Drawing 1 - Fixture Assembly
D
K
6
assembly instructions
start here
1. Find a clear area in which you can work.
2. Unpack fixture and glass from carton.
3. Carefully review instructions prior to assembly.
7
10
12
Drawing 2 - Strap Detail
B
gull wing bracket
Drawing 3 - Fixture Mounting
(side view)
1
G
H
11
*** The construction of this fixture will be accomplished by first assembling the main body, installing the mounting hardware, making all necessary electrical connections, attaching the shade and then installing the fixture glass.
2
3
4
5 8
1. To assemble main body, take center column assembly (1) and thread tubing (2) into
coupler (G) approximately 3/8”- see Drawing 1.
2. Thread hex nut (H) up against coupler (G) and tighten to secure tubing (2).
3. Slip sleeve (3) over tubing (2) and hold in position.
4. Slip cap (4) onto tubing (2) and up against bottom of sleeve (3) and hold in position.
5. Slip rubber washer (5) and push up against cap (4). Note: rubber washer (5) should
hold all parts in position.
9
1. Prepare gem strap (A) for mounting by threading two screws (B) provided into
back of gull wing bracket of gem strap (A) - see Drawing 2.
Be sure the holes into which the screws are threaded match the spacing of holes (D) in the ceiling pan (1) - see Drawings 2 and 3.
2. Mount gem strap (A) to junction box (J), using the two 1” screws (C) provided.
B
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
1. Hang the fixture by slipping the holes (D) in the ceiling pan (1) over the screws (B) in the mounting strap (A) - see Drawing 3.
2. Thread on ball knobs (F) to secure fixture to the ceiling.
6
1
D F
1. Prior to installing glass, fixture can now be lamped accordingly.
2. To install glass, hook one end of upright (6) to loop (K) on ceiling canopy (D) - see
Drawing 1.
3. Hook circular loops on top of shade (7) onto end of upright (6).
4. Slip circular glass (8) onto tubing (2) and hold in position.
5. Slip washer (9) onto tubing (2) and hold in position.
6. Thread hex nut (10) onto tubing (2) and tighten to secure glass (8).
7. Slip bottom cap (11) and thread bottom knob (12) onto tubing (2) and tighten to secure.
Drawing 1 - Flush Mount
supply wire
A CC
E
wiring grounding instructions
SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.
wiring instructions
Indoor Fixtures
B
fixture leads
Drawing 2 - Chain Hung
supply wire
connectors
twist-on
D
A C
twist-on
E
E
connectors
1
E
E
D
B
fixture leads
Drawing 3 - Post-Mount
supply wire
A C
2
E
twist-on connectors
E
D
B
fixture leads
1
2
1. Connect positive supply wire (A) (typically black or the smooth, unmarked
side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 1 or 2.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Please refer to the grounding instructions below to complete all electrical connections.
Outdoor Fixtures
1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector - see Drawings 2 or 3.
2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
3. Cover open end of connectors with silicone sealant to form a watertight seal.
If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.
4. Please refer to the grounding instructions below to complete all electrical connections.
grounding instructions
Flush Mount Fixtures
For positive grounding in a 3-wire electrical system, fasten the fixture ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (1) with the ground screw (2) - see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.
Chain Hung Fixtures
Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (2) on fixture mounting strap (1) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors - see Drawing 2.
Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated) to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal - see Drawing 3.