2
The CE marking confirms that the appliance conforms to the following EU directives:
- safety requirements of EEC Directive “Gas” 90/396;
- safety requirements of EEC Directive “Low voltage” 73/23;
- protection requirements of EEC Directive “EMC” 89/336;
- requirements of EEC Directive 93/68.
Thank you for buying your new CAPLE cooker. To ensure that you get the best
results from your new CAPLE cooker, we strongly suggest that you read this instruction manual thoroughly before use. This manual contains installation advice, cleaning
tips and a cooking guide, as well as other important facts about your CAPLE cooker.
If treated with care, your CAPLE appliance should give you years of trouble-free
cooking.
For Spare Parts, Technical Advice
or Product Service call the
CAPLE HELPLINE on 0870 241 1142
(Answerphone outside office hours)
Important:
This appliance is designed and manufactured solely for the cooking of domestic
(household) food and is not suitable for any non domestic application and therefore
should not be used in a commercial environment.
The appliance guarantee will be void if the appliance is used within a non domestic
environment i.e. a semi commercial, commercial or communal environment.
3
Safety Reminders
Instruction Book
This appliance should only be used for
it’s intended purpose as described in
these instructions.
Ensure that you fully understand these
instructions before operating this appliance.
Space Requirements
Ensure that the specified ventilation
space around the appliance is not
obstructed.
Food Splashes
Always wipe clean the oven after use.
Food splashes can carry on cooking next
time and may become a fire hazard.
Hot Surfaces
It is important to remember that the surfaces of cooking appliances get hot during use and retain the heat for some time
after switching off.
It is therefore advisable to keep small
children away from the appliance.
The Grill and Top oven element
are exposed, so take great care when
placing food in the oven or removing it.
Use the grill pan handles or gloves.
DO NOT line the oven, grids, trays etc.
with aluminium foil as this could adversely affect the heating elements and it
could also damage the interior surfaces.
DO NOT place flammable materials in
the oven or in the storage compartment.
Faults
Do not continue to use this appliance if
it appears to be faulty.
After Use
After use, ensure that the hob knobs are
in position ● (off), and close the main
gas delivery valve or the gas cylinder
valve.
Switch the oven controls off.
Always switch off at the isolating switch
before cleaning the appliance, or
attempting any maintenance task, or
when not in use for long periods (when
on holiday).
CAPLE Service
To ensure the continued safe and efficient operation of this appliance, we recommend that any servicing or repairs are
carried out only by an authorised CAPLE
SERVICE ENGINEER.
4
Electrical Requirements
WARNING!
ELECTRICITY CAN BE EXTREMELY DANGEROUS.
THIS APPLIANCE MUST BE EARTHED.
For your safety please read the following information:
This appliance must be installed by a qualified technician according with the current
local regulations and in compliance with the manufacturer instructions.
The appliance must be connected to the electrical network verifying above all that the
voltage corresponds to the value indicated on the specifications plate and that the cables
section of the electrical plant can bear the load which is also indicated on the plate.
The cooker must be connected directly to the mains placing an omnipolar switch with
minimum opening between the contacts of 3 mm between the appliance and the mains.
The power supply cable must not touch the hot parts and must be positioned so that
it does not exceed 75°C at any point.
Once the cooker has been installed, the switch or socket must always be accessible.
Before effecting any intervention on the electrical parts the appliance must be
disconnected from the network.
5
This appliance must be connected to a
double pole isolating switch (fig. 1.1) and
to the terminal block in the cooker (figs.
1.2 & 1.3) using the following guide:
FUSE
DOUBLE POLE SWITCHED
FUSED SPUR OUTLET
USE A 19 AMP FUSE
ON
Fig. 1.1
1) The wire which is coloured brown
must be connected to the terminal
marked L (Live), or coloured Red.
2) The wire which is coloured blue
must be connected to the terminal
marked N (Neutral), or coloured
Black.
3) The wire which is coloured green
and yellow must be connected to
the terminal marked E (Earth)
or coloured Green.
IMPORTANT: These connections must
be carried out by a qualified electrical
engineer.
CONNECTING FEEDER CABLE
To connect the feeder cable to the cooker it is necessary to:
– Remove the screw that hold shield “A”
behind the cooker (fig. 1.2).
– Insert the feeder cable of the suitable
section (as described in the next chapter) into the cable clamp “D”.
– Connect the phase and earth cables to
the terminal block “B” according to the
diagram in figure 1.3.
– Pull the feeder cable and block it with
cable clamp “D”.
– Re-mount shield “A”.
Fig. 1.2
D
B
A
Fig. 1.3
FEEDER CABLE SECTION
type H05RR-F
230 V 3 x 1,5 mm
2
PE
1 - Electrical Installation - Wall box connection
230 V
L
1
(L2)
PEN
800 mm
500 mm
50 mm
500 mm
Fig. 2.1
2 - Location
FOR THE INSTALLER
This cookers has class “2/1” overheating protection so that it can be installed next
to a cabinet.
The furniture walls adjacent to the cooker must be made of material resistant to heat.
The veneered syntetical material and the glue used must be resistant to a temperature
of 120°C in order to avoid ungluing or deformations.
If the cooker is installed adjacent to furniture which is higher than the gas hob cooktop,
a gap of at least 50 mm must be left between the side of the cooker and the furniture.
The cooker may be located in a kitchen, a kitchen/diner or bed-sitting room but not in
a room containing a bath or shower.
