CANDD DNX301-U4H, DNX301-U4G, DNX301-U4F, DNX301-U4E, DNX301-U4D Datasheet

...
Product Data Sheet
300 WATT
DC/DC POWER SUPPLY
DNX301
Fully Isolated Outputs
Low Profile: 9” x 4.85” x 2.00”
One, Two, Three and Four
Output Models
N+1 Current Sharing
Optional Fan Mounted On
Cover
Active Inrush Current Limiting
DESCRIPTION
The DNX301 is a compact 300 watt, multiple output power supply. All outputs are fully isolated and regulated. Active current sharing circuitry on Output #1, together with control functions and alarm options, simplifies N+1 and redundant applications. Fan and disk drive applications are handled by the peak current ratings of the auxiliary outputs.
Website: http://www.cdpowerelectronics.com
Power Electronics Division, United States
3400 E Britannia Drive, Tucson, Arizona 85706
Tel: 800.547.2537 Fax: 520.295.4197
Any data, prices, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice. While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user’s intended purpose and in user’s specific application. C&D Technologies, Inc. does not warrant or recommend that any of its products be used in any life support or aviation or aerospace applications.
Tel: +44 (0)1908 615232 Fax: +44 (0)1908 617545
Milton Keynes MK14 5BU UK
AGENCY APPROVALS
See “Safety” section on page 2 for more information
C&D Technologies, (NCL)
DNX301 4/2002 REV B Page 1
Input Specifications
Parameter Conditions Min Typ Max Units
Operating Range DC 36 48 72 VDC
Inrush Current Limiting
36VD 25 APK
72VDC 50 APK
Efficiency 48 VDC, at full load 70 %
Remote Sense
Remote Sense is provided on Output #1 and will compensate for 0.7V of line drop. Remote Sense leads
are protected against open, short and reversal.
Remote On/Off (Optional)
The power supply is turned on with a TTL logic ‘1’ (or open) signal and turned off by a switch closure or TTL logic ‘0’ referenced to (-) sense terminal. Consult the factory for other options.
Over Voltage Protection
Output #1: 6.5V ± 0.5 VDC. The power supply will latch off until AC power is cycled.
Over Current Protection
Individual current limit on all outputs. Automatic recovery upon fault removal.
Active Inrush Current Limiting
Inrush current is independent of ambient temperature.
Transient Response
The peak output voltage excursion will not exceed 2% and will recover within 1% in 200 µsec for a 25% load step change.
Over Temperature Protection
Thermal switch turns off power supply if overheating occurs and automatically restarts.
Safety
Safety certified to UL/CUL to 1950, File Number E131694 TUV to EN60950/IEC950.
Cooling
The unit is designed to operate with 30 CFM of airflow.