Capacitive proximity switches with a sensing distance
of either 4 mm flush mounted in metal or 8 mm nonflush mounted.
The switching points can
be altered by means of the
teach-in function. 3-wire DC
output with selectable make
(NO) or break (NC) switching
and NPN Alarm. Grey polyester housing with 2 m PVC
cable or M12 plug.
TRIPLESHIELD
• Featuring TRIPLESHIELD™ Sensor Protection
• Sensing distance: 0.5 - 8 mm
• Teach-in of sensing distance via push-button or wire
• Automatic detection of NPN or PNP load
• Selectable make or break switching by means of the
Teach-in function
• Protection: short-circuit, transients and reverse polarity
• Humidity compensation
• Alarm output
Ordering KeyProduct Description
Capacitive prox im ity switch
Housing diameter (mm)
Housing material
Housing length
Detection principle
Rated operating dist. (mm)
Output type
Output configuration
Connection type
Remote teach
Sensing range (Sd)
Non-flush mounted 0.5 - 8 mm, ref. target 24x24 mm ST37,
1 mm thick, grounded
Flush mounted 0.5 - 4 mm, ref. target 12x12 mm ST37,
1 mm thick, grounded
Sensitivity Adjustable (Teach-in)
Effective operating dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x S
Usable operating dist. (Su) 0.8 x Sr ≤ Su ≤ 1.2 x S
Repeat accuracy (R) ≤ 5%
Hysteresis (H)
Rated operational volt. (UB) 10 to 40 VDC (ripple incl.)
Ripple ≤ 10%
Output function NPN/PNP (auto detect)
Output switching function N.O. or N.C. (teachable)
Rated operational current (Ie) ≤ 200 mA (continuous)
No-load supply current (Io) ≤ 12 mA
Voltage drop (Ud) ≤ 2.5 VDC @ max. load
Minimum operational
current (Im) ≥ 1 mA
OFF state current (Ir) ≤ 0.3 mA
Response time OFF-ON (ton) ≤ 35 ms
Response time ON-OFF (t
Power ON delay (tv) ≤ 200 ms
Frequency of operating
cycles (f) 15 Hz
Indication
For output ON LED, yellow
Power and signal stability LED, green
Environment Installation category III (IEC 60664, 60664A;
60947-1)
Degree of pollution 3 (IEC 60664, 60664A;
60947-1)
Degree of protection IP 68 (24 hours) (IEC 60529;
60943-1)
) ≤ 31 ms
off
(non-flush mounted)
rms
Specifications are subject to change without notice (15.06.2017) 1
CA, M12, DC, Teach-in
Specifications (cont.)
NEMA type 1, 2, 12
Operating temperature
-20 to +85°C ( -4 to +185°F)
Max. temperature on sensing face 120°C (248°F)
Storage temperature
-40 to +85°C (-40 to +185°F)
Vibration 10 to 150 Hz, 1 mm/15 g
(IEC 60068-2)
Shock30 g/77 ms, 3 pos, 3 neg
per axis (IEC 60068-2-32)
Rated insulation voltage 500 VAC (rms)
Housing material
Body Grey thermoplastic
polyester
Adjustment Guide
The environments in which
capacitive sensors are
in stall ed can often be
un
stable as regards to tem-
perature, humi dity ,
object distance and industrial (noise)
inter ference. Because of
this, Carlo Ga vazzi offers
as standard features in all
TRIP LESHIELD™ capacitive sensors a user-friendly
sensitivity adjustment instead
of a fixed sensing range.
Likewise, these sensors
provide an extend ed sensing range to accommodate
Wiring Diagram
Cable gland Polyester, softened
Nuts Black, PA12
Connection
Cable PVC, 2 m, 4 x 0.14 mm2
Oil proof, grey
Plug (M1) M12 x 1 - 4 pin
Cable for plug (M1) CONB14NF.. -series
Weight
Cable version 110 g
Plug version 30 g
Approvals cULus (UL508)
CE-marking Yes
mechanically de mand ing areas and tem perature stability
to en sure high immunity to
elec tro magnetic interference
Note:
Sensors are factory set
(default) to nominal sensing
range Sn.
(EMI) and a minimum need
for adjusting sensitivity if the
temperature varies.
Detection Diagram
Sensor
X
BK
WH
(4)
Target
BN+
(1)
I
< 20mA
I
LOAD
< 200mA
ALARM
(2)
Teach-in
BU-
(3)
Y
-0,080,000,080,160,240,310,39
8,0
6,0
4,0
2,0
0,0
[mm]
-2,0
-4,0
-6,0
-8,0
Sensor front
-20246810
Distance [Inches]
Distance [mm]
The PNP- or NPN-load will be automatically
detected.