Curtains must not be fitted immediatly behind appliance or within 500 mm of the sides.
It is essential that the cooker is positioned as stated below.
If the cooker is located on a pedestal it is necessary to provide safety measures to pre-
vent falling out.
The cooker must be installed by a qualified technician and in compliance with
local safety standards.
7
FITTING THE ADJUSTABLE FEET
The adjustable feet must be fitted to the
base of the cooker before use.
Rest the rear of the cooker an a piece
of the polystyrene packaging exposing
the base for the fitting of the feet.
Fig. 2.3
Fig. 2.2
ASSEMBLING THE BACKGUARD
Before installing the cooker, assemble the backguard “C” (fig. 2.2).
1. The backguard “C” can be found packed at the rear of the cooker.
2. Before assembling remove any protective film/adhesive tape.
3. Remove the two spacers “A” and the screw “B” from the rear of the cooktop.
4. Assemble the backguard as shown in figure 2.2 and fix it by screwing the central
screw “B” and the spacers “A”.
8
Fig. 2.4
Fig. 2.5
Fig. 2.6
Fig. 2.7
WARNING
When raising cooker to upright position always ensure two people carry
out this manoeuvre to prevent damage to the adjustable feet (fig. 2.4).
WARNING
Be carefull: do not lift the cooker by
the door handle when raising to the
upright position (fig. 2.5).
WARNING
When moving cooker to its final position
DO
NOT DRAG (fig. 2.6).
Lift feet clear of floor (fig. 2.4).
LEVELLING THE COOKER
The cooker may be levelled by screwing
the lower ends of the feet IN or OUT
(fig. 2.7).
9
The room containing the cooker should have an air supply in accordance with BS.5540:
Part 2: 1989.
All rooms require an openable window or equivalent while some rooms require a permanent vent in addition to the openable window.
The cooker should not be installed in a bed-sitting room, of volume less than 21 m
3
.
Where a DOMESTIC COOKER is installed in a room or internal space, that room or
internal space shall be provided with a permanent opening which communicates directly
with outside air and is sized in accordance with table below. In domestic premises the
permanent opening shall be an air vent.
If there are other fuel burning appliances in the same room, BS.5540: Part 2: 1989
should be consulted to determine the requisite air vent requirements.
If the cooker is installed in a cellar or basement, it is advisable to provide an air vent
of effective area 100 cm
2
, irrespective of the room volume.
(❊)
If the room or internal space containing these appliances has a door which opens
directly to outside, no permanent opening is required.
MINIMUM PERMANENT OPENING FREE AREA FOR FLUELESS APPLIANCE
5 m3to 10
m
3
Openable
window or
equivalent also
required
Maximum
appliance
rated input
limit
Room volume
11 m3to
20 m
3
> 20 m
3
< 5 m
3
Type of appliance
Domestic oven, hot-
plate, grill or any com-
bination thereof.
None
50 (❊)
cm
2
Nil
cm
2
Nil
cm
2
100
cm
2
Yes
Provison for ventilation
10
3 - Gas connection
GAS INSTALLATION
IMPORTANT NOTE
This appliance is supplied for use on
NATURAL GAS only and cannot be used
on any other gas without modification.
This appliance is manufactured for
conversion to LPG if required and is
supplied with a conversion kit.
The cooker must be installed by a
qualified person in accordance with the
Gas Safety (Installation and Use)
(Amendment) Regulation 1990 and the
relevant building/l.E.E. Regulations.
The following British Standards should
be used as reference when installing this
appliance.
BS6172 1990, BS5440 part 2 1989 and
BS6891 1988.
Failure to install the appliance correctly
could invalidate any manufacturers
warranty and lead to prosecution under
the above quoted regulation.
In the UK C.O.R.G.I registered installers
are authorised to undertake the
installation and service work in
compliance with the above regulations.
GAS CONNECTION
The installation of the cooker to Natural
Gas or LP Gas must be carried out by
a qualified gas engineer. Installers shall
take due account of the provisions of the
relevant British Standards Code of
Practice, the Gas Safety Regulations
and the Building Standards (Scotland)
(Consolidation) Regulations issued by
the Scottish Development Department.
INSTALLATION TO NATURAL GAS
Installation to Natural Gas must conform
to the Code of Practice, etc. The supply
pressure for Natural Gas is 20 mbar.
INSTALLATION TO LP GAS
This appliance must only be connected
to LPG after an LPG conversion kit has
been fitted, (see pages from 12 to 13).
When operating on Butane gas a supply
pressure of 28-30 mbar is required.
When using Propane gas a supply
pressure of 37 mbar is required.
The installation must conform to the
relevant British Standards.
Warning: Only a qualified gas engineer,
also with technical knowledge of
electricity should install the cooker. He
should observe the Regulations and
Codes of Practice governing such
installation of gas cookers.
Note: It is recommended that the gas
connection to the cooker is installed with
a flexible connecting tube made to BS
5386.
11
GAS CONNECTION
The gas supply must be connected to
the gas inlet which is located at the left
or the right hand rear of the appliance
(fig. 3.1).
The pipe does not cross the cooker.
When screwing the connecting tube
operate with two spanners (fig. 3.2).
The unused end inlet pipe must be
closed with the plug, interposing the
gasket.
After connecting to the mains, check
that the coupling are correctly sealed,
using soapy solution, but never a
flame.
Fig. 3.2
Plug
Fig. 3.1