Caple CR9200 Instruction Manual

Twin Oven
Dual Fuel Cooker
Model: CR 9200
GB
Instruction Manual
2
The CE marking confirms that the appliance conforms to the following EU directives:
- safety requirements of EEC Directive “Gas” 90/396;
- protection requirements of EEC Directive “EMC” 89/336;
- requirements of EEC Directive 93/68.
Thank you for buying your new CAPLE cooker. To ensure that you get the best results from your new CAPLE cooker, we strongly suggest that you read this instruc­tion manual thoroughly before use. This manual contains installation advice, cleaning tips and a cooking guide, as well as other important facts about your CAPLE cooker. If treated with care, your CAPLE appliance should give you years of trouble-free cooking.
For Spare Parts, Technical Advice
or Product Service call the
CAPLE HELPLINE on 0870 241 1142
(Answerphone outside office hours)
Important:
This appliance is designed and manufactured solely for the cooking of domestic (household) food and is not suitable for any non domestic application and therefore should not be used in a commercial environment.
The appliance guarantee will be void if the appliance is used within a non domestic environment i.e. a semi commercial, commercial or communal environment.
3
Safety Reminders
Instruction Book
This appliance should only be used for it’s intended purpose as described in these instructions. Ensure that you fully understand these instructions before operating this appli­ance.
Space Requirements
Ensure that the specified ventilation space around the appliance is not obstructed.
Food Splashes
Always wipe clean the oven after use. Food splashes can carry on cooking next time and may become a fire hazard.
Hot Surfaces
It is important to remember that the sur­faces of cooking appliances get hot dur­ing use and retain the heat for some time after switching off. It is therefore advisable to keep small children away from the appliance.
The Grill and Top oven element
are exposed, so take great care when placing food in the oven or removing it. Use the grill pan handles or gloves.
DO NOT line the oven, grids, trays etc.
with aluminium foil as this could adverse­ly affect the heating elements and it could also damage the interior surfaces.
DO NOT place flammable materials in
the oven or in the storage compartment.
Faults
Do not continue to use this appliance if it appears to be faulty.
After Use
After use, ensure that the hob knobs are in position (off), and close the main gas delivery valve or the gas cylinder valve. Switch the oven controls off. Always switch off at the isolating switch before cleaning the appliance, or attempting any maintenance task, or when not in use for long periods (when on holiday).
CAPLE Service
To ensure the continued safe and effi­cient operation of this appliance, we rec­ommend that any servicing or repairs are carried out only by an authorised CAPLE SERVICE ENGINEER.
4
Electrical Requirements
WARNING!
ELECTRICITY CAN BE EXTREMELY DANGEROUS.
THIS APPLIANCE MUST BE EARTHED.
For your safety please read the following information:
This appliance must be installed by a qualified technician according with the current local regulations and in compliance with the manufacturer instructions.
The appliance must be connected to the electrical network verifying above all that the voltage corresponds to the value indicated on the specifications plate and that the cables section of the electrical plant can bear the load which is also indicated on the plate.
The cooker must be connected directly to the mains placing an omnipolar switch with minimum opening between the contacts of 3 mm between the appliance and the mains.
The power supply cable must not touch the hot parts and must be positioned so that it does not exceed 75°C at any point.
Once the cooker has been installed, the switch or socket must always be accessible.
Before effecting any intervention on the electrical parts the appliance must be disconnected from the network.
5
This appliance must be connected to a double pole isolating switch (fig. 1.1) and to the terminal block in the cooker (figs.
1.2 & 1.3) using the following guide:
FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 20 AMP FUSE
ON
Fig. 1.1
1) The wire which is coloured brown must be connected to the terminal marked L (Live), or coloured Red.
2) The wire which is coloured blue must be connected to the terminal marked N (Neutral), or coloured Black.
3) The wire which is coloured green and yellow must be connected to the terminal marked E (Earth) or coloured Green.
IMPORTANT: These connections must be carried out by a qualified electrical engineer.
CONNECTING FEEDER CABLE
To connect the feeder cable to the cook­er it is necessary to:
– Remove the screw that hold shield “A”
behind the cooker (fig. 1.2).
– Insert the feeder cable of the suitable
section (as described in the next chap­ter) into the cable clamp “D”.
– Connect the phase and earth cables to
the terminal block “B” according to the diagram in figure 1.3.
– Pull the feeder cable and block it with
cable clamp “D”.
– Re-mount shield “A”.
Fig. 1.2
D
B
A
Fig. 1.3
FEEDER CABLE SECTION type H05RR-F
230 V 3 x 2,5 mm2 (**) (**) – Connection with wall box connection.
PE
1 - Electrical Installation - Wall box connection
230 V
L
1
(L2)
PEN
6
750 mm
500 mm
A U T O
500 mm
50 mm
2 - Location
FOR THE INSTALLER
This cookers has class “2/1” overheating protection so that it can be installed next to a cabinet.
If the cooker is installed adjacent to furniture which is higher than the gas hob cooktop, a gap of at least 50 mm must be left between the side of the cooker and the furniture. The furniture walls adjacent to the cooker must be made of material resistant to heat.
The veneered syntetical material and the glue used must be resistant to a temperature of 90°C in order to avoid ungluing or deformations.
The cooker may be located in a kitchen, a kitchen/diner or bed-sitting room but not in a room containing a bath or shower.
Curtains must not be fitted immediatly behind appliance or within 500 mm of the sides. It is essential that the cooker is positioned as stated below. If the cooker is located on a pedestal it is necessary to provide safety measures to pre-
vent falling out.
