The TM1 can be used to send a tank level report over the cellular link at repeated time
intervals and on a schedule. The number of reports can be altered by command but is
typically set to once every 4 hours.
Contact your supplier, agent or FLEET data service provider for changes to reporting
schedules and times.
The data packet it sends is only several hundred bytes in length and includes pressure
reading, battery health, temperature and signal level information.
It utilizes a CAT M1 Modem that allows transmissions over the Cellular network,
permitting short burst data transfers to conserve battery life.
Installation and Activation
The TM1 must always be mounted upright, in the open, clear of any metallic shields or
obstructions and within the propagation footprint of a Verizon LTE cell tower.
Drill a mounting hole that is 1.75” ( 45 mm) Diameter at the top of the tank such that it is
at the highest point or above the maximum liquid level.
NOTE: The TM1 has slots at its mounting flange that will allow liquid to drain to the
outside of the tank if the liquid level is above the lowest point on the TM1 body. This is
to stop any liquid forcing its way past the gasket and into the TM1 body. If the filling port
is above this level, fit an extension tube or fitting to the tank so that it holds the TM1
above the refilling port level.
Lower the transducer into the tank and as it feeds through the hole feed it through the
tightening nut provided.
Allow the transducer to lay horizontally flat at the lowest part of the tank.
Tighten the mounting nut onto the TM1 mounting flange.
Once the TM1 is in place, remove the small magnetic keeper from the side of the TM1
body. This will initiate the transmission and registration with the FLEET server and
should bring up a reading on the device page or dashboard on FLEET.
The Magnet can be used at any time to disable the TM1 for transporting or trouble
shooting. To reboot the TM1 insert the magnetic keeper with the engagement slot facing
downwards. Hold it there for about 15 seconds and then remove it.
Save the magnet for future use.