f)
Max. 120 Hz, light/dark ratio 1:2
Response time
OFF-ON (t
ON
) ≤ 3.2 ms
ON-OFF (t
OFF
) ≤ 5 ms
Indication function Dark and light
(complementary switch)
Output ON LED, yellow
Environment
Overvoltage category
III (IEC 60664/60664A; 60947-1)
Pollution degree
3 (IEC 60664/60664A; 60947-1)
Degree of protection IP 67 (IEC 60529; 60947-1)
Temperature
Operating -20° to +60°C (-4° to 140°F)
Storage -30° to + 70°C (-22° to 158°F)
Vibration 10 to 150 Hz, 0.5 mm/7.5 g
(IEC 60068-2-6)
Shock 2 x 1 m & 100 x 0.5 m
(IEC 60068-2-32)
Dielectric voltage 600 VAC (IEC 60364-4-41)
Housing material
Body Nickel plated brass
Front Luran®, black
Cable end Polyester, black
Nuts Nickel plated brass
Retro-reflective
Type ER1830.PAS, DC, Metal-housing
Product Description
Rated operating dist. (Sn) Up to 3 m
Ref. reflector type ER4
∅ 84 mm
Sensitivity
Adjustable 270° single turn pot. meter
Temperature drift 0.4%/K
Hysteresis (H)
(Differential travel) 3 to 20%
Rated operational volt. (UB)
10 to 40 VDC (ripple included)
Ripple (U
rpp
) Max. 10%
Output current
Continuous (I
e
) Max. 200 mA
Short-time (I) 200 mA,
max. load capacity 100 nF
No load supply current (IO) Max. 20 mA @ 200 mA
Min. operational current (Im) 0.5 mA
OFF-state current (Ir) Max. 100 μA
Voltage drop (Ud) Max. 2.5 V
Protection Reverse polarity, short circuit
overload, transients
Transient voltage 1 kV/0.5 J
Power ON delay (tv) Typ. 100 ms
Light source GaAlAs LED, 880 nm
Light type Infrared, modulated
Ordering Key
Type
Housing diameter
Range
Output type
Housing material
Connection type
ER 18 30 NPA S-1
Type Selection
Housing Rated Ordering no. Ordering no. Ordering no. Ordering no.
diameter operating NPN/cable NPN/plug PNP/cable PNP/plug
dist. (S
n
)
Make & break
swit.
Make & break
swit.
Make & break
swit.
Make & break swit.
M18 3 m ER 1830 NPAS ER 1830 NPAS-1 ER 1830 PPAS ER 1830 PPAS-1