CAPKOLD CKAC-3-6H User Manual

Compressed Air System
CapKold Cook-Chill Production Systems
Accessories
r CKAC-3-6H [3HP, 60 Gal. Horizontal Tank] r CKAC5-8H [5HP, 80 Gal. Horizontal Tank]
CKAC7.5-12H [7.5HP, 120 Gal. Horizontal Tank]
General Description:
CapKold Model: CKAC____ (Specify size) air compressor, designed to provide sufficient volume of clean, high pressure compressed air at 90 PSIG, necessary for all air powered or air activated equipment and components in the CapKold Cook-Chill Production Kitchen.
Air Compressor Sizing Guide:
Review proposed equipment package and note those components that utilize compressed air. Multiply flow rate by the number of units, then total the far right column for maximum SCFM total required.
r CKAC10-12H [10HP, 120 Gal. Horizontal Tank] r CKAC15-12H [15HP, 120 Gal. Horizontal Tank]
Air Compressor Model Guide:
To ensure sufficient compressed air volume, specify a compressor with a CFM delivery rate equal to or higher than the total cfm required for all system components and applications listed above.
Air Compressor Construction [all models]:
• Splash lubricated reciprocating compressor with cast iron
cylinders and heads
• Alloy steel, self-cleaning reed valves
• NEMA rated electric motor with enclosed, hinged belt guard
• Air intake filter/silencer
Notes:
• If CKPF/3 Pump/Fill [with clipper] and additional Model CVE or CVW vacuum clipper will not be used simultaneously, 8 SCFM
may be deducted from total air
• If multiple kettles with air valves are specified, typically only one will require air during product transfer using the CKPF/3 Pump/Fill
• Vertical Tank models can be specified in installations where avail­able space in utility room is limited. Vertical and horizontal tank
units of the same size have similar performance
1055 Mendell Davis Drive, Jackson, MS 39272 888-994-7636, unifiedbrands.net
Please reference our website for the most updated product information and specifications.
Control Systems:
• Automatic start-stop operation
• 0-200 PSIG air pressure gauge on tank
• Manual drain tank
• Refrigerated air dryer
• Automatic tank drains
• Vibration isolators
• Mounted and wired magnetic starters
• Low Oil Monitor
• Air cooled after-cooler (mounted)
Options:
r Vertical air receiver tank, refrigerated air dryer would ship loose
and mount separately.
Groen CapKold Accessories, Page 30
CKAC 160676A
Revised 08/06
CKAC Compressed Air System
AIR COMPRESSOR
160677 REV A
WITH STARTER, DISCONNECT, AIR DRYER, FILTERS
AND REGULATOR
IW2
C
CA
IW
EP
IW
PHYSICAL DIMENSIONS
MODEL
CKAC3-6H
CKAC5-8H
CKAC7.5-12H CKAC10-12H CKAC15-12H 100-1/2"
A
70" 50"
77"
100-1/2"
100-1/2"
50" 50" 55" 55"
EP
B
TOP VIEW
FRONT VIEW
C
31-1/2" 31-1/2"
27" 28-1/4" 28-1/4"
IW1
IW2
A
RECOMMENDED CLEARANCES
FRONT
48" 48" 48" 48" 48"
RIGHT
LEFT
12" 12" 12"
12"
12"
12"
12"
12" 12"
12" 12" 12" 12"
AIR FILTERS ARE SUPPLIED AND INSTALLED
B
IW
CA
IW1
SIDE VIEW
REAR
12" 12"
IW2
CA
UTILITY CONNECTIONS (ALL MODELS)
SYMBOL
DESCRIPTION
CONNECTION
CA IW
COMPRESSED
AIR
OUTLET 3/4" NPT
AUTOMATIC
DRAIN
IW1 IW2
MANUAL
TANK
DRAIN
REFRIGERATED
DRYER
TANK
1/4" HOSE3/8" NPT1/4" NPT
EP
POWER SUPPLY
3/4"
UTILITY REQUIREMENTS
WEIGHT (lbs.)
SHIPPING
580 630 920 990
1080
MODEL
CKAC3-8H CKAC5-8H CKAC7.5-12H CKAC10-12H CKAC15-12H
COMPRESSED
AIR @
175 PSI
9.7 CFM
16.5 CFM
22.9 CFM
34.8 CFM 49 CFM
ELECTRICAL
208, 230/460/3/60
HP
12 A, 11 A, 6 A
3
20 A, 19 A, 11 A
5
29 A, 26 A, 15 A
7.5 36 A, 32 A, 18 A
10
48 A, 44 A, 22 A
15
NOTE: DO NOT INSTALL OUTDOORS OR IN A FREEZING AMBIENT ENVIRONMENT OR A LOCATION THAT EXCEEDS 100º F.
1055 Mendell Davis Drive, Jackson, MS 39272, 888-994-7636, unifiedbrands.net
© 2009 Unified Brands. All Rights Reserved. DOVER® and the DOVER® Logo are registered trademarks in the United States [and various other countries] of Unified Brands, a wholly-owned subsidiary of Dover Corporation.