Cardinal Detecto 6127 Series, Detecto 6337, Detecto 6129 Series, Detecto 6339 Operating Instructions Manual

(
DIGITAL PHYSICIAN
Waist-High Scale
Model 6127 Series, 6129 Series
Eye-Level Scale
Operating Instructions
CARDINAL SCALE MFG. CO. 8525-M310-O1 Rev E 06/15
www.detectoscale.com
PO BOX 151
417) 673-4631 FAX (417) 673-5001
PH
WEBB CITY, MO 64870
and
Printed in USA
Technical Support: Ph: 866-254-8261 techsupport@cardet.com
8525-M310-O1 Rev E 612X Series and 633X Series
1
2
8525-M310-O1 Rev E 612X Series and 633X Series
FCC COMPLIANCE STATEMENT
This equipment generates uses and can radiate radio frequency and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area may cause interference in which case the user will be responsible to take whatever measures necessary to correct the interference.
You may find the booklet “How to Identify and Resolve Radio TV Interference Problems” prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402. Request stock No. 001-000-00315-4.
PROPER DISPOSAL
When this device reaches the end of its useful life, it must be properly disposed of. It must not be disposed of as unsorted municipal waste. Within the European Union, this device should be returned to the distributor from where it was purchased for proper disposal. This is in accordance with EU Directive 2002/96/EC. Within North America, the device should be disposed of in accordance with the local laws regarding the disposal of waste electrical and electronic equipment.
It is everyone’s responsibility to help maintain the environment and to reduce the effects of hazardous substances contained in electrical and electronic equipment on human health. Please do your part by making certain that this device is properly disposed of. The symbol shown to the right indicates that this device must not be disposed of in unsorted municipal waste programs.
COPYRIGHT
All rights reserved. Reproduction or use, without expressed written permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein.
DISCLAIMER
While every precaution has been taken in the preparation of this manual, the Seller assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend to a great extent upon the individual accuracy, skill and caution. For this reason the Seller is not able to guarantee the result of any procedure contained herein. Nor can they assume responsibility for any damage to property or injury to persons occasioned from the procedures. Persons engaging the procedures do so entirely at their own risk.
Serial Number_______________________ Date of Purchase ____________________ Purchased Form_____________________
___________________________________ ___________________________________
RETAIN THIS INFORMATION FOR FUTURE USE
8525-M310-O1 Rev E 612X Series and 633X Series
PRECAUTIONS
Before using this instrument, read this manual and pay special attention to all "WARNING" symbols:
IMPORTANT ELECTRICAL
WARNING
3
I
This page intentionally left blank.
4
II
8525-M310-O1 Rev E 612X Series and 633X Series
INTRODUCTION
Thank you for your purchase of our Detecto Digital Physician Waist-High or Detecto Digital Physician Eye-Level scale. It has been manufactured with quality and reliability at our factory in Webb City, MO USA. Your scale has been tested before leaving our factory to insure accuracy and dependability for years to come.
This manual will guide you through assembly, installation, and operation of your scale. Please read it thoroughly before attempting to use your scale and keep it handy for future reference.
SPECIFICATIONS
Capacity: 550 lb x .2 lb
(250 kg x .1 kg), selectable
Platform Size: 10 5/8” x 14 1/2”
(270 mm x 368 mm)
Dimensions: 10 7/8” W x 20 7/8” D x 37 7/8” H
(276 mm x 530 mm x 962 mm) Shipping Weight: 34 lb (15.4 kg) 36 lb (16.3 kg) Scale Height: 37 1/2 ” (953 mm) 57 1/8” (1451 mm) Height Rod Measures: 6129, 6129KG, 6339 - 30” to 78” (76 cm to 200 cm) x inch/cm
6129KGM - 30” to 78” (76 cm to 200 cm) by 1/4”/1mm Display: Six digit, Seven segment, 0.7 inch (17.8 mm) high LCD Power Requirements: 6 “AA” size Alkaline, Ni-Cad or NiMH batteries (not included) OR an
optional 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA
listed AC power adapter (Cardinal part number 6800-1045). Keyboard: Membrane type with 5 keys and 4 directional arrows
Waist-High Eye-Level
550 lb x .2 lb (250 kg x .1 kg), selectable
10 5/8” x 14 1/2” (270 mm x 368 mm)
10 7/8” W x 20 7/8” D x 57 1/2” H (276 mm x 530 mm x 1461 mm)
8525-M310-O1 Rev E 612X Series and 633X Series
1
UNPACKING INSTRUCTIONS
Remove scale from carton by lifting up with equal force from column and platform base. Check for any damage incurred in shipping. If scale has been damaged, place a claim with
the carrier. Use the original carton and shipping material to return the scale.
Remove all plastic wrapping, foam fillers and cardboard material from the scale. Remove and unpack the power supply and cord, if the scale was ordered with this option. Carton contents:
1) Column
2) Indicator
3) Platform base
4) Screws and lock washers
5) Height measuring rod - optional
NOTE! If column bracket is bent, straighten before assembling.
ASSEMBLY INSTRUCTIONS
Refer to Figures No. 1, 2, 3, and 4, then follow the instructions for scale assembly.
1. Carefully remove load cell and draft rod assembly from column.
IMPORTANT! Handle load cell assembly with care! Do not drop, bend or twist.
2. Slip column over column bracket on platform base. Screw column to column brackets (two 1/4 truss head screws in front of column and four in the back). See Figure No. 1.
3. Referring to Figure No. 2, remove both #10-32 Truss Head Screws and lock washers securing the indicator bracket to the column.
4. Lower load cell and draft rod assembly into column. Draft Rod must pass through opening in column bracket. Referring to Figure No 1, make sure open end of lower draft rod hook is facing forward toward platform.
5. Next, referring to Figure No. 3, fasten top hook bolt of load cell assembly (C) to column. Make sure the load cell assembly does not touch the sides of column.
6. Slide grommet away from load cell assembly and slide into slot on column. NOTE! The slot should be on back (wide side) of column.
7. Pull excess load cell cable in column leaving enough slack in cable so as not to have any side pull on load cell.
8. Place digital indicator bracket on column and attach with 2 (#10-32) truss head screws and lock washers removed in step 3. See Figure No. 2.
9. Using a desk or table, lay down scale with column horizontal to floor. Raise draft rod keeping out of lever's way. Push lever. When lever is in position, hook draft rod around pivot. See Figure No. 4.
10. Attach indicator to indicator bracket on column, then connect load cell cable to back of indicator. Refer to the 750 Weight Indicator Owner’s Manual (8555-M483-O1) for additional information.
11. Scale is now ready for operation.
2
8525-M310-O1 Rev E 612X Series and 633X Series