Please read this manual before installing and using the heater.
SAFETY WARNINGS
What to do if you smell gas
1. Turn OFF the main gas supply.
2. Extinguish any open flame.
3. Open windows.
4. Do not touch electrical switches.
5. Do not use your telephone.
6. Call your gas supplier immediately from a neighbour’s phone.
Warnings
1. Improper installation, adjustment, alteration, service or maintenance can cause
injury or property damage. Refer to the sections of this manual for correct
procedures, or consult with place of purchase, a licensed plumber, a gas supplier
or the CANNON distributor listed in this manual.
2. Install the heater only in locations that are referred to in the installation instructions.
Do not build the heater into bookcases, walls or enclosures without the use of a
Mock Fireplace kit if appropriate for that type of installation.
3. Due to high temperatures the room heater should be located out of traffic and away
from:
Furniture and draperies
Combustible materials
Gasoline and other flammable liquids
Do not place clothing or other flammable material on or near the heater.
4. Keep curtains*, clothes, furniture and other flammable materials at least
900mm from front and sides of heater.
* At the owner’s discretion curtain clearance can be less than 900mm as
long as they are restrained from the front, top and sides of the heater. The
manufacturer takes no responsibility if curtain clearance is less than 900mm
and not restrained.
5. Children and adults should be alerted to the hazard of high surface temperature
and should take care to avoid burns or clothing ignition.
This appliance is not intended for use by persons (including children) with reduced
physical, sensory or mental capabilities or lack of experience and knowledge,
unless they have been given supervision or instruction concerning use of the
appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the appliance.
6. Never attempt to burn paper or any other material in the heater.
7. Do not place articles on or against this appliance.
Do not use or store flammable materials near this appliance.
Do not spray aerosols in the vicinity of this appliance while it is in operation.
Do not modify this appliance.
notes
TO REPLACE THE
COMBUSTION FAN
The Combustion Fan is accessed from the rear of the heater.
Therefore to replace the combustion fan the heater must be
removed from the fireplace. The flue terminal may need to be
removed from the flue hoses to allow the heater to be moved.
1. Disconnect combustion fan wiring from loom.
2. Remove the rear cover.
3. Remove the four (4) screws securing the fan to fan duct.
4. Remove fan assembly from fan duct.
5. Replace in reverse to disassembly.
TO REMOVE THE BURNER
AND ELECTRODES
TO REPLACE TYPE “X”
CORD
1. Remove the front mesh cover.
2. Slacken off the glass clamp screws and remove the
top and one side clamp.
3. Follow fig 25. of the installation instructions
for glass removal.
4. Remove the logs from the burner chamber.
5. Remove the inspection hatch cover.
6. Disconnect supply pipe nut from the burner manifold.
7. Remove the electrode connections from the spark
module.
8. Release gland seal retaining nut.
9. Remove burner fixing brackets (2) from rh and lh
sides of the burner. lift the burner assembly upwards
and carefully remove from the burner chamber.
10. Pull electrode leads from the gland seal.
11. Replace in reverse order.
1. CONTACT SAMPFORDIXL SERVICE DEPARTMENT AND QUOTE CORD
PART NUMBER F2799.
SERVICE INSTRUCTIONS
24
5
FIG 31.