Carlo Gavazzi CA18CL Data sheet

Specifications are subject to change without notice (20.08.01) 1
Rated operating dist. (Sn)
CA18CLF08 3 to 8 mm
factory set at 8 mm
CA18CLN12 3 to 12 mm
Sensitivity Adj. 270° turn pot. meter Effective operation dist. (Sr)0.9 x S
n
Sr≤ 1.1 x S
n
Usable operation dist. (Su)0.8 x S
r
Sn≤ 1.2 x S
r
Repeat accuracy (R) 5%
Hysteresis (H)
4 to 20% of sensing distance
Rated operational volt. (UB)
10 to 40 VDC (ripple included)
Ripple 10%
Rated operational current (I
e
)
Continuous 200 mA
No-load supply current (I
o
) 10 mA
Voltage drop (U
d
) 2.5 VDC at max. load
Protection Reverse polarity,
short-circuit, transients
Frequency of operating cycles (f) 30 Hz
Indication for output ON LED, yellow Environment
Degree of protection IP 67 (Nema 1, 3, 4, 6, 13)
Temperature
Operating temperature
-25° to +80°C ( -13° to +176°F)
Storage temperature
-40° to +85°C (-40° to +185°F)
Housing material
Body Grey, thermoplastic polyester Front Grey, polyester Cable end Polyester Nuts Black, reinforced nylon
Connection
Cable Grey, 2 m, 4 x 0.34 mm
2
Oil proof PVC Plug (M1) M12 x 1 Cable for plug (M1) CON.1A-series
Weight
Cable version 110 g Plug version 30 g
Approvals
UL, CSA
CE-marking Ye s
Type Selection
Product Description
Proximity Sensors Capacitive Thermoplastic Polyester Housing Type CA, M18, DC
• Featuring TRIPLESHIELDsensor protection
• Adjustable sensing distance 3-8 mm or 3-12 mm
• Rated operational voltage: 10-40 VDC
• Output: DC 200 mA, NPN or PNP
• Make and break switching function
• LED indication
•High noise immunity
• Flush and non-flush types
• Plug and cable versions
Capacitive proximity switches with either sensing distance 8 mm flush mounted in metal or sensing distance 12 mm non­flush mounted. 4-wire DC out­put with both make (NO) and
break (NC) switching. Grey M18 polyester housing with 2 m PVC cable or M12 plug. Ideal for use in level and plastic machinery applica­tions.
Housing Rated Mounting Ordering no. Ordering no. Ordering no. Ordering no. diameter operating Transistor NPN/cable Transistor NPN/plug Transistor PNP/cable Transistor PNP/plug
dist. (S
n
)
1)
Make & break Make & break Make & break Make & break switching switching switching switching
M18 8 mm
Flush (built-in)
CA18CLF08NA CA18CLF08NAM1 CA18CLF08PA CA18CLF08PAM1
M18 12 mm Non-flush CA18CLN12NA CA18CLN12NAM1 CA18CLN12PA CA18CLN12PAM1
1)
Object: Grounded steel plate
Specifications
TRIPLESHIELD
Capacitive proximity switch Housing style Housing size Housing material Housing length Detection principle Sensing distance Output type Output configuration Connection type
Ordering Key
CA18CLN12NAM1
2 Specifications are subject to change without notice (20.08.01)
Wiring Diagrams
EC, M18, DC
NPN
PNP
3 BU
2 WH
4 BK
1 BN
1 BN
2 WH
4 BK
3 BU
Max.
Min.
Sensitivity
The environments in which capacitive sensors are install­ed can often be un
stable re­garding temperature, humidity, object distance and industrial (noise) interference. Because of this, Carlo Gavazzi offers as standard features in all TRIP- LESHIELD™ capacitive sen­sors a user-friendly sensitivity adjustment instead of having a fixed sensing range, extend­ed sensing range to accom-
modate mechanically demand­ing areas, temperature stability to ensure minimum need for adjusting sensitivity if tempe­rature varies and high immuni­ty to electromagnetic interfe­rence (EMI).
Note:
Sensors are factory set (de­fault) to maximum rated sens­ing range.
Adjustment Guide
Installation Hints
Capacitive sensors have the unique ability to detect almost all materials, either in liquid or solid form. Capacitive sen­sors can detect metallic as well as non-metallic objects, however, their traditional use is for non-metallic materials such as:
Plastic Industry
Resins, regrinds or moulded products.
Chemical Industry Cleansers, fertilisers, liquid soaps, corrosives and pe­trochemicals.
Wood Industry Saw dust, paper products, door and window
frames.
Ceramic & Glass
Industry
Raw material, clay or finish­ed products, bottles.
Packaging Industry Package inspection for le­vel or contents, dry goods, fruits and vegetables, dairy products.
Materials are detected due to their dielectric constant. The bigger the size of an object, the higher the density of ma­terial, the better or easier it is to detect the object. Nominal sensing distance for a capaci-
tive sensor is referenced to a grounded metal plate (ST37). For additional information re­garding dielectric ratings of materials please refer to Technical Information.
Dimensions
1)
M12 x 1
1)
CA18CL...
1) Note: Only CA18CLN
Relief of cable strain
Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/ current peaks, separate the prox. switch pow­er cables from any other power cables, e.g. motor, contactor or solenoid cables
Incorrect
Correct
The cable should not be pulled
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the cable should be avoided