The functions described in the Teach-in
guide can be set up by means of the teach-in
wire.
It is possible to teach-in several sensors at
the same time by connecting the WH-wires
in parallel to the common ”BU -” supply.
(#): Plug connections
Important: If the alarm output (WH-wire) is
unused, it has to be connected to +supply
0,3
0,2
0,2
0,1
0,0
[Inches]
-0,1
-0,2
-0,2
-0,3
2 Specifications are subject to change without notice (15.06.2017)
40
78
26
Ø10.7
M12 x 1
LED
CA, M12, DC, Teach-in
80
40
M12 x 1
LED
M12 x 1 x 8
Ø10.7
24
1
4
3
2
Dimensions
Cable
Installation Hints
Capacitive sensors have
a unique ability to detect
al most any material in
li quid or solid form. Capaci tive sensors are able to
detect me tallic as well as
non-metallic ob jects. However, their traditional use is
for non-metallic materials
such as:
• Plastics Industry
Resins, regrinds or mould-
ed products.
• Chemical Industry
Cleansers, fertilizers, liquid
soaps, corrosives and
pe t ro chemicals.
• Wood Industry
Saw dust, paper products,
door and window
frames.
• Ceramics & Glass Industry
Raw materials, clay or
Plug
Colour code
1 Brown
2 White
3 Blue
4 Black
finish ed products, bottles.
• Packaging Industry
Package inspection
for level or contents, dry goods,
fruits and vegetables, dairy
products.
ier it is to detect the object.
The nominal sensing di stance for a capacitive sensor
is refe r red to a grounded
me tal plate (ST37). For additional information regarding
di elec tric ratings of materials please re fer to Technical
Materials are detected due
Information.
to their dielectric constant.
The bigger the size of an
object, the higher the density
of ma terial, the better or eas-
current peaks, separate the prox. switch
power cables from any other power cables,
e.g. motor, contactor or solenoid cables
Accessories
• Connector type CONB14NF.. -series.
Relief of cable strain
Not correct
Correct
The cable should not be pulled
Specifications are subject to change without notice (15.06.2017) 3
Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
A proximity switch should not serve as
mechanical stop
Any repetitive flexing of the
cable should be avoided
Delivery Contents
• Capacitive switch: CA12CLC08BP..
• Installation & Adjustment Guide
• 2 x M12 nuts
• Packaging: Cardboard box
124
3 sec.Push once
3
13
3 sec.Push once
2
13
3 sec.One cycle
2
2
10 sec.Push once
1
CA, M12, DC, Teach-in
Teach functions
Normal operation, optimized switching point
1. Mount the sensor in the application without the target
present. Yellow LED is not important and green LED
is ON.
2. Press the button for 3 seconds until both LEDs
are flashing simultaneously.
(The background is stored)
3. Place the target in the detection zone.
4. Press the button once and the sensor is ready to
operate (green LED ON, yellow LED ON)
(The second switch point is stored).
If the target is too close to the background, the
sen
background and the LEDs will alternate 3 times.
For maximum sensing distance (default setting)
1. Mount the sensor in the application without the target
present. Yellow LED is not important and green LED is
ON.
2. Press the button for 3 seconds until both LEDs
are flashing simultaneously.
(The background information is stored)
3. Press the button a second time and the sensor is
ready to operate (green LED ON, yellow LED ON)
(The sensor is set up with the maximum sensing
distance that is not influenced by the background).
sor will perceive both background and object as
For dynamic set-up (running process)
1. Line up the sensor at the target. Green LED is ON,
status on the yellow LED is not important.
2. Press the button for 3 seconds until both LEDs are
flashing simultaneously.
3. Press and hold the button a second time for at least
one second (both LEDs are flashing simultaneously
and fast) and keep the button pressed for at least one
process cycle. Release the button and the sensor is
ready to operate (the switch point is stored into the
sensor and is optimized respecting both background
and target information).
A more precise setting is possible if several process
cycles are analysed.
For make or break set-up (N.O. or N.C.)
1. Press the button for 10 seconds, until the green LED
flashes.
2. While the green LED flashes, the output is inverted
each time the button is pressed. Yellow LED indicates
N.O. function selected.
If the button is not pressed within the next 16
seconds, the current output is stored.
Factory settings
Press the button for 16 sec.
4 Specifications are subject to change without notice (15.06.2017)