Carlo Gavazzi CA30CAN Catalog Page

Proximity Sensors Capacitive Thermoplastic Polyester Housing
Types CA30CAN/CAF.....
4
• Protection: short-circuit, transients and reverse polarity
• Dust and humidity compensation
• Dust or Temperature alarm output
• Rated operational voltage: 10-40 VDC
• Output: DC 200 mA, NPN or PNP
• Standard Output: NO and NC
• LED indications for Power-supply, Output and Stability
• IP67, IP69K, Nema 1, 2, 4, 4X, 5, 6, 6P, 12
• Cable and M12 connector versions available
TH
Generation TRIPLESHIELD
4-30 mm Non-flush
TM
Product Description
The CA30CA.. capacitive proximity switches feature an improved 4TH Genera­tion TRIPLESHIELDTM tech­nology. Furthermore, these sensors feature increased immunity to electromagnetic inteference (EMI), especial­ly to frequency drives. Not only does 4TH Generation
TRIPLESHIELDTM feature
an increased EMI, but it also increases the immuni­ty to humidity and dust. The implementation of stability indication eases the setup procedure as both Stable ON and Stable OFF positions are
indicated by the Green and yellow LEDs. The sensing distance is increased by 20 – 25 % allowing room for additional stable detection. The Dust Alarm function gives an early warning that the sensing surroundings have to be cleaned. The Temperature alarm func­tion raises an alarm if the sensing surface goes beyond 60 degree celcius. The sensor housing is featur­ing IP69K as well as approval by ECOLAB for cleaning­and disinfection agents.
Ordering Key
Capacitive prox im ity switch Housing diameter (mm) Housing material Housing length Detection principle Rated operating dist. (mm) Output type Output configuration Connection type
CA30CAN25NAM1
Type Selection
Housing Sensor Output Output Connection Rated operating Ordering no. Ordering no. Ordering no. diameter type type function distance (Sn) Standard Dust alarm Temperature alarm
M 30 Flush NPN NO+NC Cable 2 - 16 mm CA30CAF16NA M 30 Flush NPN NO+NC M12 Plug 2 - 16 mm CA30CAF16NAM1 M 30 Flush PNP NO+NC Cable 2 - 16 mm CA30CAF16PA M 30 Flush PNP NO+NC M12 Plug 2 - 16 mm CA30CAF16PAM1 M 30 Flush PNP NO Cable 2 - 16 mm CA30CAF16PODU CA30CAF16POTA M 30 Flush PNP NC Cable 2 - 16 mm CA30CAF16PCDU CA30CAF16PCTA M 30 Non-Flush NPN NO+NC Cable 4 - 25 mm CA30CAN25NA M 30 Non-Flush NPN NO+NC M12 Plug 4 - 25 mm CA30CAN25NAM1 M 30 Non-Flush PNP NO+NC Cable 4 - 25 mm CA30CAN25PA M 30 Non-Flush PNP NO+NC M12 Plug 4 - 25 mm CA30CAN25PAM1 M 30 Non-Flush PNP NO Cable 4 - 25 mm CA30CAN25PODU CA30CAN25POTA M 30 Non-Flush PNP NC Cable 4 - 25 mm CA30CAN25PCDU CA30CAN25PCTA
Specifications EN 60947-5-2
Rated operating distance (Sn) Non-flush mounted sensor 4 - 25 mm (factory setting 25 mm), (ref. target 75x75 mm ST37, 1 mm thick, grounded) Flush mounted sensor 2 - 16 mm (factory setting 16 mm - non-flush mounted) (ref. target 48x48 mm ST37, 1 mm thick, grounded)
Specifications are subject to change without notice (24.06.2014) 1
Sensitivity control Adjustable by potentiometer Electrical adjustment 11 turns Mechanical adjustment 16 turns Adjustable distance Flush types 2 to 20 mm Non-flush types 4 to 30 mm
Effective operating dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x S Usable operating dist. (Su) 0.85 x Sr ≤ Su ≤ 1.15 x Sr
n
CA30CAN/CAF.....
