GB
product, please contact your local city oce, your household waste disposal service or
3
GB
Warnings!
- The air outlet of the appliance must not be connected to a ue which is used for exhausting
other fumes from appliances, such as a central heating, boilers etc..
- Ensure the external exhausting of the fumes, comply with the regulations in force.
- Ventilate the room suitably according to the laws in force when the appliance is working to­gether with gas, oil or coal burning appliances, at the same time.
- The motor of the peripheral exhausting group is powered by the cookerhood placed in the
kitchen.
- Before connecting the cooker hood to the mains supply, make sure that the voltage indicated in the rating plate corresponds to the mains voltage in the home.
- Before carrying out any sort of maintenance or cleaning operation, make sure that the ap­pliance is disconnected from the electrical mains.
- Appropriate maintenance ensures good working and good performance in the long run.
Advice for good performance of the appliance:
- Use an exhausting pipe with the necessary minimum length.
- A few bends with a maximun 90° bending angle.
- Materials in accordance with the directives.
- Avoid any drastic change in the section (constant diameter: ø 0 mm. advised)
- Read the mounting and operating istructions of the exhausting cooker-hood carefully.
- The manufacturer cannot be held responsible for a decrease of the air ow or for an increase
of noise level caused by non-compliance with the instructions above.
Warning! The the ''0(;7 suction centrals can be connected to any other products from the same manufacturer if they are equipped with the External Motor version. In case they are connected to products from other suppliers, the SCET-1 central unit can command them.
The manufacturer cannot be held responsible for damages caused by LQFRUUHFW use. No
garantee or indemnity will be due.
4
DDMEXT4
Warning!
The remote tted exhausting group (external motor) is built in class I plate, therefore it needs
the earth connection.
The appliance was designed to exhaust odors and vapors in the best way. The appliance is to
be installed on the outside wall of the house and connected to the cooker-hood which is in the
kitchen (g. 10) or to the SCET control unit 1.
Installation:
the mounting of the appliance is to be made by qualied technicians. Using the appropriate drilling jig (g. 13) drill all the holes marked on it into the external wall, by paying attention not
to damage water pipes or power lines. The holes on the wall are to be drilled with a 8 mm. bit.
Insert, step by step, the following parts in the holes drilled:
- the corresponding plastic dowels supplied (g. 13a)
- the two telescopic pipes in the hole of 200 mm. (g. 12c)
- the plastic pipe of 40 mm. diameter (g. 12d)
Before leaning the appliance against the wall, please remove the stainless steel carter using the
8 perimetrical screws (g. 13b), then insert the supply cord in the plastic pipe. Fix the appliance without the stainless steel external body, which was previously removed from the motor block,
by matching the holes of the motor block with the holes on the wall. Tighten with the screws supplied.
Connection of the pipes:
the appliance is endowed with an air entrance to be connected with the telescopic pipes and an
air outlet. After xing the appliance on the external wall, connect the two telescopic pipes (g. 12c), which are placed inside the wall, with the cooker-hood through the exible pipes. The xing operations have to be carried out by using suitable metallic tools (pipes and tools
have to be supplied by the installers).
Electrical connection to the hood:
the unit is supplied with a pipe 7 meters long. After having let the cable pass through the plastic
pipe (g. 12e) placed in the wall (g. 12d), placed it closed to the unit and connect the 6 poles connector (Fig.12e) and the 2 poles connector (Fig. 12g).
In order to avoid water inltrations, please apply silicone on the product perimeter, close to
the wall.