Carlo Gavazzi CA12CLC, CA18CLC, CA30CLC Data sheet

Proximity Sensors Capacitive Thermoplastic Polyester Housing Types CA, M18, M30, DC, Teach-in
• Featuring TRIPLESHIELDSensor Protection
• Sensing distance: 0.5 - 12 mm (M18) and
1.0 - 30 mm (M30) Teach-in of sensing distance via push-button or
• COM-input
• Automatic detection of NPN or PNP load
• Selectable make or break switching by means of Teach-in function
• Protection: Short-circuit, transients and reverse polarity
• Humidity compensation
• Alarm output
• 5 years of warranty
LD
E
HI
S
LE
P
RI
T
Capacitive proximity switch­es with a sensing distance of either 8 mm flush mount­ed in metal or 12 mm non­flush mounted for the M18 version, and either 16 mm flush mounted in metal or 30 mm non-flush mounted for the M30 version. The
switching points can be altered by means of the Teach-in function. 3-wire DC output with selectable make (NO) or break (NC) switching and NPN Alarm. Grey polyester housing with 2 m PVC cable or M12 plug.
Ordering KeyProduct Description
Capacitive proximity switch Housing diameter (mm) Housing material Housing length Detection principle Rated operating dist. (mm) Output type Output configuration Connection type
CA18CLC12BPM1
Type Selection
Housing diameter Rated operating distance Ordering no. Ordering no.
M18 12 mm CA18CLC12BP CA18CLC12BPM1 M 30 30 mm CA30CLC30BP CA30CLC30BPM1
(S
) Cable Plug
n
Specifications
Sensing range (Sd)
CA18CLC12 0.5 - 12 mm
CA30CLC30 1.0 - 30 mm
Sensitivity Adjustable (Teach-in) Effective operating dist. (Sr) 0.9 x Sn≤ Sr≤ 1.1 x S Usable operating dist. (Su) 0.8 x Sr≤ Su≤ 1.2 x S Repeat accuracy (R) 5% Hysteresis (H) Rated operational volt. (UB) 10 to 40 VDC (ripple incl.) Ripple 10% Rated operational current (Ie) 250 mA (continuous) No-load supply current (Io) 12 mA Voltage drop (Ud) 2.5 VDC @ max. load Protection Short-circuit, reverse
TRIPLESHIELD
protection-EMC
IEC 1000-4-2/EN 61000-4-2 30 kV
IEC 1000-4-3/EN 61000-4-3 > 15 V/m IEC 1000-4-4/EN 61000-4-4 3 kV IEC 1000-4-6/EN 61000-4-6 > 10 V
TM
factory set at 8 mm
factory set at 15 mm
n
r
Depending on Teach-in
polarity, transients
rms
Frequency of operating cycles (f) 15 Hz
Indication
For output ON LED, yellow For safe/unsafe LED, green
Environment
Degree of protection IP 68 Operating temperature Storage temperature
Housing material
Body Grey, thermoplastic polyester Cable end Polyester, softened Nuts Black, PA12 Grilamid
Connection
Cable Grey, 2 m, 4 x 0.25 mm
Plug (M1) M12 x 1 Cable for plug (M1) CON.1A-series
Weight
Cable version - M18 / M30 110 g/160 g Plug version - M18 / M 30 30 g/70 g
Approvals UL, CSA CE-marking Yes
-20° to +85°C ( -4° to +185°F)
-40° to +85°C (-40° to +176°F)
Oil proof, PVC
2
Specifications are subject to change without notice (25.01.2010) 1
CA, M18, M30, DC, Teach-in
89.289.2
5
050
2323
M18 x 1
L
ED
M12
89.5589.55
5050
2323
M
18 x 1 LED
9
9.2
50
23
M30 x 1.5
LED
9
0.45
50
23
M30 x 1.5
L
ED
M12 x 1
Dimensions
CA18
Cable
Adjustment Guide
The environments in which capacitive sensors are install­ed can often be un
stable re­garding temperature, humidity, object distance and industrial (noise) interference. Because of this, Carlo Gavazzi offers as standard features in all
Installation Hints
Capacitive sensors have the unique ability to detect al­most all materials, either in li­quid or solid form. Capacitive sensors can detect metallic as well as non-metallic ob­jects, however, their tradition­al use is for non-metallic materials such as:
Plastics Industry
Resins, regrinds or mould­ed products.
Plug
TRIPLESHIELD™ capacitive sensors a user-friendly sensi­tivity adjustment instead of having a fixed sensing range, extended sensing range to accommodate mechanically demanding areas, temperature stability to ensure minimum
Chemical Industry Cleansers, fertilisers, liquid soaps, corrosives and pe­trochemicals.
Wood Industry Saw dust, paper products, door and window
frames.
Ceramic & Glass
Industry
Raw material, clay or finished products, bottles.
CA30
Cable
need for adjusting sensitivity if temperature varies and high immunity to electromagnetic interference (EMI).
Packaging Industry Package inspection for level or contents, dry goods, fruits and vegetables, dairy products.
Materials are detected due to their dielectric constant. The bigger the size of an object, the higher the density of ma­terial, the better or easier it is to detect the object. Nominal sensing distance for a capaci-
Plug
Note:
Sensors are factory set (default) to nominal sensing range S
.
n
tive sensor is referenced to a grounded metal plate (ST37). For additional information regarding dielectric ratings of materials please refer to Technical Information.
current peaks, separate the prox. switch pow­er cables from any other power cables, e.g. motor, contactor or solenoid cables
Relief of cable strain
Not correct
Correct
The cable should not be pulled
Delivery Contents
Capacitive switch: CA..CLC..BP..
• Packaging: Cardboard box
• Installation & Adjustment Guide (MAN CAP ENG/GER)
Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided
Accessories
Plugs CON.1A.. series.
For further information please refer to “Accessories.
2 Specifications are subject to change without notice (25.01.2010)