1. Install the USB driver from the included CD. The driver and the configuration
software may also be downloaded from www.cansec.com/downloads.
2. Install and run the Canlan M200 configuration software.
3. Connect the Canlan M200 to your PC using the USB cable provided.
NOTE: The cross-over network cable provided may be used instead of the USB cable. Refer to the Canlan M200 Installation Manual for important connection information.
4. Verify the COM port number used by the Canlan M200 by going to:
Control Panel > System >Hardware > Device Manager->Port. Example “USB Serial Port (COM4)”.
5. From the Canlan M200 configuration software, click the Connect button.
CanLan M200 Page 2 of 6 Quick Start Guide April 2014 • Rev. 1.3
Page 3
6. Select Connect via Serial Port and choose the appropriate COM port from the
drop-down menu.
CanLan M200 Page 3 of 6 Quick Start Guide April 2014 • Rev. 1.3
Page 4
7. Power on the Canlan M200 using the AC-DC adaptor provided. If the Canlan
Device Reset Button
M200 is already powered on, use a pin to press and release the reset button in the reset pin hole.
8. Press OK within 20 seconds. You should see the message Unit Online along
with all default configuration parameters.
CanLan M200 Page 4 of 6 Quick Start Guide April 2014 • Rev. 1.3
Page 5
Troubleshooting
If a connection cannot be established, you will see the message Unit Offline.
1. Make sure you are using the right COM port number.
2. Unplug the AC-DC adaptor and plug it back in again or use a pin to press
and release the reset button if it’s already powered on.
3. Wait for the Cfg/Err LED to come on then click the Connect button to retry
the connection.
4. For more troubleshooting tips, see the Canlan M200 Installation Manual.
CanLan M200 Page 5 of 6 Quick Start Guide April 2014 • Rev. 1.3
Page 6
Configure
1. Address Configuration - enter the IP address, subnet mask, default gateway, and
port number provided by your network administrator.
2. Operational Mode - select your access control system.
NOTE: Idle auto-disconnect is enabled by default for SmartLock Pro/SMA, Zodiac Max
and SmartLock Pro Plus with a value of 1.
3. Remote Diagnostics - select remote diagnostics and enter an optional 8-digit
password.
4. RS485 Serial Interface – These settings are set accordingly when the operational
mode is selected. Maestro and SmartLock Pro/Connect share the same default settings. Zodiac Max also shares the same settings except the baud rate is set to
38400. The default settings for Maestro and SmartLock Pro/Connect are as follow:
Baud Rate: 9600
Parity: None, 1 Stop Bit
Data Bits: 8 Bits
5. IP Security is optional. Select the checkbox “Only allow connections from the IP
below” and enter the IP address that is allowed to connect to this Canlan for
communication. Leave the checkbox unchecked if IP Security is not used.
6. Click Save if any changes were made.
7. Optionally, click Backup to back up the configuration to a binary file for future
restoration. The file will be saved in the same folder as the Canlan configuration software.