C21
GAS VALVES
700-059
CARRIER 700-061
700SERIES
These 700 Series Gas Valve Uni-Kits®are designed for intermittent pilot,
direct spark and hot surface applications. They incorporate a manual valve,
pilot valve, and a main gas pressure regulator. Each Uni-Kit includes all the
necessary parts and instructions needed to convert to direct spark or hot
surface applications. These valves are designed for many residential and
commercial applications such as central heating units, wall heaters, boilers
and mobile home furnaces. They also have all the wiring connections,
manual selector and adjustments easily accessible.
Electrical 24 volt, 60 Hz
Ambient rating –40°F to 175°F / –40°C to 80°C
Capacity (maximum regulation)
1/2" x 3/4" straight through 300,000
3/4" x 3/4" straight through 350,000
1" x 1" 720,000
3/4" x 1" 530,000*
3/4" x 3/4" 450,000*
Pressure regulator setting see Ordering Data
Maximum inlet pressure 14" W.C. (1/2 PSI)
* Using reducer bushings included in 1" valves.
INLET OUTLET SIDE OUTLET PRESSURE
UNI-LINE FACTORY SIZE SIZE STRAIGHT 1/2" FPT REGULATOR
ORDER NO. MODEL (FPT) (FPT) THROUGH WITH PLUGS SETTING CAPACITY*
UNIVERSAL MODELS – INTERMITTENT PILOT, DIRECT SPARK AND HOT SURFACE
700-052• 7000 BDER-S7A† 1/2" 3/4" • 3.5" NAT. GAS 300,000
700-055• 7000 BDER-LP-S7A† 3/4" 3/4" • 11" L.P. GAS 485,000
700-056• 7000 BDER-S7A† 3/4" 3/4" • 3.5" NAT. GAS 350,000
700-057• 7000 DERHC 1" 1" • 4.0" NAT. GAS 720,000
700-058• 7000 DEHC-S7A† 1" 1" • NONE★ ††
700-059• 7000 DERHC-S7C† 1" 1" • 4.0" NAT. GAS 720,000
5-WIRE HOOKUP MODELS – INTERMITTENT PILOT
700-061 7000 BKER-S7C† 3/4" 3/4" • 3.5" NAT. GAS 300,000
700-062✓■ 7000 BKER-S7A† 3/4" 3/4" • 3.5" NAT. GAS 350,000
700-066✓■ 7000 BKER-S7A† 3/4" 3/4" • 3.5" NAT. GAS 350,000
UNIVERSAL 2-STAGE MODELS – INTERMITTENT PILOT, DIRECT SPARK AND HOT SURFACE
UNI-LINE FACTORY INLET OUTLET TYPE
ORDER NO. MODEL SIZE (FPT) SIZE (FPT) OF GAS LO-FIRE HI-FIRE CAPACITY*
700-051 7000 BDER2-3-LP-S7C† 3/4" 3/4" L.P. 2.8" W.C. 11.0" W.C. 480,000
700-053 7000 BDER2-4-S7A† 3/4" 3/4" NAT. 1.3" W.C. 3.5" W.C. 300,000
700-063 7000 DER2-HC-3-LP-S7C† 1" 1" L.P. 2.8" W.C. 11.0" W.C. 960,000
700-064 7000 DER2-HC-4-S7C† 1" 1" NAT. 1.3" W.C. 3.5" W.C. 720,000
CANADIAN MODELS
INLET OUTLET SIDE OUTLET PRESSURE
UNI-LINE FACTORY SIZE SIZE STRAIGHT 1/2" FPT REGULATOR
ORDER NO. MODEL (FPT) (FPT) THROUGH WITH PLUGS SETTING CAPACITY*
700-C051 7000 ADER-S7B 1/2" 1/2" • 3.9" W.C. NAT. GAS 100,000
700-C054 7000 BDERP 1/2" 1/2" • 2.0" W.C. NAT. GAS 225,000
* 1000 Btu/Cu. Ft. 0.64 sp. gr. natural gas or 2500 Btu/Cu. Ft. 1.53 sp. gr. L.P. gas @ 1" W.C. pd.
† Has slow opening feature for soft ignition. Can be field removed.
††720,000 Btu natural gas; 1,150,000 Btu L.P. gas.
★ Nonregulated. A separate pressure regulator may be required for the system.
• Includes parts to adapt to direct spark or hot surface applications.
✓ Obsolete - available to stock on hand.
■ Consider 712-006 Ignition Kit.
PRESSURE REGULATOR
SETTINGS
PRESSURE REGULATOR CONVERSION KITS ARE SHOWN ON PAGE
C25.
PILOT, DIRECT AND HOT SURFACE IGNITION
SPECIFICATIONS
ORDERING DATA