CANDY PG640 User Manual

0 (0)
HOBS USER INSTRUCTIONS
IEGB
32
INSTRUCTIONS FOR THE INSTALLER
INSTALLATION
The Purchaser is responsible for the installation of the hob. The Manufacturer does not accept any responsibility for any damage or loss resulting from incorrect installation, and as such this will not covered by the Manufacturer’s Guarantee. The hob may be installed in any worktop which is heat resistant to a temperature of 100° C, and has a thickness of 25 - 45 mm. The dimensions of the insert to be cut out of the worktop are in shown in Fig. 1. If the Hob is fitted next to a cabinet on either side, the distance between the Hob and the cabinet must be at least 15 cm (see Fig. 2); while the distance between the hob and the rear wall must be at least 5,5 cm. The distance between the hob and any other unit or appliance above it (e.g. An extrac­tor hood) must be no less than 70 cm (fig.2). When there is an accessible space between the built-in hob and the cavity below, a divi­ding wall made of insulating material should be inserted (wood or a similar material). The wall should be at least 10 mm away from bottom of the drawer. (fig. 3)
Important - The diagram below shows how the sealant should be applied.
The Hob unit is fitted by attaching the Fixing Clamps supplied, using the holes at the base of the unit.
GBIE
Fig. 1
Fig. 2
Fig. 3
31
TECHNICAL CHARACTERISTICS
* Manufacturer setting IE cat. II2H3+ GB cat. II2H3+
Cooking hobs A B C D
Tab.1
Burners 4 gas 4 gas 3 gas 4 gas
1 electric 1 electric – Reference type (Type) PL03/PL04 PL03/PL04 PL03/PL04 PL03/PL04 Gas safety device - / yes - / yes - / yes - / yes Double ring burner DC ø 110 mm - / 1 - / 1 - - / 1 Maxi burner UR ø 110 mm 1 / 1 - 1 / 1 1 / 1 Medium burner SR ø 51mm 2 2 2 2 Large burner R ø 71 mm 1 1 1 1 Steak griddle - - - 1 Electric hotplate/ring PE - 1 1 ­Power of gas installed:
- G20/20 mbar * (METANO) 8,95 kW 8,95 kW 6,3 kW 8,95 kW
- G30/28-30 mbar (GPL) 649 g/h 649 g/h 456 g/h 649 g/h Installation class 3 3 3 3 Supply Voltage 230V/50Hz 230V/50Hz 230V/50Hz 230V/50Hz Installed electric power - 450W 1400W ­Electric ignition yes yes yes yes Product size mm. 590x510 590x510 590x510 590x510
D
B
C
A
This appliance has been designed for non-professional, i.e. domestic, use.
GB IE
accessible space
3433
FOR U.K. ONLY INSTRUCTIONS FOR THE INSTALLER
The following information is intended for qualified and competant persons only who will ensure that your appliance is installed correctly. All current legislation concerning the in­stallation of Gas appliances must be observed by the installer* * For the U.K. only - By law, the gas installation/commissioning must be carried out by a «Corgi», registered installer.
This appliance must be installed in accordance with applicable regulations and should only be used in well-ventilated locations. Before using this appliance carefully study the instruction book.
Suitable location
A gas-powered cooking appliance produces heat and humidity in the area in which it is installed. For this reason you should ensure good ventilation either by keeping all natu­ral air passages open or by installing an extractor hood with an exhaust flue. Intensive and prolonged use of the appliance may require extra ventilation, such the opening of a window or an increase in speed of the electric fan, if you have one. If a hood cannot be installed, an electric fan should be fitted to an outside wall or win­dow as long there are air vents in the area. The electric fan should be able to carry out a complete change of air in the kitchen 3-5 times every hour. The installer should follow the relavant national standards.
If the hob is fitted above an oven which is not equipped with fan cooling system it is re­commended that openings are created within the built in furniture to ensure correct air circulation. The size of these openings must be at least 300 cm
2
and placed as shown in fig. 4.
ELECTRICAL CONNECTION (FOR U.K. ONLY)
Warning - this appliance must be earthed
This appliance is designed for domestic use only. Connection to the mains supply must be made by a competant electrician, ensuring that all current regulations concerning such installations are observed. The appliance must only be connected to a suitably rated spur point, a 3 pin 13 amp plug/socket is not suitable. A double pole switch must be provided and the circuit must have appropriate fuse protection. Further details of the power requirement of the in­dividual product will be found in the users’ instruction and on the appliance rating plate.
In the case of built-in product you are advised, should you wish to use a longer cable than the one supplied, that a suitably rated heat resistant type must be used. The wiring must be connected to the mains supply as follows:
CONNECT TO SPUR TERMINAL
Green & Yellow Wire Earth Connection Blue Wire Neutral Connection Brown Wire Live Connection
Note: We do not advocate the use of earth leakage devices with electric cooking applian­ces installed to spur points because of the «nuisance tripping» which may occur. You are again reminded that the appliance must be correctly earthed, the manufacturer decli­nes any responsibility for any event occurring as a result of incorrect electrical installation.
FIG. 4
60 Cm
2
240 Cm
2
120 Cm
2
180 Cm
2
GB IE GB IE
Declaration of compliance: This equipment, in the parts intended to come into con-
tact with food, complies with the regulations laid down in EEC directives 89/109.
This appliance complies with directive 89/336/EEC, 73/23/EEC, 90/396/EEC and the following changes.
GAS CONNECTION (FOR U.K. ONLY)
The labels on the Hob indicate the types of gas that can be used. It is possible to use other types of gas after carrying out simple modifications. Warning: If gas can be smelt in the vicinity of this appliance turn off the gas supply to the appliance and call the engineer directly. Do not search for a leak with a naked flame.
Loading...
+ 4 hidden pages