Carlo Gavazzi CA12CLC, CA18CLC, CA30CLC Data sheet

Proximity Sensors Capacitive Thermoplastic Polyester Housing
Types CA, M12, DC, Teach-in
Capacitive proximity switch­es with a sensing distance of either 4 mm flush mount­ed in metal or 8 mm non­flush mounted. The switching points can be altered by means of the
teach-in function. 3-wire DC output with selectable make (NO) or break (NC) switching and NPN Alarm. Grey poly­ester housing with 2 m PVC cable or M12 plug.
TRIPLESHIELD
• Featuring TRIPLESHIELD™ Sensor Protection
• Sensing distance: 0.5 - 8 mm
• Teach-in of sensing distance via push-button or wire
• Automatic detection of NPN or PNP load
• Selectable make or break switching by means of the Teach-in function
• Protection: short-circuit, transients and reverse polarity
• Humidity compensation
• Alarm output
Ordering KeyProduct Description
Capacitive prox im ity switch Housing diameter (mm) Housing material Housing length Detection principle Rated operating dist. (mm) Output type Output configuration Connection type Remote teach
CA12CLC08BPM1RT
Type Selection
Housing diameter Rated operating distance Ordering no. Ordering no. (Sn) Cable Plug
Specifications
Sensing range (Sd) Non-flush mounted 0.5 - 8 mm, ref. target 24x24 mm ST37, 1 mm thick, grounded Flush mounted 0.5 - 4 mm, ref. target 12x12 mm ST37, 1 mm thick, grounded
Sensitivity Adjustable (Teach-in) Effective operating dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x S Usable operating dist. (Su) 0.8 x Sr ≤ Su ≤ 1.2 x S Repeat accuracy (R) ≤ 5% Hysteresis (H) Rated operational volt. (UB) 10 to 40 VDC (ripple incl.) Ripple ≤ 10% Output function NPN/PNP (auto detect) Output switching function N.O. or N.C. (teachable) Rated operational current (Ie) ≤ 200 mA (continuous) No-load supply current (Io) ≤ 12 mA Voltage drop (Ud) ≤ 2.5 VDC @ max. load Minimum operational
current (Im) ≥ 1 mA OFF state current (Ir) ≤ 0.3 mA
3 - 20%
n
r
Protection Short-circuit, reverse polarity, transients
TRIPLESHIELDTM protection Electrostatic discharge 30 kV Burst 3 kV Airborne HF > 15 V/m Wire-conducted noise >10 V > 3 Vrm (flush mounted)
Response time OFF-ON (ton) ≤ 35 ms Response time ON-OFF (t
Power ON delay (tv) ≤ 200 ms Frequency of operating
cycles (f) 15 Hz Indication
For output ON LED, yellow
Power and signal stability LED, green
Environment Installation category III (IEC 60664, 60664A;
60947-1) Degree of pollution 3 (IEC 60664, 60664A; 60947-1) Degree of protection IP 68 (24 hours) (IEC 60529; 60943-1)
) ≤ 31 ms
off
(non-flush mounted)
rms
Specifications are subject to change without notice (15.06.2017) 1
CA, M12, DC, Teach-in
Specifications (cont.)
NEMA type 1, 2, 12 Operating temperature
-20 to +85°C ( -4 to +185°F) Max. temperature on sensing face 120°C (248°F) Storage temperature
-40 to +85°C (-40 to +185°F) Vibration 10 to 150 Hz, 1 mm/15 g
(IEC 60068-2) Shock 30 g/77 ms, 3 pos, 3 neg
per axis (IEC 60068-2-32)
Rated insulation voltage 500 VAC (rms) Housing material
Body Grey thermoplastic polyester
Adjustment Guide
The environments in which capacitive sensors are in stall ed can often be un
stable as regards to tem-
perature, humi dity ,
object dis­tance and industrial (noise) inter ference. Because of this, Carlo Ga vazzi offers
as standard features in all TRIP LESHIELD™ capaci­tive sensors a user-friendly sensitivity adjustment instead of a fixed sensing range. Likewise, these sensors provide an extend ed sen­sing range to accommodate
Wiring Diagram
Cable gland Polyester, softened Nuts Black, PA12
Connection Cable PVC, 2 m, 4 x 0.14 mm2
Oil proof, grey Plug (M1) M12 x 1 - 4 pin Cable for plug (M1) CONB14NF.. -series
Weight Cable version 110 g Plug version 30 g
Approvals cULus (UL508) CE-marking Yes
mechanically de mand ing are­as and tem perature stability to en sure high immunity to elec tro magnetic interference
Note:
Sensors are factory set (default) to nominal sensing
range Sn. (EMI) and a minimum need for adjusting sensitivity if the temperature varies.
