CANDD cPCI500DC Datasheet

Corporate: www.cdtechno.com Product: www.cdpowerelectronics.com
cPCI500DC
500 Watt, 6U x 4HP, CompactPCI
Corporate: www.cdtechno.com
6U X 4HP
36-72 VDC Input Range
500 Watt Continuous Output
Complies with PICMG 2.11
R1.0 with 47 Pin I/O Connector
Hot-Swap Capable
The cPCI500DC is a high-reliability, 500 watt power supply for 6U Compact PCI™ systems. Developed to support hot-swap, redundant operation, the cPCI500DC is designed for compliance with PICMG™ 2.11 R1.0 Power Interface Specification with 47-pin I/O connector, as well as the underlying CompactPCI™ standards. Available with IPMI functionality, this unit was developed with high-availability (HA)
Outputs Individually Protected
Against Overloads; Automatic Recovery
PCI VoltageArchitecture
(5V, 3.3V,+12V,-12V)
IPMI Capability
No Minimum Load
telecommunications applications in mind. Current sharing and internal ORing diodes are included to support these and other applications requiring reliable, hot-swap performance and N+1 redundant configuration. The 4HP package and complement of agency approvals provide for an advanced, high-density, high-efficiency power solution for your CompactPCI™ system requirements.
SPECIFICATIONS, ALL MODELS
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
Input Operating Voltage Vin 36 72 VDC Input Voltage Withstand 34 75 VDC Inrush Current I
INPUT
Efficiency η 48VDC input, 500W load 80 %
OUTPUT NUMBER RATED OUTPUT VOLTAGE Min A* B* REGULATION
V1 +5.0VDC 0A 55.0 A 30.0 A +/-1% V2 +3.3VDC 0A 30.0 A 60.0 A +/-1% V3 +12.0VDC 0A 11.0 A 11.0 A +/-1% V4 -12.0VDC 0A 1.75 A 1.75 A +3, -3%
PARAMETER SYMBOL CONDITIONS MIN TYP MAX UNITS
OUTPUT
Temperature Coefficient TC 0.02 %/°C PARD 20MHz bandwidth 50 mV
Output Power 50°C max temp. 500 W
* Total output power not to exceed 500 Watts
i
VOUT RATED OUTPUT CURRENTOUTPUT
36VDC input 10 APK 72VDC input 20 APK
IOUT
all outputs or 1.5% P-P
whichever is greater
cPCI500-DC REV D 8/2002
P-P
SPECIFICATIONS, ALL MODELS
Transient Response
For a step load change of 50%-100%-50%, the peak output excursion will not exceed 8% of nominal voltage, and will recover to within 1% of nominal voltage within 200 microseconds.
Current Share
Active current sharing is employed on Outputs V1, V2 and V3.
Remote Sense
Outputs V1, V2, and V3 are capable of compensating up to
DC of line drop. Unit automatically reverts to local
0.3V sensing in the event that the sense leads are opened for any reason. Unit is protected against reversed or shorted sense leads.
Output Power
500W continuous maximum, with 400lfm airflow at a maximum ambient of 50°C.
Overload Protection
Outputs are individually protected against overloads and indefinite short circuit with automatic recovery upon removal of the fault condition.
Over Voltage Protection
All outputs have over voltage protection at 125% typical (135% max.) of nominal.
Over Temperature Protection
Outputs are individually protected against over temperature. Outputs will automatically restore upon recovery to acceptable temperatures.
Output Fault Isolation
Output isolation diodes are present in all outputs to isolate faults within a failed power supply.
IPMI Option
2
C board is available as a factory-installed option to
An I provide an IPMI interface to the SM bus. Status functions include output voltage and current levels as well as the DEG warning. Output inhibit control can be toggled under software command. See Application Note ACAN-02 for satellite controller specification, ACAN-03 for firmware update procedure and ACAN-04 for test procedure.
Remote Inhibit (INH#)
Secondary referenced, active low, TTL compatible signal inhibits all outputs upon activation.
Power Fail Warning (FAL#)
Open collector signal indicates output failure. Active low.
Enable (EN#)
Short pin on connector will enable power supply output when the mating pin is grounded. Supply will not power up until this pin is engaged to its mate in the backplane. Unit output will be inhibited as pin is disengaged from the mating connector.
Temperature Warning (DEG#)
Open collector indicates internal temperatures are approaching the thermal shutdown limit. Active low.
Fault Indicator LED
A red LED will be ON if output voltages are not within specification.
Power Present LED
A green LED will be ON when input voltage is present and above the minimum requirement.
Cooling
400lfm of airflow required to maintain full output power at 0­50°C ambient. Additional data on operation below 400lfm is available in Application Note ACAN-01.
Temperature
Full output power achievable over the range of 0-50°C. Storage temperature limits are –20 to +85°C. Additional data on operation above 50°C is available in Application Note ACAN-01.
Altitude
Operating: -200 to +10,000 feet with ambient temperature derating above 5,000 feet in accordance with the adiabatic lapse rate.
Inhibit Indicator LED (Yellow)
A yellow LED will be ON when the outputs are inhibited.
Product: www.cdpowerelectronics.com
cPCI500-DC REV D 8/2002
2