Specifications (cont.) EN 60947-5-2
Repeat accuracy (R) ≤ 5% Hysteresis (H)
3 - 20%
Rated operational volt. (UB) 10 to 40 VDC (ripple incl.) Ripple ≤ 10% Output function NPN or PNP Output switching function N.O. and N.C. Rated operational current (Ie) ≤ 200 mA (continuous) Capacitive load 100 nF No-load supply current (Io) ≤ 12 mA Voltage drop (Ud) ≤ 2.0 VDC @ 200 mA DC Minimum operational
current (Im) ≥ 0.5 mA OFF state current (Ir) ≤ 100 μA Protection Short-circuit, reverse
polarity, transients
Frequency of operating cycles (f) 50 Hz
Response time OFF-ON (ton) ≤ 10 ms Response time ON-OFF (t
) ≤ 10 ms
off
Power ON delay (tv) ≤ 200 ms Indication
For output ON LED, yellow
Power and signal stability LED, green
Environment Installation category III (IEC 60664, 60664A;
60947-1) Degree of pollution 3 (IEC 60664, 60664A; 60947-1) Degree of protection IP 67, IP 68/60 min., IP69K* (IEC 60529; 60943-1) NEMA type 1, 2, 4, 4X, 5, 6, 6P, 12 Operating temperature Max. temperature on sensing face 120°C (248°F) Storage temperature
-30 to +85°C ( -22 to +185°F)
-40 to +85°C (-40 to +185°F)
Rated insulation voltage 1 kVAC (rms) IEC protection class III
Tightening torque ≤ 7.5 Nm Connection
Cable PVC,
Ø5.2 x 2 m, 4 x 0.34 mm2 Oil proof, grey Plug (M1) M12 x 1, - 4 pin
Temperature alarm output 60ºC ± 5ºC Response time examples TA = 25°C 16 sec @ T 390 sec @ T
TRIPLESHIELD
TM
= 800°C
EXC
= 80°C
EXC
Exceeding the norms for capacitive sensors Electrostatic discharge
(EN61000-4-2) Contact discharge > 40 kV Air discharge > 40 kV
Electrical fast transients/burst (EN 61000-4-4) ±4kV
Surge (EN 61000-4-5) Power-supply > 2kV (with 500 Ω) Sensor output > 2kV (with 500 Ω)
Wire conducted disturbances (EN 61000-4-6) > 20 Vrms
Power-frequency magnetic fields (EN 61000-4-8) Continous > 60 A/m, 75.9 µ tesla Short-time > 600 A/m, 759 µ tesla
Radiated RF electromagnetic fields (EN 61000-4-3) > 20 V/m
Shock (IEC 60068-2-27) 30 G / 11ms, 3 pos, 3 neg per axis
Rough handling shocks (IEC 60068-2-31) 2 times from 1m 100 times from 0,5m
Vibration (IEC 60068-2-6) 10 to 150 Hz, 1 mm / 15 G Housing material
Body PBT, grey, 30% glass reinforced Cable gland PA12, black Fingernuts PA12, black Trimmershaft Nylon
Weight Cable version 190 g Plug version 106 g
Approvals cULus (UL508) CE-marking Yes MTTFd 829 years @ 40°C (+104°F)
* The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications. The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning. The sensor is exposed to high pressure water from a spray nozzle that is fed with 80°C water at 8’000– 10’000 KPa (80–100bar) and a flow rate of 14–6L/min. The nozzle is held 100 –150 mm from the sensor at angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates with a speed of 5 times per minute. The sensor must not suffer any damaging effects from the high pressure water in appear ance and function.
-
90°
60°
30°
2 Specifications are subject to change without notice (24.06.2014)
Loading...
+ 3 hidden pages