Detection Diagram
Sensor
X
BK
WH
(4)
Target
BN+
(1)
I
< 20mA
I
LOAD
< 200mA
ALARM
(2)
Teach-in
BU-
(3)
Y
-0,080,000,080,160,240,310,39
8,0
6,0
4,0
2,0
0,0
[mm]
-2,0
-4,0
-6,0
-8,0
Sensor front
-2 0246810
Distance [Inches]
Distance [mm]
The PNP- or NPN-load will be automatically detected.
The functions described in the Teach-in guide can be set up by means of the teach-in wire.
It is possible to teach-in several sensors at the same time by connecting the WH-wires in parallel to the common ”BU -” supply.
(#): Plug connections
Important: If the alarm output (WH-wire) is unused, it has to be connected to +supply
0,3
0,2
0,2
0,1
0,0
[Inches]
-0,1
-0,2
-0,2
-0,3
2 Specifications are subject to change without notice (15.06.2017)
40
78
26
Ø10.7
M12 x 1
LED
CA, M12, DC, Teach-in
80
40
M12 x 1
LED
M12 x 1 x 8
Ø10.7
24
1
4
3
2
Dimensions
Cable
Installation Hints
Capacitive sensors have a unique ability to detect al most any material in li quid or solid form. Capa­ci tive sensors are able to detect me tallic as well as non-metallic ob jects. How­ever, their traditional use is for non-metallic materials such as:
Plastics Industry Resins, regrinds or mould-
ed products.
Chemical Industry Cleansers, fertilizers, liquid
soaps, corrosives and pe t ro chemicals.
Wood Industry Saw dust, paper products,
door and window
frames.
Ceramics & Glass Industry
Raw materials, clay or
Plug
Colour code
1 Brown 2 White 3 Blue 4 Black
finish ed products, bottles.
Packaging Industry Package inspection
for level or con­tents, dry goods, fruits and vegetables, dairy products.
ier it is to detect the object. The nominal sensing di stan­ce for a capacitive sensor is refe r red to a grounded me tal plate (ST37). For addi­tional information regarding di elec tric ratings of materi­als please re fer to Technical
Materials are detected due
Information. to their dielectric constant. The bigger the size of an object, the higher the density of ma terial, the better or eas-
current peaks, separate the prox. switch power cables from any other power cables, e.g. motor, contactor or solenoid cables
Accessories
Connector type CONB14NF.. -series.
Relief of cable strain
Not correct
Correct
The cable should not be pulled
Specifications are subject to change without notice (15.06.2017) 3
Protection of the sensing face Switch mounted on mobile carrierTo avoid interference from inductive voltage/
A proximity switch should not serve as mechanical stop
Any repetitive flexing of the cable should be avoided
Delivery Contents
Capacitive switch: CA12CLC08BP..
• Installation & Adjustment Guide
• 2 x M12 nuts
• Packaging: Cardboard box
12 4
3 sec. Push once
3
13
3 sec. Push once
2
13
3 sec. One cycle
2
2
10 sec. Push once
1
CA, M12, DC, Teach-in
Teach functions
Normal operation, optimized switching point
1. Mount the sensor in the application without the target present. Yellow LED is not important and green LED is ON.
2. Press the button for 3 seconds until both LEDs are flashing simultaneously. (The background is stored)
3. Place the target in the detection zone.
4. Press the button once and the sensor is ready to operate (green LED ON, yellow LED ON) (The second switch point is stored). If the target is too close to the background, the sen background and the LEDs will alternate 3 times.
For maximum sensing distance (default setting)
1. Mount the sensor in the application without the target present. Yellow LED is not important and green LED is ON.
2. Press the button for 3 seconds until both LEDs are flashing simultaneously. (The background information is stored)
3. Press the button a second time and the sensor is ready to operate (green LED ON, yellow LED ON) (The sensor is set up with the maximum sensing distance that is not influenced by the background).
sor will perceive both background and object as
For dynamic set-up (running process)
1. Line up the sensor at the target. Green LED is ON, status on the yellow LED is not important.
2. Press the button for 3 seconds until both LEDs are flashing simultaneously.
3. Press and hold the button a second time for at least one second (both LEDs are flashing simultaneously and fast) and keep the button pressed for at least one process cycle. Release the button and the sensor is ready to operate (the switch point is stored into the sensor and is optimized respecting both background and target information). A more precise setting is possible if several process cycles are analysed.
For make or break set-up (N.O. or N.C.)
1. Press the button for 10 seconds, until the green LED flashes.
2. While the green LED flashes, the output is inverted each time the button is pressed. Yellow LED indicates N.O. function selected. If the button is not pressed within the next 16 seconds, the current output is stored.
Factory settings
Press the button for 16 sec.
4 Specifications are subject to change without notice (15.06.2017)