Canplas 393243A Installation Manual

VENT
VERTICAL STRAINER IN P-TRAP POSITION
SINK
IDS VERTICAL (P-TRAP CONFIGURATION)
HORIZONTAL STRAINER
P TRAP
IDS HORIZONTAL WITH P-TRAP
VENT
SINK
VENT
HORIZONTAL STRAINER IN P-TRAP POSITION
SINK
IDS HORIZONTAL (P-TRAP CONFIGURATION) IDS HORIZONTAL WITH ALTERNATE P-TRAP
P TRAP
VENT
SINK
VENT
HORIZONTAL STRAINER
P TRAP
IDS HORIZONTAL WITH P-TRAP
SINK
IDS HORIZONTAL WITH ALTERNATE P-TRAP
P TRAP
VENT
SINK
393243A (ABS) 393243AW (PVC)
Replacement Filter and Access Cap Assembly 393243AR (ABS) 393243AWR (PVC)
11/30/06
Installation and Operation Instructions
Thank you for purchasing the Endura InLine Drain Strainer. The Endura IDS is intended for installation on individual sink wastes in kitchen and sanitary applications, or where there are materials or objects that need to be prevented from entering the drainage system. These may be such things as, but not limited to food debris, hair, lint or even
valuable items such as jewelry.
Installation Instructions:
The Endura IDS can be installed either horizontally or vertically and can be used to provide a water seal trap, thereby replacing the need for a P-Trap. Provided ‘loose assembled’ the inlet and outlet can be orientated to best suit your application, both hubs accepting 1-1/2” DWV pipe.
When making your installation, ensure that at least 8” of clearance remains in the direction of the lter screen removal. Once conrmed in its nal orientation, the two main body are solvent welded using regular pipe jointing cement. Note: If joining ABS to PVC, a suitable transition cement must be used. For connection to the inlet and outlet hubs, the same holds true and should you require to make connection to other tubular materials, a full range of trap adaptors are also available from Canplas.
Operation Instructions:
Once installed and operational, the IDS is cleaned by removing the access cap. This is unscrewed in an anti-clockwise direction. As it is removed the lter screen, assembled as an integrated part of the cap, self cleans the inside surface of the IDS. Clean the accumulated debris and ret the lter screen and cap.
Cleaning frequency is entirely dependant on application but typically a noticeable slowing of your drainage discharge will be evident and indi­cate the requirement for cleaning.
Depending on the orientation of your nal installation (P-trap congura­tion for instance), the unit may contain a quantity of waste water, so be sure to have a suitable container to hand to catch any spillage upon opening. The lter screen and cap are replaced in the reverse manner of opening, ensuring that the O-ring seal on the access cap remains in place and in good condition. Hand tighten only.
393243A-5
Canplas Industries Ltd.
P.O. Box 1800, 500 Veterans Drive Barrie, Ontario Canada L4M 4V3 Tel: (705) 726-3361 Toll Free: 1-800-461-5300 Fax: (705) 726-2186 Website: www.endurainterceptor.com
Canplas LLC
11402 East 53rd Ave. Suite 200, Denver, CO U.S.A. 80239 Tel: (303) 373-1918 Toll Free: 1-888-461-5307 Fax: (303) 373-1923 Website: www.endurainterceptor.com
Email: denver.sales@canplas.com
Loading...