The cooker must be installed by a qualified technician and in compliance with local safety standards.
air vent
Fig. 2.1
7
Fig. 2.2
Backguard
Before installing the cooker, assemble the backguard “C” (fig. 2.2).
1. The backguard “C” can be found packed at the rear of the cooker.
2. Before assembling remove any protective film/adhesive tape.
3. Remove the two spacers “A” and the screw “B” from the rear of the cooktop.
4. Assemble the backguard as shown in figure 2.2 and fix it by screwing the central screw “B” and the spacers “A”.
Fig. 2.3
Fitting the adjustable feet
The adjustable feet must be fitted to the base of the cooker before use. Rest the rear of the cooker an a piece of the polystyrene packaging exposing the base for the fitting of the feet. Fit the 4 legs by screwing them tight into the support base as shown in picture 2.4.
Fig. 2.4
A
C
B
8
Fig. 2.5
Fig. 2.6
Fig. 2.7
Fig. 2.8
WARNING When raising cooker to upright posi­tion always ensure two people carry out this manoeuvre to prevent dam­age to the adjustable feet (fig. 2.5).
WARNING Be carefull: do not lift the cooker by the door handle when raising to the upright position (fig. 2.6).
WARNING
When moving cooker to its final position
DO
NOT DRAG (fig. 2.7).
Lift feet clear of floor (fig. 2.5).
Levellig the cooker
The cooker may be levelled by screwing the lower ends of the feet IN or OUT (fig. 2.8).
9
The room containing the cooker should have an air supply in accordance with BS.5540: Part 2: 1989. All rooms require an openable window or equivalent while some rooms require a per­manent vent in addition to the openable window. The cooker should not be installed in a bed-sitting room, of volume less than 21 m
3
. Where a DOMESTIC COOKER is installed in a room or internal space, that room or internal space shall be provided with a permanent opening which communicates directly with outside air and is sized in accordance with table below. In domestic premises the permanent opening shall be an air vent. If there are other fuel burning appliances in the same room, BS.5540: Part 2: 1989 should be consulted to determine the requisite air vent requirements. If the cooker is installed in a cellar or basement, it is advisable to provide an air vent of effective area 100 cm
2
, irrespective of the room volume.
()
If the room or internal space containing these appliances has a door which opens
directly to outside, no permanent opening is required.
MINIMUM PERMANENT OPENING FREE AREA FOR FLUELESS APPLIANCE
5 m3to 10
m
3
Openable
window or
equivalent also
required
Maximum
appliance
rated input
limit
Room volume
11 m3to
20 m
3
> 20 m
3
< 5 m
3
Type of appliance
Domestic oven, hot-
plate, grill or any com-
bination thereof.
None
50 ()
cm
2
Nil
cm
2
Nil
cm
2
100
cm
2
Yes
Provison for ventilation
10
3 - Gas connection
GAS INSTALLATION
IMPORTANT NOTE
This appliance is supplied for use on NATURAL GAS only and cannot be used on any other gas without modification.
This appliance is manufactured for conversion to LPG if required and is supplied with a conversion kit.
The cooker must be installed by a qualified person in accordance with the Gas Safety (Installation and Use) (Amendment) Regulation 1990 and the relevant building/l.E.E. Regulations.
The following British Standards should be used as reference when installing this appliance. BS6172 1990, BS5440 part 2 1989 and BS6891 1988.
Failure to install the appliance correctly could invalidate any manufacturers warranty and lead to prosecution under the above quoted regulation.
In the UK C.O.R.G.I registered installers are authorised to undertake the installation and service work in compliance with the above regulations.
GAS CONNECTION
The installation of the cooker to Natural Gas or LP Gas must be carried out by a qualified gas engineer. Installers shall take due account of the provisions of the relevant British Standards Code of Practice, the Gas Safety Regulations and the Building Standards (Scotland) (Consolidation) Regulations issued by the Scottish Development Department.
INSTALLATION TO NATURAL GAS
Installation to Natural Gas must conform to the Code of Practice, etc. The supply pressure for Natural Gas is 20 mbar.
INSTALLATION TO LP GAS
This appliance must only be connected to LPG after an LPG conversion kit has been fitted, (see pages from 12 to 14). When operating on Butane gas a supply pressure of 28-30 mbar is required. When using Propane gas a supply pressure of 37 mbar is required. The installation must conform to the relevant British Standards.
Warning: Only a qualified gas engineer, also with technical knowledge of electricity should install the cooker. He should observe the Regulations and Codes of Practice governing such installation of gas cookers.
Note: It is recommended that the gas connection to the cooker is installed with a flexible connecting tube made to BS
5386.
11
GAS CONNECTION
The gas supply must be connected to the gas inlet which is located at the left or the right hand rear of the appliance (fig. 3.1). The pipe does not cross the cooker. When screwing the connecting tube operate with two spanners (fig. 3.2). The unused end inlet pipe must be closed with the plug, interposing the gasket.
After connecting to the mains, check that the coupling are correctly sealed, using soapy solution, but never a flame.
Fig. 3.2
Plug
Fig. 3.1
12
Conversion to LPG
Conversion procedure
INJECTORS REPLACEMENT
Select the injectors to be replaced according to the “Table for the choice of the injectors” (page 14).
To replace the injectors proceed as follows:
- Remove pan supports and burners from the cooktop.
- Using a wrench, substitute the nozzle injectors “J” (fig. 3.3, 3.4) with those most suitable for the kind of gas for which it is to be used.
The burners are conceived in such a way so as not to require the regulation of the primary air.
J
J
Fig. 3.3 Fig. 3.4
Loading...
+ 28 hidden pages