Proximity Sensors Capacitive
Thermoplastic Polyester Housing
™
Types CA, M12, DC, Teach-in
Capacitive proximity switches with a sensing distance
of either 4 mm flush mounted in metal or 8 mm nonflush mounted.
The switching points can
be altered by means of the
teach-in function. 3-wire DC
output with selectable make
(NO) or break (NC) switching
and NPN Alarm. Grey polyester housing with 2 m PVC
cable or M12 plug.
TRIPLESHIELD
• Featuring TRIPLESHIELD™ Sensor Protection
• Sensing distance: 0.5 - 8 mm
• Teach-in of sensing distance via push-button or wire
• Automatic detection of NPN or PNP load
• Selectable make or break switching by means of the
Teach-in function
• Protection: short-circuit, transients and reverse polarity
• Humidity compensation
• Alarm output
Ordering KeyProduct Description
Capacitive prox im ity switch
Housing diameter (mm)
Housing material
Housing length
Detection principle
Rated operating dist. (mm)
Output type
Output configuration
Connection type
Remote teach
CA12CLC08BPM1RT
Type Selection
Housing diameter Rated operating distance Ordering no. Ordering no.
(Sn) Cable Plug
M 12 8 mm CA12CLC08BPRT CA12CLC08BPM1RT
Specifications
Sensing range (Sd)
Non-flush mounted 0.5 - 8 mm,
ref. target 24x24 mm ST37,
1 mm thick, grounded
Flush mounted 0.5 - 4 mm,
ref. target 12x12 mm ST37,
1 mm thick, grounded
Sensitivity Adjustable (Teach-in)
Effective operating dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x S
Usable operating dist. (Su) 0.8 x Sr ≤ Su ≤ 1.2 x S
Repeat accuracy (R) ≤ 5%
Hysteresis (H)
Rated operational volt. (UB) 10 to 40 VDC (ripple incl.)
Ripple ≤ 10%
Output function NPN/PNP (auto detect)
Output switching function N.O. or N.C. (teachable)
Rated operational current (Ie) ≤ 200 mA (continuous)
No-load supply current (Io) ≤ 12 mA
Voltage drop (Ud) ≤ 2.5 VDC @ max. load
Minimum operational
current (Im) ≥ 1 mA
OFF state current (Ir) ≤ 0.3 mA
3 - 20%
n
r
Protection Short-circuit, reverse
polarity, transients
TRIPLESHIELDTM protection
Electrostatic discharge 30 kV
Burst 3 kV
Airborne HF > 15 V/m
Wire-conducted noise >10 V
> 3 Vrm (flush mounted)
Response time OFF-ON (ton) ≤ 35 ms
Response time ON-OFF (t
Power ON delay (tv) ≤ 200 ms
Frequency of operating
cycles (f) 15 Hz
Indication
For output ON LED, yellow
Power and signal stability LED, green
Environment
Installation category III (IEC 60664, 60664A;
60947-1)
Degree of pollution 3 (IEC 60664, 60664A;
60947-1)
Degree of protection IP 68 (24 hours) (IEC 60529;
60943-1)
) ≤ 31 ms
off
(non-flush mounted)
rms
Specifications are subject to change without notice (15.06.2017) 1

CA, M12, DC, Teach-in
Specifications (cont.)
NEMA type 1, 2, 12
Operating temperature
-20 to +85°C ( -4 to +185°F)
Max. temperature on sensing face 120°C (248°F)
Storage temperature
-40 to +85°C (-40 to +185°F)
Vibration 10 to 150 Hz, 1 mm/15 g
(IEC 60068-2)
Shock 30 g/77 ms, 3 pos, 3 neg
per axis (IEC 60068-2-32)
Rated insulation voltage 500 VAC (rms)
Housing material
Body Grey thermoplastic
polyester
Adjustment Guide
The environments in which
capacitive sensors are
in stall ed can often be
un
stable as regards to tem-
perature, humi dity ,
object distance and industrial (noise)
inter ference. Because of
this, Carlo Ga vazzi offers
as standard features in all
TRIP LESHIELD™ capacitive sensors a user-friendly
sensitivity adjustment instead
of a fixed sensing range.
Likewise, these sensors
provide an extend ed sensing range to accommodate
Wiring Diagram
Cable gland Polyester, softened
Nuts Black, PA12
Connection
Cable PVC, 2 m, 4 x 0.14 mm2
Oil proof, grey
Plug (M1) M12 x 1 - 4 pin
Cable for plug (M1) CONB14NF.. -series
Weight
Cable version 110 g
Plug version 30 g
Approvals cULus (UL508)
CE-marking Yes
mechanically de mand ing areas and tem perature stability
to en sure high immunity to
elec tro magnetic interference
Note:
Sensors are factory set
(default) to nominal sensing
range Sn.
(EMI) and a minimum need
for adjusting sensitivity if the
temperature varies.
Detection Diagram
Sensor
X
BK
WH
(4)
Target
BN+
(1)
I
< 20mA
I
LOAD
< 200mA
ALARM
(2)
Teach-in
BU-
(3)
Y
-0,080,000,080,160,240,310,39
8,0
6,0
4,0
2,0
0,0
[mm]
-2,0
-4,0
-6,0
-8,0
Sensor front
-2 0246810
Distance [Inches]
Distance [mm]
The PNP- or NPN-load will be automatically
detected.
The functions described in the Teach-in
guide can be set up by means of the teach-in
wire.
It is possible to teach-in several sensors at
the same time by connecting the WH-wires
in parallel to the common ”BU -” supply.
(#): Plug connections
Important: If the alarm output (WH-wire) is
unused, it has to be connected to +supply
0,3
0,2
0,2
0,1
0,0
[Inches]
-0,1
-0,2
-0,2
-0,3
2 Specifications are subject to change without notice (15.06.2017)