Carlo Gavazzi CAM18DC Data sheet

Proximity Sensors Capacitive Teflon Housing Type CA, M18, DC
TRIPLESHIELD
• Featuring TRIPLESHIELD™ sensor protection
• Adjustable sensing distance 3-8 mm
• Rated operational voltage: 10-40 VDC
• Output: DC 200 mA, NPN or PNP
• Make and break switching function
• LED indication
• High noise immunity
• Flush types
• Cable versions
Product Description
Capacitive proximity switc h­es with sensing distance of 8 mm flush mounted in metal. 4-wire DC output with both ma ke (NO) and break (NC) switch ing.
White M18 Teflon housing with 2 m cable. Ideal for use in level applica tions in the chemical, semi-conductor and food & beverage indus­tries.
Ordering Key
Type Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration
CA 18 FLF 08 NA
Type Selection
Housing Rated Mounting Ordering no. Ordering no. diameter operating Transistor NPN Transistor PNP dist. (Sn)
M18 8 mm
1)
Object: Grounded steel plate
1)
Make & break switching Make & break switching
Flush (built-in)
CA18FLF08NA CA18FLF08PA
Specifications
Rated operating dist. (Sn) 3 to 8 mm factory set at 8 mm
Sensitivity Adj. 270° turn pot. meter Effective operation dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x S Usable operation dist. (Su) 0.8 x Sr ≤ Su ≤ 1.2 x S Repeat accuracy (R) ≤ 5% Hysteresis (H) Rated operational volt. (UB) 10 to 40 VDC
(ripple included)
Ripple ≤ 10% Rated operational current (Ie)
Continuous ≤ 200 mA
No-load supply current (Io) ≤ 10 mA Voltage drop (Ud) ≤ 2.5 VDC at max. load Protection Reverse polarity,
short-circuit, transients
Frequency of operating cycles (f) 30 Hz
4 to 20% of sensing distance
n
r
Indication for output ON LED, yellow Environment
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13)
Temperature
Operating temperature Storage temperature
Housing material Body, front, nuts Teflon
Connection Cable Grey, 2 m, 4 x 0.34 mm
Weight 110 g CE-marking Yes
-25° to +80°C ( -13° to +140°F)
-40° to +85°C (-40° to +149°F)
Oil proof PVC
2
Specifications are subject to change without notice (05.04.2017) 1
CA, M18, DC
Dimensions
Adjustment Guide
The environments in which capacitive sensors are install­ed can often be un garding temperature, humi dity , object distance and industrial (noise) interference. Because of this, Carlo Ga vazzi offers as standard features in all TRIP LESHIELD™ capacitive sensors a user-friendly sensi­tivity adjustment instead of having a fixed sensing range, extend ed sen sing range to
stable re-
accommodate mechanically demand ing are as, temperature stability to en sure minimum need for adjusting sensitivity if temperature varies and high immunity to elec tro magnetic interference (EMI).
Note:
Sensors are factory set (de­fault) to maximum rated sens­ing range.
Wiring Diagrams
1 BN
4 BK
2 WH
PNP
3 BU
NPN
1 BN
2 WH
4 BK
3 BU
Max.
Min.
Sensitivity
Installation Hints
Capacitive sensors have the unique ability to detect al­most all materials, either in li­quid or solid form. Capa ci tive sensors can detect metallic as well as non-metallic ob­jects, how ever, their tradition­al use is for non-metallic ma­terials such as:
Plastic Industry Resins, regrinds or
moulded products.
current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables
Chemical Industry Cleansers, fertilisers, liquid
soaps, corrosives and petrochemicals.
Wood Industry Saw dust, paper products,
door and window frames.
Ceramic & Glass
Industry
Raw material, clay or finish-
ed products, bottles.
Relief of cable strain
Incorrect
Correct
The cable should not be pulled
Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
A proximity switch should not serve as mechanical stop
Semi-conductor Industry
Food & Beverage
Industry
Packaging Industry Package inspection for level or contents, dry goods, fruits and vege­tables, dairy products.
Materials are detected due to their dielectric constant. The bigger the size of an ob-
Any repetitive flexing of the cable should be avoided
ject, the higher the density of material, the better or easi­er it is to detect the object. Nominal sensing di stan­ce for a capacitive sensor is referenced to a ground­ed me tal plate (ST37). For addi tional information re­garding di elec tric ratings of materials please re fer to Technical Information.
Delivery Contents
Capacitive switch: CA18FL...
• Screw driver
• 2 nuts
• Packaging: Cardboard box
• Installation & Adjustment Guide
2 Specifications are subject to change without notice (05.04.2017)
2 Specifications are subject to change without notice (03.01.03)